230 resultados para Shoes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metrics such as passengers per square metre have been developed to define optimum or crowded rail passenger density. Whilst such metrics are important to operational procedures, service evaluation and reporting, they fail to fully capture and convey the ways in which passengers experience crowded situations. This paper reports findings from a two year study of rail passenger crowding in five Australian capital cities which involved a novel mixed-methodology including ethnography, focus groups and an online stated preference choice experiment. The resulting data address the following four fundamental research questions: 1) to what extent are Australian rail passengers concerned by crowding, 2) what conditions exacerbate feelings of crowdedness, 3) what conditions mitigate feelings of crowdedness, and 4) how can we usefully understand passengers’ experiences of crowdedness? It concludes with some observations on the significance and implications of these findings for customer service provision. The findings outlined in this paper demonstrate that the experience of crowdedness (including its tolerance) cannot be understood in isolation from other customer services issues such as interior design, quality of environment, safety and public health concerns. It is hypothesised that tolerance of crowding will increase alongside improvements to overall customer service. This was the first comprehensive study of crowding in the Australian rail industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To describe barefoot, shod and in-shoe kinematics during stance phase of walking gait in a normal arched adult population. An equal sample of males and females (n = 24) was recruited. In order to quantify the effect of footwear independent of technical design features, an ASICS shoe (Onitsuka Tiger-Mexico 66, Japan) was used in this study. Markers were applied to three conditions; barefoot, shod, and in-shoe. The calibration markers were used to define static pose. The order of testing was randomised. Participants completed five trials in each condition. Kinematic data were captured using a 12 camera VICON MX40 motion capture system at 100 Hz and processed in Visual3D. A previously developed model was used to describe joint angles [1]. A univariate two-way ANOVA was used to identify any differences between the pairs of conditions. Post-hoc Sheffé tests were used to further interrogate the data for differences. At peak hallux dorsiflexion (Figure 1), during propulsion, the metatarsophalangeal joint (MPTJ) was significantly more dorsiflexed in the barefoot condition compared to the shod condition (p = 0.004). At the same gait event, the tibiocalcaneal joint (TCJ) was significantly more plantarflexed than both the shod and in-shoe conditions (p < 0.001), and the tarsometatarsal joint (TMTJ) was significantly less dorsiflexed in the barefoot condition compared to the shod and in-shoe conditions (p < 0.001). The findings of the current study demonstrate that footwear has significant effects on sagittal plane MPTJ joint dorsiflexion at peak hallux dorsiflexion, which results in compensations at proximal foot joints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Footwear remains a prime candidate for the prevention and rehabilitation of Achilles tendinopathy as it is thought to decrease tension in the tendon through elevation of the heel. However, evidence for this effect is equivocal. Purpose: This study used an acoustic transmission technique to investigate the effect of running shoes on Achilles tendon loading during barefoot and shod walking. Methods: Acoustic velocity was measured in the Achilles tendon of twelve recreationally–active males (age, 31±9 years; height, 1.78±0.06 m; weight, 81.0±16.9 kg) during barefoot and shod walking at matched self–selected speed (3.4±0.7 km/h). Standard running shoes incorporating a 10– mm heel offset were used. Vertical ground reaction force and spatiotemporal parameters were determined with an instrumented treadmill. Axial acoustic velocity in the Achilles tendon was measured using a custom built ultrasonic device. All data were acquired at a rate of 100 Hz during 10s of steady–state walking. Statistical comparisons between barefoot and shod conditions were made using paired t–tests and repeated measure ANOVAs. Results: Acoustic velocity in the Achilles tendon was highly reproducible and was typified by two maxima (P1, P2) and minima (M1, M2) during walking. Footwear resulted in a significant increase in step length, stance duration and peak vertical ground reaction force compared to barefoot walking. Peak acoustic velocity in the Achilles tendon (P1, P2) was significantly higher with running shoes. Conclusions: Peak acoustic velocity in the Achilles tendon was higher with footwear, suggesting that standard running shoes with a 10–mm heel offset increase tensile load in the Achilles tendon. Although further research is required, these findings question the therapeutic role of standard running shoes in Achilles tendinopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Young females with mild hallux valgus (HV) have been identified as having an increased risk of first ray deformation. Little is known, however, about the biomechanical changes that might contribute to this increased risk. The purpose of this study was to compare kinetics changes during walking for mild HV subjects with high-heel-height shoes. Twelve female subjects (six with mild HV and six controls) participated in this study with heel height varying from 0 cm (barefoot) to 4.5 cm. Compared to healthy controls, patients had significantly higher peak pressure on the big toe area during barefoot walking. When the heel height increased, loading was transferred to medial side of the forefoot, and the big toe area suffered more impact compared to barefoot in mild HV. This study also demonstrated that the center of pressure (COP) inclines to medial side alteration after high-heeled shoes wearing. These findings indicate that mild HV people should be discouraged from wearing high-heeled shoes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to examine the changes of energy cost during a high-heeled continuous jogging.Thirteen healthy female volunteers jointed in this study with heel height of the shoes varied from 1, 4.5 and 7 cm, respectively. Each subjects jogged on the treadmill with K4b2 portable gas analysis system. The results of this study showed that ventilnation, relative oxygen consumption and energy expenditure increased with the increase of heel height and these values shows significantly larger when the heel height reached to 7 cm. Present study suggest