996 resultados para Solid extraction
Resumo:
High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.
Screening of plants found in the State of Amazonas, Brazil for activity against Aedes aegypti larvae
Resumo:
Ethanol, methanol and water extracts representing mostly native plant species found in the Amazon region were prepared, respectively, by maceration, continuous liquid-solid extraction and infusion, followed by evaporation and freeze-drying. The freeze-dried extracts were tested for lethality toward Aedes aegypti larvae at test concentrations of 500 mg / mL. In general, methanol extracts exhibited the greatest larvicidal activity. The following 7 methanol extracts of (the parts of) the indicated plant species were the most active, resulting in 100% mortality in A. aegypti larvae: Tapura amazonica Poepp. (root), Piper aduncum L. (leaf and root), P. tuberculatum Jacq. (leaf, fruit and branch). and Simaba polyphylla (Cavalcante) W.W. Thomas (branch).
Resumo:
In the present study, different aerial parts from twelve Amazonian plant species found in the National Institute for Amazon Research's (INPA's) Adolpho Ducke Forest Reserve (in Manaus, Amazonas, Brazil) were collected. Separate portions of dried, ground plant materials were extracted with water (by infusion), methanol and chloroform (by continuous liquid-solid extraction) and solvents were removed first by rotary evaporation, and finally by freeze-drying which yielded a total of seventy-one freeze-dried extracts for evaluation. These extracts were evaluated initially at concentrations of 500 and 100 µg/mL for in vitro hemolytic activity and in vitro inhibition of platelet aggregation in human blood, respectively. Sixteen extracts (23 % of all extracts tested, 42 % of all plant species), representing the following plants: Chaunochiton kappleri (Olacaceae), Diclinanona calycina (Annonaceae), Paypayrola grandiflora (Violaceae), Pleurisanthes parviflora (Icacinaceae), Sarcaulus brasiliensis (Sapotaceae), exhibited significant inhibitory activity towards human platelet aggregation. A group of extracts with antiplatelet aggregation activity having no in vitro hemolytic activity has therefore been identified. Three extracts (4 %), all derived from Elaeoluma nuda (Sapotaceae), exhibited hemolytic activity. None of the plant species in this study has known use in traditional medicine. So, these data serve as a baseline or minimum of antiplatelet and hemolytic activities (and potential usefulness) of non-medicinal plants from the Amazon forest. Finally, in general, these are the first data on hemolytic and inhibitory activity on platelet aggregation for the genera which these plant species represent.
Resumo:
X-This work shows an alternative method to copper determination by X-Ray Fluorescence (XRF). Since copper concentration in natural waters is not enough to reach XRF detection limit, a liquid-solid preconcentration procedure was proposed. Glycerin was used to complex the metal increasing its adsorption on activated charcoal. The solid phase was used to XRF determination. Several parameters were evaluated, such as, the complexation pH, the charcoal adsorption limit and the glycerin concentration. The interferences are lead and bismuth and the sensitivities decreased in the order Cu2+, Bi3+ and Pb2+. The advantages of the method are its simplicity, low cost and low spectral interference.
Resumo:
This study concerns certain problems inherent to the determination of fat-soluble vitamins in food, from extraction methods to identification and quantification. The discussion involves the main official and unofficial extraction methods coupled with spectrophotometric and HPLC techniques in which vitamins samples are obtained through liquid-liquid-solid and liquid-liquid-solid-solid extraction, indispensable to the analytical separation of different chemical compounds with vitamin functions. A saponification stage, possibly coupled with supercritical fluid extraction appears to be mandatory in the determination of vitamins A and E in their alcoholic forms. Alternative identification and quantification procedures are outlined: biological and chemical assays, analytical separations by HPLC (normal and reversed-phase), UV detection (all fat-soluble vitamins) and fluorescence detection (retinoids and tocopherols). Automation from sample preparation to quantification stages increases the data acquisition rate.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
La acumulación de material sólido en embalses, cauces fluviales y en zonas marítimas hace que la extracción mecánica de estos materiales por medio de succión sea cada vez mas frecuente, por ello resulta importante estudiar el rendimiento de la succión de estos materiales analizando la forma de las boquillas y los parámetros del flujo incluyendo la bomba. Esta tesis estudia, mediante equipos experimentales, la eficacia de distintos dispositivos de extracción de sólidos (utilizando boquillas de diversas formas y bombas de velocidad variable). El dispositivo experimental ha sido desarrollado en el Laboratorio de Hidráulica de la E.T.S.I. de Caminos, C. y P. de la Universidad Politécnica de Madrid. Dicho dispositivo experimental incluye un lecho sumergido de distintos tipos de sedimentos, boquillas de extracción de sólidos y bomba de velocidad variable, así como un elemento de separación del agua y los sólidos extraídos. Los parámetros básicos analizados son el caudal líquido total bombeado, el caudal sólido extraído, diámetro de la tubería de succión, forma y sección de la boquilla extractora, así como los parámetros de velocidad y rendimiento en la bomba de velocidad variable. Los resultados de las medidas obtenidas en el dispositivo experimental han sido estudiados por medio del análisis dimensional y con métodos estadísticos. A partir de este estudio se ha desarrollado una nueva formulación, que relaciona el caudal sólido extraído con los