998 resultados para Surgical Mesh


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To study the biocompatibility of surgical meshes for use in pelvic reconstructive surgery using an animal model. Eight different types of mesh: Atrium, Dexon, Gynemesh, IVS tape, Prolene, SPARC tape, TVT tape and Vypro II, were implanted into the abdominal walls of rats for 3 months' duration. Explanted meshes were assessed, using light microscopy, for parameters of rejection and incorporation. Type 1 (Atrium, Gynemesh, Prolene, SPARC and TVT) and type 3 (Vypro II, Dexon and IVS) meshes demonstrated different biocompatible properties. Inflammatory cellular response and fibrosis at the interface of mesh and host tissue was most marked with Vypro II and IVS. All type 1 meshes displayed similar cellular responses despite markedly different mesh architecture. The inflammatory response and fibrous reaction in the non-absorbable type 3 meshes tested (IVS and Vypro II) was more marked than the type 1 meshes. The increased inflammatory and fibrotic response may be because of the multifilamentous polypropylene components of these meshes. Material and filament composition of mesh is the main factor in determining cellular response.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: Incisional hernia (IH) is one of the most frequent postoperative complications. Of all patients undergoing IH repair, a vast amount have a hernia which can be defined as a large incisional hernia (LIH). The aim of this study is to identify the preferred technique for LIH repair. METHODS: A systematic review of the literature was performed and studies describing patients with IH with a diameter of 10 cm or a surface of 100 cm2 or more were included. Recurrence hazards per year were calculated for all techniques using a generalized linear model. RESULTS: Fifty-five articles were included, containing 3,945 LIH repairs. Mesh reinforced techniques displayed better recurrence rates and hazards than techniques without mesh reinforcement. Of all the mesh techniques, sublay repair, sandwich technique with sublay mesh and aponeuroplasty with intraperitoneal mesh displayed the best results (recurrence rates of <3.6%, recurrence hazard <0.5% per year). Wound complications were frequent and most often seen after complex LIH repair. CONCLUSIONS: The use of mesh during LIH repair displayed the best recurrence rates and hazards. If possible mesh in sublay position should be used in cases of LIH repair.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJETIVO: Comparar duas técnicas de tratamento da hérnia incisional em coelhos utilizando a tela de polipropileno apoiando um reforço peritônio - aponeurótico ou suturada nas bordas do anel herniário 'em ponte . MÉTODOS: Foram operados 60 coelhos para a produção de hérnia incisional, em uma incisão mediana de 4 centímetros. Após 30 dias, metade dos animais foram operados com o fechamento primário da parede, com colocação de uma tela de polipropileno apoiando o reforço e a outra metade dos animais com a colocação da tela suturada nas bordas do anel herniárioem ponte . Os animais foram avaliados com 30 (M1), 60 (M2)e 90 (M3) dias de pós-operatório. Os parâmetros analisados foram a evolução clínica, análise da força de ruptura da cicatriz, estudo macroscópico, análise microscópica e morfométrica. RESULTADOS: Não foram observadas diferenças significantes com relação a força de ruptura e estudos histológicos nos dois grupos e vários momentos estudados. Não houve diferença estatística com relação às complicações, embora os animais que receberam a telaem ponte tiveram aderências mais firmes e intensas à parede abdominal. CONCLUSÕES: As duas técnicas utilizadas para correção da hérnia incisional em coelhos não mostraram diferenças significantes quanto a força de ruptura, análise histológica e morfométrica. O número de complicações foi semelhante, porém a aderência de órgãos da cavidade abdominal à área de cicatriz foi muito mais intensa no grupo em que a tela foi colocadaem ponte .

