998 resultados para Skin, Artificial


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The purpose of the present study was to compare the effectiveness of three burns dressings (TransCyte, a bio-engineered skin substitute; Biobrane; and Silvazine cream (silver sulphadiazine and 0.2% chlorhexidine)), in treating children with partial-thickness burns. The primary objective was to determine the days until greater than or equal to90% re-epithelialization. The secondary objectives were to evaluate the number of wounds requiring autografting and the number of dressing changes/local wound care required. Methods: Study wounds were identified on each patient and the patients were randomized to receive TransCyte or Biobrane or Silvazine. Assessment of study wound closure began at 2 days after treatment and continued at least every other day thereafter until the wounds re-epithelialized or were autografted. A laser Doppler imaging system was used as an adjunct to assessing the depth of the burn. Results: Thirty-three patients with 58 wound sites enrolled in the study (TransCyte, n = 20, Biobrane, n = 17; Silvazine, n = 21). Mean time to re-epithelialization was 7.5 days for TransCyte, 9.5 days for Biobrane, and 11.2 days for Silvazine. The number of wounds requiring autografting were 5/21 (24%) for Silvazine, 3/17 (17%) for Biobrane, and 1/20 (5%) for TransCyte. Conclusions: When used in partial-thickness burns in children, TransCyte promotes fastest re-epithelialization and required less overall dressings then Biobrane or Silvazine. Patients who received Silvazine or Biobrane require more autografting than those treated with TransCyte.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: In the field of Plastic Reconstructive Surgery the development of new innovative matrices for skin repair is in urgent need. The ideal biomaterial should promote attachment, proliferation and growth of cells. Additionally, it should degrade in an appropriate time period without releasing harmful substances, but not exert a pathological immune response. Spider dragline silk from Nephila spp meets these demands to a large extent. Methodology/Principal Findings: Native spider dragline silk, harvested directly out of Nephila spp spiders, was woven on steel frames. Constructs were sterilized and seeded with fibroblasts. After two weeks of cultivating single fibroblasts, keratinocytes were added to generate a bilayered skin model, consisting of dermis and epidermis equivalents. For the next three weeks, constructs in co-culture were lifted on an originally designed setup for air/liquid interface cultivation. After the culturing period, constructs were embedded in paraffin with an especially developed program for spidersilk to avoid supercontraction. Paraffin cross-sections were stained in Haematoxylin & Eosin (H&E) for microscopic analyses. Conclusion/Significance: Native spider dragline silk woven on steel frames provides a suitable matrix for 3 dimensional skin cell culturing. Both fibroblasts and keratinocytes cell lines adhere to the spider silk fibres and proliferate. Guided by the spider silk fibres, they sprout into the meshes and reach confluence in at most one week. A well-balanced, bilayered cocultivation in two continuously separated strata can be achieved by serum reduction, changing the medium conditions and the cultivation period at the air/liquid interphase. Therefore spider silk appears to be a promising biomaterial for the enhancement of skin regeneration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: In the current climate of medical education, there is an ever-increasing demand for and emphasis on simulation as both a teaching and training tool. The objective of our study was to compare the realism and practicality of a number of artificial blood products that could be used for high-fidelity simulation. Method: A literature and internet search was performed and 15 artificial blood products were identified from a variety of sources. One product was excluded due to its potential toxicity risks. Five observers, blinded to the products, performed two assessments on each product using an evaluation tool with 14 predefined criteria including color, consistency, clotting, and staining potential to manikin skin and clothing. Each criterion was rated using a five-point Likert scale. The products were left for 24 hours, both refrigerated and at room temperature, and then reassessed. Statistical analysis was performed to identify the most suitable products, and both inter- and intra-rater variability were examined. Results: Three products scored consistently well with all five assessors, with one product in particular scoring well in almost every criterion. This highest-rated product had a mean rating of 3.6 of 5.0 (95% posterior Interval 3.4-3.7). Inter-rater variability was minor with average ratings varying from 3.0 to 3.4 between the highest and lowest scorer. Intrarater variability was negligible with good agreement between first and second rating as per weighted kappa scores (K = 0.67). Conclusion: The most realistic and practical form of artificial blood identified was a commercial product called