998 resultados para Shading effect


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Concentrator solar cell front-grid metallizations are designed so that the trade-off between series resistance and shading factor (SF) is optimized for a particular irradiance. High concentrator photovoltaics (CPV) typically requires a metallic electrode pattern that covers up to 10% of the cell surface. The shading effect produced by this front electrode results in a significant reduction in short-circuit current (I SC) and hence, in a significant efficiency loss. In this work we present a cover glass (originally meant to protect the cell surface) that is laser-grooved with a micrometric pattern that redirects the incident solar light towards interfinger regions and away from the metallic electrodes, where they would be wasted in terms of photovoltaic generation. Quantum efficiency (QE) and current (I)-voltage (V) characterization under concentration validate the proof-of-concept, showing great potential for CPV applications

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The scope of this research work was to investigate biogas production and purification by a two-step bench-scale biological system, consisting of fed-batch pulse-feeding anaerobic digestion of mixed sludge, followed by methane enrichment of biogas by the use of the cyanobacterium Arthrospira platensis. The composition of biogas was nearly constant, and methane and carbon dioxide percentages ranged between 70.5-76.0% and 13.2-19.5%, respectively. Biogas yield reached a maximum value (about 0.4 m(biogas)(3)/kgCOD(i)) at 50 days-retention time and then gradually decreased with a decrease in the retention time. Biogas CO(2) was then used as a carbon source for A. platensis cultivation either under batch or fed-batch conditions. The mean cell productivity of fed-batch cultivation was about 15% higher than that observed during the last batch phase (0.035 +/- 0.006 g(DM)/L/d), likely due to the occurrence of some shading effect under batch growth conditions. The data of carbon dioxide removal from biogas revealed the existence of a linear relationship between the rates of A. platensis growth and carbon dioxide removal from biogas and allowed calculating carbon utilization efficiency for biomass production of almost 95%. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper focuses on a PV system linked to the electric grid by power electronic converters, identification of the five parameters modeling for photovoltaic systems and the assessment of the shading effect. Normally, the technical information for photovoltaic panels is too restricted to identify the five parameters. An undemanding heuristic method is used to find the five parameters for photovoltaic systems, requiring only the open circuit, maximum power, and short circuit data. The I- V and the P- V curves for a monocrystalline, polycrystalline and amorphous photovoltaic systems are computed from the parameters identification and validated by comparison with experimental ones. Also, the I- V and the P- V curves under the effect of partial shading are obtained from those parameters. The modeling for the converters emulates the association of a DC-DC boost with a two-level power inverter in order to follow the performance of a testing commercial inverter employed on an experimental system. © 2015 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper focuses on a PV system linked to the electric grid by power electronic converters, identification of the five parameters modeling for photovoltaic systems and the assessment of the shading effect. Normally, the technical information for photovoltaic panels is too restricted to identify the five parameters. An undemanding heuristic method is used to find the five parameters for photovoltaic systems, requiring only the open circuit, maximum power, and short circuit data. The I–V and the P–V curves for a monocrystalline, polycrystalline and amorphous photovoltaic systems are computed from the parameters identification and validated by comparison with experimental ones. Also, the I–V and the P–V curves under the effect of partial shading are obtained from those parameters. The modeling for the converters emulates the association of a DC–DC boost with a two-level power inverter in order to follow the performance of a testing commercial inverter employed on an experimental system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV and solar thermal collectors by producing heat and electricity simultaneously. In this paper, the electrical performance evaluation of a low concentrating PVT collector was done through two testing parts: power comparison and performance ratio testing. For the performance ratio testing, it is required to identify and measure the factors affecting the performance ratio on a low concentrating PVT collector. Factors such as PV cell configuration, collector acceptance angle, flow rate, tracking the sun, temperature dependence and diffuse to irradiance ratio. Solarus low concentrating PVT collector V12 was tested at Dalarna University in Sweden using the electrical equipment at the solar laboratory. The PV testing