Relevância:

70.00% 70.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background We sought to determine whether or not there are differences in disease progression after radical or nonradical (debulking) surgical procedures for malignant pleural mesothelioma. Methods Over a 49-month period, 132 patients with malignant pleural mesothelioma underwent surgery. Fifty-three underwent extrapleural pneumonectomy and 79 underwent nonradical procedures. Time to evidence of clinical disease progression was recorded, as was the site(s) of that disease. Results One-hundred nineteen patients were evaluable, of which 59% (22 radical; 48 nonradical) had disease progression. Overall 30-day mortality was 8.5% (7.5% radical; 9% nonradical). The median time to overall disease progression was considerably longer after extrapleural pneumonectomy than debulking surgery (319 days vs 197 days, p = 0.019), as was the time to local disease progression (631 days vs 218 days, p = 0.0018). There was no preponderance of earlier stage disease in the radical surgery group. There was a trend toward prolonged survival in those undergoing radical surgery, but no significant difference between the groups (497 days vs 324 days, p = 0.079). In those who had extrapleural pneumonectomy, time-to-disease progression significantly decreased with N2 disease compared with N0/1 involvement (197 days vs 358 days, p = 0.02). Conclusions Extrapleural pneumonectomy may be preferable to debulking surgery in malignant pleural mesothelioma to delay disease progression and give greater control of local disease. Involvement of N2 nodes is associated with accelerated disease progression and is therefore a contraindication to extrapleural pneumonectomy. © 2004 by The Society of Thoracic Surgeons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective is to alert the surgeon about the indiscriminate use of synthetic prosthesis in the correction of inguinal and incisional hernias. The authors provide a brief history of surgery on hernias and a review of the literature, showing the importance of classifying inguinal hernias to fit the type of surgical correction with the defect found, abstaining from treating all hernias, with the same type of surgical procedure. In our opinion, small indirect inguinal hernias (type 1 and 2 of Gilbert) and hernias in women must not, in general, be treated with prostheses. The synthetic material should be reserved for direct and large indirect hernias. Even so, this attitude, besides determining a higher cost for the procedure, can lead to important complications such as infection, rejection, fistula formation, chronic pain, alterations in spermatogenesis and the possibility of carcinogenesis, according to more recent reports. The physiology and anatomy of the abdominal wall should be considered when dealing with incisional hernia corrections, where the surgeon can choose among many techniques to correct those defects, and in selected cases, utilize synthetic material. We conclude that although the use of biomaterials has constituted a great advance in surgery for abdominal wall hernia corrections because they decrease recurrences, and permit treatment of large abdominal hernias, the indiscriminate prosthesis usage is an abuse, and it can determine many serious complications, certainly avoidable with a well indicated non mesh technique .

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simulation-based training system for surgical wound debridement was developed and comprises a multimedia introduction, a surgical simulator (tutorial component), and an assessment component. The simulator includes two PCs, a haptic device, and mirrored display. Debridement is performed on a virtual leg model with a shallow laceration wound superimposed. Trainees are instructed to remove debris with forceps, scrub with a brush, and rinse with saline solution to maintain sterility. Research and development issues currently under investigation include tissue deformation models using mass-spring system and finite element methods; tissue cutting using a high-resolution volumetric mesh and dynamic topology; and accurate collision detection, cutting, and soft-body haptic rendering for two devices within the same haptic space.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: It is recognized that chronic inflammation can cause cancer. Even though most of the available synthetic meshes are considered non-carcinogenic, the inflammatory response to an infected mesh plays a constant aggression to the skin. Chronic mesh infection is frequently the result of misuse of mesh, and due to the challenging nature of this condition, patients usually suffer for years until the infected mesh is removed by surgical excision. Methods: We report two cases of squamous-cell carcinoma (SCC) of the abdominal wall, arising in patients with long-term mesh infection. Results: In both patients, the degeneration of mesh infection into SCC was presumably caused by the long-term inflammation secondary to infection. Patients presented with advanced SCC behaving just like the Marjolin's ulcers of burns. Radical surgical excision was the treatment of choice. The involvement of the bowel played an additional challenge in case 1, but it was possible to resect the tumor and the involved bowel and reconstruct the abdominal wall using polypropylene mesh as onlay reinforcement, in a single stage operation. He is now under adjuvant chemotherapy. The big gap in the midline after tumor resection in case 2 required mesh bridging to close the defect. The poor prognosis of case 2 who died months after the operation, and the involvement of the armpit, groin and mesenteric nodes in case 1 shows how aggressive this disease can be. Conclusion: Infected mesh must be treated early, by complete excision of the mesh. Long-standing mesh infection can degenerate into aggressive squamous-cell carcinoma of the skin. © 2013 Springer-Verlag France.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the efficacy and safety of traumatic orbital defect reconstruction with titanium mesh. A retrospective study was made. Evaluations were made after a minimum postoperative follow-up of 12 months, looking for the main complications. Twenty-four patients were included in this evaluation; 19 were male (79.1%) and 5 (20.8%) were female. The main injury etiology was vehicle accidents (50%) followed by other causes. Fourteen patients (58.3%) presented orbital floor fractures, and 10 had more than one wall fractured (41.6%). Permanent infraorbital nerve hypoesthesia was observed in two patients (8.3%), enophthalmos occurred in five patients (20.8%), and exophthalmos was found in two patients (8.3%). Four patients (16.6%) still presented evidence of residual prolapsed intraorbital content, and one of those needed further surgical correction; sinusitis occurred in one patient (4.1%). Titanium mesh is a reliable option for orbital reconstruction, despite some complications found in this sample.