980 resultados para Soft tissues


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To examine the effect of thermal agents on the range of movement (ROM) and mechanical properties in soft tissue and to discuss their clinical relevance. DATA SOURCES: Electronic databases (Cochrane Central Register of Controlled Trials, MEDLINE, and EMBASE) were searched from their earliest available record up to May 2011 using Medical Subjects Headings and key words. We also undertook related articles searches and read reference lists of all incoming articles. STUDY SELECTION: Studies involving human participants describing the effects of thermal interventions on ROM and/or mechanical properties in soft tissue. Two reviewers independently screened studies against eligibility criteria. DATA EXTRACTION: Data were extracted independently by 2 review authors using a customized form. Methodologic quality was also assessed by 2 authors independently, using the Cochrane risk of bias tool. DATA SYNTHESIS: Thirty-six studies, comprising a total of 1301 healthy participants, satisfied the inclusion criteria. There was a high risk of bias across all studies. Meta-analyses were not undertaken because of clinical heterogeneity; however, effect sizes were calculated. There were conflicting data on the effect of cold on joint ROM, accessory joint movement, and passive stiffness. There was limited evidence to determine whether acute cold applications enhance the effects of stretching, and further evidence is required. There was evidence that heat increases ROM, and a combination of heat and stretching is more effective than stretching alone. CONCLUSIONS: Heat is an effective adjunct to developmental and therapeutic stretching techniques and should be the treatment of choice for enhancing ROM in a clinical or sporting setting. The effects of heat or ice on other important mechanical properties (eg, passive stiffness) remain equivocal and should be the focus of future study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tissue engineering and cell implantation therapies are gaining popularity because of their potential to repair and regenerate tissues and organs. To investigate the role of inflammatory cytokines in new tissue development in engineered tissues, we have characterized the nature and timing of cell populations forming new adipose tissue in a mouse tissue engineering chamber (TEC) and characterized the gene and protein expression of cytokines in the newly developing tissues. EGFP-labeled bone marrow transplant mice and MacGreen mice were implanted with TEC for periods ranging from 0.5 days to 6 weeks. Tissues were collected at various time points and assessed for cytokine expression through ELISA and mRNA analysis or labeled for specific cell populations in the TEC. Macrophage-derived factors, such as monocyte chemotactic protein-1 (MCP-1), appear to induce adipogenesis by recruiting macrophages and bone marrow-derived precursor cells to the TEC at early time points, with a second wave of nonbone marrow-derived progenitors. Gene expression analysis suggests that TNFα, LCN-2, and Interleukin 1β are important in early stages of neo-adipogenesis. Increasing platelet-derived growth factor and vascular endothelial cell growth factor expression at early time points correlates with preadipocyte proliferation and induction of angiogenesis. This study provides new information about key elements that are involved in early development of new adipose tissue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental observations of the time-dependent mechanical responses of collagenous tissues have demonstrated behavior that deviates from standard treatments of linear or quasi-linear viscoelasticity. In particular, time-dependent deformation can be strongly coupled to strain level, and strain-rate independence can be observed under monotonic loading, even for a tissue with dramatic stress relaxation. It was postulated that this nonlinearity is fundamentally associated with gradual recruitment of individual collagen fibrils during applied mechanical loading. Based on previously observed experimental results for the time-dependent response of collagenous soft tissues, a model is developed to describe the mechanical behavior of these tissues under uniaxial loading. Tissue stresses, under applied strain-controlled loading, are assumed to be a sum of elastic and viscoelastic stress contributions. The relative contributions of elastic and viscoelastic stresses is assumed to vary with strain level, leading to strain- and time-dependent mechanical behavior. The model formulation is examined under conditions of monotonic loading at varying constant strain rates and stress-relaxation at different applied strain levels. The model is compared with experimental data for a membranous biological soft tissue, the amniotic sac, and is found to agree well with experimental results. The limiting behavior of the novel model, at large strains relative to the collagen recruitment, is consistent with the quasi-linear viscoelastic approach. © 2006 Materials Research Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The biological response following subcutaneous and bone implantation of beta-wollastonite(beta-W)-doped alpha-tricalcium phosphate bioceramics in rats was evaluated. Tested materials were: tricalciurn phosphate (TCP), consisting of a mixture of alpha- and beta-polymorphs; TCP doped with 5 wt. % of beta-W (TCP5W), composed of alpha-TCP as only crystalline phase; and TCP doped with 15 wt. % of beta-W (TCP15), containing crystalline alpha-TCP and beta-W. Cylinders of 2x1 mm were implanted in tibiae and backs of adult male Rattus norvegicus, Holtzman rats. After 7, 30 and 120 days, animals were