988 resultados para Surgery, Experimental


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Also published Baltimore. Williams & Wilkins Company, 1949.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The main mode of failure of the acetabular component in total hip arthroplasty is aseptic loosening. Successive generations of cementation techniques have evolved to alleviate this problem.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Myocardial depression after cardiac surgery is modulated by cardiopulmonary bypass (CPB) and the underlying heart disease. The sodium pump is a key component for myocardial function. We hypothesized that the change in sodium pump expression during CPB correlates with intraoperative and postoperative laboratory and clinical parameters in neonates and children with various congenital heart defects. Sodium pump isoforms alpha1 (ATP1A1) and alpha3 (ATP1A3) mRNA expression in right atrial myocardium, excised before and after CPB, was quantified. Groups were assigned according to presence (VO group, n = 8) or absence (NO group, n = 8) of right atrial volume overload. CPB and aortic clamp time correlated with postoperative troponin-I values and ICU stay. ATP1A1 (P = 0.008) and ATP1A3 (P = 0.038) mRNA expression were significantly reduced during CPB. Longer aortic clamp times were associated with lower postoperative ATP1A1 (P = 0.045) and ATP1A3 (P = 0.002) mRNA expression. Low postoperative ATP1A1 (P = 0.043) and ATP1A3 (P = 0.002) expressions were associated with high troponin-I values. These results were restricted to the VO group. No correlation of sodium pump mRNA expression was found with the duration of ICU stay or ventilation. The postoperative troponin-I and clinical parameters correlated with the length of CPB, regardless of volume overload. In contrast, only dilated right atrium seemed to be susceptible to CPB in terms of sodium pump expression, showing a reduction during the operation and a correlation of sodium pump with postoperative troponin-I values.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Bibliography: p. [537]-549.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: We describe an experimental model for transanal endorectal pull-through surgery using the method of de]a Torre and Ortega that can be used for training purposes in experimental laboratories.Methods: Ten rabbits were submitted to the transanal endorectal pull-through technique of de la Torre and Ortega. Animals were randomly selected in the Botucatu School of Medicine experimental laboratory. Animals weighted between 2800 and 4400 g. Colons were not prepared, and antibiotic therapy was not used; dipyrone(1) was administered postoperatively for analgesic purposes. We standardized resected segment size, recorded surgical time, and observed Survival and possible complications for 1 month.Results: All animals survived the initial follow-up period without infection. Bowel movements returned quickly, and all animals were evacuating regularly within the first 24 hours. Mean surgical time was 48.6 minutes.Conclusions: the experimental model proposed in this study is very useful for training and improving surgical techniques using the method of de la Torre and Ortega. The rabbit is an excellent animal for this surgery because of its size and postoperative resistance. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Compression and section of the facial nerve were performed in 48 rats in order to study the anatomopathological alterations occurring after daily intraperitoneal injections of 100 mg of exogenous gangliosides (Sinaxial®) for 45, 90, 180 days. In groups submitted to nerve compression, the histopathological changes were discrete and in the 180-day subgroups the nerve was practically normal. In animals submitted to section and neurorrhaphy there was formation of an amputation neuroma, a granuloma around the suture, axonal unstructuration and inter and perineural fibrosis. No significant differences were observed between the groups submitted or not to injection of exogenous gangliosides, indicating that the major factors involved in the quality of nerve regeneration were the technique and the formation of fibrosis and of an amputation neuroma.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AIM: To evaluate the haemostatic efficacy and the histologic tissue responses after the application of different haemostatic agents used in periradicular surgery. METHODOLOGY: The study was conducted in the calvarium of six rabbits. Standardized bone defects (diameter 4 mm) were trephined, and different haemostatic agents were applied and compared with control defects: bone wax (left for 10 min), Stasis (ferric sulphate, left for 5 s), Expasyl (aluminium chloride, left for 2 min and left permanently in situ), and a combination of Expasyl (2 min) and Stasis (5 s). The sites were photographed before the application and after the removal of the haemostatic agents. Three independent examiners judged the initial and final bleeding (on the photographs) using a bleeding score for each site and treatment. The results were