909 resultados para Shear wave


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Real-time viscosity measurement remains a necessity for highly automated industry. To resolve this problem, many studies have been carried out using an ultrasonic shear wave reflectance method. This method is based on the determination of the complex reflection coefficient`s magnitude and phase at the solid-liquid interface. Although magnitude is a stable quantity and its measurement is relatively simple and precise, phase measurement is a difficult task because of strong temperature dependence. A simplified method that uses only the magnitude of the reflection coefficient and that is valid under the Newtonian regimen has been proposed by some authors, but the obtained viscosity values do not match conventional viscometry measurements. In this work, a mode conversion measurement cell was used to measure glycerin viscosity as a function of temperature (15 to 25 degrees C) and corn syrup-water mixtures as a function of concentration (70 to 100 wt% of corn syrup). Tests were carried out at 1 MHz. A novel signal processing technique that calculates the reflection coefficient magnitude in a frequency band, instead of a single frequency, was studied. The effects of the bandwidth on magnitude and viscosity were analyzed and the results were compared with the values predicted by the Newtonian liquid model. The frequency band technique improved the magnitude results. The obtained viscosity values came close to those measured by the rotational viscometer with percentage errors up to 14%, whereas errors up to 96% were found for the single frequency method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shear deformation of fault gouge or other particulate materials often results in observed strain localization, or more precisely, the localization of measured deformation gradients. In conventional elastic materials the strain localization cannot take place therefore this phenomenon is attributed to special types of non-elastic constitutive behaviour. For particulate materials however the Cosserat continuum which takes care of microrotations independent of displacements is a more appropriate model. In elastic Cosserat continuum the localization in displacement gradients is possible under some combinations of the generalized Cosserat elastic moduli. The same combinations of parameters also correspond to a considerable dispersion in shear wave propagation which can be used for independent experimental verification of the proposed mechanism of apparent strain localization in fault gouge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To investigate the differences in viscoelastic properties between normal and pathologic Achilles tendons ( AT Achilles tendon s) by using real-time shear-wave elastography ( SWE shear-wave elastography ). Materials and Methods The institutional review board approved this study, and written informed consent was obtained from 25 symptomatic patients and 80 volunteers. One hundred eighty ultrasonographic (US) and SWE shear-wave elastography studies of AT Achilles tendon s without tendonopathy and 30 studies of the middle portion of the AT Achilles tendon in patients with tendonopathy were assessed prospectively. Each study included data sets acquired at B-mode US (tendon morphology and cross-sectional area) and SWE shear-wave elastography (axial and sagittal mean velocity and relative anisotropic coefficient) for two passively mobilized ankle positions. The presence of AT Achilles tendon tears at B-mode US and signal-void areas at SWE shear-wave elastography were noted. Results Significantly lower mean velocity was shown in tendons with tendonopathy than in normal tendons in the relaxed position at axial SWE shear-wave elastography (P < .001) and in the stretched position at sagittal (P < .001) and axial (P = .0026) SWE shear-wave elastography . Tendon softening was a sign of tendonopathy in relaxed AT Achilles tendon s when the mean velocity was less than or equal to 4.06 m · sec(-1) at axial SWE shear-wave elastography (sensitivity, 54.2%; 95% confidence interval [ CI confidence interval ]: 32.8, 74.4; specificity, 91.5%; 95% CI confidence interval : 86.3, 95.1) and less than or equal to 5.70 m · sec(-1) at sagittal SWE shear-wave elastography (sensitivity, 41.7%; 95% CI confidence interval : 22.1, 63.3; specificity, 81.8%; 95% CI confidence interval : 75.3, 87.2) and in stretched AT Achilles tendon s, when the mean velocity was less than or equal to 4.86 m · sec(-1) at axial SWE shear-wave elastography (sensitivity, 66.7%; 95% CI confidence interval : 44.7, 84.3; specificity, 75.6%; 95% CI confidence interval : 68.5, 81.7) and less than or equal to 14.58 m · sec(-1) at sagittal SWE shear-wave elastography (sensitivity, 58.3%; 95% CI confidence interval : 36.7, 77.9; specificity, 83.5%; 95% CI confidence interval : 77.2, 88.7). Anisotropic results were not significantly different between normal and pathologic AT Achilles tendon s. Six of six (100%) partial-thickness tears appeared as signal-void areas at SWE shear-wave elastography . Conclusion Whether the AT Achilles tendon was relaxed or stretched, SWE shear-wave elastography helped to confirm and quantify pathologic tendon softening in patients with tendonopathy in the midportion of the AT Achilles tendon and did not reveal modifications of viscoelastic anisotropy in the tendon. Tendon softening assessed by using SWE shear-wave elastography appeared to be highly specific, but sensitivity was relatively low. © RSNA, 2014.