has showed differences between the two receivers. Back2 was producing 1.8 energy output more than Back1 throughout the day. Front1 and Front2 were almost the same output performance. Performance tests showed that the cell configuration for Receiver2 with cells grouping (6- 32-32-6) has proved to have a better performance ratio when to it comes to minimizing the shading effect leading to more output power throughout the day because of lowering the mismatch losses. Different factors were measured and presented in this thesis in chapter 5. With the current design, it has been obtained a peak power at STC of 107W per receiver. The solar cells have an electrical efficiency of approximately 19% while the maximum measured electrical efficiency for the collector was approximately 18 % per active cell area, in addition to a temperature coefficient of -0.53%/ ˚C. Finally a recommendation was done to help Solarus AB to know how much the electrical performance is affected during variable ambient condition and be able to use the results for analyzing and introducing new modification if needed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar sistemas de consorciação entre milho e Brachiaria decumbens e seus efeitos sobre a nutrição mineral das culturas. O experimento foi conduzido no ano agrícola de 2005, na Área Experimental do Campus Delza Gitaí, pertencente ao CECA-UFAL. Os tratamentos consistiram do cultivo de um híbrido de milho BRS 3150, nos sistemas: Preparo Convencional do Solo, Cultivo Mínimo e Semeadura Direta (BRS 3150 em consórcio com Brachiaria decumbens). O experimento obedeceu ao esquema de blocos casualisados com parcelas subdivididas em quatro repetições. Durante o período de florescimento da cultura do milho, foram coletadas folhas da base da espiga para análise nutricional. Foram realizadas coletas de material vegetal da Brachiaria decumbens em quatro épocas para determinação de massa seca; para análise nutricional, utilizou-se material vegetal proveniente da terceira coleta. Pôde-se observar que a presença da Brachiaria decumbens não interferiu na nutrição mineral da cultura do milho; o efeito residual da adubação realizada para cultura do milho beneficiou a Brachiaria decumbens, elevando seu valor nutritivo; a Brachiaria decumbens teve seu crescimento limitado, quando cultivada em consórcio, devido ao efeito do sombreamento proporcionado pela cultura do milho.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A remoção da vegetação para dar lugar a edificações e superfícies pavimentadas implica na anulação de diversos serviços ambientais. Entre eles está o sombreamento, que impede a aquecimento do ar derivado da re-emissão da radiação solar pelas superfícies. O ar quente e seco contribui para o aumento da sensação de desconforto e favorece a incidência de doenças respiratórias. O objetivo deste trabalho foi analisar valores de temperatura e umidade do ar, comparando-se dados coletados por estações meteorológicas automáticas instaladas em regiões arborizadas e áridas da cidade, durante a ocorrência de episódios representativos do clima da região. Os procedimentos metodológicos, baseados na Climatologia Dinâmica, consistiram em relacionar a sucessão de tipos de tempo meteorológico de escala regional às diferenças observadas entre os pontos de estudo, provocadas por fenômenos provenientes das atividades humanas. Isto permitiu a clara identificação de variações climáticas críticas para o conforto e a saúde humanos, tais como grandes amplitudes térmicas e baixos valores de umidade do ar. Os resultados mostraram amplitudes térmicas menores nas áreas arborizadas (em média 3ºC) e, em alguns casos, umidade do ar mais elevada em comparação aos valores observados nas partes áridas estudadas. Estas verificações reforçam a afirmação da necessidade de ampliação das áreas verdes de São Carlos, que contribuem na atenuação as condições climáticas de desconforto e insalubridade. Em conseqüência, aumentam a qualidade de vida da população e as condições de sustentabilidade do ambiente urbano. Tal afirmação vem ao encontro da legislação ambiental brasileira e dos anseios da população são-carlense. Espera-se que as constatações deste trabalho sejam um elemento adicional na adoção de políticas públicas mais comprometidas com a saúde humana e ambiental.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plant growth regulators and biostimulants have been used as an agronomic technique to optimize the production of seedlings in various crops. This study aimed to evaluate the influence of gibberellic acid and the biostimulant Stimulate® on the initial growth of tamarind (Tamarindus indica L.). The experiments were conducted in a nursery with 50% shading, in a randomized block design with five replications and five plants per plot. Thirty eight days after sowing, the leaves were sprayed seven times a day with 0.0 (control), 0.8, 1.6, 2.4 and 3.2 mL of gibberellic acid L-1 aqueous solution and with 0.0 (control), 6.0,12.0, 18.0, and 24.0 mL Stimulate® L-1 aqueous solution. Stem diameter (SD), plant height (PH), longest root length (LRL), shoot dry mass (SDM), root dry mass (RDM) and RDM:SDM ratio were