458 resultados para Sealing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We reported here for the first time that triboelectric charges on PET sheets can be used to seal and control the flow rate in paper-based devices. The proposed method exhibits simplicity and low cost, provides reversible sealing and minimizes the effect of sample evaporation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effectiveness of a therapeutic sealant to arrest non-cavitated proximal carious lesion progression. The study population comprised 44 adolescents who had bitewing radiographs taken for caries diagnosis. Non-cavitated lesions extending up to half of dentin thickness were included in the sample. In the experimental group (n = 33), the proximal caries-lesion surfaces were sealed with an adhesive (OptiBond Solo, Kerr) after tooth separation. The control group (n = 11) received no treatment, except for oral hygiene instructions including use of dental floss. Follow-up radiographs were taken after one year and were analyzed in comparison with baseline radiographs. In a blind study setting, visual readings were performed by two examiners, blinded to whether the examined radiograph was baseline or follow-up, and whether it concerned a test or control lesion. The efficacy of sealing treatment was evaluated by the McNemar test (0.05). About 22% of the sealed lesions showed reduction, 61% showed no change and 16% showed progression. For the control lesions, the corresponding values were 27%, 36% and 36% respectively. The number of lesions that showed reduction and no changes were merged and therefore 83.3% of the sealed lesions and 63.6% of the control lesions were considered clinically successful. No statistical significance was detected (p > 0.05). In the course of 1 year, sealing proximal caries lesions was not shown to be superior to lesion monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to test the hypothesis that dentine alterations induced by 810 nm-diode laser may affect the interaction between root canal sealers and the dentin wall. Seventy-two single root human teeth were selected and root canals were enlarged with K-files. Dentine was treated with 0.5% NaOCl and 17% EDTA-T and irradiated (laser group) by diode laser (810 nm/P = 2.5W/I = 1989 W/cm(2)) or remained non-irradiated (control group). Six samples per group were analyzed by scanning electron microscopy (SEM). The remaining samples of each group were divided into three subgroups (n = 10) and sealed with one of the tested sealers (N-Rickert/AHPlus (TM)/Apexit (R)). Apical leakage was estimated by evaluating penetration of 0.5% methylene-blue dye. SEM analysis revealed that dentine at the apical third in irradiated samples was melted and fusioned whereas non-irradiated samples exhibited opened dentinal tubules. Despite the morphological changes induced by irradiation, laser did not affect the sealing ability of N-Rickert and AHPlus (TM) sealers. However, the length of apical leakage in roots filled with Apexit (R) was lower in irradiated root canals than in non-irradiated samples (p < 0.05). Morphological changes of root canal walls promoted by diode laser irradiation may improve de sealing ability of Apexit (R), a calcium hydroxide-based sealer, suggesting that improved sealing promoted by irradiation may represent an additional factor contributing to the endodontic clinical outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSuretrade mark). METHODS: Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSuretrade mark. Samples (5,5l) were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. RESULTS: Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. CONCLUSION: The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proper storage practices are critical to protect materials from intermingling, contamination, or degradation, and to maintain consistent aggregate gradation throughout a project. Concrete Paving Workforce Reference no.3

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates sealing characteristics of two designs of endovascular grafts by angiographic demonstration of exclusion of porcine lumbar arteries. METHODS: 6 endovascular grafts (3 self-expandable with integrated polyurethane wall versus 3 nitinol structures covered with polyester fabric) were implanted in 6 porcine aortae. Perfusion of lumbar arteries was assessed by angiography after implantation and by angiography and dissection at graft explantation after 4 +/- 2 months. Tissue healing was evaluated by light and scanning electron microscopy. RESULTS: Immediate exclusion of the lumbar arteries was achieved in 14/31 vessels (12 by polyurethane grafts and 2 by polyester grafts, p < 0.001). Follow-up angiography and dissection at explantation revealed perfusion of 30/31 lumbar arteries with a collateral network in most cases. Another reason for reperfusion of initially excluded branches was distention of the polyurethane grafts with resulting shortening allowing reperfusion of 8 of the 31 originally covered branches. Histological examination revealed a complete neointimal lining and a tight contact between endovascular grafts and aorta. CONCLUSIONS: The immediate angiographic demonstration of exclusion of lumbar arteries predicts sealing characteristics of endovascular grafts. Later angiographic reappearance is due to development of a collateral network and possible shortening of self-expandable devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Iowa Department of Transportation used a high molecular weight methacrylate (HMWM) resin to seal a 3,340 ft. x 64 ft. bridge deck in October 1986. The sealing was necessary to prevent deicing salt brine from entering a substantial number of