889 resultados para Space heating


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To achieve CO2 emissions reductions the UK Building Regulations require developers of new residential buildings to calculate expected CO2 emissions arising from their energy consumption using a methodology such as Standard Assessment Procedure (SAP 2005) or, more recently SAP 2009. SAP encompasses all domestic heat consumption and a limited proportion of the electricity consumption. However, these calculations are rarely verified with real energy consumption and related CO2 emissions. This paper presents the results of an analysis based on weekly head demand data for more than 200 individual flats. The data is collected from recently built residential development connected to a district heating network. A methodology for separating out the domestic hot water use (DHW) and space heating demand (SH) has been developed and compares measured values to the demand calculated using SAP 2005 and 2009 methodologies. The analysis shows also the variance in DHW and SH consumption between both size of the flats and tenure (privately owned or housing association). Evaluation of the space heating consumption includes also an estimation of the heating degree day (HDD) base temperature for each block of flats and its comparison to the average base temperature calculated using the SAP 2005 methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A thermal energy store corrects the misalignment of heating demand in the winter relative to solar thermal energy gathered in the summer. This thesis reviews the viability of a solar charged hot water tank thermal energy store for a school at latitude 56.25N, longitude -120.85W

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"DSE-2322-1."

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Dynamic system test methods for heating systems were developed and applied by the institutes SERC and SP from Sweden, INES from France and SPF from Switzerland already before the MacSheep project started. These test methods followed the same principle: a complete heating system – including heat generators, storage, control etc., is installed on the test rig; the test rig software and hardware simulates and emulates the heat load for space heating and domestic hot water of a single family house, while the unit under test has to act autonomously to cover the heat demand during a representative test cycle. Within the work package 2 of the MacSheep project these similar – but different – test methods were harmonized and improved. The work undertaken includes:  • Harmonization of the physical boundaries of the unit under test. • Harmonization of the boundary conditions of climate and load. • Definition of an approach to reach identical space heat load in combination with an autonomous control of the space heat distribution by the unit under test. • Derivation and validation of new six day and a twelve day test profiles for direct extrapolation of test results.   The new harmonized test method combines the advantages of the different methods that existed before the MacSheep project. The new method is a benchmark test, which means that the load for space heating and domestic hot water preparation will be identical for all tested systems, and that the result is representative for the performance of the system over a whole year. Thus, no modelling and simulation of the tested system is needed in order to obtain the benchmark results for a yearly cycle. The method is thus also applicable to products for which simulation models are not available yet. Some of the advantages of the new whole system test method and performance rating compared to the testing and energy rating of single components are:  • Interaction between the different components of a heating system, e.g. storage, solar collector circuit, heat pump, control, etc. are included and evaluated in this test. • Dynamic effects are included and influence the result just as they influence the annual performance in the field. • Heat losses are influencing the results in a more realistic way, since they are evaluated under "real installed" and representative part-load conditions rather than under single component steady state conditions.   The described method is also suited for the development process of new systems, where it replaces time-consuming and costly field testing with the advantage of a higher accuracy of the measured data (compared to the typically used measurement equipment in field tests) and identical, thus comparable boundary conditions. Thus, the method can be used for system optimization in the test bench under realistic operative conditions, i.e. under relevant operating environment in the lab.   This report describes the physical boundaries of the tested systems, as well as the test procedures and the requirements for both the unit under test and the test facility. The new six day and twelve day test profiles are also described as are the validation results.