953 resultados para Stability studies


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Power system stabilizers (PSS) work well at the particular network configuration and steady state conditions for which they were designed. Once conditions change, their performance degrades. This can be overcome by an intelligent nonlinear PSS based on fuzzy logic. Such a fuzzy logic power system stabilizer (FLPSS) is developed, using speed and power deviation as inputs, and provides an auxiliary signal for the excitation system of a synchronous motor in a multimachine power system environment. The FLPSS's effect on the system damping is then compared with a conventional power system stabilizer's (CPSS) effect on the system. The results demonstrate an improved system performance with the FLPSS and also that the FLPSS is robust

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: HIV-1 Pr55gag virus-like particles (VLPs) expressed by baculovirus in insect cells are considered to be a very promising HIV-1 vaccine candidate, as they have been shown to elicit broad cellular immune responses when tested in animals, particularly when used as a boost to DNA or BCG vaccines. However, it is important for the VLPs to retain their structure for them to be fully functional and effective. The medium in which the VLPs are formulated and the temperature at which they are stored are two important factors affecting their stability. FINDINGS We describe the screening of 3 different readily available formulation media (sorbitol, sucrose and trehalose) for their ability to stabilise HIV-1 Pr55gag VLPs during prolonged storage. Transmission electron microscopy (TEM) was done on VLPs stored at two different concentrations of the media at three different temperatures (4[degree sign]C, --20[degree sign]C and -70[degree sign]C) over different time periods, and the appearance of the VLPs was compared. VLPs stored in 15% trehalose at -70[degree sign]C retained their original appearance the most effectively over a period of 12 months. VLPs stored in 5% trehalose, sorbitol or sucrose were not all intact even after 1 month storage at the temperatures tested. In addition, we showed that VLPs stored under these conditions were able to be frozen and re-thawed twice before showing changes in their appearance. Conclusions Although the inclusion of other analytical tools are essential to validate these preliminary findings, storage in 15% trehalose at -70[degree sign]C for 12 months is most effective in retaining VLP stability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Simple and rapid HPLC, GC, and TLC procedures have been developed for detection and determination of nimesulide, a non-pharmacopeial drug, in preformulation and dosage form. Use of these techniques has enabled separation of impurities and the precursor in the bulk material and in formulations. Isocratic reversed-phase HPLC was performed on a C-18 column with methanol-water-acetic acid, 67:32:1 (v/v), as mobile phase and UV detection at 230 nm. Calibration curves were linear over the concentration range 100-1000 mug mL(-1) with a good correlation coefficient (0.9993) and a coefficient of variation of 1.5%. Gas chromatography was performed on an OV-17 packed column with temperature programming and flame-ionization detection. The lower limit of determination by HPLC and GC was 4 ppm. Thin-layer chromatography of nimesulide was performed on silica gel G with toluene-ethyl acetate, 8:2, as mobile phase. Stability testing of the drug was performed under different temperature, humidity, and UV-radiation conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Long-term stability studies of particle storage rings can not be carried out using conventional numerical integration algorithms. We require symplectic integration algorithms which are both fast and accurate. In this paper, we study a symplectic integration method wherein the sym-plectic map representing the Hamiltonian system is refactorized using polynomial symplectic maps. This method is used to perform long term integration on a particle storage ring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nitrofuran antibiotics cannot be used in food production within the European Union because of their potential health risks to consumers. The recent discovery of their widespread use in global food industries and the finding of semicarbazide in baby food as a result of packaging contamination have focused attention on the toxicity and stability of these drugs and their metabolites. The stability of the nitrofuran marker residues 3-amino-2-oxazolidinone (AOZ), 3-amino-5-morpholinomethyl-2-oxazolidone (AMOZ), 1-aminohydantoin (AHD) and semicarbazide (SEM) were tested. Muscle and liver of nitrofuran treated pigs were cooked by frying, grilling, roasting and microwaving. Between 67 and 100% of the residues remained after cooking, demonstrating that these metabolites are largely resistant to conventional cooking techniques and will continue to pose a health risk. The concentration of metabolites in pig muscle and liver did not drop significantly during 8 months of storage at -20 degrees C. Metabolite stock and working standard solutions in methanol were also stable for 10 months at 4 degrees C. Only a 10 ng ml(-1) solution of SEM showed a small drop in concentration over this extended storage period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High resolution synchrotron radiation core level photoemission measurements