914 resultados para Sewage Purification Biological treatment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite recent developments in fixed-film combined biological nutrients removal (BNR) technology; fixed-film systems (i.e., biofilters), are still at the early stages of development and their application has been limited to a few laboratory-scale experiments. Achieving enhanced biological phosphorus removal in fixed-film systems requires exposing the micro-organisms and the waste stream to alternating anaerobic/aerobic or anaerobic/anoxic conditions in cycles. The concept of cycle duration (CD) as a process control parameter is unique to fixed-film BNR systems, has not been previously investigated, and can be used to optimise the performance of such systems. The CD refers to the elapsed time before the biomass is re-exposed to the same environmental conditions in cycles. Fixed-film systems offer many advantages over suspended growth systems such as reduced operating costs, simplicity of operation, absence of sludge recycling problems, and compactness. The control of nutrient discharges to water bodies, improves water quality, fish production, and allow water reuse. The main objective of this study was to develop a fundamental understanding of the effect of CD on the transformations of nutrients in fixed-film biofilter systems subjected to alternating aeration I no-aeration cycles A fixed-film biofilter system consisting of three up-flow biofilters connected in series was developed and tested. The first and third biofilters were operated in a cyclic mode in which the biomass was subjected to aeration/no-aeration cycles. The influent wastewater was simulated aquaculture whose composition was based on actual water quality parameters of aquacuture wastewater from a prawn grow-out facility. The influent contained 8.5 - 9:3 mg!L a111monia-N, 8.5- 8.7 mg/L phosphate-P, and 45- 50 mg!L acetate. Two independent studies were conducted at two biofiltration rates to evaluate and confirm the effect of CD on nutrient transformations in the biofilter system for application in aquaculture: A third study was conducted to enhance denitrification in the system using an external carbon- source at a rate varying from 0-24 ml/min. The CD was varied in the range of0.25- 120 hours for the first two studies and fixed at 12 hours for the third study. This study identified the CD as an important process control parameter that can be used to optimise the performance of full-scale fixed-film systems for BNR which represents a novel contribution in this field of research. The CD resulted in environmental conditions that inhibited or enhanced nutrient transformations. The effect of CD on BNR in fixed-film systems in terms of phosphorus biomass saturation and depletion has been established. Short CDs did not permit the establishment of anaerobic activity in the un-aerated biofilter and, thus, inhibited phosphorus release. Long CDs resulted in extended anaerobic activity and, thus, resulted in active phosphorus release. Long CDs, however, resulted in depleting the biomass phosphorus reservoir in the releasing biofilter and saturating the biomass phosphorus reservoir in the up-taking biofilter in the cycle. This phosphorus biomass saturation/depletion phenomenon imposes a practical limit on how short or long the CD can be. The length of the CD should be somewhere just before saturation or depletion occur and for the system tested, the optimal CD was 12 hours for the biofiltration rates tested. The system achieved limited net phosphorus removal due to the limited sludge wasting and lack of external carbon supply during phosphorus uptake. The phosphorus saturation and depletion reflected the need to extract phosphorus from the phosphorus-rich micro-organisms, for example, through back-washing. The major challenges of achieving phosphorus removal in the system included: (I) overcoming the deterioration in the performance of the system during the transition period following the start of each new cycle; and (2) wasting excess phosphorus-saturated biomass following the aeration cycle. Denitrification occurred in poorly aerated sections of the third biofilter and generally declined as the CD increased and as the time progressed in the individual cycle. Denitrification and phosphorus uptake were supplied by an internal organic carbon source, and the addition of an external carbon source (acetate) to the third biofilter resulted in improved denitrification efficiency in the system from 18.4 without supplemental carbon to 88.7% when the carbon dose reached 24 mL/min The removal of TOC and nitrification improved as the CD increased, as a result of the reduction in the frequency of transition periods between the cycles. A conceptual design of an effective fixed-film BNR biofilter system for the treatment of the influent simulated aquaculture wastewater was proposed based on the findings of the study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Supported by Division of Water Supply and Pollution Control U.S. Public Health Service Research Project WP-138.