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Nearly a third of UK gas and electricity is used in homes, of which 80% is for space heating and hot water provision. Rising consumer bills, concerns about climate change and the surge in personal digital technology use has provoked the development of intelligent domestic heating controls. Whilst the need for having suitable control of the home heating system is essential for reducing domestic energy use, these heating controls rely on appropriate user interaction to achieve a saving and it is unclear whether these ‘smart’ heating controls enhance the use of domestic heating or reduce energy demand. This paper describes qualitative research undertaken with a small sample of UK householders to understand how people use new heating controls installed in their homes and what the requirements are for improved smart heating control design. The paper identifies, against Nielsen’s usability heuristics, the divergence between the householder’s use, understanding and expectations of the heating system and the actual design of the system. Digital and smart heating control systems should be designed to maximise usability so that they can be effectively used for efficient heating control by all users. The research highlights the need for development of new systems to readdress the needs of users and redefine the system requirements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O consumo de energia a nível mundial tem atingido valores históricos, devido ao crescimento da população mundial e ao aumento do consumo per capita. Nesta medida é extremamente importante existirem alternativas para que a redução do consumo de energia de todos os países seja uma realidade, evitando também as consequências ambientais, em particular as alterações climáticas, resultantes da utilização intensiva de combustíveis fósseis. Portugal, tal como outros países da União Europeia, tem que cumprir metas, pelo que é urgente encontrarem-se soluções de forma a diminuir o consumo de energia sem interferir com o nosso dia-a-dia. A cidade do Porto, tal como qualquer cidade, precisa de imensa energia desde os transportes até à indústria, passando pelos edifícios. Os edifícios, residenciais e de serviços, são responsáveis por mais de 50% de energia primária consumida no concelho do Porto, sendo que aos edifícios residenciais corresponde um consumo de 1.473 GWh/ano de energia primária, o que é um valor elevado. Numa primeira parte deste trabalho foi efetuado um levantamento de informação caracterizando a cidade do Porto relativamente ao seu edificado e consumos energéticos. Numa segunda parte propuseram-se medidas para reduzir o consumo para cada tipo de utilização de energia, nomeadamente preparação de refeições, AQS (água quente sanitária), aquecimento ambiente, frio (frigorífico, arcas, etc.), outros e iluminação. Para cada um destes tipos de utilização estudou-se, sempre que possível, a evolução do longo do tempo (2004 a 2012) e possíveis cenários de evolução para o futuro. Para além disso, também se estudou a evolução do mix de produção de energia elétrica de 2004 até 2012 e previsões da evolução do mix para o futuro. Nesta análise foi tido em conta o aspeto ambiental contabilizando-se, sempre que possível, as emissões de poluentes resultantes do consumo de energia. Por fim, efetuou-se uma avaliação técnica, ambiental e económica das medidas propostas. Pode dizer-se que a maioria das medidas propostas a serem implementadas conduziria a uma redução do consumo de energia e consequentemente a uma diminuição das emissões de poluentes, em particular dos gases com efeito de estufa (CO2). Em termos técnicos a maioria das medidas pode ser aplicada embora algumas delas envolvam custos de investimento significativos. Dada a conjuntura atual, seria importante obter o financiamento necessário para a implementação das medidas propostas e a divulgação de medidas já existentes, tais como os programas para AQS e janelas eficientes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A composting Heat Extraction Unit (HEU) was designed to utilise waste heat from decaying organic matter for a variety of heating application The aim was to construct an insulated small scale, sealed, organic matter filled container. In this vessel a process fluid within embedded pipes would absorb thermal energy from the hot compost and transport it to an external heat exchanger. Experiments were conducted on the constituent parts and the final design comprised of a 2046 litre container insulated with polyurethane foam and kingspan with two arrays of qualpex piping embedded in the compost to extract heat. The thermal energy was used in horticultural trials by heating polytunnels using a radiator system during a winter/spring period. The compost derived energy was compared with conventional and renewable energy in the form of an electric fan heater and solar panel. The compost derived energy was able to raise polytunnel temperatures to 2-3°C above the control, with the solar panel contributing no thermal energy during the winter trial and the electric heater the most efficient maintaining temperature at its preset temperature of 10°C. Plants that were cultivated as performance indicators showed no significant difference in growth rates between the heat sources. A follow on experiment conducted using special growing mats for distributing compost thermal energy directly under the plants (Radish, Cabbage, Spinach and Lettuce) displayed more successful growth patterns than those in the control. The compost HEU was also used for more traditional space heating and hot water heating applications. A test space was successfully heated over two trials with varying insulation levels. Maximum internal temperature increases of 7°C and 13°C were recorded for building U-values of 1.6 and 0.53 W/m2K respectively using the HEU. The HEU successfully heated a 60 litre hot water cylinder for 32 days with maximum water temperature increases of 36.5°C recorded. Total energy recovered from the 435 Kg of compost within the HEU during the polytunnel growth trial was 76 kWh which is 3 kWh/day for the 25 days when the HEU was activated. With a mean coefficient of performance level of 6.8 calculated for the HEU the technology is energy efficient. Therefore the compost HEU developed here could be a useful renewable energy technology particularly for small scale rural dwellers and growers with access to significant quantities of organic matter

