988 resultados para Speed Detection.


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Texas Department of Transportation, Research and Technology Transfer Office, Austin

Relevância:

70.00% 70.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Indiana Department of Transportation, Indianapolis

Relevância:

70.00% 70.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Federal Highway Administration, Washington, D.C.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Federal Highway Administration, Environmental Design and Control Division, Washington, D.C.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En los últimos tiempos, los radares han dejado de ser instrumentos utilizados únicamente en aviación, defensa y detección de velocidad. El avance de la tecnología de radiofrecuencia ha permitido la reducción de coste, tamaño y consumo de los componentes radar. Esto ha permitido que cada sea más frecuente el uso del radar en elementos de nuestra vida cotidiana tales como la automoción, la seguridad, la medida de líquidos… Este proyecto se basa en uno de estos nuevos componentes de bajo coste y pequeño tamaño, el transceptor BGT24MTR11. El BGTR24MTR11 integra transmisor, VCO y receptor, los elementos principales para la creación de un radar Doppler en la banda de frecuencia ISM 24-24,25 GHz. A partir de la placa de evaluación de ese transceptor, se aborda el diseño de un prototipo/demostrador de radar Doppler CW en la banda de 24 GHz. Para la generación de frecuencia se utiliza la placa de evaluación del PLL HMC702 y se ha diseñado un PCB a medida cuyas funciones son las de alimentación, programación y amplificación de las señales recibidas por el prototipo. Por último, se comprueba el correcto funcionamiento del prototipo y se verifica su funcionamiento mediante la simulación de dos escenarios de prueba. ABSTRACT. In the recent times, radar systems have changed of being tools used only in aviation, defence and speed detection. Radiofrequency technology improvements have allowed a cost, size and power consumption of the radar components. This is the reason because each time is more frequent the use of radar in elements of our daily life such as automotive, security, liquid measurements… This Project is base don one of this low power and size components, the MMIC transceptor BGT24MTR11. This transceptor integrates the main components needed to make a Doppler radar in the ISM Band (24-24 GHz), the transmitter, the receiver with the low noise amplifier and the VCO. Using the evaluation board of this transceptor, this Project approach the design of a CW Doppler radar prototype/demonstrator in the frequency band of 24 GHz. The frequency generation is based on the use of the HMC702 PLL evaluation board. Moreover, it has been designed a custom PCB whose funcionts are the power supply, programation and amplification of the signals received by the prototype. At the end, the correct operation of the prototype is verified and it is tested simulating two different test scenarios.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present the first evaluation of a novel molecular assay, the Speed-oligo Direct Mycobacterium tuberculosis (SO-DMT) assay, which is based on PCR combined with a dipstick for the detection of mycobacteria and the specific identification of M. tuberculosis complex (MTC) in respiratory specimens. A blind evaluation was carried out in two stages: first, under experimental conditions on convenience samples comprising 20 negative specimens, 44 smear- and culture-positive respiratory specimens, and 11 sputa inoculated with various mycobacterium-related organisms; and second, in the routine workflow of 566 fresh respiratory specimens (4.9% acid-fast bacillus [AFB] smear positives, 7.6% MTC positives, and 1.8% nontuberculous mycobacteria [NTM] culture positives) from two Mycobacterium laboratories. SO-DMT assay showed no reactivity in any of the mycobacterium-free specimens or in those with mycobacterium-related organisms. Compared to culture, the sensitivity in the selected smear-positive specimens was 0.91 (0.92 for MTC and 0.90 for NTM), and there was no molecular detection of NTM in a tuberculosis case or vice versa. With respect to culture and clinical data, the sensitivity, specificity, and positive and negative predictive values for the SO-DMT system in routine specimens were 0.76 (0.93 in smear positives [1.0 for MTC and 0.5 for NTM] and 0.56 in smear negatives [0.68 for MTC and 0.16 for NTM]), 0.99, 0.85 (1.00 in smear positives and 0.68 in smear negatives), and 0.97, respectively. Molecular misidentification of NTM cases occurred when testing 2 gastric aspirates from two children with clinically but not microbiologically confirmed lung tuberculosis. The SO-DMT assay appears to be a fast and easy alternative for detecting mycobacteria and differentiating MTC from NTM in smear-positive respiratory specimens.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fluid handling systems account for a significant share of the global consumption of electrical energy. They also suffer from problems, which reduce their energy efficiency and increase life-cycle costs. Detecting or predicting these problems in time can make fluid handling systems more environmentally and economically sustainable to operate. In this Master’s Thesis, significant problems in fluid systems were studied and possibilities to develop variable-speed-drive-based detection methods for them was discussed. A literature review was conducted to find significant problems occurring in fluid handling systems containing pumps, fans and compressors. To find case examples for evaluating the feasibility of variable-speed-drive-based methods, queries were sent to industrial companies. As a result of this, the possibility to detect heat exchanger fouling with a variable-speed drive was analysed with data from three industrial cases. It was found that a mass flow rate estimate, which can be generated with a variable speed drive, can be used together with temperature measurements to monitor a heat exchanger’s thermal performance. Secondly, it was found that the fouling-related increase in the pressure drop of a heat exchanger can be monitored with a variable speed drive. Lastly, for systems where the flow device is speed controlled with by a pressure measurement, it was concluded that increasing rotational speed can be interpreted as progressing fouling in the heat exchanger.