KD151 Flowing Blood Syrup. It was found to be not only realistic in appearance but practical in terms of storage and stain removal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is widely acknowledged that changes in intracellular calcium ion (Ca2+) concentration provide dynamic signals that control a plethora of cellular processes, including triggering and mediating host defence mechanisms. In this study, quantitative real-time PCR was used to analyse gene expression of 14 Ca2+ signalling proteins in skin obtained from high tick-resistant (HR) and low tick-resistant (LR) cattle following artificial challenge with cattle tick (Rhipicephalus (Boophilus) microplus). Up-regulation of numerous genes was observed in both HR and LR skin following tick challenge, however substantially higher transcription activation was found in HR tissue. The elevated expression in HR skin of specific Ca2+ signalling genes such as AHNAK, CASQ, IL2, NFAT2CIP and PLCG1 may be related to host resistance. Our data suggest that Ca2+ and its associated proteins might play an important role in host response to ticks and that further investigation is warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigated and characterised transdermal permeation of bioactive agents from a topically applied Arnica montana tincture. Permeation experiments conducted over 48 h used polydimethylsiloxane (silastic) and human epidermal membranes mounted in Franz-type diffusion cells with a methanol-water (50:50 v/v) receptor fluid. A commercially available tincture of A. montana L. derived from dried Spanish flower heads was a donor solution. Further donor solutions prepared from this stock tincture concentrated the tincture constituents 1, 2 and 10 fold and its sesquiterpene lactones 10 fold. Permeants were assayed using a high-performance liquid chromatography method. Five components permeated through silastic membranes providing peaks with relative retention factors to an internal standard (santonin) of 0.28, 1.18, 1.45, 1.98 and 2.76, respectively. No permeant was detected within 12 h of applying the Arnica tincture onto human epidermal membranes. However, after 12 h, the first two of these components were detected. These were shown by Zimmermann reagent reaction to be sesquiterpene lactones and liquid chromatography/diode array detection/mass spectrometry indicated that these two permeants were 11,13-dihydrohelenalin (DH) analogues (methacrylate and tiglate esters). The same two components were also detected within 3 h of topical application of the 10-fold concentrated tincture and the concentrated sesquiterpene lactone extract.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Octopus skin samples were tested under quasi-static and scissor cutting conditions to measure the in-plane material properties and fracture toughness. Samples from all eight arms of one octopus were tested statically to investigate how properties vary from arm to arm. Another nine octopus skins were measured to study the influence of body mass on skin properties. Influence of specimen location on skin mechanical properties was also studied. Material properties of skin, i.e. the Young's modulus, ultimate stress, failure strain and fracture toughness have been plotted against the position of skin along the length of arm or body. Statistical studies were carried out to help analyzing experimental data obtained. Results of this work will be used as guidelines for the design and development of artificial skins for an octopus-inspired robot.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to develop skin artefact for an octopus-inspired robot arm, which is designed to be able to elongate 60% of its original length, silicone rubber and knitted nylon sheet were selected to manufacture an artificial skin, due to their higher elastic strain and high flexibility. Tensile and scissors cutting tests were conducted to characterise the matrix and reinforcing materials and the skin artefact. Material properties of the individual and the composite materials were compared with the measured properties of real octopus skin presented in Part I. The Young’s modulus of the skin should be below 20 MPa and the elastic strain range should be over 60%. The fracture toughness should be at least 0.9 kJ·m−2. Tubes made of the skin artefact filled with liquid were tested to study volume change under deformation. Finite element analysis model was developed to simulate the material and arm structure under tensile loading. Results show that the skin artefact developed has similar mechanical properties as the real octopus skin and satisfies all the design specifications of the OCTOPUS robot.