895 resultados para Swan Ganz catheter


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The risk for venous thromboembolism (VTE) in medical patients is high, but risk assessment is rarely performed because there is not yet a good method to identify candidates for prophylaxis. Purpose: To perform a systematic review about VTE risk factors (RFs) in hospitalized medical patients and generate recommendations (RECs) for prophylaxis that can be implemented into practice. Data sources: A multidisciplinary group of experts from 12 Brazilian Medical Societies searched MEDLINE, Cochrane, and LILACS. Study selection: Two experts independently classified the evidence for each RF by its scientific quality in a standardized manner. A risk-assessment algorithm was created based on the results of the review. Data synthesis: Several VTE RFs have enough evidence to support RECs for prophylaxis in hospitalized medical patients (eg, increasing age, heart failure, and stroke). Other factors are considered adjuncts of risk (eg, varices, obesity, and infections). According to the algorithm, hospitalized medical patients ≥40 years-old with decreased mobility, and ≥1 RFs should receive chemoprophylaxis with heparin, provided they don't have contraindications. High prophylactic doses of unfractionated heparin or low-molecular-weight-heparin must be administered and maintained for 6-14 days. Conclusions: A multidisciplinary group generated evidence-based RECs and an easy-to-use algorithm to facilitate VTE prophylaxis in medical patients. © 2007 Rocha et al, publisher and licensee Dove Medical Press Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background In patients with advanced non-ischemic cardiomyopathy (NIC), right-sided cardiac disturbances has prognostic implications. Right coronary artery (RCA) flow pattern and flow reserve (CFR) are not well known in this setting. The purpose of this study was to assess, in human advanced NIC, the RCA phasic flow pattern and CFR, also under right-sided cardiac disturbances, and compare with left coronary circulation. As well as to investigate any correlation between the cardiac structural, mechanical and hemodynamic parameters with RCA phasic flow pattern or CFR. Methods Twenty four patients with dilated severe NIC were evaluated non-invasively, even by echocardiography, and also by cardiac catheterization, inclusive with Swan-Ganz catheter. Intracoronary Doppler (Flowire) data was obtained in RCA and left anterior descendent coronary artery (LAD) before and after adenosine. Resting RCA phasic pattern (diastolic/systolic) was compared between subgroups with and without pulmonary hypertension, and with and without right ventricular (RV) dysfunction; and also with LAD. RCA-CFR was compared with LAD, as well as in those subgroups. Pearson's correlation analysis was accomplished among echocardiographic (including LV fractional shortening, mass index, end systolic wall stress) more hemodynamic parameters with RCA phasic flow pattern or RCA-CFR. Results LV fractional shortening and end diastolic diameter were 15.3 ± 3.5 % and 69.4 ± 12.2 mm. Resting RCA phasic pattern had no difference comparing subgroups with vs. without pulmonary hypertension (1.45 vs. 1.29, p = NS) either with vs. without RV dysfunction (1.47 vs. 1.23, p = NS); RCA vs. LAD was 1.35 vs. 2.85 (p < 0.001). It had no significant correlation among any cardiac mechanical or hemodynamic parameter with RCA-CFR or RCA flow pattern. RCA-CFR had no difference compared with LAD (3.38 vs. 3.34, p = NS), as well as in pulmonary hypertension (3.09 vs. 3.10, p = NS) either in RV dysfunction (3.06 vs. 3.22, p = NS) subgroups. Conclusion In patients with chronic advanced NIC, RCA phasic flow pattern has a mild diastolic predominance, less marked than in LAD, with no effects from pulmonary artery hypertension or RV dysfunction. There is no significant correlation between any cardiac mechanical-structural or hemodynamic parameter with RCA-CFR or RCA phasic flow pattern. RCA flow reserve is still similar to LAD, independently of those right-sided cardiac disturbances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

