990 resultados para System disturbances
Resumo:
Heat stroke is a life-threatening condition that can be fatal if not appropriately managed. Although heat stroke has been recognised as a medical condition for centuries, a universally accepted definition of heat stroke is lacking and the pathology of heat stroke is not fully understood. Information derived from autopsy reports and the clinical presentation of patients with heat stroke indicates that hyperthermia, septicaemia, central nervous system impairment and cardiovascular failure play important roles in the pathology of heat stroke. The current models of heat stroke advocate that heat stroke is triggered by hyperthermia but is driven by endotoxaemia. Endotoxaemia triggers the systemic inflammatory response, which can lead to systemic coagulation and haemorrhage, necrosis, cell death and multi-organ failure. However, the current heat stroke models cannot fully explain the discrepancies in high core temperature (Tc) as a trigger of heat stroke within and between individuals. Research on the concept of critical Tc: as a limitation to endurance exercise implies that a high Tc may function as a signal to trigger the protective mechanisms against heat stroke. Athletes undergoing a period of intense training are subjected to a variety of immune and gastrointestinal (GI) disturbances. The immune disturbances include the suppression of immune cells and their functions, suppression of cell-mediated immunity, translocation of lipopolysaccharide (LPS), suppression of anti-LPS antibodies, increased macrophage activity due to muscle tissue damage, and increased concentration of circulating inflammatory and pyrogenic cytokines. Common symptoms of exercise-induced GI disturbances include diarrhoea, vomiting, gastrointestinal bleeding, and cramps, which may increase gut-related LPS translocation. This article discusses the current evidence that supports the argument that these exercise-induced immune and GI disturbances may contribute to the development of endotoxaemia and heat stroke. When endotoxaemia can be tolerated or prevented, continuing exercise and heat exposure will elevate Tc to a higher level (> 42 degrees C), where heat stroke may occur through the direct thermal effects of heat on organ tissues and cells. We also discuss the evidence suggesting that heat stroke may occur through endotoxaemia (heat sepsis), the primary pathway of heat stroke, or hyperthermia, the secondary pathway of heat stroke. The existence of these two pathways of heat stroke and the contribution of exercise-induced immune and GI disturbances in the primary pathway of heat stroke are illustrated in the dual pathway model of heat stroke. This model of heat stroke suggests that prolonged intense exercise suppresses anti-LPS mechanisms, and promotes inflammatory and pyrogenic activities in the pathway of heat stroke.
Resumo:
Chagas heart disease (CHD) results from infection with the protozoan parasite Trypanosoma cruzi and is the leading cause of infectious myocarditis worldwide. It poses a substantial public health burden due to high morbidity and mortality. CHD is also the most serious and frequent manifestation of chronic Chagas disease and appears in 20-40% of infected individuals between 10-30 years after the original acute infection. In recent decades, numerous clinical and experimental investigations have shown that a low-grade but incessant parasitism, along with an accompanying immunological response [either parasite-driven (most likely) or autoimmune-mediated], plays an important role in producing myocardial damage in CHD. At the same time, primary neuronal damage and microvascular dysfunction have been described as ancillary pathogenic mechanisms. Conduction system disturbances, atrial and ventricular arrhythmias, congestive heart failure, systemic and pulmonary thromboembolism and sudden cardiac death are the most common clinical manifestations of chronic Chagas cardiomyopathy. Management of CHD aims to relieve symptoms, identify markers of unfavourable prognosis and treat those individuals at increased risk of disease progression or death. This article reviews the pathophysiology of myocardial damage, discusses the value of current risk stratification models and proposes an algorithm to guide mortality risk assessment and therapeutic decision-making in patients with CHD.
