162 resultados para Syringe
Resumo:
Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.
Resumo:
Background: As part of the second generation surveillance system for HIV/Aids in Switzerland, repeated cross-sectional surveys were conducted in 1993, 1994, 1996, 2000, 2006 and 2011 among attenders of all low threshold facilities (LTFs) with needle exchange programmes and/or supervised drug consumption rooms for injection or inhalation. The number of syringes distributed to the injectors has also been measured annually since 2000. Distribution in other settings, such as pharmacies, is also monitored nationally. Methods: Periodic surveys of LTFs have been conducted using an interviewer/self-administered questionnaire structured along four themes: socio-demographic characteristics, drug consumption, risk/preventive behaviour and health. Analysis is restricted to attenders who had injected drugs during their lifetime (IDU´s). Pearson's chi-square test and trend analysis were conducted on annual aggregated data. Trend significance was assessed using Stata's non parametric test nptrend. Results: Median age of IDU´s increased from 26 years in 1993 to 40 in 2011; most are men (78%). Total yearly number of syringes distributed by LTFs has decreased by 44% in 10 years. Use of cocaine has increased (Table 1). Injection, regular use of heroin and borrowing of syringes/needles have decreased, while sharing of other material remains stable. There are fewer new injectors; more IDU´s report substitution treatment. Most attenders had ever been tested for HIV (90% in 1993, 94% in 2011). Reported prevalence of HIV remained stable around 10%; that of HCV decreased from 62% in 2000 to 42% in 2011. Conclusions: Overall, findings indicate a decrease in injection as a means of drug consumption in that population. This interpretation is supported by data from other sources, such as a national decrease in distribution from other delivery points. Switzerland's behavioural surveillance system is sustainable and allows the HIV epidemic to be monitored among this hard-to-reach population, providing information for planning and evaluation.
Resumo:
This report summarises data that is collected on the operation of the Northern Ireland Needle and Syringe Exchange Scheme (NSES). It relates to the twelve-month period between 1st April 2013 and 31st March 2014. The anonymised data is collected by the 14 pharmacies and 1 Trust-based service that participate in the Northern Ireland Needle and Syringe Exchange Scheme (NSES) which was introduced in April 2001.
Resumo:
BACKGROUND: Measuring syringe availability and coverage is essential in the assessment of HIV/AIDS risk reduction policies. Estimates of syringe availability and coverage were produced for the years 1996 and 2006, based on all relevant available national-level aggregated data from published sources. METHODS: We defined availability as the total monthly number of syringes provided by harm reduction system divided by the estimated number of injecting drug users (IDU), and defined coverage as the proportion of injections performed with a new syringe, at national level (total supply over total demand). Estimates of supply of syringes were derived from the national monitoring system, including needle and syringe programmes (NSP), pharmacies, and medically prescribed heroin programmes. Estimates of syringe demand were based on the number of injections performed by IDU derived from surveys of low threshold facilities for drug users (LTF) with NSP combined with the number of IDU. This number was estimated by two methods combining estimates of heroin users (multiple estimation method) and (a) the number of IDU in methadone treatment (MT) (non-injectors) or (b) the proportion of injectors amongst LTF attendees. Central estimates and ranges were obtained for availability and coverage. RESULTS: The estimated number of IDU decreased markedly according to both methods. The MT-based method (from 14,818 to 4809) showed a much greater decrease and smaller size of the IDU population compared to the LTF-based method (from 24,510 to 12,320). Availability and coverage estimates are higher with the MT-based method. For 1996, central estimates of syringe availability were 30.5 and 18.4 per IDU per month; for 2006, they were 76.5 and 29.9. There were 4 central estimates of coverage. For 1996 they ranged from 24.3% to 43.3%, and for 2006, from 50.5% to 134.3%. CONCLUSION: Although 2006 estimates overlap 1996 estimates, the results suggest a shift to improved syringe availability and coverage over time.
