901 resultados para Shading devices
Resumo:
This paper evaluates the thermal and luminous performance of different louver configurations on an office room model located in Maceió-AL (Brazil), ranking the alternatives in a way that leads to choices for alternatives with potential balanced performance. Parametric analyses were done, based on computer simulations on software Troplux 5 and DesignBuilder 2. The variables examined were number of slats, slat slope and slat reflectance, considering the window facing North, South, East and West and a fixed shading mask for each orientation. Results refer to internal average illuminance and solar heat gains through windows. It was observed that configurations of shading devices with the same shading mask may have different luminous and thermal performance. The alternatives were ranked, so the information here produced has the potential to support decisions on designing shading devices in practice.
Resumo:
Modern design of civil constructions such as office blocks, airport terminal buildings, factories, etc. incorporates more and more environmental considerations that lead to, amongst other elements, the use of glazed façades with shading devices to optimize energy consumption. These shading devices, normally slats or louvers, are very flexible structures exposed to the action of wind, and therefore aeroelastic effects such as galloping must be taken into account in their design. A typical cross-section for such elements is a Z-shaped profile made out of a central web and two side wings. The results of a parametric analysis based on static wind tunnel tests and performed on different Z-shaped louvers to determine translational galloping instability regions are presented in this paper.
Resumo:
This paper describe a simulation program, which uses Trengenza’s average room illuminance method in conjunction with hourly solar irradiance and luminous efficacy, to predict the potential lighting energy saving for a side-lit room. Two lighting control algorithms of photoelectric switching (on/off) and photoelectric dimming (top-up) have been coded in the program. A simulation for a typical UK office room has been conducted and the results show that energy saving due to the sunlight dependent on the various factors such as orientation, control methods, building depth, glazing area and shading types, etc. This simple tool can be used for estimating the potential lighting energy saving of the windows with various shading devices at the early design stage.
Resumo:
In order to exploit the passive energy potential of the building envelope, it is important to provide a right combination of insulation thickness, heat capacity and night-time ventilation. In this paper, this issue will be tackled with reference to an historic building in Catania (Southern Italy). The building was built at the end of the XIX century, and its opaque envelope is entirely made with lava stones, which is typical of traditional architecture in this area. Starting from the current configuration of the building, many hypotheses for refurbishment are considered, combined with different strategies for passive cooling, such as night-time ventilation, use of shading devices and adoption of highly-reflective coatings. The effectiveness of each solution in terms of summer thermal comfort is evaluated through dynamic thermal simulations carried out with EnergyPlus. The results show the synergic effect of these strategies, as well as their individual impact, and allow to draw some general conclusions about the behaviour of heavyweight buildings under moderately hot weather conditions.
Resumo:
Com caráter informativo, inicia-se apresentando a relação entre a climatologia e o ambiente construído, em seus campos especificos de aplicação (urbanismo, projeto de edificações, execução de obras, e manutenção e uso das construções), considerando-se os aspectos históricos, econômico-ecológicos e os ligados à súde e ao conforto do usuário, abrangidos por tal relação. A importância da disponibilidade de informações climatológicas é então comentada, bem como diversas metodalagias de análise e representação de dados climáticos. Com caráter aplicativo, apresenta-se uma contribuigão à caracterização climática da cidade de Porto Alegre, RS. São analisadas os valores médios horários-mensais doa principais parâmetros climáticos disponíveis (temperatura, umidade, velocidade e direção do vento, e nebulosidade), propondo-se uma representação gráfica sintética alternativa para os mesmos. A análise é complementada pala execução de dois procedimentos técnicos: avaliação do conforto térmico, com identificação do período critico de verão, e projeto de dispositivo de sombreamento de aberturas retangulares. Embora esteja em foco o caso específico de Porto Alegre, tais metodologias encontram-se descritas de modo a serem aplicadas a qualquer outra localidade, procurando-se ampliar a utilidade prática do presente estudo.