sacrificed and the tissue blocks containing the implants were excised, fixed and processed for histological examination. TCP, TCP5W and TCP15W implants were biocompatible but neither bioactive nor biodegradable in rat subcutaneous tissue. They were not osteoinductive in connective tissue either. However, in rat bone tissue beta-W-doped alpha-TCP implants (TCP5W and TCP15W) were bioactive, biodegradable and osteoconductive. The rates of biodegradation and new bone formation observed for TCP5W and TCP15W implants in rat bone tissue were greater than for non-doped TCP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To study the influence on the healing of soft and hard peri-implant tissues when implants of different sizes and configurations were installed into sockets immediately after tooth extraction.Material and methods: Transmucosal cylindrical implants, 3.3 mm in diameter in the control sites, and conical 5 mm in diameter in the test sites, were installed into the distal socket of the fourth mandibular premolars in dogs immediately after tooth extraction. After 4 months, the hard and soft tissue healing was evaluated histologically. Results: All implants were integrated in mineralized mature bone. Both at the test and control sites, the alveolar crest underwent resorption. The buccal bony surface at the implant test sites (conical; 3.8 mm) was more resorbed compared with the control sites (cylindrical; 1.6 mm). The soft tissue dimensions were similar in both groups. However, in relation to the implant shoulder, the peri-implant mucosa was located more apically at the test compared with the control sites.Conclusion: The present study confirmed that the distance between the implant surface and the outer contour of the buccal alveolar bony crest influenced the degree of resorption of the buccal bone plate. Consequently, in relation to the implant shoulder, the peri-implant mucosa will be established at a more apical level, if the distance between the implant surface and the outer contour of the alveolar crest is small.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The biological response following subcutaneous and bone implantation of β-wollastonite(β-W)-doped α-tricalcium phosphate bioceramics in rats was evaluated. Tested materials were: tricalcium phosphate (TCP), consisting of a mixture of α- and β-polymorphs; TCP doped with 5 wt. % of β-W (TCP5W), composed of α-TCP as only crystalline phase; and TCP doped with 15 wt. % of β-W (TCP 15), containing crystalline α-TCP and β-W. Cylinders of 2×1 mm were implanted in tibiae and backs of adult male Rattus norvegicus, Holtzman rats. After 7, 30 and 120 days, animals were sacrificed and the tissue blocks containing the implants were excised, fixed and processed for histological examination. TCP, TCP5W and TCP15W implants were biocompatible but neither bioactive nor biodegradable in rat subcutaneous tissue. They were not osteoinductive in connective tissue either. However, in rat bone tissue β-W-doped α-TCP implants (TCP5W and TCP 15W) were bioactive, biodegradable and osteoconductive. The rates of biodegradation and new bone formation observed for TCP5W and TCP15W implants in rat bone tissue were greater than for non-doped TCP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To evaluate the influence of the width of the buccal bony wall on hard and soft tissue dimensions following implant installation. Material and methods: Mandibular premolars and first molars of six Labrador dogs were extracted bilaterally. After 3 months of healing, two recipient sites, one on each side of the mandible, were prepared in such a way as to obtain a buccal bony ridge width of about 2 mm in the right (control) and 1 mm in the left sides (test), respectively. Implants were installed with the coronal margin flush with the buccal alveolar bony crest. Abutments were placed and the flaps were sutured to allow a non-submerged healing. After 3 months, the animals were euthanized and ground sections obtained. Results: All implants were completely osseointegrated. In respect to the coronal rough margin of the implant, the most coronal bone-to-implant contact was apically located 1.04 ± 0.91 and 0.94 ± 0.87 mm at the test and control sites, respectively, whereas the top of the bony crest was located 0.30 ± 0.40 mm at the test and 0.57 ± 0.49 mm at the control sites. No statistically significant differences were found. A larger horizontal bone resorption, however, evaluated 1 mm apically to the rough margin, was found at the control (1.1 ± 0.7 mm) compared to the test (0.3 ± 0.3 mm) sites, the difference being statistically significant. A thin peri-implant mucosa (2.4-2.6 mm) was found at implant installation while, after 3 months of healing, a biological width of 3.90-4.40 mm was observed with no statistically significant differences between control and test sites. Conclusions: A width of the buccal bony wall of 1or 2 mm at implant sites yielded similar results after 3 months of healing in relation of hard tissue and soft tissues dimensions after implant installation. © 2012 John Wiley & Sons A/S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ObjectiveTo study the buccal dimensional tissue changes at oral implants following free gingival grafting, with or without including the keratin layer, performed at the time of implant installation into alveolar mucosa.Material and methodsThe mandibular premolars and first molars were extracted bilaterally in six Beagle dogs. In the right side of the mandible (Test), flaps were first elevated, and the buccal as well as part of the lingual masticatory mucosa was removed. An incision of the periosteum at the buccal aspect was performed to allow the flap to be coronally repositioned. Primary