845 resultados para Standard Fire
Resumo:
"Table of cases": p. 281-308.
Resumo:
Wood is a natural and traditional building material, as popular today as ever, and presents advantages. Physically, wood is strong and stiff, but compared with other materials like steel is light and flexible. Wood material can absorb sound very effectively and it is a relatively good heat insulator. But dry wood burns quite easily and produces a great deal of heat energy. The main disadvantage is the high level of combustion when exposed to fire, where the point at which it catches fire is from 200–400°C. After fire exposure, is need to determine if the charred wooden structures are safe for future use. Design methods require the use of computer modelling to predict the fire exposure and the capacity of structures to resist those action. Also, large or small scale experimental tests are necessary to calibrate and verify the numerical models. The thermal model is essential for wood structures exposed to fire, because predicts the charring rate as a function of fire exposure. The charring rate calculation of most structural wood elements allows simple calculations, but is more complicated for situations where the fire exposure is non-standard and in wood elements protected with other materials. In this work, the authors present different case studies using numerical models, that will help professionals analysing woods elements and the type of information needed to decide whether the charred structures are adequate or not to use. Different thermal models representing wooden cellular slabs, used in building construction for ceiling or flooring compartments, will be analysed and submitted to different fire scenarios (with the standard fire curve exposure). The same numerical models, considering insulation material inside the wooden cellular slabs, will be tested to compare and determine the fire time resistance and the charring rate calculation.
Resumo:
This paper present a study on the behaviour of tabique walls, concerning its fire resistance. This work is based on the experimental analysis of real scale tabique panels. Such walls were made in pine wood with an earth-based mortar finishing. In order to assess the earth-based mortar thickness effect on the fire resistance of the wall, three specimens were tested with three different mortar thicknesses of 15 mm, 10 mm and 5 mm. The earth-based mortar was previously analysed in the laboratory. The wooden structures were constructed based on traditional tabique technique. The experimental models were tested in a fire-resistance furnace, according to the ISO 834 standard fire. Temperatures were recorded using two data acquisition systems (spot measuring and field measuring). Fire resistance of test elements is expressed as the time during which the appropriate criteria have been satisfied so that one can predict the time before collapse, increasing both people and property safety. The obtained results are of great importance as they allow to improve the knowledge on tabique walls behaviour subjected to fire conditions. Two performance criteria were verified: the integrity criteria and the insulation criteria.
Resumo:
Työn tavoitteena oli kehittää teräspalkkirakenteiden palosuunnittelua ja palosuojauksen toteutusta öljynjalostamolla käytettävien kantavien teräspalkkirakenteiden osalta. Lisäksi tavoitteena oli luoda suunnitteluohjeen runko palomitoituksen toteuttamiseksi Neste Engineering Oy:ssä. Ongelmakohtia työssä olivat rakenteiden kapasiteettien tarkka määritys, toimivien toteutusratkaisujen etsiminen, sekä öljynjalostamolla mitoituspalona käytettävän hiilivetypalon SFS-ENV-1992-1-2 käyttö yleisemmin mitoituspalona käytettävän standardipalo ISO-834 sijaan. Työssä perehdyttiin kirjallisuuden perusteella eri palosuojausmenetelmiin. Tarkemman jatkotutkimuksen kohteeksi otettiin jo käytössä hyväksi havaittu teräsputkipalkkien sisäpuoleinen betonitäyttö. Menetelmässä teräsputkipalkin oletetaan kantavan kuormat normaalitilassa ja sisällä olevan raudoitetun betonin palossa. Palkkirakenteiden kapasiteettimitoitus määritettiin laskennallisesti poikkileikkauksille. Mitoitus perustuu palkissa tapahtuvien sisäisten venymien ja puristumien tarkasteluun, sekä poikkileikkauksen tarkan lämpötilajakauman huomioimiseen. Raudoitustankojen ankkurointia palkki-pilari-liitoksessa kehitettiin valmistuksen kannalta yksioikoisemmaksi ja helpommin toteutettavaksi. Palkkien raudoituksiin suunniteltiin kierremuhvijatkoksella toteutettava ankkurointimenetelmä, jolla palkkien raudoitustangot saadaan ankkuroitua täydestä kapasiteetistaan tapauskohtaisesti pilarin vastakkaisella puolella olevaan palkkiin tai ankkurointikappaleella pilariin. Teräsputkipilarin betonivalun vaihtoehtoisiin menetelmiin tutustuttiin. Pilarin alapäähän asennettavan venttiilin läpi tapahtuva täyttö helpottaa betonointityövaihetta. Tutkimuksen tuloksena luotiin suunnitteluohjeen runko, jonka pohjalta voidaan tehdä lopullinen ohje. Myös työn tuloksena saatu laskentaohjelma palkkien momentti-kapasiteetin ja pilarin nurjahduskuorman laskemiseksi helpottaa suunnittelua. Raudoituksen ankkurointiin ja betonointiin esitettyjen menetelmien toimivuus on syytä kokeilla käytännössä ja tehdä jatkokehitys näistä saatavien kokemusten pohjalta.
Resumo:
Mode of access: Internet.
