999 resultados para State of Charge


Relevância:

100.00% 100.00%

Publicador:

Resumo:

For a microgrid with a high penetration level of renewable energy, energy storage use becomes more integral to the system performance due to the stochastic nature of most renewable energy sources. This thesis examines the use of droop control of an energy storage source in dc microgrids in order to optimize a global cost function. The approach involves using a multidimensional surface to determine the optimal droop parameters based on load and state of charge. The optimal surface is determined using knowledge of the system architecture and can be implemented with fully decentralized source controllers. The optimal surface control of the system is presented. Derivations of a cost function along with the implementation of the optimal control are included. Results were verified using a hardware-in-the-loop system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Li-ion batteries have been widely used in electric vehicles, and battery internal state estimation plays an important role in the battery management system. However, it is technically challenging, in particular, for the estimation of the battery internal temperature and state-ofcharge (SOC), which are two key state variables affecting the battery performance. In this paper, a novel method is proposed for realtime simultaneous estimation of these two internal states, thus leading to a significantly improved battery model for realtime SOC estimation. To achieve this, a simplified battery thermoelectric model is firstly built, which couples a thermal submodel and an electrical submodel. The interactions between the battery thermal and electrical behaviours are captured, thus offering a comprehensive description of the battery thermal and electrical behaviour. To achieve more accurate internal state estimations, the model is trained by the simulation error minimization method, and model parameters are optimized by a hybrid optimization method combining a meta-heuristic algorithm and the least square approach. Further, timevarying model parameters under different heat dissipation conditions are considered, and a joint extended Kalman filter is used to simultaneously estimate both the battery internal states and time-varying model parameters in realtime. Experimental results based on the testing data of LiFePO4 batteries confirm the efficacy of the proposed method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis presents a load sharing method applied in a distributed micro grid system. The goal of this method is to balance the state-of-charge (SoC) of each parallel connected battery and make it possible to detect the average SoC of the system by measuring bus voltage for all connected modules. In this method the reference voltage for each battery converter is adjusted by adding a proportional SoC factor. Under such setting the battery with a higher SoC will output more power, whereas the one with lower SoC gives out less. Therefore the higher SoC battery will use its energy faster than the lower ones, and eventually the SoC and output power of each battery will converge. And because the reference voltage is related to SoC status, the information of the average SoC in this system could be shared for all modules by measuring bus voltage. The SoC balancing speed is related to the SoC droop factors. This SoC-based load sharing control system is analyzed in feasibility and stability. Simulations in MATLAB/Simulink are presented, which indicate that this control scheme could balance the battery SoCs as predicted. The observation of SoC sharing through bus voltage was validated in both software simulation and hardware experiments. It could be of use to non-communicated distributed power system in load shedding and power planning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lithium Ion (Li-Ion) batteries have got attention in recent decades because of their undisputable advantages over other types of batteries. They are used in so many our devices which we need in our daily life such as cell phones, lap top computers, cameras, and so many electronic devices. They also are being used in smart grids technology, stand-alone wind and solar systems, Hybrid Electric Vehicles (HEV), and Plug in Hybrid Electric Vehicles (PHEV). Despite the rapid increase in the use of Lit-ion batteries, the existence of limited battery models also inadequate and very complex models developed by chemists is the lack of useful models a significant matter. A battery management system (BMS) aims to optimize the use of the battery, making the whole system more reliable, durable and cost effective. Perhaps the most important function of the BMS is to provide an estimate of the State of Charge (SOC). SOC is the ratio of available ampere-hour (Ah) in the battery to the total Ah of a fully charged battery. The Open Circuit Voltage (OCV) of a fully relaxed battery has an approximate one-to-one relationship with the SOC. Therefore, if this voltage is known, the SOC can be found. However, the relaxed OCV can only be measured when the battery