993 resultados para Scan techniques


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carbon Fiber Reinforced Plastic composites were fabricated through vacuum resin infusion technology by adopting two different processing conditions, viz., vacuum only in the first and vacuum plus external pressure in the next, in order to generate two levels of void-bearing samples. They were relatively graded as higher and lower void-bearing ones, respectively. Microscopy and C-scan techniques were utilized to describe the presence of voids arising from the two different processing parameters. Further, to determine the influence of voids on impact behavior, the fabricated +45 degrees/90 degrees/-45 degrees composite samples were subjected to low velocity impacts. The tests show impact properties like peak load and energy to peak load registering higher values for the lower void-bearing case where as the total energy, energy for propagation and ductility indexes were higher for the higher void-bearing ones. Fractographic analysis showed that higher void-bearing samples display lower number of separation of layers in the laminate. These and other results are described and discussed in this report.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new system is described for estimating volume from a series of multiplanar 2D ultrasound images. Ultrasound images are captured using a personal computer video digitizing card and an electromagnetic localization system is used to record the pose of the ultrasound images. The accuracy of the system was assessed by scanning four groups of ten cadaveric kidneys on four different ultrasound machines. Scan image planes were oriented either radially, in parallel or slanted at 30 C to the vertical. The cross-sectional images of the kidneys were traced using a mouse and the outline points transformed to 3D space using the Fastrak position and orientation data. Points on adjacent region of interest outlines were connected to form a triangle mesh and the volume of the kidneys estimated using the ellipsoid, planimetry, tetrahedral and ray tracing methods. There was little difference between the results for the different scan techniques or volume estimation algorithms, although, perhaps as expected, the ellipsoid results were the least precise. For radial scanning and ray tracing, the mean and standard deviation of the percentage errors for the four different machines were as follows: Hitachi EUB-240, −3.0 ± 2.7%; Tosbee RM3, −0.1 ± 2.3%; Hitachi EUB-415, 0.2 ± 2.3%; Acuson, 2.7 ± 2.3%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sixteen formalin-fixed foetal livers were scanned in vitro using a new system for estimating volume from a sequence of multiplanar 2D ultrasound images. Three different scan techniques were used (radial, parallel and slanted) and four volume estimation algorithms (ellipsoid, planimetry, tetrahedral and ray tracing). Actual liver volumes were measured by water displacement. Twelve of the sixteen livers also received x-ray computed tomography (CT) and magnetic resonance (MR) scans and the volumes were calculated using voxel counting and planimetry. The percentage accuracy (mean ± SD) was 5.3 ± 4.7%, −3.1 ± 9.6% and −0.03 ± 9.7% for ultrasound (radial scans, ray volumes), MR and CT (voxel counting) respectively. The new system may be useful for accurately estimating foetal liver volume in utero.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