Resumo:
Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces
Resumo:
Los fenómenos aeroelásticos son relativamente frecuentes en las construcciones civiles modernas como edificios de oficinas, terminales de aeropuertos o fábricas. En este tipo de arquitectura aparecen con frecuencia estructuras flexibles sometidas a la acción del viento, como por ejemplo persianas formadas por láminas con distintos perfiles. Uno de estos perfiles es el perfil en Z, formado por un elemento central y dos alas laterales. Las inestabilidades de tipo galope se determinan en la práctica utilizando el criterio Glauert-Den Hartog. Este criterio precisa de la predicción exacta de la dependencia de los coeficientes aerodinámicos del ángulo de ataque. En esta tesis se presenta un estudio sistemático, tanto por métodos experimentales como numéricos de una familia completa de perfiles en Z que permite determinar sus regiones de inestabilidad frente al galope. Los análisis numéricos han sido validados con ensayos estáticos realizados en túnel de viento. Para la parte numérica se ha utilizado el código DLR TAU, que es un código de amplia utilización en la industria aeronáutica europea. En esta tesis se enfoca sobre todo a la predicción del galope en este tipo de perfiles en Z. Los resultados se presentan en forma de mapas de estabilidad. A lo largo del trabajo se realizan también comparaciones entre resultados numéricos y experimentales para varios niveles de detalle de las mallas empleadas y diversos modelos de turbulencia. ABSTRACT Aeroelastic effects are relatively common in the design of modern civil constructions such as office blocks, airport terminal buildings, and factories. Typical flexible structures exposed to the action of wind are shading devices, normally slats or louvers. A typical cross-section for such elements is a Z-shaped profile,made out of a central web and two-sidewings. Galloping instabilities are often determined in practice using the Glauert-DenHartog criterion.This criterion relies on accurate predictions of the dependence of the aerodynamic force coefficients with the angle of attack. The results of a parametric analysis based on both experimental and numerical analysis and performed on different Z-shaped louvers to determine translational galloping instability regions are presented in this thesis. These numerical analysis results have been validated with a parametric analysis of Z-shaped profiles based on static wind tunnel tests. In order to perform this validation, the DLR TAU Code, which is a standard code within the European aeronautical industry, has been used. This study highlights the focus on the numerical prediction of the effect of galloping, which is shown in a visible way, through stability maps. Comparisons between numerical and experimental data are presented with respect to various meshes and turbulence models.
Resumo:
En esta tesis se estudia cómo lograr el equilibrio entre dos fenómenos naturales que afectan a los huecos de fachadas: la iluminación natural y la ganancia solar. Es decir, el cómo, conseguir la optimización de la iluminación natural que se introduce a través de las ventanas existentes, sin realizar una laboriosa intervención de sustitución de las mismas y el cómo, conseguir la protección de la radiación solar directa de la zona acristalada, para evitar tanto las ganancias térmicas innecesarias como el deslumbramiento que afecta a la calidad lumínica de los recintos. Para el desarrollo esta investigación se ha propuesto una metodología de estudio dividida en dos fases: La primera, de Análisis y Diagnóstico, en la que se han de definir los estándares a cumplir y las variables con las que se evaluarán las bandejas. Y, la segunda, de Evaluación y Comprobación en la que se han de establecer los criterios de valoración y ponderación de cada variable. En la primera fase, se definirán las variables físico-ambientales, para lo que se seleccionarán algunas ciudades a estudiar, a las cuales se les estudiará las necesidades de confort térmico, se determinarán las dimensiones que deben tener las protecciones solares en esas ciudades, además se determinarán las actuaciones a realizar en los huecos de fachada según sea su posición en el plano vertical de la misma. Así mismo, se plantea hacer un análisis de casos reales, para lo que se caracterizarán desde el punto de vista lumínico algunas viviendas, realizando medidas “in situ” y comparando resultados con los que se obtienen de los programas de simulación, para seleccionar las viviendas en las que la realidad y la simulación se aproximen más, una de estas viviendas servirá de modelo en las simulaciones que se realizará en la segunda fase. También, en esta primera fase, mediante un modelo neutro, se estudiará el comportamiento térmico y lumínico del tamaño del hueco en el que se insertará la bandeja posteriormente, para luego estudiar la posición de la bandeja en el plano vertical de la ventana, desde el punto de vista