is relaxed and the internal battery chemistry has reached equilibrium. This thesis focuses on Li-ion battery cell modelling and SOC estimation. In particular, the thesis, introduces a simple but comprehensive model for the battery and a novel on-line, accurate and fast SOC estimation algorithm for the primary purpose of use in electric and hybrid-electric vehicles, and microgrid systems. The thesis aims to (i) form a baseline characterization for dynamic modeling; (ii) provide a tool for use in state-of-charge estimation. The proposed modelling and SOC estimation schemes are validated through comprehensive simulation and experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il presente lavoro propone la stesura di un codice in ambiente MATLAB per l'analisi energetica di powertrain ibridi operanti nel ciclo WLTP con il particolare funzionamento del motore termico benzina a punto fisso stechiometrico. Nello specifico, il codice prende dei dati in input tramite un'interfaccia grafica ed avvia una simulazione, i cui risultati principali corrispondono ad emissioni di anidride carbonica per chilometro percorso ed ai chilometri percorsi con un litro di carburante. Queste sono le due grandezze che questo lavoro si prefigge di ottimizzare, dalle quali proviene la scelta del particolare funzionamento del motore termico. Sono state implementate due differenti strategie di controllo, una generale ed una più particolare. La simulazione con la strategia generale è stata applicata a tre differenti scenari reali, con le caratteristiche tecniche di tre veicoli realmente esistenti che vengono inserite nell'interfaccia grafica. I risultati provenienti da queste simulazioni sono stati poi analizzati e discussi nel dettaglio, anche con l'ausilio di grafici a supporto della spiegazione. La strategia di controllo particolare non è stata applicata a scenari reali ma ha portato alla definizione di una ipotetica architettura di powertrain ibrido, alla quale la sopracitata strategia si adatta al meglio. Dopo aver proposto miglioramenti e possibili ulteriori sviluppi di questo lavoro, sono state tratte le conclusioni generali, allargando il tutto al contesto più ampio in cui si va ad inserire.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The alternative low-spin states of Fe3+ and Fe2+ cytochrome c induced by SDS or AOT/hexane reverse micelles exhibited the heme group in a less rhombic symmetry and were characterized by electron paramagnetic resonance, UV-visible, CD, magnetic CD, fluorescence, and Raman resonance. Consistent with the replacement of Met 80 by another strong field ligand at the sixth heme iron coordination position, Fe3+ ALSScytc exhibited 1-nm Soret band blue shift and e enhancement accompanied by disappearance of the 695-nm charge transfer band. The Raman resonance, CD, and magnetic CD spectra of Fe3+ and Fe2+ ALSScytc exhibited significant changes suggestive of alterations in the heme iron microenvironment and conformation and should not be assigned to unfold because the Trp(59) fluorescence remained quenched by the neighboring heme group. ALSScytc was obtained with His(33) and His(26) carboxyethoxylated horse cytochrome c and with tuna cytochrome c (His(33) replaced by Asn) pointing out Lys(79) as the probable heme iron ligand. Fe3+ ALSScytc retained the capacity to cleave tert-butylhydroperoxide and to be reduced by dithiothreitol and diphenylacetaldehyde but not by ascorbate. Compatible with a more open heme crevice, ALSScytc exhibited a redox potential similar to 200 mV lower than the wild-type protein (1220 mV) and was more susceptible to the attack of free radicals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The relation between the properties of polyampholytes in aqueous solution and their adsorption behaviors on silica and cellulose surfaces was investigated. Four polyampholytes carrying different charge densities but with the same nominal ratio of positive to negative segments and two structurally similar polyelectrolytes (a polyacid and a polybase) were investigated by using quartz crystal microgravimetry using silica-coated and cellulose-coated quartz resonators. Time-resolved mass and rigidity (or viscoelasticity) of the adsorbed layer was determined from the shifts in frequency (Delta f) and energy dissipation (Delta D) of the respective resonator. Therefore, elucidation of the dynamics and extent of adsorption, as well as the conformational changes of the adsorbed macromolecules, were possible. The charge properties of the solid Surface played a crucial role in the adsorption of the studied polyampholytes, which was explained by the capability of the surface to polarize the polyampholyte at the interface. Under the same experimental conditions, the polyampholytes had a higher nominal charge density phase-separated near the interface, producing a soft, dissipative, and loosely bound layer. In the case of cellulose substrates, where adsorption was limited, electrostatic and polarization effects were concluded to be less significant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Journal of Cleaner Production, nº 17, p. 36-52

