957 resultados para Sludge treatment wetland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This cooperation project aims to improve the sanitation facilities of the city of Wukro (located in the Tigray Region, northern Ethiopia), particularly the management of latrine wastes, by designing a sludge treatment plant in the city. It is framed within the Final Project Department of the E.T.S.I. de Caminos, Canales y Puertos, in collaboration with Wukro’s St. Mary’s College and the Mission of Ángel Olaran, that are part of the Ethiopian Catholic Church Diocese of Adigrat (ECCA). The present city, of about 42,000 inhabitants, was founded by the Italians in 1936. Due to its geographic location, which makes the city suitable for industrial and agricultural activities, Wukro is becoming an important administrative and economic center in the region, with a fast growing population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is an Inter-Disciplinary Higher Degree (IHD) thesis about Water Pollution Control in the Iron and Steel Industry. After examining the compositions, and various treatment methods, for the major effluent streams from a typical Integrated Iron and Steel works, it was decided to concentrate investigative work on the activated-sludge treatment of coke-oven effluents. A mathematical model of this process was developed in an attempt to provide a tool for plant management that would enable improved performance, and enhanced control of Works Units. The model differs from conventional models in that allowance is made for the presence of two genera of microorganisms, each of which utilises a particular type of substrate as its energy source. Allowance is also made for the inhibitive effect of phenol on thiocyanate biodegradation, and for the self-toxicity of the bacteria when present in a high substrate concentration environment. The enumeration of the kinetic characteristics of the two groups of micro-organisms was shown to be of major importance. Laboratory experiments were instigated in an attempt to determine accurate values of these coefficients. The use of the Suspended Solids concentration was found to be too insensitive a measure of viable active mass. Other measures were investigated, and Adenosine Triphosphate concentration was chosen as the most effective measure of bacterial populations. Using this measure, a model was developed for phenol biodegradation from experimental results which implicated the possibility of storage of substate prior to metabolism. A model for thiocyanate biodegradation was also developed, although the experimental results indicate that much work is still required in this area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A combination of experimental methods was applied at a clogged, horizontal subsurface flow (HSSF) municipal wastewater tertiary treatment wetland (TW) in the UK, to quantify the extent of surface and subsurface clogging which had resulted in undesirable surface flow. The three dimensional hydraulic conductivity profile was determined, using a purpose made device which recreates the constant head permeameter test in-situ. The hydrodynamic pathways were investigated by performing dye tracing tests with Rhodamine WT and a novel multi-channel, data-logging, flow through Fluorimeter which allows synchronous measurements to be taken from a matrix of sampling points. Hydraulic conductivity varied in all planes, with the lowest measurement of 0.1 md1 corresponding to the surface layer at the inlet, and the maximum measurement of 1550 md1 located at a 0.4m depth at the outlet. According to dye tracing results, the region where the overland flow ceased received five times the average flow, which then vertically short-circuited below the rhizosphere. The tracer break-through curve obtained from the outlet showed that this preferential flow-path accounted for approximately 80% of the flow overall and arrived 8 h before a distinctly separate secondary flow-path. The overall volumetric efficiencyof the clogged system was 71% and the hydrology was simulated using a dual-path, dead-zone storage model. It is concluded that uneven inlet distribution, continuous surface loading and high rhizosphere resistance is responsible for the clog formation observed in this system. The average inlet hydraulic conductivity was 2 md1, suggesting that current European design guidelines, which predict that the system will reach an equilibrium hydraulic conductivity of 86 md1, do not adequately describe the hydrology of mature systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cette thèse a été codirigée par le Dr. Florent Chazarenc