transverse cracks that coincided with the epoxy coated top steel and unprotected bottom steel. HMWM resin is a three component product composed of a monomer, a cumene hydroperoxide initiator and a cobalt naphthenate promoter. The HMWM was applied with a dual spray bar system and flat-fan nozzles. Initiated monomer delivered through one spray bar was mixed in the air with promoted monomer from the other spray bar. The application rate averaged 0.956 gallons per 100 square feet for the tined textured driving lanes. Dry sand was broadcast on the surface at an average coverage of 0.58 lbs. per square yard to maintain friction. Coring showed that the HMWM resin penetrated the cracks more than two inches deep. Testing of the treated deck yielded Friction Numbers averaging 33 with a treaded tire compared to 36 prior to treatment. An inspection soon after treatment found five leaky cracks in one of the 15 spans. One inspection during a steady rain showed no leakage, but leakage from numerous cracks occurred during a subsequent rain. A second HMWM application was made on two spans. Leakage through the double application occurred during a rain. Neither the single or double application were successful in preventing leakage through the cracks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four Iowa DOT asphalt concrete pavement crack sealing projects were selected to evaluate the benefits of heat lance crack preparation. Two, one-half mile sections, both with and without heat lance preparation, were constructed in Story, Monroe, Clinton and Wayne Counties in 1991 and 1992. They were visually evaluated annually from 1992 through 1996. The heat lance preparation did not yield improved seal performance or extended longevity. There was no perceivable difference between crack sealing with and without heat lance preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this research was to evaluate the performance of portland cement concrete pavement contraction joints utilizing a variety of sealants and joint preparations and to identify an effective sealant system. The variables evaluated were: (1) sealant material; (2) joint preparation; (3) size of saw cut (sealant reservoir); and (4) the use of backing material. This progress report contains project results to date.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iowa's first portland cement concrete pavement was constructed in 1904 in the City of LeMars. A portion of that pavement served traffic until 1974 at which time it was resurfaced. The first rural Iowa pee pavement (16' wide, 6" to 7" thick) was constructed under the direction of the Iowa State Highway Commission in 1913. Some of Iowa's early pavements had transverse joints at 25-foot spacings. At that time, joint spacings across the nation ranged from 24 to 100 ft. There have been many changes in joint design over the years with some pavements being constructed without transverse joints. Joint spacing on Iowa primary pavements has generally remained around 20 feet with this spacing having been adopted as an Iowa standard in 1954. Until 1978 it was common to specify a 40-foot joint spacing on secondary pavements. The performance of the pavements with joint spacings greater than 20 feet, and in some cases no contraction joints, generated a 1955 research project on joint spacing. This project was 16 miles long containing sections without contraction joints and sections with joints sawed at intervals of 20, 50 and 80 feet. Approximately half of the sawed joints were left unsealed. The results of this research supported the 20-foot spacing, but were inconclusive regarding the benefits of sealing. One of the desired characteristics of joint sealing material is that it should act as a moisture barrier and prevent the intrusion of surface water. It was generally accepted from past experience that the hot poured type joint seals did not provide this effective moisture barrier.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concern about premature joint sealant failures occurring in portland cement concrete (PCC) pavements gave impetus to initiating this research project. Eight sealants, including three silicone sealants, were evaluated and tested in the lab as well as incorporated in approximately 700 joints in the field and evaluated over a six-year period. The preliminary data show that among the silicone sealants, Dow Corning 888 rated the highest. However, this was rated third overall behind the W. R. Meadows cold-applied Sof Seal and Crafco #231 hot pour sealants. The W. R. Meadows and Crafco sealants cost approximately 30 percent and 50 percent less to furnish and place than the Dow Corning product. All joint sealants will continue to be evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Iowa Department of Transportation used a high molecular weight methacrylate (HMWM) resin to seal a 3,340 ft. x 64 ft. bridge deck in October 1986. The sealing was necessary to prevent deicing salt brine from entering a substantial number of transverse cracks that coincided with the epoxy coated top steel and unprotected bottom steel. HMWM resin is a three component product composed of a monomer, a curnene hydroperoxide initiator and a cobalt naphthenate promoter. The HMWM was applied with a dual spray bar system and flat-fan nozzles. Initiated monomer delivered through one spray bar was mixed in the air with promoted monomer from the other spray bar. The application rate averaged 0.956 gallons per 100 square feet for the tined textured driving lanes. Dry sand was broadcast on the surface at an average coverage of 0.58 lbs. per square yard to maintain friction. Coring showed that the H.MWM resin penetrated the cracks more than two inches