28 resultados para Stapler
Resumo:
Our objective was to assess the applicability of hysterectomy by the vaginal route completely performed with Autosuture staples. Between January 1992 and September 1993, 5 vaginal hysterectomies using Autosuture staplers were performed by the authors. Five vaginal hysterectomies matched for age, parity, and uterine size performed by the same surgeons using reabsorbable sutures during the same period were used as case controls. No febrile morbidity, cuff infections, thrombophlebitis, bladder injury, or hemorrhage complications were observed in the 10 women who entered the study. In summary, vaginal hysterectomy can be performed with Autosutures easily, probably faster with experience, and with less oozing from the operative field, thus providing a safe procedure.
Resumo:
Closure of loop ileostomy can be safely performed using sutures or staplers. The aim of the present study was to compare the cost effectiveness of three different techniques.
Resumo:
OBJECTIVE: To describe the use of an endobronchial blocker (EBB) and to perform selective ventilation during pulmonary lobe resection via thoracotomy in a dog and report its accidental stapling in the resection site. STUDY DESIGN: Clinical case report. ANIMAL: One female dog with a suspected abscess or neoplasia of the right caudal pulmonary lobe. METHODS: One-lung ventilation was performed using a wire-guided EBB to seal the contaminated parenchyma and facilitate surgical access. The affected lung parenchyma was resected and the resection site was closed with staples. RESULTS: Lobar resection was performed successfully, but the loop of the EBB guide wire was inadvertently entrapped in the staple line of the lobectomy. Staples were removed to release the wire loop, and the resulting air leak caused loss of ventilation control until the parenchyma was re-sealed. CONCLUSIONS: We recommend removing the wire guide associate with the EBB after successful lung separation to avoid accidents that could have life-threatening consequences if not recognized. CLINICAL RELEVANCE: One-lung ventilation is useful to isolate healthy parenchyma from diseased parenchyma during lobectomy. Anesthesiologists and surgeons need to be aware of the potential complications associated with use of EBB.
Resumo:
Background: Minimally invasive techniques have been revolutionary and provide clinical evidence of decreased morbidity and comparable efficacy to traditional open surgery. Computer-assisted surgical devices have recently been approved for general surgical use. Aim: The aim of this study was to report the first known case of pancreatic resection with the use of a computer-assisted, or robotic, surgical device in Latin America. Patient and Methods: A 37-year-old female with a previous history of radical mastectomy for bilateral breast cancer due to a BRCA2 mutation presented with an acute pancreatitis episode. Radiologic investigation disclosed an intraductal pancreatic neoplasm located in the neck of the pancreas with atrophy of the body and tail. The main pancreatic duct was enlarged. The surgical decision was to perform a laparoscopic subtotal pancreatectomy, using the da Vinci (R) robotic system (Intuitive Surgical, Sunnyvale, CA). Five trocars were used. Pancreatic transection was achieved with vascular endoscopic stapler. The surgical specimen was removed without an additional incision. Results: Operative time was 240 minutes. Blood loss was minimal, and the patient did not receive a transfusion. The recovery was uneventful, and the patient was discharged on postoperative day 4. Conclusions: The subtotal laparoscopic pancreatic resection can safely be performed. The da Vinci robotic system allowed for technical refinements of laparoscopic pancreatic resection. Robotic assistance improved the dissection and control of major blood vessels due to three-dimensional visualization of the operative field and instruments with wrist-type end-effectors.
