980 resultados para Storage water heater
Resumo:
Nowadays there are several ways of supplying hot water for showers in residential buildings. One of them is the use of electric storage water heaters (boilers). This equipment raises the water temperature in a reservoir (tank) using the heat generated by an electric resistance. The behavior of this equipment in Brazil is still a research object and there is not a standard in the country to regulate its efficiency. In this context, an experimental program was conducted aiming to collect power consumption data to evaluate its performance. The boilers underwent an operation cycle to simulate a usage condition aiming to collect parameters for calculating the efficiency. This 1-day cycle was composed of the following phases: hot water withdrawal, reheating and standby heat loss. The methods allowed the identification of different parameters concerning the boilers work, such as: standby heat loss in 24 h, hot water withdrawal rate, reheating time and energy efficiency. The average energy efficiency obtained was of 75%. The lowest efficiency was of 62% for boiler 2 and the highest was of 85% for boiler 9. (C) 2008 Elsevier B.V. All rights reserved.
Käyttövesivaraajan ekosuunnitteluvaatimusten merkityksen arvioiminen rakennusten energianhallinnassa
Resumo:
Työn lähtökohtana ovat veden lämmittimiä koskeva ekosuunnittelulainsäädäntö ja sen vaatiman testausjärjestelmän laatiminen. Työn tavoitteena on arvioida ekosuunnittelulainsäädännön vaikutusta varaajan toimintaan osana rakennusten energianhallintaa. Työssä laaditaan käyttövesivaraajalle tuoteryhmäkohtaisen ekosuunnittelulainsäädännön mukainen mittausjärjestelmä energiatehokkuuden, lämpimän veden saannon, vuosittaisen sähkönkulutuksen sekä energiamerkinnän määrittämiseksi. Lisäksi tarkastellaan ekosuunnittelulainsäädännön tarkoituksenmukaisuutta, selvitetään varaajan toimintaperiaatteet sekä keinoja käyttöveden tarvitseman energian vähentämiseksi. Testattu käyttövesivaraaja täyttää ekosuunnitteluvaatimukset. Lämmitysenergian vähentäminen käyttövesivaraajan toimintaa tehostamalla on kuitenkin vaikeaa. Hybridijärjestelmien hyödyntäminen sähkölämmityksen ohella muita energianlähteitä ja esim. käyttöveden lämmöntalteenottoa käyttäen on toimivin keino vähentää käyttöveden energiankulutusta sekä parantaa varaajan energiatehokkuutta. Lämpimän käyttöveden energiankulutuksen osuus rakennuksen energiankulutuksesta kasvaa lainsäädännön pakottamana rakennusten kokonaisenergiankäytön vähentyessä. Ekosuunnittelulainsäädännön suora merkitys rakennusten energianhallintaan on Suomessa vähäistä nykyisen energiatehokkuustason ollessa suhteellisen korkea, jolloin käyttöveden tarvitseman energian vähentämiskeinoina on hyödynnettävä vaihtoehtoisia ratkaisuja.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Although there are many ways to cut you water heating bills, the all fall into two broad categories: reducing the amount of hot water you use and making your water heating system more efficient. Fortunately, there are several strategies that can help you consume less energy and save money - and still meet you hot water needs without sacrificing comfort or practicality. The booklet was designed to answer common questions about hot water systems and to provide you with the information necessary to make informed decision about a wide variety of topics, ranging from repairing hot water faucet leaks an insulation water supply pipes to installing low-flow shower heads and tuning you your existing water heather. You'll also find details on what to consider when it's time to go comparison shopping for a new water heater-including an evaluation of the alternatives to the common gas or electric storage tank unit that's found in the majority of homes in Iowa and across the country.
