9 resultados para Supress


Relevância:

10.00% 10.00%

Publicador:

Resumo:

O Sistema de Registro Eletr??nico de Ponto (SREP) representou um importante avan??o nos instrumentos de prote????o e seguran??a dos trabalhadores e empresas que utilizam o ponto eletr??nico, por coibir fraudes de altera????o dos hor??rios efetivamente registrados, de supress??o ou de impedimento na marca????o de horas extras. Ap??s investiga????o das modalidades de fraudes e dos sistemas que propiciavam as adultera????es, a equipe t??cnica do Minist??rio do Trabalho e Emprego (MTE) desenvolveu o modelo de regulamenta????o, consolidado na Portaria n?? 1.510/2009, que garante as marca????es dos hor??rios de jornada de trabalho sem possibilidade de adultera????o. O SREP ?? composto de um hardware e um software. O hardware, Registrador Eletr??nico de Ponto (REP), preserva as marca????es de ponto e fornece ao trabalhador o seu comprovante. O software opera nos computadores das empresas, permitindo o tratamento seguro dos dados para pagamento das horas trabalhadas. S?? em 2010, o SREP recuperou uma sonega????o de R$ 1,5 bilh??o em sal??rios e R$ 446,6 milh??es em contribui????es previdenci??rias e Fundo de Garantia do Tempo de Servi??o (FGTS)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os ataques de pânico (AP) podem ser precipitados pela inalação de dióxido de carbono (CO2 5%) ou pela infusão de lactato de sódio 0,5 mol/L (LAC) em pacientes predispostos, mas não nos indivíduos sadios ou pacientes com outros transtornos psiquiátricos. Estas e outras observações sugeriram que os AP sejam "alarmes falsos de sufocamento". O TP também caracteriza-se pela alta comorbidade com ansiedade de separação da infância (ASI). De fato, a ASI tem sido considerada como um fator predisponente tanto do pânico como da resistência aos panicolíticos. Estudos pré-clínicos do nosso laboratório mostraram, por outro lado, que a fluoxetina (FLX) atenua o pânico experimental à estimulação elétrica da matéria cinzenta periaquedutal dorsal (MCPAd) e à injeção de cianeto de potássio (KCN) em doses e regimes similares aos empregados na clínica. Adicionalmente, estes estudos mostraram que o isolamento social neonatal (ISN), um modelo de ASI, abole os efeitos panicolíticos da fluoxetina (1-2 mg.kg-1.dia-1, 21 dias) no modelo de pânico por estimulação da MCPAd. Portanto, o presente trabalho avaliou os efeitos da administração de 4 mg/kg de FLX (Estudo-1) e da infusão de uma solução 0,5 mol/L de LAC (Estudo-2) sobre as respostas de pânico à estimulação da MCPAd ou à injeção de KCN, respectivamente, em ratos submetidos ao isolamento social neonatal tanto efetivo (ISN) quanto fictício (ISF). No Estudo-1, ratos Wistar machos adultos submetidos ao ISN (3 h diárias) ou ao ISF (somente manipulação), ao longo da lactação, foram implantados com eletrodos na MCPAd e tratados com salina (0,9%, SAL) ou FLX (4 mg.kg-1.dia-1) ao longo de 21 dias. Nos ratos tratados com SAL, enquanto os limiares das respostas de pânico mantiveram-se praticamente inalterados no grupo ISF, eles foram progressivamente aumentados no grupo ISN. Os ratos tratados com FLX4 apresentaram limiares mais elevados que aqueles dos ratos tratados com SAL. A comparação aos limiares basais mostrou que a FLX4 teve efeitos diferenciados nos grupos ISF e ISN, aumentando ou reduzindo seus limiares, respectivamente. Embora não tenhamos observado diferenças dos efeitos da FLX4 sobre os limiares de pânico dos grupos ISN e ISF, as variações percentuais em relação à sessão de triagem indicam que a FLX4 teve efeitos até mesmo facilitadores. Estes resultados estendem observações anteriores da ausência de efeitos de doses menores de FLX nos ratos submetidos ao ISN. Por sua vez, o Estudo-2 mostrou que a infusão endovenosa de uma concentração clinicamente eficaz de LAC (0,5 mol/L) não tem efeito algum sobre o pânico induzido pelo KCN em ratos tanto virgens quanto submetidos ao ISF ou ISN. Embora os últimos resultados sugiram que os AP ao KCN (em ratos) e LAC (em humanos) envolvam mecanismos distintos, a conclusão definitiva requer experimentos adicionais com concentrações maiores de LAC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Purpose The discovery that flavonoids are capable of inhibiting platelet function has led to their investigation as potential antithrombotic agents. However, despite the range of studies on the antiplatelet properties of flavonoids, little is known about the mechanisms by which flavonoids inhibit platelet function. In this study, we aimed to explore the pharmacological effects of a polymethoxy flavonoid, nobiletin in the modulation of platelet function. Experimental Approach The ability of nobiletin to modulate platelet function was explored by using a range of in vitro and in vivo experimental approaches. Aggregation, dense granule secretion and spreading assays were performed using washed platelets. The fibrinogen binding, α-granule secretion and calcium mobilisation assays were performed using platelet-rich plasma and whole blood was used in impedance aggregometry and thrombus formation experiments. The effect of nobiletin in vivo was assessed by measuring tail bleeding time using C57BL/6 mice. Key Results Nobiletin was shown to supress a range of well-established activatory mechanisms, including platelet aggregation, granule