deep. Testing of the treated deck yielded Friction Numbers averaging 33 with a treaded tire compared to 36 prior to treatment. An inspection soon after treatment found five leaky cracks in one of the 15 spans. One inspection during a steady rain showed no leakage, but leakage from numerous cracks occurred during a subsequent rain. A second HMWM application was made on two spans to determine if a double application would prevent leakage. This evaluation has not been completed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suojakaasupakkaaminen on lisääntynyt voimakkaasti viime vuosina elintarvikkeiden pakkaamisessa sillä pakkaamalla elintarvike suojakaasuun voidaan sen hyllyikää pidentää ilman säilöntäaineita. Tällainen pakkaaminen vaatii kuitenkin täysin kaasutiiviin pakkauksen, jonka kaasunläpäisevyys on myös alhainen. Yleisimmin käytetyt pakkausmateriaalit suojakaasupakkaamisessa ovat monikerroksiset muovimateriaalit, joissa yhdistyy monen eri muovin parhaimmat ominaisuudet. Yleisimmin käytettyjä muovilaatuja näissä monikerrosrakenteissa ovat PE, PET, PA ja EVOH polymeerit. Myös muita perinteisiä polymeerejä käytetään jonkin verran näissä rakenteissa. Uudemmat muovilaadut, kuten biohajoavat muovit, eivät ole vielä yleistyneet kaupallisessa käytössä pääasiallisesti niiden korkean hinnan vuoksi. Muovisten pakkausten korvaamista esimerkiksi muovipäällystetyillä kartonkipakkauksilla on viime vuosien aikana tutkittu enenevissä määrin. Muovipakkausten korvaamista helpommin kierrätettävillä ja mahdollisesti biohajoavilla materiaaleilla edistävät EU:n direktiivit, jotka käsittelevät pakkausjätteen käsittelyä. Kartonkivuokien saumaamista kaasutiiviisti tutkittiin myös tässä työssä. Tavoitteena oli löytää pakkaus, joka soveltuisi kanasuikaleiden pakkaamiseen suojakaasuun. Kana on herkkä mikrobiologiselle hajoamiselle, minkä johdosta se tulee pakata suojakaasuun jossa happipitoisuuden tulee olla alle 1 % pakkauspäivästä viimeiseen käyttöpäivään saakka. Suorittamalla erilaisia tiiveystutkimuksia voitiin osoittaa, että kartonkivuoka on mahdollista saumata kaasutiiviisti luotettavalla tavalla. Tämä vaatii kuitenkin kartonkivuokien valmistuksen optimoimista päällystemuovikerroksen ja kartongin paksuuden mukaan sekä kannen saumaamista optimoiduilla saumausparametreilla. Tiivein vuoka saavutettiin muovifilmikannella, jonka saumaus perustui samaan muoviin kuin vuoan saumaus. Polyeteenillä saavutettiin tiivein ja kestävin saumaustulos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine the efficacy of the pediculate flap with the buccal fat pad in the sealing of orosinusal communications, describe the surgical technique used, and report the main complications. Patients and method: A retrospective study was made of 8 patients seen in the Service of Oral Surgery of the University of Barcelona Dental Clinic (Spain) for the treatment of orosinusal communications between the years 2007 and 2009. In all cases a pediculate flap with the buccal fat pad was used to solve the problem. Results: All of the orosinusal communications were successfully resolved with this technique. The immediate postoperative complications were pain (37.5%), inflammation (37.5%), edema (32.5%), trismus (37.5%), halitosis (14.3%), suppuration (12.5%) and rhinorrhea (12.5%). Conclusions: The use of Bichat"s buccal fat pad is not regarded as the technique of choice for sealing small to medium sized orosinusal communications. However, in the case of large communications, it is a good option, and the results obtained are optimum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional (3D) forming of paperboard and heat sealing of lidding films to trays manufactured by the press forming process are investigated in this thesis. The aim of the work was to investigate and recognize the factors affecting the quality of heat sealing and the leak resistance (tightness) of press-formed, polymer-coated paperboard trays heatsealed with a multi-layer polymer based lidding film. One target was to achieve a solution that can be used in food packaging using modified atmosphere packaging (MAP). The main challenge in acquiring adequate tightness properties for the use of MAP is creases in the sealing area of the paperboard trays which can act as capillary tubes and prevent leak-proof sealing. Several experiments were made to investigate the effect of different factors and process parameters in the forming and sealing processes. Also different methods of analysis, such as microscopic analysis and 3D-profilometry were used to investigate the structure of the creases in the sealing area, and to analyse the surface characteristics of the tray flange of the formed trays to define quality that can be sealed with satisfactory tightness for the use of MAP. The main factors and parameters that had an effect on the result of leak-proof sealing and must be adjusted accordingly were the tray geometry and dimensions, blank holding force in press forming, surface roughness of the sealing area, the geometry and depth of the creases, and the sealing pressure. The results show that the quality of press-formed, polymer-coated paperboard trays and multi-layer polymer lidding films can be satisfactory for the use of modified atmosphere packaging in food solutions. Suitable tools, materials, and process parameters have to be selected and used during the tray manufacturing process and lid sealing process, however. Utilizing these solutions and results makes it possible for a package that is made mostly from renewable and recyclable sources to be a considerable alternative for packages made completely from oil based polymers, and to achieve a greater market share for fibre-based solutions in food packaging using MAP.