976 resultados para Single Frequency Bioimpedance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple frequency bioelectrical impedance analysis (MFBIA) has previously been shown to provide accurate relative measures of lymphedema in the upper limb of patients (1). This paper reports the results of a three year prospective study to evaluate the efficacy of MFBIA to predict the early onset of lymphedema in patients following treatment for breast cancer. Bioelectrical impedance measurements and circumferential measurements of each upper limb were recorded in healthy control subjects (n=60) to determine the normal range of the ratio (dominant/non-dominant) of extracellular and total limb volumes respectively. Patients undergoing surgery for the treatment of breast cancer were recruited as the study group; MFBIA and circumferential measurements were recorded pre-surgery, one month post-surgery and then at two month intervals for 24 months. One hundred and two patients were recruited into the study. Twenty patients developed lymphedema in the 24 months follow up period of this study. In each of these 20 cases MFBIA predicted the onset of the condition up to 10 months before the condition could be clinically diagnosed. Estimates of the sensitivity and specificity were both approximately 100%. At the time of detection by MFBIA, only one of the patients returned a positive test result from the total limb volumes determined from the circumferential measures. These results confirmed the suitability of the MFBIA technique as a reliable diagnostic procedure for the early detection of lymphedema.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ionospheric effect is one of the major errors in GPS data processing over long baselines. As a dispersive medium, it is possible to compute its influence on the GPS signal with the ionosphere-free linear combination of L1 and L2 observables, requiring dual-frequency receivers. In the case of single-frequency receivers, ionospheric effects are either neglected or reduced by using a model. In this paper, an alternative for single-frequency users is proposed. It involves multiresolution analysis (MRA) using a wavelet analysis of the double-difference observations to remove the short- and medium-scale ionosphere variations and disturbances, as well as some minor tropospheric effects. Experiments were carried out over three baseline lengths from 50 to 450 km, and the results provided by the proposed method were better than those from dual-frequency receivers. The horizontal root mean square was of about 0.28 m (1 sigma).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the reliability of the standing measurement of hand-to-foot bioimpedance compared with measurements made in the lying position.Research Methods and Procedures: In 205 volunteers 6 to 89 years of age, 111 males and 94 females from six ethnic groups, effects of posture, time, and age on hand-to-foot resistance were studied over a range of body size. The effect of time in a position on resistance was also recorded in a small subset (n = 10), and repeat measurements over 3 days at the same time of the day were recorded in another subset (n = 12).Results: Lying impedance was consistently higher than standing, with the relationship (resistance lying/resistance standing) for the children (5 to 14 years) being 1.031, progressing to a ratio of 1.016 in those >60 years. The time spent static in either position did change resistance measurements - a decrease of up to 9 Omega (mean 5 Omega, 1.0%) over 10 minutes of standing and an increase of up to 7 Omega (mean 3 Omega, 0.7%) with lying.Discussion: In the field, measurements of hand-to-foot bioimpedance can be made in the standing position, and, with appropriate adjustment, previously validated recumbent equations can be used. Given that errors in the measurement of height and weight also affect the reliability of the derivation of body fat from bioelectrical conductance, the errors that may arise from a more practical standing measurement rather than lying are minimal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the positioning systems that compose GNSS (Global Navigation Satellite System), GPS has the capability of providing low, medium and high precision positioning data. However, GPS observables may be subject to many different types of errors. These systematic errors can degrade the accuracy of the positioning provided by GPS. These errors are mainly related to GPS satellite orbits, multipath, and atmospheric effects. In order to mitigate these errors, a semiparametric model and the penalized least squares technique were employed in this study. This is similar to changing the stochastical model, in which error functions are incorporated and the results are similar to those in which the functional model is changed instead. Using this method, it was shown that ambiguities and the estimation of station coordinates were more reliable and accurate than when employing a conventional least squares methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we present a novel 1x2 multi-mode-interferometer-Fabry-Perot (MMI-FP) laser diode, which demonstrated tunable single frequency operation with more than 30dB side mode suppression ratio (SMSR) and a tuning range of 25nm in the C and L bands, as well as a 750 kHz linewidth. These lasers do not require material regrowth and high resolution gratings; resulting in a simpler process that can significantly increase the yield and reduce the cost.