secretion, integrin modulation, calcium mobilisation and thrombus formation. Nobiletin was shown to extend bleeding time in mice and reduce the phosphorylation of Akt and PLCγ2 within the collagen receptor (GPVI) - stimulated pathway, in addition to increasing the levels of cGMP and phosphorylation of VASP, a protein whose activity is associated with inhibitory cyclic nucleotide signalling. Conclusions and Implications This study provides insight into the underlying molecular mechanisms through which nobiletin modulates haemostasis and thrombus formation. Therefore nobiletin may represent a potential antithrombotic agent of dietary origins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In water distribution systems, old metallic pipes have been replaced by plastic pipes due to their deterioration over time. Although acoustic methods are effective in finding leaks in metallic pipes, they have been found to be problematic when applied to plastic pipes due to the high damping within the pipe wall and the surrounding medium. This is responsible for the leak signal not traveling long distances. Moreover, the leak energy in plastic pipes is generally located at a narrow frequency range located at low frequencies. However, the presence of resonances can narrow even more this frequency range. In order to minimise the influence of background noise and resonances on the calculation of the time delay estimate, band-pass filters are often used to supress undesirable frequency components of the noise. The objective of this paper is to investigate the influence of resonances in the pipe system (pipe, valves, connections and hydrants), on the time delay estimate calculated using acoustic signals. Analytical models and actual leak data collected in a bespoke rig located in the United Kingdom are used to investigate this feature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die A4-Kollaboration am Mainzer Mikrotron MAMI erforscht die Struktur des Protons mit Hilfe der elastischen Streuung polarisierter Elektronen an unpolarisiertem Wasserstoff. Bei longitudinaler Polarisation wird die paritätsverletzende Asymmetrie im Wirkungsquerschnitt gemessen, die Aufschluss über den Strangeness-Beitrag zu den Vektor-Formfaktoren des Protons gibt. Insbesondere wurde eine Messung für Rückwärtsstreuwinkel bei einer Elektronenstrahlenergie von 319 MeV durchgeführt, die zusammen mit einem unter Vorwärtsstreuung bei gleichem Impulsübertrag bestimmten Wert die Separation der magnetischen und elektrischen Strangeness-Formfaktoren erlaubt. Im Rahmen der vorliegenden Arbeit wurde ein Elektroniksystem zur Energiemessung und Histogrammierung der auftretenden Einzelereignisse aufgebaut, das eine vernetzte Struktur aus 1022 Einzelkanälen besitzt und zur Verarbeitung einer Gesamtereignisrate von 100 MHz ausgelegt wurde. Für den experimentellen Betrieb wurden für alle Kanäle erforderliche Qualitäts-prüfungen und Eichmessungen vorgenommen. Die volle Funktionsfähigkeit des Systems zur Durchführung eines Zählratenexperiments für die paritätsverletzende Asymmetrie im Bereich von 10^{-6} wurde demonstriert. Um den bei rückwärtigen Streuwinkeln dominierenden inelastischen Untergrund an Photonen in den Spektren zu reduzieren, wurde das System außerdem um ein Taggersystem für Elektronen erweitert. Das Ergebnis einer vorläufigen Analyse für die paritätsverletzende Asymmetrie im Streuquerschnitt von longitudinal polarisierten Elektronen an unpolarisierten Protonen unter Rückwärtsstreuung bei einem Viererimpulsübertrag Q^2 = 0.23 GeV^2/c^2 beträgt A{PV}=(-16.37 +- 0.93 {stat} +- 0.69 {syst}) ppm. Für die Differenz der gemessenen Asymmetrie A{PV} und der theoretischen Vorhersage ohne Strangeness A{0}=(-16.27 +- 1.22) ppm ergibt sich A{S}= A{PV} - A{0} = (-0.10+-1.68) ppm. Mit dem bereits vorliegenden Wert der Vorwärtsstreuung von A{PV} = (-5.59+- 0.57 {stat} +- 0.29 {syst}) ppm kann ein Wert für den magnetischen bzw. elektrischen Formfaktor von G{M}^s = -0.01+- 0.15 bzw. G{E}^s = 0.034 +- 0.050 ermittelt werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of digital communication systems is increasing very rapidly. This is due to lower system implementation cost compared to analogue transmission and at the same time, the ease with which several types of data sources (data, digitised speech and video, etc.) can be mixed. The emergence of packet broadcast techniques as an efficient type of multiplexing, especially with the use of contention random multiple access protocols, has led to a wide-spread application of these distributed access protocols in local area networks (LANs) and a further extension of them to radio and mobile radio communication applications. In this research, a proposal for a modified version of the distributed access contention protocol which uses the packet broadcast switching technique has been achieved. The carrier sense multiple access with collision avoidance (CSMA/CA) is found to be the most appropriate protocol which has the ability to satisfy equally the operational requirements for local area networks as well as for radio and mobile radio applications. The suggested version of the protocol is designed in a way in which all desirable features of its precedents is maintained. However, all the shortcomings are eliminated and additional features have been added to strengthen