ergonómico. Y finalmente se estudiará, el comportamiento térmico y lumínico del modelo con la bandeja ubicada a 40, 50 y 60cm del techo. En la segunda fase, se establecerá la valoración y ponderación de las variables con las que seleccionar la bandeja que mejor equilibre los aspectos térmicos y lumínicos, teniendo en cuenta estrategias pasivas de acondicionamiento ambiental, como favorecer las ganancias solares en invierno en horas diurnas y evitar las pérdidas de calor en horas nocturnas; y en verano implementar sistemas de sombreamiento en la zona acristalada para evitar las ganancias de calor; y, tanto en verano como en invierno, aprovechar la iluminación natural, para favorecer la iluminancia útil y evitar el deslumbramiento. Una vez definidos los criterios de valoración y ponderación se aplicará a la evaluación térmica y lumínica del modelo neutro con la bandeja, consiguiendo seleccionar la bandeja con mejor comportamiento. Posteriormente se comprobará la metodología de estudio desarrollada en el modelo seleccionado, se evaluará el comportamiento térmico y lumínico, con la incorporación de algunas alternativas de bandeja. Con esta investigación se quiere demostrar que mediante la aplicación de esta metodología de estudio, es posible evaluar y seleccionar bandejas que respondan a las necesidades requeridas en distintos casos de estudio, por lo que se considera que, la bandeja puede ser un elemento arquitectónico aplicable tanto en rehabilitación como en nueva construcción, de espacios en los que sea necesario mejorar sus condiciones lumínicas y térmicas simultáneamente. ABSTRACT This thesis studies how to balance two natural events that affect the window opening of facades: daylighting and solar gain. That is to say, how to achieve optimization of natural light that gets in through the existing windows, without making a laborious intervention of replacing them and how to get protection from direct solar radiation from the glass area, to avoid unnecessary heat gain and glare affecting the light quality of the enclosures. To develop this research, it has been proposed a methodology of study divided into two phases: First phase, Analysis and Diagnostics, in which the variables with which the light shelf are evaluated will be defined along with the standards the light shelves will meet. The second phase, Assessment and Verification, in which the assessment criteria and weighting of each variable will be established. In the first phase, the physical and environmental variables shall be defined, various cities will be selected to be studied, and in each the needs of thermal comfort will be determined along with the dimensions of shading devices in the cities. In addition the actions to be taken in the window opening of the façade will be determined, depending on their position in the vertical plane. An analysis of real cases will be undertaken, which will be characterized from the luminous point of view, performing "in situ" measurements and comparing results with those obtained from simulation programs, to select places/dwellings where reality and simulation are closer, one of these places/dwellings will be a model, in the simulations to perform at the second phase. Also, in this first phase, by a neutral model, the thermal and light behavior of the size of the window opening will be studied, in which the light shelf is inserted later, the position of the light shelf in the vertical plane of the window is studied, from an ergonomic point of view. And finally to study the thermal and light behavior of the model with the light shelf located at 40, 50 and 60cm from the ceiling. In the second phase, the evaluation and weighting of the variables will be established selecting the light shelf that best balances the thermal and daylighting aspects, taking into account passive environmental conditioning strategies; such as getting solar gains in winter during daylight hours, and preventing heat loss during the night hours; and in summer implementing shading systems in the glazing area to avoid heat gains. And in both summer and winter, taking advantage of natural lighting, to improve useful illuminance and avoid glare. Once defined, the evaluation criteria and weighting will be applied to thermal and daylighting evaluation to the neutral model with the light shelf, the best performing light shelf will be selected. The study methodology developed in the selected model will be verified the thermal and daylighting performance with the addition of some light shelf alternative will also be studied. With this research, we want to show that by applying this study methodology it is possible to evaluate and select the light shelf that meets the needs required in different case studies, so it is considered that the light shelf may be an applicable architectural element in both refurbishment and new construction of spaces where necessary to improve their daylighting and thermal conditions simultaneously.