Resumo:
Background and Purpose: The right kidney has been less frequently used in live donor nephrectomy, because of the shorter length of the right renal vein (RRV) that is associated with technical difficulties and higher rates of venous thrombosis. In live open donor or deceased donor transplant nephrectomy, an additional cuff of the inferior vena cava is usually removed, but this is a more difficult and risky maneuver in laparoscopic nephrectomy. For this reason, laparoscopic right nephrectomy (LRN) for renal transplantation (RT) is not frequently performed in most medical institutions. We evaluate the difference between RRV and left renal vein (LRV) lengths in cadavers, as harvested for RT by three clamping methods. Our objective was to obtain information that could clarify when LRN for RT should be encouraged or avoided with regard to conventional surgery. Materials and Methods: Ninety adult fresh unfrozen cadavers were randomly divided into three groups of 30, according to the clamping device used: Satinsky, stapler, and Hem-o-lok clip. The abdominal viscera were removed through a median xyphopubic incision, and the veins were measured on the bench. Two lateral limits were used: The renal hilum and the tangential line of the renal poles. As for medial limits, the inferior vena cava or the laparoscopic clipping device on the RRV were used on the right side, while on the LRV, the medial border of the emergence of the adrenal vein was considered. After section of the renal vein, a slight traction of the extremity was applied for the measurement. All measurements were obtained three times using a metallic millimetric ruler, and the arithmetic mean was considered. The chi-square, one-way analysis of variance, and paired t tests were used for statistical analysis. Statistical significance was accepted at P <= 0.05. Results: The groups of cadavers were homogeneous in demographic characteristics. Regardless of the clamping method and considering the useful length of the LRV, the RRV was statistically smaller. The evaluation of the vein length did not depend on the lateral limit considered. Independent of the clamping method, on both sides, the lengths after the vein section were larger than before the section, a fact attributed to traction. Use of a stapler and a single Hem-o-lok presented the same waste of vein length on the right side. On average, the RRV was 13.7% shorter than the LRV. Conclusions: With the wide acceptance of laparoscopic live donor nephrectomy, the length difference between the veins of both kidneys is an important issue, and the right kidney is therefore used less than the left, compared with conventional surgery. This article represents the first step to quantify the anatomic length of renal veins in different situations. Certainly, more imagenologic or surgical studies should be carried out before decisions can be made for better selection of patients for LRN.
Resumo:
Background: Recent advances in laparoscopic devices and experience with advanced techniques have increased the indications for laparoscopic liver. Aim: The aim of this work was to present a video with technical aspects of a pure laparoscopic left hemi-hepatectomy (segments 2, 3, and 4) by using the intrahepatic Glissonian approach and control of venous outflow without hilar dissection or the Pringle maneuver. Patient and Method: A 63-year-old woman with a 5-cm solitary liver metastasis was referred for treatment. Four trocars were used. The left lobe was pulled upward and the lesser omentum was divided, exposing Arantius' ligament. This ligament is a useful landmark for the identification of the main left Glissonian pedicle. A small anterior incision was made in front of the hilum, and a large clamp was introduced behind the Arantius' ligament toward the anterior incision, allowing control of the left main sheath. Ischemic discoloration of the left liver was achieved and marked with cautery. The vascular clamp was replaced by a stapler. If ischemic delineation was coincident with a previously marked area, the stapler was fired. The left hepatic vein was dissected and encircled. Parenchymal transection and vascular control of the hepatic veins were accomplished with a Harmonic scalpel and an endoscopic stapling device, as appropriate. All these steps were performed without the Pringle maneuver and without hand assistance. Results: Operative time was 220 minutes with minimum blood loss. Hospital stay was 4 days. Pathology showed free surgical margins. The patient is alive with no signs of recurrence 18 months after the operation. Conclusion: Totally laparoscopic left hemihepatectomy is safe and feasible in selected patients and should be considered for patients with benign or malignant liver neoplasms. The described technique, with the use of the intrahepatic Glissonian approach and control of venous outflow, may facilitate laparoscopic left hemihepatectomy by reducing the technical difficulties in pedicle control and may decrease bleeding during liver transection.