wound closure was obtained. In the left side, the masticatory (keratinized) mucosa was left in situ, and no sutures were applied (Control). After 3months of healing, absence of keratinized mucosa was confirmed at the test sites. Two recipient sites were prepared at each side of the mandible in the region of the third and fourth premolars. All implants were installed with the shoulder placed flush with the buccal alveolar bony crest, and abutments were connected to allow a non-submerged healing. Two free gingival mucosal grafts were harvested from the buccal region of the maxillary canines. One graft was left intact (gingival mucosal graft), while for the second, the epithelial layer was removed (gingival connective tissue graft). Subsequently, the grafts were fixed around the test implants in position of the third and fourth premolars, respectively. After 3months, the animals were euthanized and ground sections obtained.ResultsSimilar bony crest resorption and coronal extension of osseointegration were found at test and control sites. Moreover, similar dimensions of the peri-implant soft tissues were obtained at test and control sites.ConclusionsThe increase in the alveolar mucosal thickness by means of a gingival graft affected the peri-implant marginal bone resorption and soft tissue recession around implants. This resulted in outcomes that were similar to those at implants surrounded by masticatory mucosa, indicating that gingival grafting in the absence of keratinized mucosa around implants may reduce the resorption of the marginal crest and soft tissue recession.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. Metallic abutments can provide grayish color when in contact with thin soft tissues which may lead the implant prosthetic treatment to failure. In this context, the abutments of zirconia stand out because there is an excellent linking between esthetics and the health of peri-implant soft tissues. A consult of the published researches was made on the PubMed database from 2000 to September 2012. The including criteria were: literature reviews, clinical studies and case reports in English that focused on the response of the soft tissue in contact with zirconia implant abutments. The studies that were not in English and did not match the tackled issue were excluded. A total of 32 articles were found. According to the search strategy, just 16 articles were selected for this review. Three studies affirmed that zirconia abutments have an excellent soft tissue response; one study showed increased gingival recession with zirconia abutments and nine studies do not stand out any difference on biological behavior between titanium and zirconia abutments. Three studies affirmed that zirconia abutments provide natural gingival appearance, anatomic contour and greater esthetics. The use of zirconia abutments is recommended for anterior regions because of their greater optical properties and esthetic results and more studies should be performed and analyzed longitudinally regarding their biological response. The zirconia abutments have been established to be essential in order to achieve great esthetic results in cases of thin peri-implant soft tissues and in regions where the three-dimensional placement of implants is more superficial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il crescente utilizzo di sistemi di analisi high-throughput per lo studio dello stato fisiologico e metabolico del corpo, ha evidenziato che una corretta alimentazione e una buona forma fisica siano fattori chiave per la salute. L'aumento dell'età media della popolazione evidenzia l'importanza delle strategie di contrasto delle patologie legate all'invecchiamento. Una dieta sana è il primo mezzo di prevenzione per molte patologie, pertanto capire come il cibo influisce sul corpo umano è di fondamentale importanza. In questo lavoro di tesi abbiamo affrontato la caratterizzazione dei sistemi di imaging radiografico Dual-energy X-ray Absorptiometry (DXA). Dopo aver stabilito una metodologia adatta per l'elaborazione di dati DXA su un gruppo di soggetti sani non obesi, la PCA ha evidenziato alcune proprietà emergenti dall'interpretazione delle componenti principali in termini delle variabili di composizione corporea restituite dalla DXA. Le prime componenti sono associabili ad indici macroscopici di descrizione corporea (come BMI e WHR). Queste componenti sono sorprendentemente stabili al variare dello status dei soggetti in età, sesso e nazionalità. Dati di analisi metabolica, ottenuti tramite Magnetic Resonance Spectroscopy (MRS) su campioni di urina, sono disponibili per circa mille anziani (provenienti da cinque paesi europei) di età compresa tra i 65 ed i 79 anni, non affetti da patologie gravi. I dati di composizione corporea sono altresì presenti per questi soggetti. L'algoritmo di Non-negative Matrix Factorization (NMF) è stato utilizzato per esprimere gli spettri MRS come combinazione di fattori di base interpretabili come singoli metaboliti. I fattori trovati sono stabili, quindi spettri metabolici di soggetti sono composti dallo stesso pattern di metaboliti indipendentemente dalla nazionalità. Attraverso un'analisi a singolo cieco sono stati trovati alti valori di correlazione tra le variabili di composizione corporea e lo stato metabolico dei soggetti. Ciò suggerisce la possibilità di derivare la composizione corporea dei soggetti a partire dal loro stato metabolico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the influence of flap tension on the tearing characteristics of mucosal tissue samples in relation to various suture and needle characteristics. MATERIAL AND METHODS: Lining and masticatory mucosal tissue samples obtained from pig jaws were prepared