Resumo:
NlmCategory="UNASSIGNED">Rapid deployment aortic valve replacement (RDAVR) with the use of rapid deployment valve systems represents a smart alternative to the use of standard aortic bioprosthesis for aortic valve replacement. Nevertheless, its use is still debatable in patients with pure aortic valve regurgitation or true bicuspid aortic valve because of the risk of postoperative paravalvular leak. To address this issue, an optimal annulus-valve size match seems to be the ideal surgical strategy. This article describes a new technique developed to stabilize the aortic annulus and prevent paravalvular leak after RDAVR. To confirm the feasibility, this technique was performed in six patients with severe symptomatic aortic stenosis who were scheduled to undergo aortic valve replacement at our center. All patients survived surgery and were discharged from the hospital. There were no new intracardiac conduction system disturbances observed, and a permanent pacemaker implantation was not required in any of the patients. The intraoperative and postoperative echocardiogram confirmed successful positioning of the valve, and no paravalvular leak was observed. In this preliminary experience, RDAVR through a full sternotomy or an upper hemisternotomy approach with the use of aortic annulus stabilization technique was safe, and no leak was observed. Future studies on large series of patients are necessary to confirm the safety and effectiveness of this technique in preventing paravalvular leak in patients with true bicuspid aortic valves or pure aortic regurgitation.
Resumo:
Much of the published human factors work on risk is to do with safety and within this is concerned with prediction and analysis of human error and with human reliability assessment. Less has been published on human factors contributions to understanding and managing project, business, engineering and other forms of risk and still less jointly assessing risk to do with broad issues of ‘safety’ and broad issues of ‘production’ or ‘performance’. This paper contains a general commentary on human factors and assessment of risk of various kinds, in the context of the aims of ergonomics and concerns about being too risk averse. The paper then describes a specific project, in rail engineering, where the notion of a human factors case has been employed to analyse engineering functions and related human factors issues. A human factors issues register for potential system disturbances has been developed, prior to a human factors risk assessment, which jointly covers safety and production (engineering delivery) concerns. The paper concludes with a commentary on the potential relevance of a resilience engineering perspective to understanding rail engineering systems risk. Design, planning and management of complex systems will increasingly have to address the issue of making trade-offs between safety and production, and ergonomics should be central to this. The paper addresses the relevant issues and does so in an under-published domain – rail systems engineering work.
Resumo:
This paper presents new methodology for making Bayesian inference about dy~ o!s for exponential famiIy observations. The approach is simulation-based _~t> use of ~vlarkov chain Monte Carlo techniques. A yletropolis-Hastings i:U~UnLlllll 1::; combined with the Gibbs sampler in repeated use of an adjusted version of normal dynamic linear models. Different alternative schemes are derived and compared. The approach is fully Bayesian in obtaining posterior samples for state parameters and unknown hyperparameters. Illustrations to real data sets with sparse counts and missing values are presented. Extensions to accommodate for general distributions for observations and disturbances. intervention. non-linear models and rnultivariate time series are outlined.
Resumo:
CONTEXTO: A síndrome de Alport é responsável por aproximadamente 5% dos pacientes com insuficiência renal crônica. Nessa doença, anormalidades no sistema de condução cardíaco são mais freqüentes que na população em geral. OBJETIVO: Relatar caso de síndrome de Alport que desenvolveu bloqueio atrioventricular total durante um transplante renal. RELATO DE CASO: Paciente masculino, 21 anos de idade, com insuficiência renal crônica secundária à síndrome de Alport, foi submetido a transplante renal sob anestesia peridural. Durante o procedimento anestésico-cirúrgico apresentou bloqueio atrioventricular total, que foi tratado rapidamente, e com sucesso, usando-se um marcapasso transcutâneo. O bloqueio simpático extenso pode contribuir para o desenvolvimento de distúrbios no sistema de condução cardíaco, particularmente em pacientes com insuficiência renal crônica em esquema de diálise. Mesmo em pacientes com eletrocardiograma pré-operatório normal e sem distúrbios de condução, graus variáveis de bloqueio atrioventricular, incluindo bloqueio atrioventricular total, podem ocorrer. Nesse caso, o uso de marcapasso transcutâneo é tratamento rápido e efetivo na sala de operação até o final da cirurgia, quando o tratamento definitivo pode ser planejado.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Wind power based generation has been rapidly growing world-wide during the recent past. In order to transmit large amounts of wind power over long distances, system planners may often add series compensation to existing transmission lines owing to several benefits such as improved steady-state power transfer limit, improved transient stability, and efficient utilization of transmission infrastructure. Application of series capacitors has posed resonant interaction concerns such as through subsynchronous resonance (SSR) with conventional turbine-generators. Wind turbine-generators may also be susceptible to such resonant interactions. However, not much information is available in literature and even engineering standards are yet to address these issues. The motivation problem for this research is based on an actual system switching event that resulted in undamped oscillations in a 345-kV series-compensated, typical ring-bus power system configuration. Based on time-domain ATP (Alternative Transients Program) modeling, simulations and analysis of system event records, the occurrence of subsynchronous interactions within the existing 345-kV series-compensated power system has been investigated. Effects of various small-signal and large-signal power system disturbances with both identical and non-identical wind turbine parameters (such as with a statistical-spread) has been evaluated. Effect of parameter variations on subsynchronous oscillations has been quantified using 3D-DFT plots and the oscillations have been identified as due to electrical self-excitation effects, rather than torsional interaction. Further, the generator no-load reactance and the rotor-side converter inner-loop controller gains have been identified as bearing maximum sensitivity to either damping or exacerbating the self-excited oscillations. A higher-order spectral analysis method based on modified Prony estimation has been successfully applied to the field records identifying dominant 9.79 Hz subsynchronous oscillations. Recommendations have been made for exploring countermeasures.
Resumo:
We have recently characterized a cardiac model of ventricular chamber defects in retinoid X receptor alpha (RXR alpha) homozygous mutant (-/-) gene-targeted mice. These mice display generalized edema, ventricular chamber hypoplasia, and muscular septal defects, and they die at embryonic day 15. To substantiate our hypothesis that the embryos are dying of cardiac pump failure, we have used digital bright-field and fluorescent video microscopy and in vivo microinjection of fluorescein-labeled albumin to analyze cardiac function. The affected embryos showed depressed ventricular function (average left ventricular area ejection fraction, 14%), ventricular septal defects, and various degrees of atrioventricular block not seen in the RXR alpha wild-type (+/+) and heterozygous (+/-) littermates (average left ventricular area ejection fraction, 50%). The molecular mechanisms involved in these ventricular defects were studied by evaluating expression of cardiac-specific genes known to be developmentally regulated. By in situ hybridization, aberrant, persistent expression of the atrial isoform of myosin light chain 2 was identified in the ventricles. We hypothesize that retinoic acid provides a critical signal mediated through the RXR alpha pathway that is required to allow progression of development of the ventricular region of the heart from its early atrial-like form to the thick-walled adult ventricle. The conduction system disturbances found in the RXR alpha -/- embryos may reflect a requirement of the developing conduction system for the RXR alpha signaling pathway, or it may be secondary to the failure of septal development.
Resumo:
v.2. Unbalances and system disturbances.