compared using Wilcoxon's signed rank test. For the histologic analysis, three animals were killed after 3 weeks and three animals after 12 weeks. Transverse, nondecalcified sections were stained with combined basic fuchsin and toluidine blue for descriptive histology. RESULTS: The most efficient haemorrhage control was provided by Expasyl in combination with Stasis and by Expasyl alone, whereas bone wax had the weakest bleeding reduction effect. The histologic analysis after 3 weeks demonstrated an inflammatory and foreign body tissue response towards all haemostatic agents. At 12 weeks, this tissue response was less pronounced but still present in sites treated with bone wax or Expasyl. In general, the inflammatory tissue reactions were limited to the bone defects, and never extended into the surrounding tissues. CONCLUSIONS: Expasyl alone or in combination with Stasis appeared to be the most efficient of tested agents to control the bleeding within the bony defects created in a rabbit calvarium model.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The 4,188-kb circular genome of Bacillus subtilis 168 was artificially dissected into two stable circular chromosomes in vivo, one being the 3,878-kb main genome and the other the 310-kb subgenome that was recovered as covalently closed circular DNA in CsCl-ethidium bromide ultracentrifugation. The minimal requirements to physically separate the 310-kb DNA segment out of the genome were two interrepeat homologous sequences and an origin of DNA replication between them. The subgenome originated from the 1,255–1,551-kb region of the B. subtilis genome was essential for the cell to survive because the subgenome was not lost from the cell. The finding that the B. subtilis genome has a potential to be divided and the resulting two replicons stably maintained may shed light on origins and formation mechanisms of giant plasmids or second chromosomes present in many bacteria. Similar excision or its reversal process, i.e., integration of large sized covalently closed circular DNA pieces into the main genome, implies significant roles of subgenomes in the exchange of genetic information and size variation of bacterial genomes in bacterial evolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background--The admission and assessment of patients for elective procedures is a task faced by all healthcare organisations that provide elective surgical services. Several different strategies have been used to facilitate the management of these tasks. Nurse-led preadmission clinics or services have been implemented in many health services as one of these management strategies; however their effectiveness has not been established. Objectives--The objective of this review was to examine the available research on the effectiveness of nurse-led elective surgery preoperative assessment clinics or services on patient outcomes.--Results--Of the 19 included articles, there were 10 audits of patient and hospital data, 3 surveys or questionnaires, 3 descriptive studies, 1 action research design, 1 prospective observational study and 1 RCT. Five of ten studies reporting data on cancellations rates found that nurse-led preadmission services reduced the number of day-of-surgery cancellations. Non-attendance for surgery was also reduced, with nine studies reporting decreases in the number of patients failing to attend. Eight studies reporting data on patient or parent satisfaction found high levels of satisfaction with nurse-led preadmission services. Three of four studies investigating the effect of the nurse-led preadmission service on patient anxiety found a reduction in reported anxiety levels. Three studies found that preoperative preparation was enhanced by the use of a nurse-led preadmission service.--Conclusions--While all included studies reported evidence of effectiveness for nurse-led preadmission services on a wide range of outcomes for elective surgery patients, the lack of experimental trials means that the level of evidence is low, and further research is needed.--Implications for practice--Nurse-led preadmission services may be an effective strategy for reducing procedural cancellations, failure to attend for procedures, and patient anxiety, however currently the evidence level is low.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: In an attempt to reduce stress shielding in the proximal femur multiple new shorter stem design have become available. We investigated the load to fracture of a new polished tapered cemented short stem in comparison to the conventional polished tapered Exeter stem. Method: A total of forty-two stems, twenty-one short stems and twenty-one conventional stems both with three different offsets were cemented in a composite sawbone model and loaded to fracture. Results: study showed that femurs will break at a significantly lower load to failure with a shorter compared to conventional length Exeter stem. Conclusion: This Both standard and short stem design are safe to use as the torque to failure is 7–10 times as much as the torques seen in activities of daily living.