Resumo:
BACKGROUND: The objectives of the present study were to evaluate Aids prevention in drug users attending low threshold centres providing sterile injection equipment in Switzerland, to identify the characteristics of these users, and to monitor the progress of indicators of drug-related harm. METHODS: This paper presents results from a cross-sectional survey carried out in 1994. RESULTS: The mean age of attenders was 28 years, and women represented 27% of the sample. 75% of attenders used a combination of hard drugs (heroin and cocaine). Mean duration of heroin consumption was 8 years, and of cocaine 7 years; 76% of attenders had a fixed abode, but only 34% had stable employment; 45% were being treated with methadone; 9% had shared their injection material in the last 6 months; 24% always used condoms in the case of a stable relationship, and 71% in casual relationships. In a cluster analysis constructed on the basis of multiple correspondence analysis, two distinct profiles of users emerge: highly marginalised users with a high level of consumption (21%); irregular users, better integrated socially, of which the majority are under methadone treatment (79%). CONCLUSION: Theses centres play a major role in Aids prevention. Nevertheless, efforts to improve the hygiene conditions of drug injection in Switzerland should be pursued and extended. At the same time, prevention of HIV sexual transmissions should be reinforced.
Resumo:
Ce document est la pré-publication d'un article paru dans AIDS and Behavior 2011; 15(1): 75-85 url: http://link.springer.com/journal/volumesAndIssues/10461
Resumo:
Ce manuscrit est une pré-publication d'un article paru dans The American Journal on Addictions 2010; 19(3): 231-237 url: http://onlinelibrary.wiley.com/doi/10.1111/ajad.2010.19.issue-3/issuetoc
Resumo:
Mode of access: Internet.
Resumo:
n early 2001 there was a dramatic decline in the availability of heroin in New South Wales (NSW), Australia, where previously heroin had been readily available at a low price and high purity.1 The decline was confirmed by Australia's strategic early warning system, which revealed a reduction in heroin supply across Australia and a considerable increase in price,2 particularly from January to April 2001. This "heroin shortage" provided a natural experiment in which to examine the effect of substantial changes in price and availability on injecting drug use and its associated harms in Australia's largest heroin market,2 a setting in which harm reduction strategies were widely used. Publicly funded needle and syringe programmes were introduced to Australia in 1987, and methadone maintenance programmes, which were established in the 1970s, were significantly expanded in 1985 and again in 1999.
Resumo:
Focal points: Details of syringe driver use were collected from 11 inpatient hospice units in the West Midlands and compared with predetermined standards set by a multidisciplinary group We recorded 294 syringe driver events which complied with standards for the choice of administration site, protection of the syringe driver from light and the reason for initiation of the infusion Issues of nurse training, variability in prescribing practices, provision of written information for patients, labelling and documentation of the diluent used were all identified as areas in which compliance with standards could be improved
Resumo:
Background and objectives Central venous catheterization of the internal jugular vein is a commonly performed invasive procedure associated with a significant morbidity and even mortality. Ultrasound-guided methods have shown to significantly improve the success of the technique and are recommended by various scientific societies, including the American Society of Anesthesiologists. The aim of this report is to describe an innovative ultrasound-guided central line placement of the internal jugular vein. Technique The authors describe an innovative ultrasound-guided central line placement of the internal jugular vein based on an oblique approach – the “Syringe-Free” approach. This technique allows immediate progression of the guide wire in the venous lumen, while maintaining a real-time continuous ultrasound image. Conclusions The described method adds to the traditional oblique technique the possibility of achieving a continuous real-time ultrasound-guided venipuncture and a guide wire insertion that does not need removing the probe from the puncture field, while having a single operator performing the whole procedure.