its ability to work with radio and mobile radio channels. Operational performance evaluation of the protocol has been carried out for the two types of non-persistent and slotted non-persistent, through mathematical and simulation modelling of the protocol. The results obtained from the two modelling procedures validate the accuracy of both methods, which compares favourably with its precedent protocol CSMA/CD (with collision detection). A further extension of the protocol operation has been suggested to operate with multichannel systems. Two multichannel systems based on the CSMA/CA protocol for medium access are therefore proposed. These are; the dynamic multichannel system, which is based on two types of channel selection, the random choice (RC) and the idle choice (IC), and the sequential multichannel system. The latter has been proposed in order to supress the effect of the hidden terminal, which always represents a major problem with the usage of the contention random multiple access protocols with radio and mobile radio channels. Verification of their operation performance evaluation has been carried out using mathematical modelling for the dynamic system. However, simulation modelling has been chosen for the sequential system. Both systems are found to improve system operation and fault tolerance when compared to single channel operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As we settle into a new year, this second issue of Contact Lens and Anterior Eye allows us to reflect on how new research in this field impacts our understanding, but more importantly, how we use this evidence basis to enhance our day to day practice, to educate the next generation of students and to construct the research studies to deepen our knowledge still further. The end of 2014 saw the publication of the UK governments Research Exercise Framework (REF) which ranks Universities in terms of their outputs (which includes their paper, publications and research income), environment (infrastructure and staff support) and for the first time impact (defined as “any effect on, change or benefit to the economy, society, culture, public policy or services, health, the environment or quality of life, beyond academia” [8]). The REF is a process of expert review, carried out in 36 subject-based units of assessment, of which our field is typically submitted to the Allied Health, Dentistry, Nursing and Pharmacy panel. Universities that offer Optometry did very well with Cardiff, Manchester and Aston in the top 10% out of the 94 Universities that submitted to this panel (Grade point Average ranked order). While the format of the new exercise (probably in 2010) to allocate the more than £2 billion of UK government research funds is yet to be determined, it is already rumoured that impact will contribute an even larger proportion to the weighting. Hence it is even more important to reflect on the impact of our research. In this issue, Elisseef and colleagues [5] examine the intriguing potential of modifying a lens surface to allow it to bind to known wetting agents (in this case hyaluronic acid) to enhance water retention. Such a technique has the capacity to reduced friction between the lens surface and the eyelids/ocular surface, presumably leading to higher comfort and less reason for patients to discontinue with lens wear. Several papers in this issue report on the validity of new high precision, fast scanning imaging and quantification equipment, utilising techniques such as Scheimpflug, partial coherence interferometry, aberrometry and video allowing detailed assessment of anterior chamber biometry, corneal topography, corneal biomechanics, peripheral refraction, ocular aberrations and lens fit. The challenge is how to use this advanced instrumentation which is becoming increasingly available to create real impact. Many challenges in contact lenses and the anterior eye still prevail in 2015 such as: -While contact lens and refractive surgery complications are relatively rare, they are still too often devastating to the individual and their quality of life (such as the impact and prognosis of patients with Acanthmoeba Keratitis reported by Jhanji and colleagues in this issue [7]). How can we detect those patients who are going to be affected and what modifications do we need to make to contact lenses and patient management prevent this occurring? -Drop out from contact lenses still occurs at a rapid rate and symptoms of dry eye seem to be the leading cause driving this discontinuation of wear [1] and [2]. What design, coating, material and lubricant release mechanism will make a step change in end of day comfort in particular? -Presbyopia is a major challenge to hassle free quality vision and is one of the first signs of ageing noticed by many people. As an emmetrope approaching presbyopia, I have a vested interest in new medical devices that will give me high quality vision at all distances when my arms won’t stretch any further. Perhaps a new definition of presbyopia could be when you start to orientate your smartphone in the landscape direction to gain the small increase in print size needed to read! Effective accommodating intraocular lenses that truly mimic the pre-presbyopic crystalline lenses are still a way off [3] and hence simultaneous images achieved through