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of different stages of sewage sludge treatment on phosphorus (P) dynamics in amended soils was determined using samples of undigested liquid (UL), anaerobically digested liquid (AD) and dewatered anaerobically digested (DC) sludge. Sludges were taken from three points in the same treatment stream and applied to a sandy loam soil in field-based mesocosms at 4, 8 and 16t ha−1 dry solids. Mesocosms were sown with perennial ryegrass (Lolium perenne cv. Melle), and the sward was harvested after 35 and 70 days to determine yield and foliar P concentration. Soils were also sampled during this period to measure P transformations and the activities of acid phosphomonoesterase and phosphodiesterase. Data show that the AD amended soils had the greatest plant-available and foliar P content up to the second harvest, but the UL amended soils had the greatest enzyme activity. Characterisation of control and 16t ha−1 soils and sludge using solution 31P nuclear magnetic resonance (NMR) spectroscopy after NaOH–EDTA extraction revealed that P was predominantly in the inorganic pool in all three sludge samples, with the highest proportion (of the total extracted P) as inorganic P in the anaerobically digested liquid sludge. After sludge incorporation, P was immobilised to organic species. The majority of organic P was in monoester-P forms, while the remainder of organic P (diester P and phosphonate P) was more susceptible to transformations through time and showed variation with sludge type. These results show that application of sewage sludge at rates as low as 4t ha−1 can have a significant nutritional benefit to ryegrass over an initial 35-day growth and subsequent 35-day re-growth periods. Differences in P transformation, and hence nutritional benefit, between sludge types were evident throughout the experiment. Thus, differences in sludge treatment process alter the edaphic mineralisation characteristics of biosolids derived from the same source material.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Poster presentado 12th Symposium on Aquatic Microbial Ecology (SAME12) August 28 – September 02, 2011 Germany , Rostock–Warnemünde

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Half of the world’s urban population will live in informal settlements or “slums” by 2030. Affordable urban sanitation presents a unique set of challenges as the lack of space and resources to construct new latrines makes the de-sludging of existing pits necessary and is something that is currently done manually with significant associated health risks. Therefore various mechanised technologies have been developed to facilitate pit emptying, with the majority using a vacuum system to remove material from the top of the pit. However, this results in the gradual accumulation of unpumpable sludge in the pit, which eventually fills the latrine and forces it to be abandoned. This study has developed a method for fluidising unpumpable pit latrine sludge, based on laboratory experiments using a harmless synthetic sludge. Such a sludge consisting of clay and compost was developed to replicate the physical characteristics of pit latrine sludges characterised in Botswana during the 1980s. Undrained shear strength and density are identified as the critical parameters in controlling pumpability and a method of sludge characterisation based on these parameters is reported. In a series of fluidisation tests using a one fifth scale pit emptying device the reduction in sludge shear strength was found to be caused by i) dilution, which increases water content, and ii) remoulding, which involves mechanical agitation to break down the structure of the material. The tests demonstrated that even the strongest of sludges could be rendered “pumpable” by sufficient dilution. Additionally, air injection alone produced a three-fold decrease in strength of consolidated samples as a result of remoulding at constant water content. The implications for sludge treatment and disposal are discussed, and the classification of sludges according to the equipment required to remove them from the latrine is proposed. Possible field tests to estimate sludge density and shear strength are suggested. The feasibility of using low cost vacuum cleaners to replace expensive vane pumps is demonstrated. This offers great potential for the development of affordable pit emptying technologies that can remove significantly stronger sludges than current devices through fluidising the wastes at the bottom of the pit before emptying

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Half of the world's urban population will live in informal settlements or ‘slums’ by 2030. Affordable urban sanitation presents a unique set of challenges as the lack of space and resources to construct new latrines makes the de-sludging of existing pits necessary and is something that is currently done manually with significant associated health risks. Various mechanised technologies have therefore been developed to facilitate pit emptying, with the majority using a vacuum system to remove material from the top of the pit. However, this results in the gradual accumulation of unpumpable sludge at the bottom of the pit, which eventually fills the latrine and forces it to be abandoned. This study has developed a method for fluidising unpumpable pit latrine sludge, based on laboratory experiments using a harmless synthetic sludge. The implications for sludge treatment and disposal are discussed, and the classification of sludges according to the equipment required to remove them from the latrine is proposed. Finally, further work is suggested, including the ongoing development of a device to physically characterise latrine sludge in-situ within the pit.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Wetlands systems are considered nowadays as a treatment method that uses simple, easy operation and low cost technology, which has been used in various parts of the world and also in Brazil. Used alone or as a complement to other types of treatment systems, once it effectively removes nutrients, pathogens and other pollutants in the water. Due to the high complexity found in wetlands, making it difficult to predict the response of the system to treat wastewater, one should consider as ideal to base the sizing of the wetland system over the necessary removal of this parameter instead of scaling it from empiricism. The study was conducted to determine the coefficient of bacterial decrease in the Wetland unit located at Ponta Negra Station Sewage Treatment, located in Natal, the coastal region of Rio Grande do Norte. The most representative model to determine the bacterial decrease in this system was the one from Chick for hydraulic piston system. Kb of 0.37 d-1 were found for the flow rate of 15m³/d, while for the system operating at maximum design flow, 30m³/d, the Kb of 0.98 d-1 was found