SrBi2Ta2O9 (SBT) thin films on quartz substrates were prepared by use of the pulsed-laser deposition technique. The nonlinear refractive indices, n(2), Of the SBT films were measured by use of z-scan techniques with picosecond pulses. Large negative nonlinear refractive indices of 3.84 and 3.58 cm(2)/GW were obtained for the wavelengths 532 nm and 1.064 mum, respectively. The two-photon absorption coefficient was determined to be 7.3 cm/GW for 532 nm. The limiting behavior of SBT thin film on a quartz substrate was investigated in an f/5 defocusing geometry by use of 38-ps-duration, 532-nm, 1.064-mum. laser excitation. (C) 2001 Optical Society of America.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The low energy collision-induced dissociation, linked scan techniques and isotopic labeling experiment were used to investigate the unimolecular fragmentation of protonated N-hydroxyphthalimide under electron impact and chemical ionization conditions. It was found that this compound shows an unusual reactivity towards protonation. Two possible sites of protonation have been proposed to explain the corresponding fragmentation processes, one is that the protonation takes place on the oxygen atom of hydroxyl group, resulting in the loss of water and the other is the formation of an intermediary proton-bound complex in the fragmentation process, giving rise to the fragment ions of m/z 133 and m/z 135. The results show both cases are coexistence in the fragmentations of protonated N-hydroxyphthalimide, and the unimolecular fragmentation pathways are available.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Both El MS and FAB MS behavior of two groups of compounds, aryltin and ferrocene compounds, have been studied. For the aryltin compounds, the effect of substituent group position, substituent group type and ligand type on the El spectra have been explored in the El MS studies. The fragmentation mechanism has been investigated under El with linked scans, such as fragment ion scans(BJE), parent ion scans(B2JE) and constant neutral radical loss scans(B2(1-E)JE2). In the FAB MS studies, matrix optimization experiments have been carried out. The positive ion FAB MS studies focused on the effect of substituent group position, substituent group type and ligand type on the spectra. The fragmentation mechanisms of all the samples under positive ion FAB have been studied by means of the linked scans. The CA positive ion FAB fragmentation studies were also carried out for a typical sample. Negative ion FAB experiments of all the compounds have been done. And finally, the comparison of the El MS and FAB MS has been made. For ferrocenes, the studies concentrated on the fragmentation mechanism of each compound under El with linked scan techniques in the first field-free region and the applicability of positive/negative ion FAB MS to this group of compounds. The fragmentation mechanisms under positive ion FAB of those ferrocenes which can give positive ion FAB MS spectra were studied with the linked scan techniques. The CA +ve F AB fragmentation studies were carried out for a typical sample. Comparison of the E1 MS and FAB MS has been made.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

nonlinear (NL) refractive index, n(2), of NaPO3-WO3-Bi2O3 glass with different relative amounts of the constituents was measured at 1064 and 800 nm using the Z-scan and the thermally managed eclipse Z-scan techniques, respectively. The values of n(2) >= 10(-15) cm(2)/W and negligible NL absorption coefficient were determined. The large values of the NL refractive index and the very small NL absorption indicate that these materials have large potential for all-optical switching applications. (C) 2009 American Institute of Physics. [doi: 10.1063/1.3212972]