Resumo:
The city of Natal has a significant daylight availability, although it use isn’t systematically explored in schools architecture. In this context, this research aims to determine procedures for the analysis of the daylight performance in school design in Natal-RN. The method of analysis is divided in Visible Sky Factor (VSF), simulating and analyzing the results. The annual variation of the daylight behavior requires the adoption of dynamic simulation as data procedure. The classrooms were modelled in SketchUp, simulated in Daysim program and the results were assessed by means of spreadsheets in Microsoft Excel. The classrooms dimensions are 7.20mx 7.20m, with windows-to-wall-ratio (WWR) of 20%, 40% and 50%, and with different shading devices, such as standard horizontal overhang, sloped overhang, standard horizontal overhang with side view protection, standard horizontal overhang with a dropped edge, standard horizontal overhang with three horizontal louvers, double standard horizontal overhang, double standard horizontal overhang with three horizontal louvers, plus the use of shelf light in half the models with WWR of 40% and 50%. The data was organized in spreadsheets, with two intervals of UDI: between 300lux and 2000 lux and between 300lux and 3000lux. The simulation was performed with the weather file of 2009 to the city of NatalRN. The graphical outputs are illuminance curves, isolines of UDI among 300lux and 2000 lux and tables with index of occurrences of glare and to an UDI among 300lux 3000lux. The best UDI300-2000lux performance was evidenced to: Phase 1 (models with WWR of 20%), Phase 2 (models with WWR of 40% and 50% with light shelf). The best UDI300-3000lux performance was evidenced to: Phase 1 (models with WWR of 20% and 40% with light shelf) and Phase 2 (models with WWR of 40% and 50% with light shelf). The outputs prove that the daylight quality mainly depends on the shading system efficacy to avoid the glare occurrence, which determines the daylight discomfort. The bioclimatic recommendations of big openings with partial shading (with an opening with direct sunlight) resulted in illuminances level higher than the acceptable upper threshold. The improvement of the shading system percentage (from 73% to 91%) in medium-size of openings (WWR 40% and 50%) reduced or eliminate the glare occurrence without compromising the daylight zone depth (7.20m). The passive zone was determined for classrooms with satisfactory daylight performance, it was calculated the daylight zone depth rule-of-thumb with the ratio between daylight zone depth and the height of the window for different size of openings. The ratio ranged from 1.54 to 2.57 for WWR of 20%, 40% and 50% respectively. There was a reduction or elimination of glare in the passive area with light shelf, or with awning window shading.
Resumo:
Harnessing solar energy to provide for the thermal needs of buildings is one of the most promising solutions to the global energy issue. Exploiting the additional surface area provided by the building’s façade can significantly increase the solar energy output. Developing a range of integrated and adaptable products that do not significantly affect the building’s aesthetics is vital to enabling the building integrated solar thermal market to expand and prosper. This work reviews and evaluates solar thermal facades in terms of the standard collector type, which they are based on, and their component make-up. Daily efficiency models are presented, based on a combination of the Hottel Whillier Bliss model and finite element simulation. Novel and market available solar thermal systems are also reviewed and evaluated using standard evaluation methods, based on experimentally determined parameters ISO 9806. Solar thermal collectors integrated directly into the facade benefit from the additional wall insulation at the back; displaying higher efficiencies then an identical collector offset from the facade. Unglazed solar thermal facades with high capacitance absorbers (e.g. concrete) experience a shift in peak maximum energy yield and display a lower sensitivity to ambient conditions than the traditional metallic based unglazed collectors. Glazed solar thermal facades, used for high temperature applications (domestic hot water), result in overheating of the building’s interior which can be reduced significantly through the inclusion of high quality wall insulation. For low temperature applications (preheating systems), the cheaper unglazed systems offer the most economic solution. The inclusion of brighter colour for the glazing and darker colour for the absorber shows the lowest efficiency reductions (<4%). Novel solar thermal façade solutions include solar collectors integrated into balcony rails, shading devices, louvers, windows or gutters.
Resumo:
Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces
Resumo:
Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces
Resumo:
Paper has become increasingly recognized as a very interesting substrate for the construction of microfluidic devices, with potential application in a variety of areas, including health diagnosis, environmental monitoring, immunoassays and food safety. The aim of this review is to present a short history of analytical systems constructed from paper, summarize the main advantages and disadvantages of fabrication techniques, exploit alternative methods of detection such as colorimetric, electrochemical, photoelectrochemical, chemiluminescence and electrochemiluminescence, as well as to take a closer look at the novel achievements in the field of bioanalysis published during the last 2 years. Finally, the future trends for production of such devices are discussed.
Resumo:
We reported here for the first time that triboelectric charges on PET sheets can be used to seal and control the flow rate in paper-based devices. The proposed method exhibits simplicity and low cost, provides reversible sealing and minimizes the effect of sample evaporation.
Resumo:
Colloidal particles have been used to template the electrosynthesis of several materials, such as semiconductors, metals and alloys. The method allows good control over the thickness of the resulting material by choosing the appropriate charge applied to the system, and it is able to produce high density deposited materials without shrinkage. These materials are a true model of the template structure and, due to the high surface areas obtained, are very promising for use in electrochemical applications. In the present work, the assembly of monodisperse polystyrene templates was conduced over gold, platinum and glassy carbon substrates in order to show the electrodeposition of an oxide, a conducting polymer and a hybrid inorganic-organic material with applications in the supercapacitor and sensor fields. The performances of the resulting nanostructured films have been compared with the analogue bulk material and the results achieved are depicted in this paper.