Resumo:
Bisegmentectomy 7-8 is feasible even in the absence of a large inferior right hepatic vein. To our knowledge, this operation has never been performed by laparoscopy. This study was designed to present video of pure laparoscopic bisegmentectomy 7-8 and bisegmentectomy 2-3 in one-stage operation for bilateral liver metastasis. A 67-year-old man with metachronous bilobar colorectal liver metastasis was referred for surgical treatment after neoadjuvant chemotherapy. CT scan disclosed two liver metastases: one located between segments 7 and 8 and another one in segment 2. At liver examination, another metastasis was found on segment 3. We decided to perform a bisegmentectomy 7-8 along with bisegmentectomy 2-3 in a single procedure. The operation began with mobilization of the right liver with complete dissection of retrohepatic vena cava. Inferior right hepatic vein was absent. Right hepatic vein was dissected and encircled. Upper part of right liver, containing segment 7 and 8, was marked with cautery. Selective hemi-Pringle maneuver was performed and right hepatic vein was divided with stapler. At this point, liver rotation to the left allowed direct view and access to the superior aspect of the right liver. Liver transection was accomplished with harmonic scalpel and endoscopic stapling device. Bisegmentectomy 2-3 was performed using the intrahepatic Glissonian approach. The specimens were extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 240 minutes with no need for transfusion. Recovery was uneventful. Patient was discharged on the fifth postoperative day. Patient is well with no evidence of disease 14 months after liver resection. Tumor markers are within normal range. Bisegmentectomy 7-8 may increase resectability rate in patients with bilateral lesions. This operation can be performed safely by laparoscopy. Preservation of segments 5 and 6 permitted simultaneous resection of segments 2 and 3 with adequate liver remnant.
Resumo:
Experience with advanced techniques has increased the indications for laparoscopic liver resection. This video demonstrates technical aspects of a pure laparoscopic mesohepatectomy using intrahepatic Glissonian technique. To the best of our knowledge, this is the first case of anatomic laparoscopic mesohepatectomy using the Glissonian approach published in the English literature. A 62-year-old man with colorectal liver metastasis occupying central liver segments was referred for surgical treatment. The first step is the control of segment 4 pedicle. Using the round ligament as a guide, one incision is performed on its right margin and another is made at the bottom of segment 4. A vascular clamp is introduced through those incisions to occlude segment 4 Glissonian sheath. The next step is to control the right anterior pedicle. The first incision is made in front of the hilum and another is performed on the right edge of gallbladder bed. Laparoscopic clamp is introduced through these incisions and closed producing ischemic discoloration of segments 5 and 8. Vascular clamp is replaced by an endoscopic vascular stapling device and stapler is fired. Line of liver transection is marked along the liver surface following ischemic area. Liver transection is accomplished with bipolar vessel sealing device and endoscopic stapling device as appropriate. Specimen was extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 200 min with minimum blood loss and no need for blood transfusion. Recovery was uneventful, and the patient was discharged on the fifth postoperative day. Histological examination revealed clear surgical margins. Mesohepatectomy can be safely performed laparoscopically in selected patients and by surgeons with expertise in both liver surgery and laparoscopic techniques. The use of the intrahepatic Glissonian approach may help to identify the exact limits of the mesohepatectomy to avoid ischemic injury of the remnant liver.