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Health Minister Edwin Poots today marked the roll-out of a ground-breaking hi-tech scheme which will enable more patients to monitor their health in their own homes. Following funding of £18m from the Department of Health, the newly named Centre for Connected Health and Social Care (CCHSC), part of the Public Health Agency, worked in partnership with business consortium TF3to establish the innovative Telemonitoring NI service. The service is now being delivered by the TF3 consortium in partnership with the Health and Social Care Trusts.Remote telemonitoring combines technology and services that enable patients with chronic diseases to test their vital signs such as pulse, blood pressure, body weight, temperature, blood glucose and oxygen levels at home on a daily basis. The service will now be rolled out to 3,500 patients across Northern Ireland per annum for a period of six years.Mr Poots today visited the home of Larne pensioner Michael Howard who has Chronic Pulmonary Obstructive Disorder (COPD) to hear how Telemonitoring NI has changed his life.During the visit Mr Poots said: "Chronic diseases such as heart disease, diabetes and COPD affect around three quarters of people over the age of 75. This is the generation from whom transport and mobility pose the biggest problems. The Telemonitoring NI service will allow thousands to monitor their vital signs without having to leave their own homes."It means that patients are able to understand and manage their condition better. Many say it has improved their confidence and given them peace of mind. With a health professional monitoring each patient's health on a daily basis, there is less need for hospital admission. Carers are also better informed with the pro-active support provided. It means earlier intervention in, and the prevention of, deterioration of condition, acute illness and hospital admissions."Telemonitoring NI is an excellent example of how the Health Service can innovateusing modern technology to deliver a better service for our patients."Eddie Ritson, Programme Director of CCHSC, PHA, said: "The roll-out of Telemonitoring NI represents a significant step towards providing quality care for the growing number of people with heart disease, stroke, some respiratory conditions and diabetes who want to live at home while having their conditions safely managed."This new service will give people more information which combined with timely advice will enable patients to gain more control over their health while supporting them to live independently in their own homes for longer."A patient will take their vital sign measurements at home, usually on a daily basis. and these will automatically be transmited to the Tf3 system. The resulting readings are monitored centrally by a healthcare professional working in the Tf3 triage team. If the patient's readings show signs of deterioration to an unacceptable level, they will be contacted by phone by a nurse working in a central team and if appropriate a healthcare professional in the patient's local Trust will be alerted to enable them to take appropriate action."Families and carers will also benefit from the reassurance that chronic health conditions are being closely monitored on an ongoing basis. The information collected through the service can also be used by doctors, nurses and patients in making decisions on how individual cases should be managed. "Using the service, Mr Howard, 71, who has emphysema - a long-term, progressive disease of the lungs that primarily causes shortness of breath - monitors his vital signs using the new technology every weekday morning. The information is monitored centrally and if readings show signs of deterioration to an unacceptable level, Mr Howard's local healthcare professional is alerted."Taking my readings is such a simple process but one that gives me huge benefits as it is an early warning system to me and also for the specialist nurses in charge of my care. Without the remote telemonitoring I would be running back and forward to the GPs' surgery all the time to have things checked out," he explained."Having my signs monitored by a nurse means any changes in my condition are dealt with immediately and this has prevented me from being admitted to hospital - in the past I've had to spend six days in hospital any time I'm admitted with a chest infection."The telemonitoring is not only reassuring for me, it also gives me more control over managing my own condition and as a result I have less upheaval in my life, and I'm less of a cost to the health care system. Most importantly, it gives me peace of mind and one less thing to worry about at my age."Patients seeking further information about the new telemonitoring service should contact their healthcare professional.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Report for the scientific sojourn carried out at the Paul Drude Institut für Festkörperelektronik of the Stanford University, USA, from 2010 to 2012. The objective of this project is the transport and control of electronic charge and spin along GaAs-based semiconductor heterostructures. The electronic transport has been achieved by taking advantage of the piezolectric field induced by surface acoustic waves in non-centrosymmetric materials like GaAs. This piezolectric field separates photogenerated electrons and holes at different positions along the acoustic wave, where they acummulate and are transported at the same velocity as the wave. Two different kinds of structures have been studied: quantum wells grown along the (110) direction, both intrinsic and n-doped, as well as GaAs nanowires. The analysis of the charge acoustic transport was performed by micro-photoluminescence, whereas the detection of the spin transport was done either by analyzing the polarization state of the emitted photoluminescence or by Kerr reflectometry. Our results in GaAs quantum wells show that charge and spin transport is clearly observed at the non-doped structures,obtaining spin lifetimes of the order of several nanoseconds, whereas no acoutically induced spin transport was detected for the n-doped quantum wells. In the GaAs nanowires, we were able of transporting successfully both electrons and holes along the nanowire axis, but no conservation of the spin polarization has been observed until now. The photoluminescence emitted by these structures after acoustic transport, however, shows anti-bunching characteristics, making this system a very good candidate for its use as single photon emitters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sensitized photolysis of [Ru(NH3)(6)](2+) by the organic dye rhodamine B and biacetyl was studied under conditions in which only the sensitizer absorbs. The reaction products resulting from ammonia aquation and Ru(II) to Ru(III) oxidation are the same for direct and sensitized photolysis. The energy transfer rate constant, calculated from the fluorescence quenching of rhodamine B, is similar to that estimated from the limiting quantum yield of the photosensitized photoaquation of the complex. Both reactions originate from a common reactive low-lying ligand-field (LF) state, which is also responsible for the direct photolysis reactions. This state, which leads directly to photoaquation, seems to have a certain charge transfer to solvent (CTTS) character, which is responsible for the photo-oxidation products. Sensitization is effective with rhodamine B (17 450 cm(-1)) and biacetyl (19 000 cm(-1)), whereas no reaction is observed with neutral red (16 900 cm(-1)). These results show that the excited state responsible for the photochemical reactions lies in the energy range between 16 900 cm(-1) and 17 700 cm(-1) and possesses spin-orbit character.