diámetros de tubería y boquilla, caudal líquido bombeado y velocidad de giro de la bomba. Así mismo, desde el punto de vista práctico, se han analizado la influencia de la forma de la boquilla con la capacidad de extracción de sólidos a igualdad del resto de los parámetros, de forma que se puedan recomendar que forma de la boquilla es la más apropiada. The accumulation of solid material in reservoirs, river channels and sea areas causes the mechanical extraction of these materials by suction is becoming much more common, so it is important to study the performance of the suction of these materials analyzing the shape of the nozzles and flow parameters, including the pump. This thesis studies, using experimental equipment, the effectiveness of different solids removal devices (using nozzles of different shapes and variable speed pumps). The experimental device was developed at the Hydraulics Laboratory of the Civil University of the Polytechnic University of Madrid. The device included a submerged bed with different types of sediment solids, different removal nozzles and variable speed pump. It also includes a water separation element and the solids extracted. The key parameters analyzed are the total liquid volume pumped, the solid volume extracted, diameter of the suction pipe, a section of the nozzle and hood, and the parameters of speed and efficiency of the variable speed pump. The basic parameters analyzed are the total liquid volume pumped, the removed solid volume, the diameter of the suction pipe, the shape and cross-section of the nozzle, and the parameters of speed, efficiency and energy consumed by the variable speed pump. The measurements obtained on the experimental device have been studied with dimensional analysis and statistical methods. The outcome of this study is a new formulation, which relates the solid volume extracted with the pipe and nozzle diameters, the pumped liquid flow and the speed of the pump. Also, from a practical point of view, the influence of the shape of the nozzle was compared with the solid extraction capacity, keeping equal the rest of the parameters. So, a recommendation of the best shape of the nozzle can be given.
Resumo:
This work encompasses a direct and coherent strategy to synthesise a molecularly imprinted polymer (MIP) capable of extracting fluconazole from its sample. The MIP was successfully prepared from methacrylic acid (functional monomer), ethyleneglycoldimethacrylate (crosslinker) and acetonitrile (porogenic solvent) in the presence of fluconazole as the template molecule through a non-covalent approach. The non-imprinted polymer (NIP) was prepared following the same synthetic scheme, but in the absence of the template. The data obtained from scanning electronic microscopy, infrared spectroscopy, thermogravimetric and nitrogen Brunauer-Emmett-Teller plot helped to elucidate the structural as well as the morphological characteristics of the MIP and NIP. The application of MIP as a sorbent was demonstrated by packing it in solid phase extraction cartridges to extract fluconazole from commercial capsule samples through an offline analytical procedure. The quantification of fluconazole was accomplished through UPLC-MS, which resulted in LOD≤1.63×10(-10) mM. Furthermore, a high percentage recovery of 91±10% (n=9) was obtained. The ability of the MIP for selective recognition of fluconazole was evaluated by comparison with the structural analogues, miconazole, tioconazole and secnidazole, resulting in percentage recoveries of 51, 35 and 32%, respectively.
Resumo:
A novel solid phase extraction technique is described where DNA is bound and eluted from magnetic silica beads in a manner where efficiency is dependent on the magnetic manipulation of the beads and not on the flow of solution through a packed bed. The utility of this technique in the isolation of reasonably pure, PCR-amplifiable DNA from complex samples is shown by isolating DNA from whole human blood, and subsequently amplifying a fragment of the beta-globin gene. By effectively controlling the movement of the solid phase in the presence of a static sample, the issues associated with reproducibly packing a solid phase in a microchannel and maintaining consistent flow rates are eliminated. The technique described here is rapid, simple, and efficient, allowing for recovery of more than 60% of DNA from 0.6 mu L of blood at a concentration which is suitable for PCR amplification. In addition, the technique presented here requires inexpensive, common laboratory equipment, making it easily adopted for both clinical point-of-care applications and on-site forensic sample analysis.
Resumo:
This communication describes an improved one-step solid-phase extraction method for the recovery of morphine (M), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G) from human plasma with reduced coextraction of endogenous plasma constituents, compared to that of the authors' previously reported method. The magnitude of the peak caused by endogenous plasma components in the chromatogram that eluted immediately before the retention time of M3G has been reduced (similar to 80%) significantly (p < 0.01) while achieving high extraction efficiencies for the compounds of interest, viz morphine, M6G, and M3G (93.8 +/- 2.5, 91.7 +/- 1.7, and 93.1 +/- 2.2%, respectively). Furthermore, when the improved solid-phase extraction method was used, the extraction cartridge-derived late-eluting peak (retention time 90 to 100 minutes) reported in our previous method, was no longer present in the plasma extracts. Therefore the combined effect of reducing the recovery of the endogenous components of plasma that chromatographed just before the retention time of M3G and the removal of the late-eluting, extraction cartridge-derived peak has resulted in a decrease in the chromatographic run-time to 20 minutes, thereby increasing the sample throughput by up to 100%.