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans le contexte de la caractérisation des tissus mammaires, on peut se demander ce que l’examen d’un attribut en échographie quantitative (« quantitative ultrasound » - QUS) d’un milieu diffusant (tel un tissu biologique mou) pendant la propagation d’une onde de cisaillement ajoute à son pouvoir discriminant. Ce travail présente une étude du comportement variable temporel de trois paramètres statistiques (l’intensité moyenne, le paramètre de structure et le paramètre de regroupement des diffuseurs) d’un modèle général pour l’enveloppe écho de l’onde ultrasonore rétrodiffusée (c.-à-d., la K-distribution homodyne) sous la propagation des ondes de cisaillement. Des ondes de cisaillement transitoires ont été générés en utilisant la mèthode d’ imagerie de cisaillement supersonique ( «supersonic shear imaging » - SSI) dans trois fantômes in-vitro macroscopiquement homogènes imitant le sein avec des propriétés mécaniques différentes, et deux fantômes ex-vivo hétérogénes avec tumeurs de souris incluses dans un milieu environnant d’agargélatine. Une comparaison de l’étendue des trois paramètres de la K-distribution homodyne avec et sans propagation d’ondes de cisaillement a montré que les paramètres étaient significativement (p < 0,001) affectès par la propagation d’ondes de cisaillement dans les expériences in-vitro et ex-vivo. Les résultats ont également démontré que la plage dynamique des paramétres statistiques au cours de la propagation des ondes de cisaillement peut aider à discriminer (avec p < 0,001) les trois fantômes homogènes in-vitro les uns des autres, ainsi que les tumeurs de souris de leur milieu environnant dans les fantômes hétérogénes ex-vivo. De plus, un modéle de régression linéaire a été appliqué pour corréler la plage de l’intensité moyenne sous la propagation des ondes de cisaillement avec l’amplitude maximale de déplacement du « speckle » ultrasonore. La régression linéaire obtenue a été significative : fantômes in vitro : R2 = 0.98, p < 0,001 ; tumeurs ex-vivo : R2 = 0,56, p = 0,013 ; milieu environnant ex-vivo : R2 = 0,59, p = 0,009. En revanche, la régression linéaire n’a pas été aussi significative entre l’intensité moyenne sans propagation d’ondes de cisaillement et les propriétés mécaniques du milieu : fantômes in vitro : R2 = 0,07, p = 0,328, tumeurs ex-vivo : R2 = 0,55, p = 0,022 ; milieu environnant ex-vivo : R2 = 0,45, p = 0,047. Cette nouvelle approche peut fournir des informations supplémentaires à l’échographie quantitative statistique traditionnellement réalisée dans un cadre statique (c.-à-d., sans propagation d’ondes de cisaillement), par exemple, dans le contexte de l’imagerie ultrasonore en vue de la classification du cancer du sein.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A major UK initiative, entitled 'Mapping the Underworld', is seeking to address the serious social, environmental and economic consequences arising from an inability to locate the buried utility service infrastructure without resorting to extensive excavations. Mapping the Underworld aims to develop and prove the efficacy of a multi-sensor device for accurate remote buried utility service detection, location and, where possible, identification. One of the technologies to be incorporated in the device is low-frequency vibro-acoustics, and the application of this technology for detecting buried infrastructure is currently being investigated. Here, a shear wave ground vibration technique for detecting buried pipes is described. For this technique, shear waves are generated at the ground surface, and the resulting ground surface vibrations measured, using geophones, along a line traversing the anticipated run of the pipe. Measurements were made at a test site with a single pressurized polyethylene mains water pipe. Time-extended signals were employed to generate the illuminating wave. Cross-correlation functions between the measured ground velocities and a reference measurement adjacent to the excitation were then calculated and summed using a stacking method to generate a cross-sectional image of the ground. The wide cross-correlation peaks caused by high ground attenuation were partially compensated for by using a generalized cross-correlation function called the smoothed coherence transform. To mitigate the effects of other potential sources of vibration in the vicinity, the excitation signal was used as an additional reference when calculating the generalized cross-correlation functions. For two out of three tests, the pipe was detected, indicating that this technique will be a valuable addition to the Mapping the Underworld armoury.