evaluated ninety days after sowing. Variance and regression analysis showed that GA3 at 4% promoted plant growth (height), but had no significant effect on stem diameter, longest root length, shoot and root dry mass and the RDM:SDM ratio. On the other hand, all concentrations of Stimulate® significantly increased plant height and shoot and root dry mass of tamarind seedlings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vochysia tucanorum Mart. (Vochysiaceae) is a very widely distributed species in the cerrado and forests in Brazil, from the State of Bahia to Paraná. Its seed germination was analysed under eight treatments using different conditions of light and temperature. Up to 73 days, at least ca. 93% of the seeds germinated in all treatments, except under alternating temperatures of 35°/10°C (62%). Light enhanced germination, except under constant temperature of 25°C when seeds are not photoblastic. At this temperature, the highest percentage of germination was found. Initial vegetative growth was analysed by comparing the effects of shading, by means of different percentages of full daylight (100%, 45%, 10.6%, 4.8%), and soils from cerrado and forest. During 123 days, no mortality was recorded and cotyledons persisted on the seedlings of all treatments. In general, the seedlings of V. tucanorum were found to be more or less indifferent to the soil from cerrado or forest and shading seems to promote height increment. However, total dry mass was larger under a radiation of 45% full daylight and smaller under extreme conditions (100% or 4.8% full daylight).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Under low latitude conditions, minimization of solar radiation within the urban environment may often be a desirable criterion in urban design. The dominance of the direct component of the global solar irradiance under clear high sun conditions requires that the street solar access must be small. It is well known that the size and proportion of open spaces has a great influence on the urban microclimate This paper is directed towards finding the interaction between urban canyon geometry and incident solar radiation. The effect of building height and street width on the shading of the street surfaces and ground for different orientations have been examined and evaluated. It is aimed to explore the extent to which these parameters affect the temperature in the street. This work is based on air and surface temperature measurements taken in different urban street canyons in EL-Oued City (hot and and climate), Algeria. In general, the results show that there are less air temperature variations compared to the surface temperature which really depends on the street geometry and sky view factor. In other words, there is a big correlation between the street geometry, sky view factor and surface temperatures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Under low latitude conditions, minimisation of solar irradiance within the urban environment may often be an important criterion in urban design. This can be achieved when the obstruction angle is large (high H/W ratio, H = height, W = width). Solar access to streets can always be decreased by increasing H/W to larger values. It is shown in this paper that the street canyon orientation (and not only the H/W ratio) has a considerable effect on solar shading and urban microclimate. The paper demonstrates through a series of shading simulation and temperature measurements that a number of useful relationships can be developed between the geometry and the microclimate of urban street canyons. These relationships are potentially helpful to assist in the formulation of urban design guidelines governing street dimensions and orientations for use by urban designers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of shading and water sprinkling on physiological responses and milk production were studied in Holstein cows managed in an equatorial semi-arid region. Five cows were observed for 36 days during May and June 2009. We studied the effects of sun, shade, shade plus single sprinkling, shade plus sprinkling every 2. h and shade plus sprinkling every hour on physiological responses, i.e., rectal temperature, coat surface temperature and respiratory rate, and on milk production. Environmental variables, i.e., air temperature, black globe temperature, mean radiant temperature, relative humidity and wind speed, were recorded every 30. min throughout the observation period. The statistical analysis utilized a 5×5 replicated latin square, and the results showed reduced values in physiological variables in cows that were protected from short wave radiation and that received water sprinkling; milk yield increased by approximately 3.5. kg in such animals relative to those not receiving such treatment. However, the milk yield for the morning milking presented similar mean values regardless of whether the animals received shading and sprinkling benefits, which indicates that frequency of sprinkling and amount of time (permanence) in the shade were critical for the effect on milk yield. © 2013 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)