971 resultados para Split Grammar
Resumo:
Passive solar building design is the process of designing a building while considering sunlight exposure for receiving heat in winter and rejecting heat in summer. The main goal of a passive solar building design is to remove or reduce the need of mechanical and electrical systems for cooling and heating, and therefore saving energy costs and reducing environmental impact. This research will use evolutionary computation to design passive solar buildings. Evolutionary design is used in many research projects to build 3D models for structures automatically. In this research, we use a mixture of split grammar and string-rewriting for generating new 3D structures. To evaluate energy costs, the EnergyPlus system is used. This is a comprehensive building energy simulation system, which will be used alongside the genetic programming system. In addition, genetic programming will also consider other design and geometry characteristics of the building as search objectives, for example, window placement, building shape, size, and complexity. In passive solar designs, reducing energy that is needed for cooling and heating are two objectives of interest. Experiments show that smaller buildings with no windows and skylights are the most energy efficient models. Window heat gain is another objective used to encourage models to have windows. In addition, window and volume based objectives are tried. To examine the impact of environment on designs, experiments are run on five different geographic locations. Also, both single floor models and multi-floor models are examined in this research. According to the experiments, solutions from the experiments were consistent with respect to materials, sizes, and appearance, and satisfied problem constraints in all instances.
Resumo:
Thesis (Master's)--University of Washington, 2016-09
Resumo:
Margaret Kettle examines grammar, its image problem and some new developments aimed at improving its teaching and learning in the TESOL classroom.
Resumo:
Digital Scenography and traditional Stage Design for the US premiere of Split Britches "The Lost Lounge" - Lois Weaver and Peggy Shaw, Dixons Place New York, December 2009 Digital Scenography and traditional Stage Design for the UK premiere of Split Britches "The Lost Lounge" - Lois Weaver and Peggy Shaw, The Great Hall, Peoples Palace, London, March 2010
Resumo:
Pipe insulation between the collector and storage tank on pumped storage (commonly called split), solar water heaters can be subject to high temperatures, with a maximum equal to the collector stagnation temperature. The frequency of occurrence of these temperatures is dependent on many factors including climate, hot water demand, system size and efficiency. This paper outlines the findings of a computer modelling study to quantify the frequency of occurrence of pipe temperatures of 80 degrees Celsius or greater at the outlet of the collectors for these systems. This study will help insulation suppliers determine the suitability of their materials for this application. The TRNSYS program was used to model the performance of a common size of domestic split solar system, using both flat plate and evacuated tube, selective surface collectors. Each system was modelled at a representative city in each of the 6 climate zones for Australia and New Zealand, according to AS/NZS4234 - Heat Water Systems - Calculation of energy consumption, and the ORER RECs calculation method. TRNSYS was used to predict the frequency of occurrence of the temperatures that the pipe insulation would be exposed to over an average year, for hot water consumption patterns specified in AS/NZS4234, and for worst case conditions in each of the climate zones. The results show; * For selectively surfaced, flat plate collectors in the hottest location (Alice Sprints) with a medium size hot water demand according to AS/NZS2434, the annual frequency of occurrence of temperatures at and above 80 degrees Celsius was 33 hours. The frequency of temperatures at and above 140 degrees Celsius was insignificant. * For evacuated tube collectors in the hottest location (Alice Springs), the annual frequency of temperatures at and above 80 degrees Celsius was 50 hours. Temperatures at and above 140 degrees Celsius were significant and were estimated to occur for more than 21 hours per year in this climate zone. Even in Melbourne, temperatures at and above 80 degrees can occur for 12 hours per year and at and above 140 degrees for 5 hours per year. * The worst case identified was for evacuated tube collectors in Alice Springs, with mostly afternoon loads in January. Under these conditions, the frequency of temperatures at and above 80 degrees Celsius was 10 hours for this month only. Temperatures at and above 140 degrees Celsius were predicted to occur for 5 hours in January.