Resumo:
The increasing demand for water resources accentuates the need to reduce water waste through a more appropriate irrigation management. In the particular case of irrigated coffee planting, which in recent years presented growth with the predominance of drip irrigation, the improvement of drip irrigation management techniques is a necessity. The proper management of drip irrigation depends on the knowledge of the spatial pattern of soil moisture distribution inside the wetted strip formed under the irrigation lines. In this study, grids of 24 tensiometers were used to determine the water storage within the wetted strip formed under drippers, with a 3.78 L h-1 discharge, evenly spaced by 0.4 m, subjected to two different management criteria (fixed irrigation interval and 60 kPa tension). Estimates of storage based on a one-dimensional analysis, that only considers depth variations, were compared with two-dimensional estimates. The results indicate that for high-frequency irrigation the one-dimensional analysis is not appropriate. However, under less frequent irrigation, the two-dimensional analysis is dispensable, being the one-dimensional sufficient for calculating the water volume stored in the wetted strip.
Resumo:
Acknowledgements We would like to gratefully acknowledge the data provided by SEPA, Iain Malcolm. Mark Speed, Susan Waldron and many MSS staff helped with sample collection and lab analysis. We thank the European Research Council (project GA 335910 VEWA) for funding and are grateful for the constructive comments provided by three anonymous reviewers.
Resumo:
Whole macadamia kernels were immersed in water (specific gravity 1.00 g/cm(3)), brine (SG 1.02 g/cm(3)) and ethanol solution (SG 0.97 g/cm(3)) for 30 or 60 s, re-dried to 1.0-1.5% moisture (wet basis) and stored under vacuum for 0, 4 and 12 months. Immersion in water had no effect on the quality or shelf life of kernels, as measured by sensory evaluation and analysis of the kernel oil. Immersion in brine and ethanol solutions changed the flavour of kernels, but had no effect on shelf life or kernel oil stability over 12 months storage. Water flotation to separate kernels based on differences in oil content is therefore feasible, but microbiological concerns need to be investigated.
Resumo:
A set of bottled waters from a single natural spring distributed worldwide in polyethylene terephthalate (PET) bottles has been used to examine the effects of storage in plastic polymer material on the isotopic composition (delta(18)O and delta(2)H values) of the water. All samples analyzed were subjected to the same packaging procedure but experienced different conditions of temperature and humidity during storage. Water sorption and the diffusive transfer of water and water vapor through the wall of the PET bottle may cause isotopic exchange between water within the bottle and water vapor in air near the PET-water interface. Changes of about +4 parts per thousand for delta(2)H and +0.7 parts per thousand for delta(18)O have been measured for water after 253 days of storage within the PET bottle. The results of this study clearly indicate the need to use glass bottles for storing water samples for isotopic studies. It is imperative to transfer PET-bottled natural waters to glass bottles for their use as calibration material or potential international working standards. Copyright (C) 2008 John Wiley & Sons, Ltd.
Resumo:
An electric system based on renewable energy faces challenges concerning the storage and utilization of energy due to the intermittent and seasonal nature of renewable energy sources. Wind and solar photovoltaic power productions are variable and difficult to predict, and thus electricity storage will be needed in the case of basic power production. Hydrogen’s energetic potential lies in its ability and versatility to store chemical energy, to serve as an energy carrier and as feedstock for various industries. Hydrogen is also used e.g. in the production of biofuels. The amount of energy produced during hydrogen combustion is higher than any other fuel’s on a mass basis with a higher-heating-value of 39.4 kWh/kg. However, even though hydrogen is the most abundant element in the universe, on Earth most hydrogen exists in molecular forms such as water. Therefore, hydrogen must be produced and there are various methods to do so. Today, the majority hydrogen comes from fossil fuels, mainly from steam methane reforming, and only about 4 % of global hydrogen comes from water electrolysis. Combination of electrolytic production of hydrogen from water and supply of renewable energy is attracting more interest due to the sustainability and the increased flexibility of the resulting energy system. The preferred option for intermittent hydrogen storage is pressurization in tanks since at ambient conditions the volumetric energy density of hydrogen is low, and pressurized tanks are efficient and affordable when the cycling rate is high. Pressurized hydrogen enables energy storage in larger capacities compared to battery technologies and additionally the energy can be stored for longer periods of time, on a time scale of months. In this thesis, the thermodynamics and electrochemistry associated with water electrolysis are described. The main water electrolysis technologies are presented with state-of-the-art specifications. Finally, a Power-to-Hydrogen infrastructure design for Lappeenranta University of Technology is presented. Laboratory setup for water electrolysis is specified and factors affecting its commissioning in Finland are presented.