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Micronutrients play a very important role in biological processes for wastewater treatment. Many industrial wastewaters lack in nutrients (macronutrients and micronutrients) required for microbial growth, and this is one of the main problems at many activated sludge plants treating industrial wastewater. The microbial community structure is one of the important factors controlling the pollutant-degrading capacity of biological wastewater treatment system. In this study, the concentrations of micronutrients of the textile wastewater discharged from a textile plant were determined, and the effects of micronutrients on treatment efficiency and microorganism community structure of the biological treatment system were studied. The results showed that the optimal concentrations of magnesium, molybdenum, zinc, thiamine and niacin in the textile wastewater were 5.0, 2.0, 1.0, 1.0 and 1.0mg/L, respectively. The COD removal rates when magnesium, molybdenum, zinc, thiamine and niacin were added individually to the wastewater in their optimal concentrations were 1.8, 1.4, 1.3, 1.6 and 2.2 times of that of the control, respectively. The improving effects of combinations of zinc and thiamine, zinc and niacin, thiamine and niacin were better than single micronutrient. The diversity of quinones (DQ) changed significantly after the micronutrient was added into the wastewater treatment system. This indicated that there was probably a feasibility of optimizing the biological treatment performances and microorganism community structure of textile wastewater treatment system through micronutrient supplement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Micronutrients play an important role in biological processes for wastewater treatment. Many industrial wastewaters lack in nutrients required for microbial growth, and this is one of the problems at many activated sludge plants treating them. In this study, the effects of the micronutrient niacin on the COD removal rates of textile wastewater, together with the effect of Mixed Liquor Suspended Solids (MLSS) on niacin, were studied. Certain improvement effects were found on the removal rates of COD, when 0.5 similar to 2.0 mg/L niacin was added to the textile wastewater. The optimal concentration of niacin was 1.0 mg/L, which was continuously added during textile wastewater treatment, and removal rates were 1.31 times compared to those of the control system. The concentration of MLSS was probably one of the factors influencing treatment efficiency, and the biological performance of treatment system could be optimized through micronutrient niacin supplements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

These updated guidelines are based on a first edition of the World Federation of Societies of Biological Psychiatry Guidelines for Biological Treatment of Schizophrenia published in 2005. For this 2012 revision, all available publications pertaining to the biological treatment of schizophrenia were reviewed systematically to allow for an evidence-based update. These guidelines provide evidence-based practice recommendations that are clinically and scientifically meaningful and these guidelines are intended to be used by all physicians diagnosing and treating people suffering from schizophrenia. Based on the first version of these guidelines, a systematic review of the MEDLINE/PUBMED database and the Cochrane Library, in addition to data extraction from national treatment guidelines, has been performed for this update. The identified literature was evaluated with respect to the strength of evidence for its efficacy and then categorised into six levels of evidence (A-F; Bandelow et al. 2008b, World J Biol Psychiatry 9: 242). This first part of the updated guidelines covers the general descriptions of antipsychotics and their side effects, the biological treatment of acute schizophrenia and the management of treatment-resistant schizophrenia.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Grant no. 12060 DPE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The objective of the study is to explore preferences of gastroenterologists for biosimilar drugs in Crohn’s Disease and reveal trade-offs between the perceived risks and benefits related to biosimilar drugs. Method: Discrete choice experiment was carried out involving 51 Hungarian gastroenterologists in May, 2014. The following attributes were used to describe hypothetical choice sets: 1) type of the treatment (biosimilar/originator) 2) severity of disease 3) availability of continuous medicine supply 4) frequency of the efficacy check-ups. Multinomial logit model was used to differentiate between three attitude types: 1) always opting for the originator 2) willing to consider biosimilar for biological-naïve patients only 3) willing to consider biosimilar treatment for both types of patients. Conditional logit model was used to estimate the probabilities of choosing a given profile. Results: Men, senior consultants, working in IBD center and treating more patients are more likely to willing to consider biosimilar for biological-naïve patients only. Treatment type (originator/biosimilar) was the most important determinant of choice for patients already treated with biologicals, and the availability of continuous medicine supply in the case biological-naïve patients. The probabilities of choosing the biosimilar with all the benefits offered over the originator under current reimbursement conditions are 89% vs 11% for new patients, and 44% vs 56% for patients already treated with biological. Conclusions: Gastroenterologists were willing to trade between perceived risks and benefits of biosimilars. The continuous medical supply would be one of the major benefits of biosimilars. However, benefits offered in the scenarios do not compensate for the change from the originator to the biosimilar treatment of patients already treated with biologicals.