Resumo:
Introduction: The circadian system has neural projections for the Autonomic Nervous System (ANS), directly interfering with sympathetic-vagal modulation of the cardiovascular system. Disturbances in the circadian system, such as phase changes in light-dark cycle (LD), has been related to the risk of development of cardiovascular diseases due to increased sympathetic tone and reduction o Heart Rate Variability (HRV - RR intervals). Purpose: Investigate the interaction between Circadian Timing System and cardiac autonomic control in rats. Materials and methods: We used 18 Wistar rats (♀, age = 139.9 ± 32.1 days, weight = 219.5 ± 16.2 g), divided into three distinct groups: Control (CG), phase delay of 6h (GDe) and phase advance of 6h (GAd). Three animals were excluded during data collection (CG/GDe/GAd - n=5). Telemeters were surgically implanted in each animal for continuous acquisition of electrocardiographic (ECG) signals (duration of 21 days in the CG and 28 days in GDe/ GAd). A LD cycle was established 12h: 12h, beginning of light at18:00h and dark at 06:00h. The animals remained in the same CG LD cycle throughout the experimental period, while, on the 14th day of registration, the GDe and GAd underwent a delay and an advance in 6h, respectively. Throughout the experimental period, the locomotor activity (LA), the mean heart rate (mHR) and variables related to iRR [mean RR (mRR), SDNN, RMSSD, LF, HF and LF/ HF ratio ] were recorded. All data were analyzed in blocks of 3 and 7 days, for the presence of circadian rhythm, values of Cosinor - mesor, amplitude and acrophase (paired t test), phase relationship, differences between light and dark (t test independent), averages every 30 minutes along each time series (two-way ANOVA with post hoc Bonferroni). The data block B1,M1 and M2 in CG served as benchmarks for comparisons between series of analysis of the GAT/GAV. Results: We observed circadian rhythmicity in the variables LA, mRR and mFC(p<0.01). mRR and mFC showed phase relationship with the LA in all three groups, being less stable in GAd. In the CG, no significant differences between blocks were found in any of the analyzes(p>0.05). Among the 7 day blocks, there was a significant reduction in mRR(p=0.04) and mFC(p=0.03) in GDe and significant reduction in HF mean(p=0.02) in GAd; and between 3 day blocks, a significant increase of LF/HF(p= 0.04) in the GDe; besides mRR(p=0.03), SDNN(p=0.04), RMSSD (p=0.04), LF (p=0.01) and HF(p=0.02) significant increase in the GAd. It was found that the differences between the means of the mRR, LA and mFC in light and dark phases were not significant after phase changes in some of the blocks/moments (GDe and GAd). No significant results were found when comparing rhythmic variables means every 30 minutes over the blocks, except for a significant decrease in mRR at the middle of the dark phase (B2) and the start of light phase (B3) - (p<0.01). Conclusion: phase advances and delays (6h) altered cardiac autonomic control in the experimental groups by temporarily HRV decrease. Phase advances apparently had greater negative interference in this process, in relation to the phase delays.
Resumo:
Electrical disturbances such as voltage sags, interruptions and voltage unbalances might cause serious problems for the end-user and for the companies of generation and transmission of energy. Few years ago, those companies have been using methods and equipments of protection to avoid the disturbances’ presence or to mitigate their effects on the power system. Disturbances generators are used to analyse the behavior of electrical and electronic equipments affected by disturbances. The analysis of those failures allows the development of appropriated protection equipments. In this paper, the development of a disturbances generator based on power converters is presented. The disturbance generator developed is able to generate some symmetrical disturbances, such as: voltage sags, voltage swells and harmonic distortion. The control strategy used in the disturbance generator is based on discrete and repetitive control. The steps of the design of the control and of the filter used for reducing harmonic in the output, are detailed in the text. Are presented the obtained results on computational simulations and the obtained results on laboratory tests.
Resumo:
With the increasing of the distributed generation, DC microgrids have become more and more common in the electrical network. To connect devices in a microgrid, converter are necessary, but they are also source of disturbances due to their functioning. In this thesis, measurement and simulation of conducted emissions, within the frequency range 2-150kHz, of a DC/DC buck converter are studied.
Resumo:
In the last 15 years, the use of doubly fed induction machines in modern variable-speed wind turbines has increased rapidly. This development has been driven by the cost reduction as well as the low-loss generation of Insulated Gate Bipolar Transistors (IGBT). According to new grid code requirements, wind turbines must remain connected to the grid during grid disturbances. Moreover, they must also contribute to voltage support during and after grid faults. The crowbar system is essential to avoid the disconnection of the doubly fed induction wind generators from the network during faults. The insertion of the crowbar in the rotor circuits for a short period of time enables a more efficient terminal voltage control. As a general rule, the activation and the deactivation of the crowbar system is based only on the DC-link voltage level of the back-to-back converters. In this context, the authors discuss the critical rotor speed to analyze the instability of doubly fed induction generators during grid faults.