FUNDAMENTO: A avaliação clínico-hemodinâmica à beira do leito e o uso do cateter de artéria pulmonar para a estimativa de dados hemodinâmicos têm sido utilizados na insuficiência cardíaca descompensada. Entretanto, não existem dados com o uso da monitorização hemodinâmica contínua não invasiva. OBJETIVO: Comparar as medidas obtidas com a monitorização hemodinâmica não invasiva com as invasivas em pacientes com insuficiência cardíaca descompensada e refratária ao tratamento. MÉTODOS: As medidas hemodinâmicas não invasivas foram obtidas através da monitorização contínua da pressão arterial sistêmica pelo modelo de ondas de pulso (modelflow) e foram comparadas com as medidas obtidas pela passagem do cateter de artéria pulmonar, simultaneamente. RESULTADOS: Foram realizadas 56 medidas em 14 pacientes estudados em dias e horários diferentes. O índice de correlação entre as medidas da pressão arterial sistólica foi de r = 0,26 (IC 95% = 0,00 a 0,49, p = 0,0492) e da diastólica de r = 0,50 (IC 95% = 0,27 a 0,67, p < 0,0001). A correlação foi de r = 0,55 (IC 95% = 0,34 a 0,71, p 0,0001) para o índice cardíaco e de r = 0,32 (IC 95% = 0,06 a 0,53, p = 0,0178) para a resistência vascular sistêmica. CONCLUSÃO: Houve correlação entre as medidas hemodinâmicas não invasivas quando comparadas às medidas do cateter de artéria pulmonar. A monitorização hemodinâmica contínua não invasiva pode ser útil para pacientes internados com insuficiência cardíaca descompensada.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulmonary capillary pressure (Pcap) is the predominant force that drives fluid out of the pulmonary capillaries into the interstitium. Increasing hydrostatic capillary pressure is directly proportional to the lung's transvascular filtration rate, and in the extreme leads to pulmonary edema. In the pulmonary circulation, blood flow arises from the transpulmonary pressure gradient, defined as the difference between pulmonary artery (diastolic) pressure and left atrial pressure. The resistance across the pulmonary vasculature consists of arterial and venous components, which interact with the capacitance of the compliant pulmonary capillaries. In pathological states such as acute respiratory distress syndrome, sepsis, and high altitude or neurogenic lung edema, the longitudinal distribution of the precapillary arterial and the postcapillary venous resistance varies. Subsequently, the relationship between Pcap and pulmonary artery occlusion pressure (PAOP) is greatly variable and Pcap can no longer be predicted from PAOP. In clinical practice, PAOP is commonly used to guide fluid therapy, and Pcap as a hemodynamic target is rarely assessed. This approach is potentially misleading. In the presence of a normal PAOP and an increased pressure gradient between Pcap and PAOP, the tendency for fluid leakage in the capillaries and subsequent edema development may substantially be underestimated. Tho-roughly validated methods have been developed to assess Pcap in humans. At the bedside, measurement of Pcap can easily be determined by analyzing a pressure transient after an acute pulmonary artery occlusion with the balloon of a Swan-Ganz catheter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The study sought to evaluate the ability of cardiac magnetic resonance (CMR) to monitor acute and long-term changes in pulmonary vascular resistance (PVR) noninvasively. Background PVR monitoring during the follow-up of patients with pulmonary hypertension (PH) and the response to vasodilator testing require invasive right heart catheterization. Methods An experimental study in pigs was designed to evaluate the ability of CMR to monitor: 1) an acute increase in PVR generated by acute pulmonary embolization (n = 10); 2) serial changes in PVR in chronic PH (n = 22); and 3) changes in PVR during vasodilator testing in chronic PH (n = 10). CMR studies were performed with simultaneous hemodynamic assessment using a CMR-compatible Swan-Ganz catheter. Average flow velocity in the main pulmonary artery (PA) was quantified with phase contrast imaging. Pearson correlation and mixed model analysis were used to correlate changes in PVR with changes in CMR-quantified PA velocity. Additionally, PVR was estimated from CMR data (PA velocity and right ventricular ejection fraction) using a formula previously validated. Results Changes in PA velocity strongly and inversely correlated with acute increases in PVR induced by pulmonary embolization (r = –0.92), serial PVR fluctuations in chronic PH (r = –0.89), and acute reductions during vasodilator testing (r = –0.89, p ≤ 0.01 for all). CMR-estimated PVR showed adequate agreement with invasive PVR (mean bias –1.1 Wood units,; 95% confidence interval: –5.9 to 3.7) and changes in both indices correlated strongly (r = 0.86, p < 0.01). Conclusions CMR allows for noninvasive monitoring of acute and chronic changes in PVR in PH. This capability may be valuable in the evaluation and follow-up of patients with PH.