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bioelectrical impedance measurements are widely used for the study of body composition. Commonly measurements are made at 50 kHz to estimate total body water or at low frequencies (< 10 kHz) to estimate extracellular fluid volume. These measurements can be obtained as single measurements at discrete frequencies, or as fitted data interpolated from plots of measurements made at multiple frequencies. This study compared single frequency and multiple frequency (MF) measurements taken in the intensive care environment. MF bioimpedance (4-1000 kHz) was measured on an adult with and without cardiorespiratory monitoring, and on babies in the neonatal intensive care unit. Measurements obtained at individual frequencies were plotted against frequency and examined for the presence of outlying points. Fitted data for measurements obtained at 5 kHz and 50 kHz with and without cardiorespiratory monitoring were compared. Significant artefacts were detected in measurements at approximately 50 kHz and at integral divisions of this frequency as a result of interference from cardiorespiratory monitors. Single frequency measurements taken at these frequencies may be subject to errors that would be difficult to detect without the aid of information obtained from MF measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multi-frequency bioimpedance analysis (MFBIA) was used to determine the impedance, reactance and resistance of 103 lamb carcasses (17.1-34.2 kg) immediately after slaughter and evisceration. Carcasses were halved, frozen and one half subsequently homogenized and analysed for water, crude protein and fat content. Three measures of carcass length were obtained. Diagonal length between the electrodes (right side biceps femoris to left side of neck) explained a greater proportion of the variance in water mass than did estimates of spinal length and was selected for use in the index L-2/Z to predict the mass of chemical components in the carcass. Use of impedance (Z) measured at the characteristic frequency (Z(c)) instead of 50 kHz (Z(50)) did not improve the power of the model to predict the mass of water, protein or fat in the carcass. While L-2/Z(50) explained a significant proportion of variation in the masses of body water (r(2) 0.64), protein (r(2) 0.34) and fat (r(2) 0.35), its inclusion in multi-variate indices offered small or no increases in predictive capacity when hot carcass weight (HCW) and a measure of rib fat-depth (GR) were present in the model. Optimized equations were able to account for 65-90 % of the variance observed in the weight of chemical components in the carcass. It is concluded that single frequency impedance data do not provide better prediction of carcass composition than can be obtained from measures of HCW and GR. Indices of intracellular water mass derived from impedance at zero frequency and the characteristic frequency explained a similar proportion of the variance in carcass protein mass as did the index L-2/Z(50).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Questions about reliability of bioimpedance analysis (BIA) in morbidly obese subjects have curtailed its use in this setting, but metabolic implications might reignite the debate. In a prospective study, it was aimed to analyze anthropometric and clinical associations. Methods: Bariatric candidates (n = 94) with or without metabolic syndrome were consecutively investigated. Age was 34.9 +/- 10.4 years (68.1% females), and BMI was 40.8 +/- 4.6 kg m(-2). Methods included single-frequency BIA, anthropometrics, inflammatory indices, and general biochemical profile. Results: Body composition results (water, fat) in females, but not in males, were entirely consistent with the literature. In both genders good association was observed with anthropometrics (BMI, waist circumference), inflammatory indices (ferritin, C-reactive protein) and general biochemical variables. Anthropometric measurements also displayed comparable associations. Multivariate tests including the two sets of measurements indicated no predominance of one method over the other, one complementing the other as metabolic marker. Conclusions: BIA limitations were mostly relevant for males, not females. Despite such discrepancies, good associations with anthropometry were demonstrated for both genders. Correlations with liver enzymes, and indices of protein, carbohydrate, and lipid metabolism could be demonstrated. BIA deserves more investigations concerning liver steatosis and ongoing inflammation, and it could contribute as well, synergistically with anthropometry, to monitor weight loss, body fat shifts, and metabolic risk. Am. J. Hum. Biol. 23: 420-422, 2011. (c) 2011 Wiley-Liss, Inc.