925 resultados para Stand alone operation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unbalanced or non-linear loads result in distorted stator currents and electromagnetic torque pulsations in stand-alone doubly fed induction generators (DFIGs). This study proposes the use of a proportional-integral repetitive control (PIRC) scheme so as to mitigate the levels of harmonic and unbalance at the stator terminals of the DFIG. The PIRC is structurally simpler and requires much less computation than existing methods. Analysis of the PIRC operation and the methodology to determine the control parameters is included. Simulation study as well as laboratory test measurements demonstrate clearly the effectiveness of the proposed PIRC control scheme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The operation of a stand-alone, as opposed to grid connected generation system, using a slip-ring induction machine as the electrical generator, is considered. In contrast to an alternator, a slip-ring induction machine can run at variable speed and still deliver constant frequency power to loads. This feature enables optimization of the system when the prime mover is inherently variable speed in nature eg. wind turbines, as well as diesel driven systems, where there is scope for economizing on fuel consumption. Experimental results from a system driven by a 44 bhp diesel engine are presented. Operation at subsynchronous as well as super-synchronous speeds is examined. The measurement facilitates the understanding of the system as well as its design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The decentralized power is characterised by generation of power nearer to the demand centers, focusing mainly on meeting local energy needs. A decentralized power system can function either in the presence of grid, where it can feed the surplus power generated to the grid, or as an independent/stand-alone isolated system exclusively meeting the local demands of remote locations. Further, decentralized power is also classified on the basis of type of energy resources used-non-renewable and renewable. These classifications along with a plethora of technological alternatives have made the whole prioritization process of decentralized power quite complicated for decision making. There is abundant literature, which has discussed various approaches that have been used to support decision making under such complex situations. We envisage that summarizing such literature and coming out with a review paper would greatly help the policy/decision makers and researchers in arriving at effective solutions. With such a felt need 102 articles were reviewed and features of several technological alternatives available for decentralized power, the studies on modeling and analysis of economic, environmental and technological asibilities of both grid-connected (GC) and stand-alone (SA) systems as decentralized power options are presented. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The lead-acid battery is often the weakest link in photovoltaic (PV) installations. Accordingly, various versions of lead-acid batteries, namely flooded, gelled, absorbent glass-mat and hybrid, have been assembled and performance tested for a PV stand-alone lighting system. The study suggests the hybrid VRLA batteries, which exhibit both the high power density of absorbent glass-mat design and the improved thermal properties of the gel design, to be appropriate for such an application. Among the VRLA-type batteries studied here water loss for the hybrid VRLA batteries is minimal and charge-acceptance during the service at high temperatures is better in relation to their AGM counterparts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of barcode technology to capture data on pharmacists' clinical interventions is described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

System efficiency and cost effectiveness are of critical importance for photovoltaic (PV) systems. This paper addresses the two issues by developing a novel three-port DC-DC converter for stand-alone PV systems, based on an improved Flyback-Forward topology. It provides a compact single-unit solution with a combined feature of optimized maximum power point tracking (MPPT), high step-up ratio, galvanic isolation and multiple operating modes for domestic and aerospace applications. A theoretical analysis is conducted to analyze the operating modes followed by simulation and experimental work. The paper is focused on a comprehensive modulation strategy utilizing both PWM and phase-shifted control that satisfies the requirement of PV power systems to achieve MPPT and output voltage regulation. A 250 W converter was designed and prototyped to provide experimental verification in term of system integration and high conversion efficiency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Asthma is now one of the most common long-term conditions in the UK. It is therefore important to develop a comprehensive appreciation of the healthcare and societal costs in order to inform decisions on care provision and planning. We plan to build on our earlier estimates of national prevalence and costs from asthma by filling the data gaps previously identified in relation to healthcare and broadening the field of enquiry to include societal costs. This work will provide the first UK-wide estimates of the costs of asthma. In the context of asthma for the UK and its member countries (ie, England, Northern Ireland, Scotland and Wales), we seek to: (1) produce a detailed overview of estimates of incidence, prevalence and healthcare utilisation; (2) estimate health and societal costs; (3) identify any remaining information gaps and explore the feasibility of filling these and (4) provide insights into future research that has the potential to inform changes in policy leading to the provision of more cost-effective care.

Methods and analysis Secondary analyses of data from national health surveys, primary care, prescribing, emergency care, hospital, mortality and administrative data sources will be undertaken to estimate prevalence, healthcare utilisation and outcomes from asthma. Data linkages and economic modelling will be undertaken in an attempt to populate data gaps and estimate costs. Separate prevalence and cost estimates will be calculated for each of the UK-member countries and these will then be aggregated to generate UK-wide estimates.