Resumo:
Aim Stapled haemorrhoidopexy may damage the anorectal musculature and its sensorimotor function. Most studies have not used a barostat for the measurement of compliance. This study aimed to investigate the effect of stapled haemorrhoidopexy on rectal compliance and sensitivity. Method After Ethical Committee approval, we studied 10 male patients (mean age 33.8 years) with third- or fourth-degree haemorrhoids. Rectal compliance and sensitivity were measured with a 600-ml bag and an electronic barostat. Volunteers were submitted to two consecutive rectal distension protocols, including continuous distension at 2, 4 and 6 months after stapled haemorrhoidopexy. Intraluminal volume and pressure were recorded, including the first rectal sensation, desire to defecate and onset of rectal pain. Another group of 10 male control patients (mean age 24.9 years) with pilonidal sinus and no haemorrhoids was also included in the study. Results Two months after stapled haemorrhoidopexy, rectal compliance decreased (7.1 +/- 0.2 vs 5.3 +/- 0.1, 6.4 +/- 0.1 vs 5.1 +/- 0.1 and 5.6 +/- 0.2 vs 4.7 +/- 0.1 ml/mmHg for first rectal sensation, desire to defecate and rectal pain, respectively; P < 0.05). The sensitivity threshold volume did not change for the first sensation but decreased significantly for the desier to defecate and pain (p < 0.05) (116.8 +/- 13.8 vs 148.4 +/- 14.61, 251.1 +/- 8.9 vs 185.8 +/- 8.6 and 293.3 +/- 16.6 vs 221.2 +/- 6.0 ml for first rectal sensation, desire to defecate and rectal pain, respectively). Four and 6 months after surgery, rectal compliance and sensitivity returned to levels similar to those in the basal period. Muscle tissue was found in only three of the 10 resected doughnuts. Controls remained without any change in rectal compliance and sensitivity. Conclusion Stapled haemorrhoidopexy transiently decreases rectal compliance and sensitivity threshold in young male patients.
Resumo:
BACKGROUND AND OBJECTIVE: Standardization of surgical technique helps to reproduce excellent clinical outcomes, especially in teaching institutions. We aim to describe in detail our established approach for oncological right colectomy. TECHNIQUE: The right colon is mobilized in a five-step latero-inferior approach starting off with (1) the terminal ileum, visualizing the duodenum and the head of pancreas. (2) The ascending colon is dissected from the retroperitoneum, and takedown of the hepatic flexure is completed coming retrograde from the transverse colon (3). (4) Transection of the remaining retroperitoneal attachments completes exposure of the duodenum and mobilization of the right colon. (5) Ileocolic vessels are dissected out and divided close to their origin, and the mesocolon is divided. We then establish intestinal continuity by use of a side-to-side stapled technique. (1) The arms of a linear cutting stapler are inserted via transverse incisions at the anti-mesenteric sides of the terminal ileum and the transverse colon (tenia) and fired. (2) The enterotomy site is closed by removal of the specimen using a second transverse firing of the linear cutting stapler. An important final step is the (3) reinforcement of the anastomotic ends and the crossing of the staple lines; an omental patch and closure of the mesenteric window are optional. CONCLUSION: The suggested standardized five-step lateral-to-medial dissection of the right colon and the three-step side-to-side stapled technique for ileo-colonic anastomosis are easy to learn and to reproduce. Careful adherence to pivotal technical details will help to obtain an optimal oncological outcome and a consistently low leak rate around 2 %.
Resumo:
Roux-en-Y gastric bypass (RYGBP) is one of the most commonly performed bariatric procedures for morbidly obese patients. It is associated with effective long-term weight loss, but can lead to significant complications, especially at the gastrojejunostomy (GJS). All the patients undergoing laparoscopic RYGBP at one of our two institutions were included in this study. The prospectively collected data were reviewed retrospectively for the purpose of this study, in which we compared two different techniques for the construction of the GJS and their effects on the incidence of complications. In group A, anastomosis was performed on the posterior aspect of the gastric pouch. In group B, it was performed across the staple line used to form the gastric pouch. A 21-mm circular stapler was used in all patients. A total of 1,128 patients were included between June 1999 and September 2009-639 in group A and 488 in group B. Sixty patients developed a total of 65 complications at the GJS, with 14 (1.2%) leaks, 42 (3.7%) strictures, and 9 (0.8%) marginal ulcers. Leaks (0.2% versus 2%, p = 0.005) and strictures (0.8% versus 5.9%, p < 0.0001) were significantly fewer in group B than in group A. Improved surgical technique, as we propose, with the GJS across the staple line used to form the gastric pouch, significantly reduces the rate of anastomotic complications at the GJS. A circular 21-mm stapler can be used with a low complication rate, and especially a low stricture rate. Additional methods to limit complications at the GJS are probably not routinely warranted.