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Estudi elaborat a partir d’una estada a Çukurova University, Turquia, al juliol del 2006. L’emmagatzematge d’energia tèrmica ha atret interès en aplicacions tèrmiques com l’aigua calenta, la calefacció i l’aire condicionat. Aquests sistemes són útils per corregir la no coincidència entre la oferta i la demanda d’energia. Principalment hi ha dos tipus de sistemes d’emmagatzematge d’energia tèrmica, emmagatzematge amb calor sensible i amb calor latent. L’emmagatzematge amb calor latent és particularment atractiu degut a la seva habilitat de donar una densitat d’emmagatzematge d’energia més alt i la seva característica d’emmagatzemar calor a una temperatura constant corresponent a la temperatura de transició de fase de la substància emmagatzemadora de calor. Les salts hidratades orgàniques tenen certes avantatges com a materials d’emmagatzematge de calor latent sobre els materials orgànics. En canvi, quan les salts hidratades s’utilitzen com a materials de canvi de fase (PCM) apareixen alguns problemes en les aplicacions d’emmagatzematge de calor latent. Aquests són el subrefredament de les salts hidratades quan es congelen degut a les seves dèbils propietats de nucleació, i la separació de fase que hi apareix degut a una fusió incongruent. En aquest estudi, s’estabilitza sal de Glauber (Na2SO4.10H2O) amb diferents concentracions de poliacrilamida i gelatina per prevenir la fusió incongruent. Per prevenir el subrefredament s’utilitza un agent nucleant amb una estructura cristal•lina semblant a la de la sal de Glauber. La capacitat d’emmagatzematge de calor de les mostres de PCM estabilitzades amb diferents concentracions de gels polimèrics es determinen amb DCS i amb el mètode T-history.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study presents the findings of applying a Discrete Demand Side Control (DDSC) approach to the space heating of two case study buildings. High and low tolerance scenarios are implemented on the space heating controller to assess the impact of DDSC upon buildings with different thermal capacitances, light-weight and heavy-weight construction. Space heating is provided by an electric heat pump powered from a wind turbine, with a back-up electrical network connection in the event of insufficient wind being available when a demand occurs. Findings highlight that thermal comfort is maintained within an acceptable range while the DDSC controller maintains the demand/supply balance. Whilst it is noted that energy demand increases slightly, as this is mostly supplied from the wind turbine, this is of little significance and hence a reduction in operating costs and carbon emissions is still attained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There are varieties of physical and behavioral factors to determine energy demand load profile. The attainment of the optimum mix of measures and renewable energy system deployment requires a simple method suitable for using at the early design stage. A simple method of formulating load profile (SMLP) for UK domestic buildings has been presented in this paper. Domestic space heating load profile for different types of houses have been produced using thermal dynamic model which has been developed using thermal resistant network method. The daily breakdown energy demand load profile of appliance, domestic hot water and space heating can be predicted using this method. The method can produce daily load profile from individual house to urban community. It is suitable to be used at Renewable energy system strategic design stage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Extreme weather events, including heatwaves, are predicted to increase in both frequency and severity over the coming decades. Low house building rates and a growing population mean there is a need to adapt existing dwellings. Research presented here uses dynamic thermal simulation to model the effect of passive heatwave mitigating interventions for UK dwellings. Interventions include a range of additions and modifications to solar shading, insulation and ventilation. Results are presented for typical end and mid terrace houses, with four orientations, two occupancy profiles and using weather data from the 2003 heatwave. Results show the effectiveness of interventions that reduce solar gains through the building fabric, such as external wall insulation and solar reflective coatings. Internal wall insulation is shown to be less effective and can increase the overheating problem in some cases. Control of solar gains through glazing, using shutters and fixed shading, are also effective, particularly for south, east and west-facing rooms. Results are also presented which demonstrate how it is possible to select combinations of interventions that both eliminate overheating and reduce space heating energy use. The cost of interventions is also considered in the final analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A ground source heat pump assisted by an array of photovoltaic (PV)-thermal modules was studied in this work. Extracting heat from an array of PV modules should improve the performance of both the PV cells and the heat pump. A series of computer simulations compare the performance of a ground source heat pump with a short ground circuit, used to provide space heating and domestic hot water at a house in southern England. The results indicate that extracting heat from an array of PV-thermal modules would improve the performance of a ground source heat pump with an undersized ground loop. Nevertheless, open air thermal collectors could be more effective, especially during winter. In one model more electricity was saved in ohmic heating than was generated by cooling the PV cells. Cooling the PV modules was found to increase their electrical output up to 4%, but much of the extra electricity was consumed by the cooling pumps.