for in vitro testing. Tension tearing diagrams of 60 experiments were traced for 3-0, 5-0 and 7-0 sutures with applied forces up to 20 N. In the second part, the same experiments were repeated with 100 diagrams to test the influence of needle characteristics with 5-0 and 6-0 sutures using only gingival tissue samples. RESULTS: 3-0 sutures mainly lead to tissue breakage at an average of 13.4 N. In contrast, 7-0 sutures only resulted in breakage of the thread at a mean applied force of 3.7 N. With 5-0 sutures, both events occurred at random at a mean force of 14.6 N. Irrespective of the needle characteristics, the mean breaking force for gingival samples with 5-0 and 6-0 sutures was approximately 10 N. CONCLUSIONS: Tissue trauma may be reduced by choosing finer suture diameters, because thinner (6-0, 7-0) sutures lead to thread breakage rather than tissue breakage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To assess soft tissues healing at immediate transmucosal implants placed into molar extraction sites with buccal self-contained dehiscences. MATERIAL AND METHODS: For this 12-month controlled clinical trial, 15 subjects received immediate transmucosal tapered-effect (TE) implants placed in molar extraction sockets displaying a buccal bone dehiscence (test sites) with a height and a width of > or =3 mm, respectively. Peri-implant marginal defects were treated according to the principles of Guided Bone Regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresorbable collagen membrane. Fifteen subjects received implants in healed molar sites (control sites) with intact buccal alveolar walls following tooth extraction. In total, 30 TE implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were used. Flaps were repositioned and sutured, allowing non-submerged, transmucosal soft tissues healing. At the 12-month follow-up, pocket probing depths (PPD) and clinical attachment levels (CAL) were compared between implants placed in the test and the control sites, respectively. RESULTS: All subjects completed the 12-month follow-up period. All implants healed uneventfully, yielding a survival rate of 100%. After 12 months, statistically significantly higher (P<0.05) PPD and CAL values were recorded around implants placed in the test sites compared with those placed in the control sites. CONCLUSIONS: The findings of this controlled clinical trial showed that healing following immediate transmucosal implant installation in molar extraction sites with wide and shallow buccal dehiscences yielded less favorable outcomes compared with those of implants placed in healed sites, and resulted in lack of 'complete' osseointegration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Current guidelines for evaluating cleft palate treatments are mostly based on two-dimensional (2D) evaluation, but three-dimensional (3D) imaging methods to assess treatment outcome are steadily rising. OBJECTIVE To identify 3D imaging methods for quantitative assessment of soft tissue and skeletal morphology in patients with cleft lip and palate. DATA SOURCES Literature was searched using PubMed (1948-2012), EMBASE (1980-2012), Scopus (2004-2012), Web of Science (1945-2012), and the Cochrane Library. The last search was performed September 30, 2012. Reference lists were hand searched for potentially eligible studies. There was no language restriction. STUDY SELECTION We included publications using 3D imaging techniques to assess facial soft tissue or skeletal morphology in patients older than 5 years with a cleft lip with/or without cleft palate. We reviewed studies involving the facial region when at least 10 subjects in the sample size had at least one cleft type. Only primary publications were included. DATA EXTRACTION Independent extraction of data and quality assessments were performed by two observers. RESULTS Five hundred full text publications were retrieved, 144 met the inclusion criteria, with 63 high quality studies. There were differences in study designs, topics studied, patient characteristics, and success measurements; therefore, only a systematic review could be conducted. Main 3D-techniques that are used in cleft lip and palate patients are CT, CBCT, MRI, stereophotogrammetry, and laser surface scanning. These techniques are mainly used for soft tissue analysis, evaluation of bone grafting, and changes in the craniofacial skeleton. Digital dental casts are used to evaluate treatment and changes over time. CONCLUSION Available evidence implies that 3D imaging methods can be used for documentation of CLP patients. No data are available yet showing that 3D methods are more informative than conventional 2D methods. Further research is warranted to elucidate it.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To date, there is no systematic investigation of the association of short tandem repeat (STR) typing success rate in soft tissues with different signs of putrefaction. Herein, putrefaction was rated using a newly developed 19-parameter system in soft tissues from a collective of 68 decaying bodies, and DNA yield was determined in 408 samples. DNA integrity was rated using a self-devised pentaplex PCR generating an "integrity score" (Si ). STR typing success rate was then assessed for selected cases. DNA yield and Si differed significantly between tissues with kidney on average exhibiting the highest Si values. Statistical analysis revealed that nine parameters were significantly and positively correlated with Si . The observed values for each of these nine parameters were summed up to generate a putrefaction score (Sp ) for each sample. Our results show that STR typing success rate can be predicted based on Sp before expensive multiplex STR profiling is performed.