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prosthetic meshes are commonly used to correct abdominal wall defects. However, the inflammatory reaction induced by these devices in the peritoneum is not completely understood. We hypothesized that nitric oxide (NO), produced by nitric oxide synthase 2 (NOS2) may modulate the response induced by mesh implants in the abdominal wall and, consequently, affect the outcome of the surgical procedure. Polypropylene meshes were implanted in the peritoneal side of the abdominal wall in wild-type and NOS2-deficient (NOS2(-/-)) mice. After 15 days tissues around the mesh implant were collected, and inflammatory markers (the cytokine interleukin 1 beta (IL-1 beta) and NO) and tissue remodeling (collagen and metalloproteinases (MMP) 2 and 9) were analyzed. The lack of NOS2-derived NO induced a higher incidence of visceral adhesions at the mesh implantation site compared with wild-type mice that underwent the same procedure (P < 0.05). Additionally, higher levels of IL-1 beta were present in the mesh-implanted NOS2(-/-) animals compared with control and wild-type mice. Mesh implantation induced collagen I and III deposition, but in smaller amounts in NOS2(-/-) mice. MMP-9 activity after the surgical procedure was similarly increased in both groups. Conversely, MMP-2 activity was unchanged in mesh-implanted wild-type mice, but was significantly increased in NOS2(-/-) mice (P < 0.01), due to decreased S-nitrosylation of the enzyme in these animals. We conclude that NOS2-derived NO is crucial for an adequate response to and integration of polypropylene mesh implants in the peritoneum. NO deficiency results in a prolonged inflammatory reaction to the mesh implant, and reduced collagen deposition may contribute to an increased incidence of visceral adhesions. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mesh fixation during laparoscopic ventral hernia repair can be performed using transfascial sutures or metal tacks. The aim of the present study is to compare mesh shrinkage and pain between two different techniques of mesh fixation in a prospective randomized trial.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Genital prolapse is frequent and can be found in about 50% of parous women. Its etiology is complex and multifactorial. Predisposing factors include: genetics (connective tissue disorders, family history); general state (age, parity, weight, smoking, obstructive pulmonary disease); trauma (carrying heavy loads, intense physical exercise); or iatrogenic (post hysterectomy). Treatment can be conservative or surgical and depends mainly on the severity of symptoms. Developments in surgical techniques and synthetic material in the last 20 years enabled us to use minimally invasive procedures with improved post operative course and decreased recurrence rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Postoperative fascial dehiscence and open abdomen are severe postoperative complications and are associated with surgical site infections, fistula, and hernia formation at long-term follow-up. This study was designed to investigate whether intraperitoneal implantation of a composite prosthetic mesh is feasible and safe.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study reports on 15 mandibular reconstructions using the Dumbach Titan Mesh-System and particulate cancellous bone and marrow harvested from bilateral posterior ilia. All cases showed segmental defects. Eleven cases involved patients with malignant tumor. Six patients had received irradiation of 40-50 Gy. Reconstructions were performed immediately in 1 patient and secondarily in the remaining 14 patients. In 13 cases, mandibles were successfully reconstructed. Of these 13 patients, 9 reconstructions were completed without complications, whereas the other 4 cases showed complications. In 2 cases, reconstruction failed completely. Overall success rate was 87%. Statistical analysis revealed the extent of mandibular defect, but not malignancy of the original disease or radiotherapy of mesh using a 3-dimensional skull model is expected to improve surgical outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Patients with peritonitis undergoing emergency laparotomy are at increased risk for postoperative open abdomen and incisional hernia. This study aimed to evaluate the outcome of prophylactic intraperitoneal mesh implantation compared with conventional abdominal wall closure in patients with peritonitis undergoing emergency laparotomy. METHOD: A matched case-control study was performed. To analyze a high-risk population for incisional hernia formation, only patients with at least two of the following risk factors were included: male sex, body mass index (BMI) >25 kg/m(2), malignant tumor, or previous abdominal incision. In 63 patients with peritonitis, a prophylactic nonabsorbable mesh was implanted intraperitoneally between 2005 and 2010. These patients were compared with 70 patients with the same risk factors and peritonitis undergoing emergency laparotomy over a 1-year period (2008) who underwent conventional abdominal closure without mesh implantation. RESULTS: Demographic parameters, including sex, age, BMI, grade of intraabdominal infection, and operating time were comparable in the two groups. Incidence of surgical site infections (SSIs) was not different between groups (61.9 vs. 60.3 %; p = 0.603). Enterocutaneous fistula occurred in three patients in the mesh group (4.8 %) and in two patients in the control group (2.9 %; p = 0.667). The incidence of incisional hernia was significantly lower in the mesh group (2/63 patients) than in the control group (20/70 patients) (3.2 vs. 28.6 %; p < 0.001). CONCLUSIONS: Prophylactic intraperitoneal mesh can be safely implanted in patients with peritonitis. It significantly reduces the incidence of incisional hernia. The incidences of SSI and enterocutaneous fistula formation were similar to those seen with conventional abdominal closure.