Resumo:
A sensitive and reproducible solid-phase extraction (SPE) method for the quantification of oxycodone in human plasma was developed. Varian Certify SPE cartridges containing both C-8 and benzoic acid functional groups were the most suitable for the extraction of oxycodone and codeine (internal standard), with consistently high (greater than or equal to 80%) and reproducible recoveries. The elution mobile phase consisted of 1.2 ml of butyl chloride-isopropanol (80:20, v/v) containing 2% ammonia. The quantification limit for oxycodone was 5.3 pmol on-column. Within-day and inter-day coefficients of variation were 1.2% and 6.8% respectively for 284 nM oxycodone and 9.5% and 6.2% respectively for 28.4 nM oxycodone using 0.5-ml plasma aliquots. (C) 1998 Elsevier Science BN. All rights reserved.
Resumo:
QuEChERS original method was modified into a new version for pesticides determination in soils. The QuEChERS method is based on liquid–liquid portioning with ACN and was followed by cleanup step using dispersive SPE and disposable pipette tips. Gas chromatographic separation with MS detection was carried out for pesticides quantification. The method was validated using recovery experiments for 36 multiclass pesticides. Mean recoveries of pesticides at each of the four spiking levels between 10–300 µg/kg of soil ranged from 70–120% for 26 pesticides with RSD values less than 15%. The method achieved low limit of detection less than 7.6 µ g/kg. Matrix effects were observed for 13 pesticides. Matrix effects were compensated by using matrix-matched calibration. The method was applied successfully using d-SPE or DPX in the analysis of the pesticides in soils from organic farming and integrated pest management.
Resumo:
In this study, we sought to assess the applicability of GC–MS/MS for the identification and quantification of 36 pesticides in strawberry from integrated pest management (IPM) and organic farming (OF). Citrate versions of QuEChERS (quick, easy, cheap, effective, rugged and safe) using dispersive solid-phase extraction (d-SPE) and disposable pipette extraction (DPX) for cleanup were compared for pesticide extraction. For cleanup, a combination of MgSO4, primary secondary amine and C18 was used for both the versions. Significant differences were observed in recovery results between the two sample preparation versions (DPX and d-SPE). Overall, 86% of the pesticides achieved recoveries (three spiking levels 10, 50 and 200 µg/kg) in the range of 70–120%, with <13% RSD. The matrix effects were also evaluated in both the versions and in strawberries from different crop types. Although not evidencing significant differences between the two methodologies were observed, however, the DPX cleanup proved to be a faster technique and easy to execute. The results indicate that QuEChERS with d-SPE and DPX and GC–MS/MS analysis achieved reliable quantification and identification of 36 pesticide residues in strawberries from OF and IPM.
Resumo:
Solid-phase extraction (SPE) in tandem with dispersive liquid-liquid microextraction (DLLME) has been developed for the determination of mononitrotoluenes (MNTs) in several aquatic samples using gas chromatography-flame ionization (GC-FID) detection system. In the hyphenated SPE-DLLME, initially MNTs were extracted from a large volume of aqueous samples (100 mL) into a 500-mg octadecyl silane (C(18) ) sorbent. After the elution of analytes from the sorbent with acetonitrile, the obtained solution was put under the DLLME procedure, so that the extra preconcentration factors could be achieved. The parameters influencing the extraction efficiency such as breakthrough volume, type and volume of the elution solvent (disperser solvent) and extracting solvent, as well as the salt addition, were studied and optimized. The calibration curves were linear in the range of 0.5-500 μg/L and the limit of detection for all analytes was found to be 0.2 μg/L. The relative standard deviations (for 0.75 μg/L of MNTs) without internal standard varied from 2.0 to 6.4% (n=5). The relative recoveries of the well, river and sea water samples, spiked at the concentration level of 0.75 μg/L of the analytes, were in the range of 85-118%.
Resumo:
Two concentration methods for fast and routine determination of caffeine (using HPLC-UV detection) in surface, and wastewater are evaluated. Both methods are based on solid-phase extraction (SPE) concentration with octadecyl silica sorbents. A common “offline” SPE procedure shows that quantitative recovery of caffeine is obtained with 2 mL of an elution mixture solvent methanol-water containing at least 60% methanol. The method detection limit is 0.1 μg L−1 when percolating 1 L samples through the cartridge. The development of an “online” SPE method based on a mini-SPE column, containing 100 mg of the same sorbent, directly connected to the HPLC system allows the method detection limit to be decreased to 10 ng L−1 with a sample volume of 100 mL. The “offline” SPE method is applied to the analysis of caffeine in wastewater samples, whereas the “on-line” method is used for analysis in natural waters from streams receiving significant water intakes from local wastewater treatment plants