Resumo:
The formation of reactive oxygen species (ROS) within cells causes damage to biomolecules, including membrane lipids, DNA, proteins and sugars. An important type of oxidative damage is DNA base hydroxylation which leads to the formation of 8-oxo-7,8-dihydro-29-deoxyguanosine (8-oxodG) and 5-hydroxymethyluracil (5-HMUra). Measurement of these biomarkers in urine is challenging, due to the low levels of the analytes and the matrix complexity. In order to simultaneously quantify 8-oxodG and 5-HMUra in human urine, a new, reliable and powerful strategy was optimised and validated. It is based on a semi-automatic microextraction by packed sorbent (MEPS) technique, using a new digitally controlled syringe (eVolH), to enhance the extraction efficiency of the target metabolites, followed by a fast and sensitive ultrahigh pressure liquid chromatography (UHPLC). The optimal methodological conditions involve loading of 250 mL urine sample (1:10 dilution) through a C8 sorbent in a MEPS syringe placed in the semi-automatic eVolH syringe followed by elution using 90 mL of 20% methanol in 0.01% formic acid solution. The obtained extract is directly analysed in the UHPLC system using a binary mobile phase composed of aqueous 0.1% formic acid and methanol in the isocratic elution mode (3.5 min total analysis time). The method was validated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), extraction yield, accuracy, precision and matrix effect. Satisfactory results were obtained in terms of linearity (r2 . 0.991) within the established concentration range. The LOD varied from 0.00005 to 0.04 mg mL21 and the LOQ from 0.00023 to 0.13 mg mL21. The extraction yields were between 80.1 and 82.2 %, while inter-day precision (n=3 days) varied between 4.9 and 7.7 % and intra-day precision between 1.0 and 8.3 %. This approach presents as main advantages the ability to easily collect and store urine samples for further processing and the high sensitivity, reproducibility, and robustness of eVolHMEPS combined with UHPLC analysis, thus retrieving a fast and reliable assessment of oxidatively damaged DNA.
Resumo:
A recomendação da Organização Mundial da Saúde é que todo recém nascido deva ser alimentado exclusivamente no seio materno até o sexto mês e, de forma complementar, até o segundo ano de vida. Assim, algumas técnicas são realizadas para facilitar a alimentação ao seio, dentre elas o uso do copo e, recentemente, a utilização da técnica "sonda-dedo". Tal prática é bastante controversa e há escassez de estudos na literatura sobre a descrição da técnica, sua indicação e uso. O objetivo do presente trabalho é relatar a experiência clínica para indicação e uso da técnica "sonda-dedo". A técnica "sonda-dedo" consiste no oferecimento do leite, de preferência humano, utilizando sonda gástrica conectada a uma seringa com êmbolo e fixada em dedo mínimo enluvado com fita adesiva. A sonda é posicionada na cavidade oral do recém nascido e deve servir como uma técnica de auxílio para adequação do padrão de sucção. Desta forma, sugere-se que sua indicação deve ser apenas nos casos em que seja caracterizada uma disfunção oral, seja em recém nascidos a termo ou pré-termo. Diante da avaliação específica, realizada pelo fonoaudiólogo, indica-se a técnica "sonda-dedo" com objetivo de adequar as alterações obtidas na avaliação da sucção não nutritiva ou em seio materno. Acredita-se que, para que a técnica "sonda-dedo" seja indicada como complemento do aleitamento materno, devam ser realizados novos estudos para esclarecer quais as repercussões da técnica "sonda-dedo" na prevalência do aleitamento materno e no desenvolvimento motor oral de recém nascidos.
Resumo:
The aim of this investigation was to monitor metronidazole concentrations in the gingival crevicular fluid (GCF) collected from periodontal pockets of dogs after treatment with an experimental 15% metronidazole gel. Five dogs had periodontitis induced by cotton ligatures placed subgingivally and maintained for a 30-day period. After the induction period, only pockets with 4 mm or deeper received the gel. Each pocket was filled up to the gingival margin by means of a syringe with a blunt-end needle. GCF was collected in paper strips and quantified in an electronic device before and after 15 minutes, 1 h, 6 h, 24 h and 48 h of gel administration. The GCF samples were assayed for metronidazole content by means of a high performance liquid chromatography method. Concentrations of metronidazole in the GCF of the 5 dogs (mean ± SD, in µg/mL) were 0 ± 0 before gel application and 47,185.75 ± 24,874.35 after 15 minutes, 26,457.34 ± 25,516.91 after 1 h, 24.18 ± 23.11 after 6 h, 3.78 ± 3.45 after 24 h and 3.34 ± 5.54 after 48 h. A single administration of the 15% metronidazole gel released the drug in the GCF of dogs in levels several-fold higher than the minimum inhibitory concentration for some periodontopathogens grown in subgingival biofilms for up to one hour, but metronidazole could be detected in the GCF at least 48 hours after the gel application.