have been used to undertake a comparative study of the high temperature stability of ultrathin Al2O3 layers deposited by atomic layer deposition (ALD) on both sulphur passivated and native oxide covered InGaAs. The residual interfacial oxides between sulphur passivated InGaAs and the ultrathin Al2O3 layer can be substantially removed at high temperature (up to 700 °C) without impacting on the InGaAs stoichiometry while significant loss of indium was recorded at this temperature on the native oxide InGaAs surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans cette étude, la stabilité de préparations intraveineuses de cyclosporine (0.2 et 2.5 mg/mL dans NaCl 0.9% ou dextrose 5%) entreposées dans des seringues de polypropylène, des sacs de polypropylène-polyoléfine et des sacs de vinyle acétate d’éthylène a été évaluée. Une méthode HPLC indicatrice de la stabilité à base de méthanol a été développée et validée suite a des études de dégradation forcée. Les solutions évaluées ont été préparées de façon aseptique, puis entreposées à 25°C. La stabilité chimique a été évaluée par HPLC et la stabilité physique a été évaluée par inspection visuelle et aussi par diffusion dynamique de la lumière (DLS). Tous les échantillons sont demeurés stables chimiquement et physiquement dans des sacs de polypropylène-polyoléfine (>98% de cyclosporine récupérée après 14 jours). Lorsqu’entreposés dans des seringues de polypropylène, des contaminants ont été extraits des composantes de la seringue. Toutefois, aucune contamination n’a été observée après 10 min de contact entre la préparation de cyclosporine non-diluée et ces mêmes seringues. Les préparations de 2.5 mg/mL entreposées dans des sacs de vinyle acétate d’éthylène sont demeurés stables chimiquement et physiquement (>98% de cyclosporine récupérée après 14 jours). Toutefois, une adsorption significative a été observée avec les échantillons 0.2 mg/mL entreposés dans des sacs de vinyle acétate d’éthylène (<90% de cyclosporine récupéré après 14 jours). Une étude cinétique a démontré une bonne corrélation linéaire entre la quantité adsorbée et la racine carrée du temps de contact (r2 > 0.97). Un nouveou modèle de diffusion a été établi. En conclusion, les sacs de polypropylène-polyoléfine sont le meilleur choix; les seringues de polypropylène présentent un risque de contamination, mais sont acceptables pour un transfert rapide. Les sacs de vinyle acétate d’éthylène ne peuvent être recommandés à cause d’un problème d’adsorption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thermostability (TS) and efficacy offered by live vaccines against Newcastle disease strains B 1, La Sota, VG-GA and Ulster, produced or imported by four Brazilian laboratories, were evaluated during their validity period. Kinetic profiles were obtained from samples conserved in refrigerators during 0, 4, 8, 12, 16, 20 and 24 months after their manufacturing. The statistical analysis of the vaccine titre effect obtained by the fresh air (FA) method showed that the vaccine profiles were parallel and coincident, presenting a significant descending trend. The vaccine titres and efficiency proofs at the end of the validity period were above the level of legislation requirements and showed an average loss in titre of 0.40 and 0.66 log(10), within the first and second validity years, respectively. The titre obtained by TS, within the month after manufacturing, had no significant difference from the titre obtained by FA within 24 months after manufacturing, being their pairs of observations positively correlated (r = 0,49, p = 0.0003), showing that the TS method, which anticipates the vaccines' performance at the end of the validity period, can substitute the FA method 24 months after manufacturing. (C) 2009 The International Association for Biologicals. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper presents a method for security control of electric power systems effected by generation reallocation, determined by sensitivity analysis and optimisation. The model is developed considering the dynamic aspects of the network (transient stability). Security control methodology is developed using sensitivity analysis of the security margin in relation to the mechanical power of synchronous machines in the system. The power reallocated to each machine is determined by means of linear programming. To illustrate the proposed methodology, an example is presented which considers a multimachine system composed of 10 synchronous machines, 45 buses, and 72 transmission lines, based on the configuration of a southern Brazilian system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Liposoluble vitamin C derivatives, such as tetra-isopalmitoyl ascorbic acid (IPAA), are often used in dermocosmetic products due to their higher stability than vitamin C free form as well as its proposed effects in skin; however, there are no studies analyzing IPAA stability or its in vivo effects when present in dermocosmetic formulations. Thus, this study aimed to evaluate chemical stability and pre-clinical and clinical efficacy of dermocosmetic formulations containing IPAA in skin hydration and microrelief. Chemical stability of the formulations added with 1% IPAA was evaluated by heat stress during 35 days by HPLC. For pre-clinical evaluation, experimental formulations were topically applied on hairless skin mice during 5 days and animal skins were analyzed by non-invasive biophysic techniques (water content of stratum corneum, TEWL, viscoelasticity, and microrelief) and by histopathological studies. For clinical efficacy tests, the formulations were topically applied to the forearm and face of human volunteers, and 3 h and 15 days after applications, the skins were evaluated by the same non-invasive techniques mentioned before. Results showed that formulations containing IPAA had medium stability and had pronounced moisturizing effects on stratum corneum and on viable epidermis. These formulations also improved skin microrelief especially in relation to skin smoothness and roughness. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-fouling surfaces that resist non-specific adsorption of proteins, bacteria, and higher organisms are of particular interest in diverse applications ranging from marine coatings to diagnostic devices and biomedical implants. Poly(ethylene glycol) (PEG) is the most frequently used polymer to impart surfaces with such non-fouling properties. Nevertheless, limitations in PEG stability have stimulated research on alternative polymers that are potentially more stable than PEG. Among them, we previously investigated poly(2-methyl-2-oxazoline) (PMOXA), a peptidomimetic polymer, and found that PMOXA shows excellent anti-fouling properties. Here, we compare the stability of films self-assembled from graft copolymers exposing a dense brush layer of PEG and PMOXA side chains, respectively, in physiological and oxidative media. Before media exposure both film types prevented the adsorption of full serum proteins to below the detection limit of optical waveguide in situ measurements. Before and after media exposure for up to 2 weeks, the total film thickness, chemical composition, and total adsorbed mass of the films were quantified using variable angle spectroscopic ellipsometry (VASE), X-ray photoelectron spectroscopy (XPS), and optical waveguide lightmode spectroscopy (OWLS), respectively. We found (i) that PMOXA graft copolymer films were significantly more stable than PEG graft copolymer films and kept their protein-repellent properties under all investigated conditions and (ii) that film degradation was due to side chain degradation rather than due to copolymer desorption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents results of the validity study of the use of MATLAB/Simulink synchronous-machine block for power-system stability studies. Firstly, the waveforms of the theoretical synchronous-generator short-circuit currents are described. Thereafter, the comparison between the currents obtained through the simulation model in the sudden short-circuit test, are compared to the theoretical ones. Finally, the factory tests of two commercial generating units are compared to the response of the synchronous generator simulation block during sudden short-circuit, set with the same real data, with satisfactory results. This results show the validity of the use of this generator block for power plant simulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The functional role of residue Tyr-19 of Chromatium vinosum HiPIP has been evaluated by site-directed mutagenesis experiments. The stability of the [Fe4S4] cluster prosthetic center is sensitive to side-chain replacements. Polar residues result in significant instability, while nonpolar residues (especially with aromatic side chains) maintain cluster stability. Two-dimensional NMR data of native and mutant HiPIPs are consistent with a model where Tyr-19 serves to preserve the structural rigidity of the polypeptide backbone, thereby maintaining a hydrophobic barrier for exclusion of water from the cluster cavity. Solvent accessibility results in more facile oxidation of the cluster by atmospheric oxygen, with subsequent rapid hydrolysis of the [Fe4S4]3+ core.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research carried out in this thesis was mainly concerned with the effects of large induction motors and their transient performance in power systems. Computer packages using the three phase co-ordinate frame of reference were developed to simulate the induction motor transient performance. A technique using matrix algebra was developed to allow extension of the three phase co-ordinate method to analyse asymmetrical and symmetrical faults on both sides of the three phase delta-star transformer which is usually required when connecting large induction motors to the supply system. System simulation, applying these two techniques, was used to study the transient stability of a power system. The response of a typical system, loaded with a group of large induction motors, two three-phase delta-star transformers, a synchronous generator and an infinite system was analysed. The computer software developed to study this system has the advantage that different types of fault at different locations can be studied by simple changes in input data. The research also involved investigating the possibility of using different integrating routines such as Runge-Kutta-Gill, RungeKutta-Fehlberg and the Predictor-Corrector methods. The investigation enables the reduction of computation time, which is necessary when solving the induction motor equations expressed in terms of the three phase variables. The outcome of this investigation was utilised in analysing an introductory model (containing only minimal control action) of an isolated system having a significant induction motor load compared to the size of the generator energising the system.