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nonlinear (NL) optical properties of antimony oxide based glasses (AG) were characterized for excitation wavelengths from 800 to 1600 m. The NL refractive indices, n2, and the two-photon absorption (TPA) coefficient, β, have been evaluated using the Z-scan technique. Values of n2≈ 10-15 - 10-14 cm2/W of electronic origin were measured and negligible TPA coefficients (β < 0.003 cm/GW) were determined. The response time of the nonlinearity is faster than 100 fs as determined using the Kerr shutter technique. The figure-of-merit usually considered for all-optical switching, T = 2βλ/n2 , indicates that AG are very good materials for ultrafast switches at telecom wavelengths. © 2007 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present work employs a set of complementary techniques to investigate the influence of outlying Ru(II) groups on the ground- and excited-state photophysical properties of free-base tetrapyridyl porphyrin (H(2)TPyP). Single pulse and, pulse train Z-scan techniques used M association with laser flash photolysis, absorbance and fluorescence spectroscopy, and fluorescence decay measurements, allowed us to conclude that the presence of outlying Ru(II) groups causes significant changes on both electronic structure and vibrational properties of porphyrin. Such modifications take place mainly due to the activation of. nonradiative decay channels responsible for the emission, quenching, as well as by favoring some vibrational modes in the light absorption process, It is also observed that, differently from what happens when the Ru(II) is placed at the center of the macrocycle, the peripheral groups cause an increase of the intersystem crossing processes, probably due to the structural distortion of the ring that implies a worse spin orbit coupling, responsible for the intersystem crossing mechanism.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study, an attempt is made to evaluate certain parameters that might indicate the beginning of a certain fibrogenic activity in the lung parenchyma, even before such changes become visible on the chest x-ray. The hypothesis is that studies such as certain bronchoalveolar immunological characteristics and Gallium-67 lung scans may be more sensitive indicators of parenchymal lung damage in response to asbestos inhalation than conventional radiographic criteria. If so, then in those cases where the criteria for the diagnosis of asbestosis lack the presence of parenchymal changes, it would be unwise to deny the diagnosis unless further investigations, such as the bronchoalveolar lavage fluid analysis and the Gallium-67 lung scan techniques, are made available.^ Four groups of individuals have been included in this study. The volunteer group showing no history of asbestos exposure with normal chest x-rays has been used as a normal healthy comparison group. The other three groups are all asbestos-exposed but differ as to their findings in the chest radiographs. One has parenchymal changes (0/1 or more, ILO Classification), the second has no parenchymal but pleural changes, and the third has neither.^ The most significant laboratory parameter for bronchoalveolar lavage, in this study, is that of Neutrophils (PMNs). All three asbestos-exposed groups showed no differences when compared with each other, while such differences were statistically significant when such groups were separately compared with the normal comparison group. A similar finding existed also when the Helper: Suppressor T-Cell ratios were compared, and found to be higher in all the asbestos-exposed groups.^ Another sensitive test is that of Gallium-67 lung scan. This was found to be positive in some patients where parenchymal changes were absent. Even in some of those who showed neither parenchymal nor pleural changes in their chest x-ray showed positive test results. Such changes indicate a state of an underlying pathogenic process that is still undetectable by conventional radiography. This highly recommends the future application of such tests for the early detection of active pulmonary disease, especially in those who show no parenchymal changes in their chest x-rays. (Abstract shortened with permission of author.) ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recently, a renewed attention has been drawn into the dart-thrower's motion as the radiocarpal joint is unique to humans and this is believed to have played a pivotal role in human evolution. Considering the importance of the motion and the complexity of the wrist joint, there have been many articles discussing the kinematics behind this movement. CT scan techniques have been used in a number of these research activities. Due to limitations in the speed of the image acquisition, the positions of the wrist were recorded in static postures. To our knowledge, a data acquisition for the motion with realtime capturing has not been reported. This paper presents the use of a 3D vision-based motion capture device. Leap Motion Controller (LMC), for measuring the radiocarpal joint angles during the dart-thrower's motion in a real-time analysis. The practical capability of the LMC in measuring dart-thrower's motion was examined in a trial involving four subjects and the angles were compared to the angles acquired from an inertial measurement unit (IMU). The results confirmed the LMC can successfully be used in the application of measuring radiocarpal kinematics" of dart-thrower's motion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nonlinear optical processes in organic compounds have attracted considerable interest in the field of science and technology because of their compelling technological promises in fields of optical communication,computing,switching and signal processing.As a result of the synthesis of novel organic compounds with varying degree of nonlinear optical strength, many practical devices based on these are getting realised giving new theoretical insights into the nonolinear optical behaviour of materials.Organic compounds like phthalocyanines and porphyrins have evoked great deal of interest in the field of photonic technology.The present thesis describes the results obtained from the investigations carried out on the nonlinear optical properties of certain organo-metallic compounds using Z-Scan and DFWM techniques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

International School of Photonics, Cochin University of Science and Technology

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lateral or transaxial truncation of cone-beam data can occur either due to the field of view limitation of the scanning apparatus or iregion-of-interest tomography. In this paper, we Suggest two new methods to handle lateral truncation in helical scan CT. It is seen that reconstruction with laterally truncated projection data, assuming it to be complete, gives severe artifacts which even penetrates into the field of view. A row-by-row data completion approach using linear prediction is introduced for helical scan truncated data. An extension of this technique known as windowed linear prediction approach is introduced. Efficacy of the two techniques are shown using simulation with standard phantoms. A quantitative image quality measure of the resulting reconstructed images are used to evaluate the performance of the proposed methods against an extension of a standard existing technique.