Resumo:
Appropriate pipe insulation on domestic, pumped storage (split), solar water heating systems forms an integral part of energy conservation measures of well engineered systems. However, its importance over the life of the system is often overlooked. This study outlines the findings of computer modelling to quantify the energy and cost savings by using pipe insulation between the collector and storage tank. System sizes of 270 Litre storage tank, together with either selectively surfaced, flat plate collectors (4m2 area), or 30 evacuated tube collectors, were used. Insulation thicknesses of 13mm and 15mm, pipe runs both ways of 10, 15 and 20 metres and both electric and gas boosting of systems were all considered. The TRNSYS program was used to model the system performance at a representative city in each of the 6 climate zones for Australia and New Zealand, according to AS/NZS4234 – Heat Water Systems – Calculation of energy consumption and the ORER RECs calculation method. The results show: Energy savings from pipe insulation are very significant, even in mild climates such as Rockhampton. Across all climates zones, savings ranged from 0.16 to 3.5GJ per system per year, or about 2 to 23 percent of the annual load. There is very little advantage in increasing the insulation thickness from 13 to 15mm. For electricity at 19c/kWh and gas at 2 c/MJ, cost savings of between $27 and $100 per year are achieved across the climate zones. Both energy and cost savings would increase in colder climates with increased system size, solar contribution and water temperatures. The pipe insulation substantially improves the solar contribution (or fraction) and Renewable Energy Certificates (RECs), as well as giving small savings in circulating pump running costs in milder climates. Solar contribution increased by up to 23 percent points and RECs by over 7 in some cases. The study highlights the need to install and maintain the integrity of appropriate pipe insulation on solar water heaters over their life time in Australia and New Zealand.
Resumo:
The release of the Australian Curriculum English (ACE) by the Australian Curriculum, Assessment and Reporting Authority (ACARA) has revived debates about the role of grammar as English content knowledge. We consider some of the discussion circulating in the mainstream media vis-à-vis the intent of the ACE. We conclude that this curriculum draws upon the complementary tenets of traditional Latin-based grammar and systemic functional linguistics across the three strands of Language, Literature and Literacy in innovative ways. We argue that such an approach is necessary for working with contemporary multimodal and cross-cultural texts. To demonstrate the utility of this new approach, we draw out a set of learning outcomes from Year 6 and then map out a framework for relating the outcomes to the form and function of multimodal language. As a case in point, our analysis is of two online Coca-Cola advertising texts, one each from South Korea and Australia.
Resumo:
Increasingly, studies are reported that examine how conceptual modeling is conducted in practice. Yet, typically the studies to date have examined in isolation how modeling grammars can be, or are, used to develop models of information systems or organizational processes, without considering that such modeling is typically done by means of a modeling tool that extends the modeling functionality offered by a grammar through complementary features. This paper extends the literature by examining how the use of seven different features of modeling tools affects usage beliefs users develop when using modeling grammars for process modeling. We show that five distinct tool features positively affect usefulness, ease of use and satisfaction beliefs of users. We offer a number of interpretations about the findings. We also describe how the results inform decisions of relevance to developers of modeling tools as well as managers in charge for making modeling-related investment decisions.
Resumo:
Process modeling grammars are used to create scripts of a business domain that a process-aware information system is intended to support. A key grammatical construct of such grammars is known as a Gateway. A Gateway construct is used to describe scenarios in which the workflow of a process diverges or converges according to relevant conditions. Gateway constructs have been subjected to much academic discussion about their meaning, role and usefulness, and have been linked to both process-modeling errors and process-model understandability. This paper examines perceptual discriminability effects of Gateway constructs on an individual's abilities to interpret process models. We compare two ways of expressing two convergence and divergence patterns – Parallel Split and Simple Merge – implemented in a process modeling grammar. On the basis of an experiment with 98 students, we provide empirical evidence that Gateway constructs aid the interpretation of process models due to a perceptual discriminability effect, especially when models are complex. We discuss the emerging implications for research and practice, in terms of revisions to grammar specifications, guideline development and design choices in process modeling.
Resumo:
This project was an observational study of outpatients following lower limb surgical procedures for removal of skin cancers. Findings highlight a previously unreported high surgical site failure rate. Results also identified four potential risk factors (increasing age, presence of leg pain, split skin graft and haematoma) which negatively impact on surgical site healing in this population.