Resumo:
This master thesis presents a new technological combination of two environmentally friendly sources of energy in order to provide DHW, and space heating. Solar energy is used for space heating, and DHW production using PV modules which supply direct current directly to electrical heating elements inside a water storage tank. On the other hand a GSHP system as another source of renewable energy provides heat in the water storage tank of the system in order to provide DHW and space heating. These two sources of renewable energy have been combined in this case-study in order to obtain a more efficient system, which will reduce the amount of electricity consumed by the GSHP system.The key aim of this study is to make simulations, and calculations of the amount ofelectrical energy that can be expected to be produced by a certain amount of PV modules that are already assembled on a house in Vantaa, southern Finland. This energy is then intended to be used as a complement to produce hot water in the heating system of the house beside the original GSHP system. Thus the amount of electrical energy purchased from the grid should be reduced and the compressor in the GSHP would need fewer starts which would reduce the heating cost of the GSHP system for space heating and providing hot water.The produced energy by the PV arrays in three different circuits will be charged directly to three electrical heating elements in the water storage tank of the existing system to satisfy the demand of the heating elements. The excess energy can be used to heat the water in the water storage tank to some extent which leads to a reduction of electricity consumption by the different components of the GSHP system.To increase the efficiency of the existing hybrid system, optimization of different PV configurations have been accomplished, and the results are compared. Optimization of the arrays in southern and western walls shows a DC power increase of 298 kWh/year compared with the existing PV configurations. Comparing the results from the optimization of the arrays on the western roof if the intention is to feed AC power to the components of the GSHP system shows a yearly AC power production of 1,646 kWh.This is with the consideration of no overproduction by the PV modules during the summer months. This means the optimized PV systems will be able to cover a larger part of summer demand compared with the existing system.
Resumo:
The summer water balance of a typical Siberian polygonal tundra catchment is investigated in order to identify the spatial and temporal dynamics of its main hydrological processes. The results show that, besides precipitation and evapotranspiration, lateral flow considerably influences the site-specific hydrological conditions. The prominent microtopography of the polygonal tundra strongly controls lateral flow and storage behaviour of the investigated catchment. Intact rims of low-centred polygons build hydrological barriers, which release storage water later in summer than polygons with degraded rims and troughs above degraded ice wedges. The barrier function of rims is strongly controlled by soil thaw, which opens new subsurface flow paths and increases subsurface hydrological connectivity. Therefore, soil thaw dynamics determine the magnitude and timing of subsurface outflow and the redistribution of storage within the catchment. Hydraulic conductivities in the elevated polygonal rims sharply decrease with the transition from organic to mineral layers. This interface causes a rapid shallow subsurface drainage of rainwater towards the depressed polygon centres and troughs. The re-release of storage water from the centres through deeper and less conductive layers helps maintain a high water table in the surface drainage network of troughs throughout the summer.