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to fabricate a biomimetic skin for an octopus inspired robot, a new process was developed based on mechanical properties measured from real octopus skin. Various knitted nylon textiles were tested and the one of 10-denier nylon was chosen as reinforcement. A combination of Ecoflex 0030 and 0010 silicone rubbers was used as matrix of the composite to obtain the right stiffness for the skin-analogue system. The open mould fabrication process developed allows air bubble to escape easily and the artificial skin produced was thin and waterproof. Material properties of the biomimetic skin were characterised using static tensile and instrumented scissors cutting tests. The Young’s moduli of the artificial skin are 0.08 MPa and 0.13 MPa in the longitudinal and transverse directions, which are much lower than those of the octopus skin. The strength and fracture toughness of the artificial skin, on the other hand are higher than those of real octopus skins. Conically-shaped skin prototypes to be used to cover the robotic arm unit were manufactured and tested. The biomimetic skin prototype was stiff enough to maintain it conical shape when filled with water. The driving force for elongation was reduced significantly compared with previous prototypes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Artificial skins exhibit different mechanical properties in compare to natural skins. This drawback makes physical interaction with artificial skins to be different from natural skin. Increasing the performance of the artificial skins for robotic hands and medical applications is addressed in the present paper. The idea is to add active controls within artificial skins in order to improve their dynamic or static behaviors. This directly results into more interactivity of the artificial skins. To achieve this goal, a piece-wise linear anisotropic model for artificial skins is derived. Then a model of matrix of capacitive MEMS actuators for the control purpose is coupled with the model of artificial skin. Next an active surface shaping control is applied through the control of the capacitive MEMS actuators which shapes the skin with zero error and in a desired time. A simulation study is presented to validate the idea of using MEMS actuator for active artificial skins. In the simulation, we actively control 128 capacitive micro actuators for an artificial fingertip. The fingertip provides the required shape in a required time which means the dynamics of the skin is improved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human eyes have a remarkable ability to recognize hundreds of colour shades, which has stimulated the use of colorants, especially for clothing, but toxicological studies have shown that some textile dyes can be hazardous to human health. Under conditions of intense perspiration, dyes can migrate from coloured clothes and penetrate into human skin. Garments made from cotton fabrics are the most common clothing in tropical countries, due to their high temperatures. Aiming to identify safe textile dyes for dyeing cotton fabrics, the genotoxicity [in vitro Comet assay with normal human dermal fibroblasts (NHDF), Tail Intensity] and mutagenicity [Salmonella/microsome preincubation assay (30 min), tester strains TA98, TA100, YG1041 and YG1042] of Reactive Blue 2 (RB2, CAS No. 12236-82-7, C.I. 61211) and Reactive Green 19 (RG19, CAS No. 61931-49-5, C.I. 205075) were evaluated both in the formulated form and as extracted from cotton fibres using different artificial sweats. Both the dyes could migrate from cotton fibres to sweat solutions, the sweat composition and pH being important factors during this extraction. However, the dye sweat solutions showed no genotoxic/mutagenic effects, whereas a weak mutagenic potential was detected by the Ames test for both dyes in their formulated form. These findings emphasize the relevance of textile dyes assessment under conditions that more closely resemble human exposure, in order to recognize any hazard. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Local hypoxia, as due to trauma, surgery, or arterial occlusive disease, may severely jeopardize the survival of the affected tissue and its wound-healing capacity. Initially developed to replace blood transfusions, artificial oxygen carriers have emerged as oxygen therapeutics in such conditions. The aim of this study was to target primary wound healing and survival in critically ischemic skin by the systemic application of left-shifted liposomal hemoglobin vesicles (HbVs). This was tested in bilateral, cranially based dorsal skin flaps in mice treated with a HbV solution with an oxygen affinity that was increased to a P(50) (partial oxygen tension at which the hemoglobin becomes 50% saturated with oxygen) of 9 mmHg. Twenty percent of the total blood volume of the HbV solution was injected immediately and 24 h after surgery. On the first postoperative day, oxygen saturation in the critically ischemic middle flap portions was increased from 23% (untreated control) to 39% in the HbV-treated animals (P < 0.05). Six days postoperatively, flap tissue survival was increased from 33% (control) to 57% (P < 0.01) and primary healing of the ischemic wound margins from 6.6 to 12.7 mm (P < 0.05) after HbV injection. In addition, higher capillary counts and endothelial nitric oxide synthase expression (both P < 0.01) were found in the immunostained flap tissue. We conclude that left-shifted HbVs may ameliorate the survival and primary wound healing in critically ischemic skin, possibly mediated by endothelial nitric oxide synthase-induced neovascularization.