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The first studies with constructed wetlands undertaken in Brazil were the result of observations made from the Amazon flood plains. The first attempt to use this capacity to change the quality of the water, in the sense of purification performed in Brazil using constructed wetland systems, was made by Salati et al. After that, new technologies were developed in a focused attempt to increase the efficiency of the system and reduce investments. Over these 18 years, persuading the Brazilian scientific community as well as the environmental control agencies to give due attention to this kind of research has required endless efforts. Only in recent years have major institutions responsible for sewage treatment and potable water supply been concerned with this type of technology for solving real problems. These institutions are as follows: SABESP (Basic Sanitation Company of Sao Paulo State), SANEPAR (Sanitation Company of Parana State) and CESP (Electric Company of Sao Paulo State). One of the private institutions that has systematically worked in the design and projects of constructed wetlands is the Institute of Applied Ecology. This institution has enhanced and developed a water depuration system based on the purifying capacity of the soil. The wetlands with filtering soils are systems formed by overlapping layers of crushed stone, gravel and soil planted with rice. This technology has been used in sewage treatment and also in water supply systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The project is being conducted in the town of Analândia, São Paulo, Brazil. The constructed wetlands system for water supply consists of a channel with floating aquatic macrophytes, HDS system (Water Decontamination with Soil - Patent PI 850.3030), chlorinating system, filtering system and distribution. The project objectives include investigating the process variables to further optimize design and operation factors, evaluating the relation of nutrients and plants development, biomass production, shoot development, nutrient cycling and total and fecal coliforms removal, comparing the treatment efficiency among the seasons of the year; and moreover to compare the average values obtained between February and June 1998 (Salati et al., 1998) with the average obtained for the same parameters between March and June 2000. Studies have been developed in order to verify during one year the drinking quality of the water for the following parameters: turbidity, color, pH, dissolved oxygen, total of dissolved solids, COD, chloride, among others, according to the Ministry of Health's Regulation 36. This system of water supply projected to treat 15 L s-1 has been in continuous operation for 2 years, it was implemented with support of the National Environment Fund (FNMA), administered by the Center of Environmental Studies (CEA-UNESP), while the technical supervision and design were performed by the Institute of Applied Ecology. The actual research project is being supported by FAPESP.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper, we report on a field experiment being carried out in a Typic Eutrorthox. The experiment was initiated in the 1997-98 agricultural season as a randomized block design with four treatments (0, 5, 10, and 20 t ha -1) of sewage sludge and five replicates. Compound soil samples were obtained from 20 subsamples collected at depths of 0-0.1 and 0.1-0.2 m. Cu, Fe, Mn, and Zn concentrations were extracted with DTPA pH 7.3; 0.1 mol L -1 HCl, Mehlich-I, Mehlich-III, and 0.01 mol L-1 CaCl 2. Metal concentrations were determined via atomic absorption spectrometry. Diagnostic leaves and the whole above-ground portion of plants were collected to determine Cu, Fe, Mn, and Zn concentrations extracted by nitric-perchloric digestion and later determined via atomic absorption spectrometry. Sewage sludge application caused increases in the concentrations of soil Cu, Fe, and Mn in samples taken from the 0-0.1 m depth evaluated by the extractants Mehlich-I, Mehlich-III, 0.01 mol L-1 HCl and DTPA pH 7.3. None of the extractants provided efficient estimates of changes in Mn concentrations. The acid extractants extracted more Cu, Fe, Mn, and Zn than the saline and chelating solutions. The highest concentrations of Cu, Fe, and Zn were obtained with Mehlich-III, while the highest concentrations of Mn were obtained with HCl. We did not observe a correlation between the extractants and the concentrations of elements in the diagnostic leaves nor in the tissues of the whole maize plant (Zea mays L.). © 2013 Springer Science+Business Media Dordrecht.