that wearing high heel shoes jogging could directly increase energy consumption, causing neuromuscular fatigue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Henry Marx was born in Michelstadt/Hessen and emigrated to New York with his family in early 1937 when he was nine years old. He went to school but also delivered newspapers and shined shoes to help his family financially as his father only worked whatever odd jobs he could during the war years. Going from store to store shining shoes on weekends was Henry's main source of income. He had to wake up early in order to reserve the spot shown in this photograph, competing with a father and two sons who traveled from Brooklyn to Washington Heights to shine shoes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors investigated generativity – the concern in establishing and guiding the next generation – as a mediator of the relationship between family business owners' age and succession in family businesses. Data came from 155 family business owners in Germany from different industries between the ages of 26 and 83 years. Results showed that age was positively related to generativity, and that generativity, in turn, positively influenced an objective measure of family succession. Generativity fully mediated the positive relationship between age and family succession. The findings suggest that generativity is an important psycho-social construct for understanding ageing, careers and succession in family business settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to investigate the use of custom-made orthopedic shoes (OS) and the association between the use of OS and the most relevant aspects of their usability. Over a 6-month period, patients meeting the inclusion criteria were recruited by 12 orthopedic shoe companies scattered throughout the Netherlands and asked to complete a questionnaire composed of a pre- and post-OS section. Patients with different pathologies were included in the study (n = 339; response 67%). Mean age of the patients was 63 +/- 15 years, and 38% were male. Three months after delivery, 81% of the patients used their OS frequently (4-7 days/week), 13% occasionally (1-3 days/week), and 6% did not use their OS. Associations were found between use and all measured aspects of usability (p-values varied from <0.001 to 0.028). Patients who used their OS more often had a more positive opinion regarding all the aspects of usability. We conclude that all aspects of the usability of OS are relevant in relation to their use and should be taken into account when prescribing and evaluating OS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the association between patients' expectations and the actual use of custom-made orthopaedic shoes. Design: A prospective cohort study with internal comparison. Setting: Twelve orthopaedic shoe companies. Patients: During six months, consecutive patients who were provided with their first ever pair of orthopaedic shoes and aged 16 years or older were recruited. A total of 339 patients with different pathologies were included (response 67%). Mean (SD) age of the patients was 63 (15) years, and 129 patients (38%) were male. Main measures: A practical and reproducible questionnaire, measuring: frequency of use of orthopaedic shoes, patients' expectations and experiences of aspects of the usability of orthopaedic shoes, and communication about patients' expectations. Results: Patients' expectations were not associated with the use of orthopaedic shoes (P-values range: 0.106 to 0.607), but the difference between expectations and experiences was (P-values range: <0.001 to 0.012). The expectations of patients who frequently used their orthopaedic shoes were in concordance with their experiences, whereas the expectations of patients who did not use their orthopaedic shoes were much higher than their experiences. There was no communication of patients' expectations with the medical specialist or orthopaedic shoe technician in 34% and 25% of the patients respectively. Conclusions: In relation to the actual use of orthopaedic shoes, it is crucial that patients' expectations are not much higher than their experiences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated long-term use of custom-made orthopedic shoes (OS) at 1.5 years follow-up. In addition, the association between short-term outcomes and long-term use was studied. Patients from a previously published study who did use their first-ever pair of OS 3 months after delivery received another questionnaire after 1.5 years. Patients with different pathologies were included in the study (n = 269, response = 86%). Mean age was 63 ± 14 years, and 38% were male. After 1.5 years, 87% of the patients still used their OS (78% frequently [4-7 days/week] and 90% occasionally [1-3 days/week]) and 13% of the patients had ceased using their OS. Patients who were using their OS frequently after 1.5 years had significantly higher scores for 8 of 10 short-term usability outcomes (p-values ranged from <0.001 to 0.046). The largest differences between users and nonusers were found for scores on the short-term outcomes of OS fit and communication with the medical specialist and shoe technician (effect size range = 0.16 to 0.46). We conclude that patients with worse short-term usability outcomes for their OS are more likely to use their OS only occasionally or not at all at long-term follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To develop a short and easy to use questionnaire to measure use and usability of custom-made orthopaedic shoes, and to investigate its reproducibility. DESIGN Development of the questionnaire (Monitor Orthopaedic Shoes) was based on a literature search, expert interviews, 2 expert meetings, and exploration and testing of reproducibility. The questionnaire comprises 2 parts: a pre part, measuring expectations; and a post part, measuring experiences. Patients The pre part of the final version was completed twice by 37 first-time users before delivery of their orthopaedic shoes. The post part of the final version was completed twice by 39 first-time users who had worn their orthopaedic shoes for 2–4 months. RESULTS High reproducibility scores (Cohen’s kappa > 0.60 or intra class correlation > 0.70) were found in all but one question of both parts of the final version of the Monitor Orthopaedic Shoes questionnaire. The smallest real difference on a visual analogue scale (100 mm) ranged from 21 to 50 mm. It took patients approximately 15 minutes to complete one part. CONCLUSION Monitor Orthopaedic Shoes is a practical and reproducible questionnaire that can measure relevant aspects of use and usability of orthopaedic shoes from a patient’s perspective.