Ethics and dissemination Approvals have been obtained from the NHS Scotland Information Services Division's Privacy Advisory Committee, the Secure Anonymised Information Linkage Collaboration Review System, the NHS South-East Scotland Research Ethics Service and The University of Edinburgh's Centre for Population Health Sciences Research Ethics Committee. We will produce a report for Asthma-UK, submit papers to peer-reviewed journals and construct an interactive map.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many depressed patients report intrusive and distressing memories of specific events in their lives. Where present, these memories are believed to act as a maintaining factor. A series of ten patients with major depressive disorder and intrusive memories, many of them reporting severe, chronic, or recurrent episodes of depression, were given an average of 8.1 sessions of imagery rescripting as a stand-alone treatment. Hierarchical linear modelling demonstrated large treatment effects that were well maintained at one year follow-up. Seven patients showed reliable improvement, and six patients clinically significant improvement. These gains were achieved entirely by working through patients' visual imagination and without verbal challenging of negative beliefs. Spontaneous changes in beliefs, rumination, and behaviour were nevertheless observed. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper is to point out benefits as well as disadvantages associated with the use of locally available, not necessarily standardized, components in stand-alone electrical power systems at rural locations. Advantages and challenges arising when the direct involvement in design, construction and maintenance of the power system is reserved to people based in the area of implementation are discussed. The presented research is centered around one particular PV-diesel hybrid system in Tanzania; a case study in which technical and social aspects related to the particular power system are studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In this case report we presented the stand-alone posterior approach for hemivertebra resection with unilateral laminar hooks.Case report: The patient was male and five years old. The coronal and sagital X-Rays images showed a failure of vertebral formation, segmented hemivertebra of third lumbar vertebra. The segmented hemivertebra caused a thoracolumbar scoliosis from T12 to L4 (rightside convexity), of 30 degrees (Cobb angle). The patient was submitted to a hemivertebra resection from posterior approach with two unilateral laminars hooks stabilization (superior lamina in L2 and inferior lamina of L4) in association to a compression system and autologus bone graft. The coronal X-Ray image after surgery showed a partial improvement to 25 degrees (Cobb angle) between L2 and L4. After three years of follow up it was not observed system failure (hook pull-out), maintance of curve (25 degrees of Cobb angle) and correction of trunk inbalance.Conclusion: The hemivertebra resection with posterior approach is safe, with satisfactory correction of scoliosis curve, which means is a good choice for congenital scoliosis surgical treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the evaluation of different power electronic integrated converters suitable for photovoltaic applications, in order to reduce complexity and improve reliability. The rated voltages available in Photovoltaic (PV) modules have usually low values for applications such as regulated output voltages in stand-alone or grid-connected configurations. In these cases, a boost stage or a transformer will be necessary. Transformers have low efficiencies, heavy weights and have been used only when galvanic isolation is mandatory. Furthermore, high-frequency transformers increase the converter complexity. Therefore, the most usual topologies use a boost stage and one inverter stage cascaded. However, the complexity, size, weight, cost and lifetime might be improved considering the integration of both stages. In this context, some integrated converters are analyzed and compared in this paper in order to support future evaluations and trends for low power single-phase inverters for PV systems. Power decoupling, MPPT and Tri-State modulations are also considered. Finally, simulation and experimental results are presented and compared for the analyzed topologies. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Myocardial perfusion imaging with SPECT (SPECT-MPI) and 64-slice CT angiography (CTA) are both established techniques for the noninvasive evaluation of coronary artery disease (CAD). Three-dimensional (3D) SPECT/CT image fusion may offer an incremental diagnostic value by integrating both sets of information. We report our first clinical experiences with fused 3D SPECT/CT in CAD patients. METHODS: Thirty-eight consecutive patients with at least 1 perfusion defect on SPECT-MPI (1-d adenosine stress/rest SPECT with (99m)Tc-tetrofosmin) and 64-slice CTA were included. 3D volume-rendered fused SPECT/CT images were generated and compared with the findings from the side-by-side analysis with regard to coronary lesion interpretation by assigning the perfusion defects to their corresponding coronary lesion. RESULTS: The fused SPECT/CT images added information on pathophysiologic lesion severity in 27 coronary stenoses (22%) of 12 patients (29%) (P<0.001). Among 40 equivocal lesions on side-by-side analysis, the fused interpretation confirmed hemodynamic significance in 14 lesions and excluded functional relevance in 10 lesions. In 3 lesions, assignment of perfusion defect and coronary lesion appeared to be reliable on side-by-side analysis but proved to be inaccurate on fused interpretation. Added diagnostic information by SPECT/CT was more commonly found in patients with stenoses of small vessels (P=0.004) and involvement of diagonal branches (P=0.01). CONCLUSION: In addition to being intuitively convincing, 3D SPECT/CT fusion images in CAD may provide added diagnostic information on the functional relevance of coronary artery lesions.