contact lenses, intraocular lenses or refractive surgery still have a secure future. However, splitting light reaching the retina and requiring the brain to supress blurred images will always be a compromise on contrast sensitivity and is liable to cause dysphotopsia; so how will new designs account for differences in a patient's task demands and own optical aberrations to allow focused patient selection, optimising satisfaction? -Drug delivery from contact lenses offers much in terms of compliance and quality of life for patients with chronic ocular conditions such as glaucoma, dry eye and perhaps in the future, dry age-related macular degeneration; but scientific proof-of-concept publications (see EIShaer et al. [6]) have not yet led to commercial products. Part of this is presumably the regulatory complexity of combining a medical device (the contact lens) and a pharmaceutical agent. Will 2015 be the year when this innovation finally becomes a reality for patients, bringing them an enhanced quality of life through their eye care practitioners and allowing researchers to further validate the use of pharmaceutical contact lenses and propose enhancements as the technology matures? -Last, but no means least is the field of myopia control, the topic of the first day of the BCLA's Conference in Liverpool, June 6–9th 2015. The epidemic of myopia is a blight, particularly in Asia, with significant concerns over sight threatening pathology resulting from the elongated eye. This is a field where real impact is already being realised through new soft contact lens optics, orthokeratology and low dose pharmaceuticals [4], but we still need to be able to better predict which technique will work best for an individual and to develop new techniques to retard myopia progression in those who don’t respond to current treatments, without increasing their risk of complications or the treatment impacting their quality of life So what will your New Year's resolution be to make 2015 a year of real impact, whether by advancing science or applying the findings published in journals such as Contact Lens and Anterior Eye to make a real difference to your patients’ lives?

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydrogen is considered as an appealing alternative to fossil fuels in the pursuit of sustainable, secure and prosperous growth in the UK and abroad. However there exists a persisting bottleneck in the effective storage of hydrogen for mobile applications in order to facilitate a wide implementation of hydrogen fuel cells in the fossil fuel dependent transportation industry. To address this issue, new means of solid state chemical hydrogen storage are proposed in this thesis. This involves the coupling of LiH with three different organic amines: melamine, urea and dicyandiamide. In principle, thermodynamically favourable hydrogen release from these systems proceeds via the deprotonation of the protic N-H moieties by the hydridic metal hydride. Simultaneously hydrogen kinetics is expected to be enhanced over heavier hydrides by incorporating lithium ions in the proposed binary hydrogen storage systems. Whilst the concept has been successfully demonstrated by the results obtained in this work, it was observed that optimising the ball milling conditions is central in promoting hydrogen desorption in the proposed systems. The theoretical amount of 6.97 wt% by dry mass of hydrogen was released when heating a ball milled mixture of LiH and melamine (6:1 stoichiometry) to 320 °C. It was observed that ball milling introduces a disruption in the intermolecular hydrogen bonding network that exists in pristine melamine. This effect extends to a molecular level electron redistribution observed as a function of shifting IR bands. It was postulated that stable phases form during the first stages of dehydrogenation which contain the triazine skeleton. Dehydrogenation of this system yields a solid product Li2NCN, which has been rehydrogenated back to melamine via hydrolysis under weak acidic conditions. On the other hand, the LiH and urea system (4:1 stoichiometry) desorbed approximately 5.8 wt% of hydrogen, from the theoretical capacity of 8.78 wt% (dry mass), by 270 °C accompanied by undesirable ammonia and trace amount of water release. The thermal dehydrogenation proceeds via the formation of Li(HN(CO)NH2) at 104.5 °C; which then decomposes to LiOCN and unidentified phases containing C-N moieties by 230 °C. The final products are Li2NCN and Li2O (270 °C) with LiCN and Li2CO3 also detected under certain conditions. It was observed that ball milling can effectively supress ammonia formation. Furthermore results obtained from energetic ball milling experiments have indicated that the barrier to full dehydrogenation between LiH and urea is principally kinetic. Finally the dehydrogenation reaction between LiH and dicyandiamide system (4:1 stoichiometry) occurs through two distinct pathways dependent on the ball milling conditions. When ball milled at 450 RPM for 1 h, dehydrogenation proceeds alongside dicyandiamide condensation by 400 °C whilst at a slower milling speed of 400 RPM for 6h, decomposition occurs via a rapid gas desorption (H2 and NH3) at 85 °C accompanied by sample foaming. The reactant dicyandiamide can be generated by hydrolysis using the product Li2NCN.