Resumo:
Thermodynamic properties of bread dough (fusion enthalpy, apparent specific heat, initial freezing point and unfreezable water) were measured at temperatures from -40 degrees C to 35 degrees C using differential scanning calorimetry. The initial freezing point was also calculated based on the water activity of dough. The apparent specific heat varied as a function of temperature: specific heat in the freezing region varied from (1.7-23.1) J g(-1) degrees C(-1), and was constant at temperatures above freezing (2.7 J g(-1) degrees C(-1)). Unfreezable water content varied from (0.174-0.182) g/g of total product. Values of heat capacity as a function of temperature were correlated using thermodynamic models. A modification for low-moisture foodstuffs (such as bread dough) was successfully applied to the experimental data. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
O objectivo do presente trabalho foi caracterizar os condensados produzidos numa fábrica de pasta para papel para identificar e localizar pontos da sua contaminação. Para o efeito, foram recolhidas amostras de condensado e caracterizados os parâmetros condutividade, pH, sódio e sílica. A amostragem decorreu no período entre 15 de Setembro a 6 de Novembro de 2008. Através da análise dos resultados obtidos para as concentrações de sílica e de sódio de cada uma das correntes, foram identificadas como contaminadas as correntes de condensado provenientes do condensador do Turbogerador 4, da área dos Digestores Descontínuos, da Evaporação e do Aquecedor de Água Quente para o Branqueamento. A realização de um balanço pontual à sílica no tanque de condensados da Central permitiu concluir que a maior contribuição advém do condensador do Turbogerador 4. Na Evaporação ocorre contaminação do condensado quando as secções do Concentrador 1 são colocadas em serviço após lavagem. Durante o acompanhamento do arranque da Evaporação, uma das secções (1/B) registou um valor máximo na concentração de sódio no condensado de 135 mg/L Na. Do estudo resulta, enquanto não for reparado e/ou substituído o equipamento responsável pelas contaminações, a necessidade de admitir requisitos para controlo da qualidade da água da caldeira menos restritivos, nomeadamente para a razão sódio/fosfato. É necessário, contudo, o rigoroso acompanhamento da qualidade da água da caldeira (pH, sobretudo) para prevenir afastamentos inesperados dos limites de controlo. Durante a realização deste trabalho foram identificadas algumas situações a melhorar, tais como a uniformização dos valores de desvio para esgoto dos condensados e das unidades utilizadas, a adequação das escalas dos aparelhos de medida para as gamas de leitura de interesse, a verificação e calibração periódica do equipamento instalado em linha, a adopção do parâmetro “Sódio” para controlo da qualidade dos condensados, a instalação de sistemas de amostragem com arrefecimento em todas as correntes de condensados e a reparação ou substituição de algum equipamento instalado em linha que se encontra em muito mau estado e ainda a manutenção do equipamento mantendo-o em boas condições de limpeza.
Estudo de uma bomba de calor de expansão direta assistida por energia solar para a preparação de AQS
Resumo:
Este estudo consiste na caracterização da eficiência energética de uma bomba de calor de expansão direta que utiliza a energia solar como fonte térmica. De uma forma geral, teve-se a obrigação de procurar cada vez mais recursos renováveis e neste sentido a bomba de calor de expansão direta tem um papel importante no aquecimento de águas quentes sanitárias (AQS). Como ponto de partida, foi realizada uma descrição detalhada sobre todos os equipamentos da bomba de calor e elaborado um desenho técnico que identifica todos os componentes. No laboratório (casa inteligente) realizaram-se vários ensaios a fim de interpretar com rigor os resultados obtidos do desempenho da bomba de calor (COP) e do fator médio de desempenho sazonal (SPF). No início, realizaram-se ensaios para determinar as perdas estáticas do sistema termodinâmico, de seguida foram elaborados ensaios segundo a norma EN 16147 e por fim, ensaios de acordo com o perfil de utilização de AQS definido. No estudo experimental do COP, obteve-se uma elevada eficiência energética com um valor médio de 4,12. O COP aumenta para valores médios de 5 quando a temperatura de água no termoacumulador desce para 35ºC. Verificou-se que durante o período diurno o COP aumenta aproximadamente de 10% relativamente ao período noturno. A potência elétrica é mais elevada (450W) quando a água no termoacumulador está perto da temperatura desejável (55ºC), originando um esforço maior da bomba de calor. No estudo experimental do SPF, verificou-se que nos ensaios segundo a norma EN16147 os valores obtidos variaram entre 1,39 e 1,50 (Classe “B”). No estudo realizado de acordo com o perfil de utilização de AQS definido pelo utilizador, o SPF é superior em 12% relativamente ao obtido segundo os ensaios realizados de acordo a norma EN16147. Verificou-se que o aumento da temperatura do ar exterior implica um aumento do SPF (cerca de 2% a 5%), enquanto a energia solar não influência nos resultados.