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: El monitoreo hemodinámico es una herramienta para diagnosticar el choque cardiogénico y monitorear la respuesta al tratamiento; puede ser invasivo, mínimamente invasivo o no invasivo. Se realiza rutinariamente con catéter de arteria pulmonar (CAP) o catéter de Swan Ganz; nuevas técnicas de monitoreo hemodinámico mínimamente invasivo tienen menor tasa de complicaciones. Actualmente se desconoce cuál técnica de monitoreo cuenta con mayor seguridad en el paciente con choque cardiogénico. Objetivo: Evaluar la seguridad del monitoreo hemodinámico invasivo comparado con el mínimamente invasivo en pacientes con choque cardiogénico en cuidado intensivo adultos. Diseño: Revisión sistemática de la literatura. Búsqueda en Pubmed, EMBASE, OVID - Cochrane Library, Lilacs, Scielo, registros de ensayos clínicos, actas de conferencias, repositorios, búsqueda de literatura gris en Google Scholar, Teseo y Open Grey hasta agosto de 2016, publicados en inglés y español. Resultados: Se identificó un único estudio con 331 pacientes críticamente enfermos que comparó el monitoreo hemodinámico con CAP versus PiCCO que concluyó que después de la corrección de los factores de confusión, la elección del tipo de monitoreo no influyó en los resultados clínicos más importantes en términos de complicaciones y mortalidad. Dado que se incluyeron otros diagnósticos, no es posible extrapolar los resultados sólo a choque cardiogénico. Conclusión: En la literatura disponible no hay evidencia de que el monitoreo hemodinámico invasivo comparado con el mínimamente invasivo, en pacientes adultos críticamente enfermos con choque cardiogénico, tenga diferencias en cuanto a complicaciones y mortalidad.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An observational study was conducted in a SICU to determine the frequency of subclavian vein catheter-related infection at 72 hours, to identify the hospital cost of exchange via a guidewire and the estimated hospital cost-savings of a 72 hour vs 144 hour exchange policy.^ An overall catheter-related infection ($\geq$15 col. by Maki's technique (1977)) occurred in 3% (3/100) of the catheter tips cultured. Specific infections rates were: 9.7% (3/31) for triple lumen catheters, 0% (0/30) for Swan-Ganz catheters, 0% (0/30) for Cordes catheters, and 0% (0/9) for single lumen catheters.^ An estimated annual hospital cost-savings of $35,699.00 was identified if exchange of 72 hour policy were changed to every 144 hours.^ It was recommended that a randomized clinical trial be conducted to determine the effect of changing a subclavian vein catheter via a guidewire every 72 hours vs 144 hours. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La ecografía básica cardiaca (ECB) es una herramienta útil en la Unidad de Cuidados intensivos al facilitar la realización de ciertas intervenciones. No se ha definido el número de repeticiones necesarias para obtener un nivel de competencia adecuado. La evidencia encontrada indica un número mínimo de cincuenta repeticiones, para alcanzar cierto grado de habilidad.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catheter-related bloodstream infections are a serious problem. Many interventions reduce risk, and some have been evaluated in cost-effectiveness studies. We review the usefulness and quality of these economic studies. Evidence is incomplete, and data required to inform a coherent policy are missing. The cost-effectiveness studies are characterized by a lack of transparency, short time-horizons, and narrow economic perspectives. Data quality is low for some important model parameters. Authors of future economic evaluations should aim to model the complete policy and not just single interventions. They should be rigorous in developing the structure of the economic model, include all relevant economic outcomes, use a systematic approach for selecting data sources for model parameters, and propagate the effect of uncertainty in model parameters on conclusions. This will inform future data collection and improve our understanding of the economics of preventing these infections.