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Degeneration of tendon tissue is a common cause of tendon dysfunction with the symptoms of repeated episodes of pain and palpable increase of tendon thickness. Tendon mechanical properties are directly related to its physiological composition and the structural organization of the interior collagen fibers which could be altered by tendon degeneration due to overuse or injury. Thus, measuring mechanical properties of tendon tissue may represent a quantitative measurement of pain, reduced function, and tissue health. Ultrasound elasticity imaging has been developed in the last two decades and has proved to be a promising tool for tissue elasticity imaging. To date, however, well established protocols of tendinopathy elasticity imaging for diagnosing tendon degeneration in early stages or late stages do not exist. This thesis describes the re-creation of one dynamic ultrasound elasticity imaging method and the development of an ultrasound transient shear wave elasticity imaging platform for tendon and other musculoskeletal tissue imaging. An experimental mechanical stage with proper supporting systems and accurate translating stages was designed and made. A variety of high-quality tissue-mimicking phantoms were made to simulate homogeneous and heterogeneous soft tissues as well as tendon tissues. A series of data acquisition and data processing programs were developed to collect the displacement data from the phantom and calculate the shear modulus and Young’s modulus of the target. The imaging platform was found to be capable of conducting comparative measurements of the elastic parameters of the phantoms and quantitatively mapping elasticity onto ultrasound B-Mode images. This suggests the system has great potential for not only benefiting individuals with tendinopathy with an earlier detection, intervention and better rehabilitation, but also for providing a medical tool for quantification of musculoskeletal tissue dysfunction in other regions of the body such as the shoulder, elbow and knee.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shear-wave splitting can be a useful technique for determining crustal stress fields in volcanic settings and temporal variations associated with activity. Splitting parameters were determined for a subset of local earthquakes recorded from 2000-2010 at Yellowstone. Analysis was automated using an unsupervised cluster analysis technique to determine optimum splitting parameters from 270 analysis windows for each event. Six stations clearly exhibit preferential fast polarization values sub-orthogonal to the direction of minimum horizontal compression. Yellowstone deformation results in a local crustal stress field differing from the regional field dominated by NE-SW extension, and fast directions reflect this difference rotating around the caldera maintaining perpendicularity to the rim. One station exhibits temporal variations concordant with identified periods of caldera subsidence and uplift. From splitting measurements, we calculated a crustal anisotropy of ~17-23% and crack density ~0.12-0.17 possibly resulting from stress-aligned fluid filled microcracks in the upper crust and an active hydrothermal system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Compressional (Vp) and shear (Vs) wave velocities have been measured to 1.0 kbar for 14 cores of well-consolidated sedimentary rock from Atlantic and Pacific sites of the Deep Sea Drilling Project. The range of VP (2.05-5.38 km/sec at 0.5 kbar) shows significant overlap with the range of oceanic layer-2 seismic velocities determined by marine refraction surveys, suggesting that sedimentary rocks may, in some regions, constitute the upper portion of layer 2. Differing linear relationships between VP and Vs for basalts and sedimentary rocks, however, may provide a method of resolving layer-2 composition. This is illustra ted for a refraction survey site on the flank of the Mid-Atlantic Ridge where layer-2 velocities agree with basalt, and two sites on the Saya de Malha Bank in the Indian Ocean where layer-2 velocities appear to represent sedimentary rock.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prior to the Deep Sea Drilling Project the composition of the oceanic crust could only be inferred from seismic-refraction and gravity data and the recovery of a wide variety of dredged rocks. Through the success of the Deep Sea Drilling Project, it is now clear that the top of oceanic Layer 2 usually consists of basalt. Several laboratory studies (e.g., Fox et al., 1972; Christensen and Shaw, 1970; Hyndman and Drury, 1976) have demonstrated that the seismic velocities of oceanic basalt are similar to velocities reported from refraction studies of Layer 2 and that the variability in Layer 2 velocities has many causes, the most important being fracturing and sea-floor alteration produced by the interaction of basalt and sea water (Christensen and Salisbury, 1973). To date, most reported measurements of velocities in oceanic basalts are from samples obtained from the main ocean basins. With the exception of an earlier study of velocities and related elastic properties of a suite of rocks from DSDP Sites 292, 293, 294, and 296 located in the Philippine Sea (Christensen et al., 1975; Fountain et al., 1975), elastic properties have not been determined for oceanic rocks from marginal basins. In this chapter compressional- and shear-wave velocities and elastic constants are reported at elevated confining pressures for basalt and volcanic breccias from Holes 447A, 448, and 448A.