Resumo:
Every year, particularly during the summer period, the Portuguese forests are devastated by forest fire that destroys their ecosystems. So in order to prevent these forest fires, public and private authorities frequently use methods for the reduction of combustible mass as the prescribed fire and the mechanical vegetation pruning. All of these methods of prevention of forest fires alter the vegetation layer and/or soil [1-2]. This work aimed the study of the variation of some chemical characteristics of soil that suffered prescribed fire. The studied an area was located in the Serra of Cabreira (Figure 1) with 54.6 ha. Twenty sampling points were randomly selected and samples were collected with a shovel before, just after the prescribed fire, and 125 and 196 days after that event. The parameters that were studied were: pH, soil moisture, organic matter and iron, magnesium and potassium total concentration. All the analysis followed International Standard Methodologies. This work allowed to conclude that: a) after the prescribed fire; i) the pH remained practically equal to the the initial value; ii) occurred a slight increase of the average of the organic matter contents and iron total contents; b) at the end of the sampling period compared to the initial values; i) the pH didn´t change significantly; ii) the average of the contents of organic matter decreased; and iii) the average of the total contents of Fe, Mg and K increased.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Charcoal analysis was conducted on sediment cores from three lakes to assess the relationship between the area and number of charcoal particles. Three charcoal-size parameters (maximum breadth, maximum length and area) were measured on sediment samples representing various vegetation types, including shrub tundra, boreal forest and temperate forest. These parameters and charcoal size-class distributions do not differ statistically between two sites where the same preparation technique (glycerine pollen slides) was used, but they differ for the same core when different techniques were applied. Results suggest that differences in charcoal size and size-class distribution are mainly caused by different preparation techniques and are not related to vegetation-type variation. At all three sites, the area and number concentrations of charcoal particles are highly correlated in standard pollen slides; 82–83% of the variability of the charcoal-area concentration can be explained by the particle-number concentration. Comparisons between predicted and measured area concentrations show that regression equations linking charcoal number and area concentrations can be used across sites as long as the same pollen-preparation technique is used. Thus it is concluded that it is unnecessary to measure charcoal areas in standard pollen slides – a time-consuming and tedious process.
Resumo:
The observed long-term decrease in the regional fire activity of Eastern Canada results in excessive accumulation of organic layer on the forest floor of coniferous forests, which may affect climate-growth relationships in canopy trees. To test this hypothesis, we related tree-ring chronologies of black spruce (Picea mariana (Mill.) B.S.P.) to soil organic layer (SOL) depth at the stand scale in the lowland forests of Quebec's Clay Belt. Late-winter and early-spring temperatures and temperature at the end of the previous year's growing season were the major monthly level environmental controls of spruce growth. The effect of SOL on climate-growth relationships was moderate and reversed the association between tree growth and summer aridity from a negative to a positive relationship: trees growing on thin organic layers were thus negatively affected by drought, whereas it was the opposite for sites with deep (>20-30 cm) organic layers. This indicates the development of wetter conditions on sites with thicker SOL. Deep SOL were also associated with an increased frequency of negative growth anomalies (pointer years) in tree-ring chronologies. Our results emphasize the presence of nonlinear growth responses to SOL accumulation, suggesting 20-30 cm as a provisional threshold with respect to the effects of SOL on the climate-growth relationship. Given the current climatic conditions characterized by generally low-fire activity and a trend toward accumulation of SOL, the importance of SOL effects in the black spruce ecosystem is expected to increase in the future.
Resumo:
Wood is a natural and traditional building material, as popular today as ever, and presents advantages. Physically, wood is strong and stiff, but compared with other materiais like steel is light and flexible. Wood material can absorb sound very effectively and it is a relatively good heat insulator. But dry wood does bum quite easily md produces a great deal ofheat energy. The main disadvantage is the high levei ofcombustion when exposed to fíre, where the point at which it catches fire is fi-om 200-400°C. After fu-e exposure, is need to determine if the charred wooden stmctures are safe for future use. Design methods require the use ofcomputer modelling to predict the fíre exposure and the capacity ofstructures to resist fhose action. Also, large or small scale experimental tests are necessary to calibrate and verify the numerical models. The thermal model is essential for wood stmctures exposed to fire, because predicts the charring rate as a fünction offire exposure. The charring rate calculation ofmost stmctural wood elements allows simple calculations, but is more complicated for situations where the fire exposure is non-standard and in wood elements protected with other materiais.
Resumo:
This paper presents a numerical approach with finite element method in order to predict both the behaviour and the performance of the wooden slabs with rectangular perforations under fire exposure. These typical constructions have good sound absorption, thermal insulation and relevant architectonic features, they are used in many civil engineering applications. These slabs are normally installed at lower level in building constructions essentially due to an easy maintenance requisite. Depending on the installation requirement, the perforated wooden slabs could have an additional insulation material inside the cavities. The proposed numerical model could be applied to different design constructive slab solutions. For this purpose a 3D numerical simulation was conducted with particular attention to the wood thermal properties variation with temperature. The numerical results were compared with those obtained experimentally in laboratory, for two wooden slabs. The fire resistance (performance criteria related to the insulation (I) and integrity (E)) was evaluated, as well as the effect of rectangular perforations into the residual cross section of the slab. This study was conducted in accordance with European Standard EN 1365-2 and using a fire resistance furnace which complies the requirements of EN 1363-1 in the experimental test.
Resumo:
Cover title.
Resumo:
June 1978.
Resumo:
Vols. for 2003- issued in 2 vols.