985 resultados para Saphenous vein surgery


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Superficial nerve injuries are very common during varicose vein surgery. In contrast, deep nerve injuries are rare and reported especially when surgery involves the small saphenous vein (SSV). The deep motor nerves most commonly injured are the tibial nerve and the peroneal nerve, which are directly or indirectly affected by extrinsic compression, stretching, or healing process involvement. In this report, two cases of common fibular nerve injury after SSV stripping are described, including treatment used and patient outcomes. Nerve damage mechanisms, anatomy, and prevention strategies are also discussed. In conclusion, fibular nerve damage may occur during SSV stripping. Preventive measures include careful preoperative ultrasonographic investigation of the anatomy of the vein, determining location of the saphenopopliteal joint, and careful dissection far from fibular nerve and restricted to the popliteal fossa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a case of a 71-year-old man with a long coronary artery disease history and two sets of coronary artery bypass grafts. He developed large aortocoronary saphenous vein graft aneurysms in the two grafts from the first set of aortocoronary saphenous venous 20 years later. During the previous 3 years, the aneurysms grew in diameter from 22 to 50 mm. Because of severe renal insufficiency, and in order to avoid jeopardizing the late normal coronary artery bypass grafts by further thoracic surgery, we excluded successfully these altered grafts percutaneously by using 13 coils during the same procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

UNLABELLED: Varicose veins may be due to weakness of the vein wall as a result of structural problems. There are conflicting findings in the literature about these problems especially concerning collagen, elastin and smooth muscle cells content. The aim of this study was to look at the structural abnormalities of varicose veins (with and without valvular incompetence).

MATERIALS AND METHODS: We studied 70 specimens of long saphenous veins from 35 patients (24 with varicose and 11 with normal veins). Two specimens were taken from each vein approximately 3-4 cm from the saphenofemoral junction. Vein specimens were processed for histological and electron microscopic studies. Both qualitative and quantitative analyses were performed to assess the degree of wall changes. Using the image analyzer, contents of collagen, elastin and smooth muscle cells, in addition to intimal and medial thickness, were measured.

RESULTS: Light microscopy revealed significant increase in intimal and medial thickness and collagen content of media and significant decrease in elastin content in varicose veins compared with normal veins. There was no statistical significant difference between varicose veins with and without saphenofemoral valve incompetence. Electron microscopy showed marked degenerative changes in intima and media of varicose veins.

CONCLUSION: The findings in our study supported the theory of primary weakness of the vein wall as a cause of varicosity. This weakness is due to intimal changes, disturbance in the connective tissue components and smooth muscle cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of radial artery conduits in coronary artery bypass grafting (CABG) surgery is associated with improved long-term patency and patient survival rates as compared with saphenous vein conduits. Despite increasing popularity, relative incidence of local harvest-site complications and subjective perception of adverse long-term sequelae remain poorly described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluation of a novel non-invasive tool for postoperative follow-up of patients postelective saphenous vein coronary artery bypass graft (CABG) was performed. Ten patients were included. Their bypass grafts supplied the right coronary artery (7), marginal branches (1), diagonal branches (2), and the circumflex artery (n=1). Each bypass was examined intraoperatively using Doppler flow measurement. Patients were examined with a 3-Tesla magnetic resonance imaging (MRI) scanner (MAGNETOM Verio, Siemens, Erlangen, Germany) within one week postsurgery using MR-angiography with an intravasal contrast agent and velocity encoded phase-contrast flow measurements. Intraoperative Doppler flow measurements revealed regular flow patterns in all vascular territories supplied. The median intraoperative flow rate was 50 ml/min with an inter-quartile range (IQR) of 42-70 ml/min. The clinical postoperative course was uneventful. MRI showed all grafts to be patent. The median postoperative flow rate was 50 ml/min (IQR: 32-65 ml/min). MRI flow rates agreed well with intraoperative Doppler flow measurements (mean difference: -2.8±20.1 ml/min). This initial study demonstrates that 3-Tesla MRI flow measurements correlated well with Doppler thus reconfirming the graft patency postCABG. Further refinement and broader application of this technique may facilitate follow-up postCABG potentially replacing empiric clinical judgment by reliable non-invasive imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Cryopreserved human blood vessels are important tools in reconstructive surgery. However, patency of frozen/thawed conduits depends largely on the freezing/thawing procedures employed. METHODS: Changes in tone were recorded on rings from human saphenous vein (SV) and used to quantify the degree of cryoinjury after different periods of exposure at room temperature to the cryomedium (Krebs-Henseleit solution containing 1.8M dimethyl sulfoxide and 0.1M sucrose) and after different cooling speeds and thawing rates following storage at -196 degrees C. RESULTS: Without freezing, exposure of SV to the cryomedium for up to 240 min did not modify contractile responses to noradrenaline (NA). Pre-freezing exposure to the cryomedium for 10-120 min attenuated significantly post-thaw maximal contractile responses to NA, endothelin-1 (ET-1) and potassium chloride (KCl) by 30-44%. Exposure for 240 min attenuated post-thaw contractile responses to all tested agents markedly by 62-67%. Optimal post-thaw contractile activity was obtained with SV frozen at about -1.2 degrees C/min and thawed slowly at about 15 degrees C/min. In these SV maximal contractile responses to NA, ET-1 and KCl amounted to 66%, 70% and 60% of that produced by unfrozen controls. Following cryostorage of veins for up to 10 years the responsiveness of vascular smooth muscle to NA was well maintained. CONCLUSION: Cryopreservation allows long-term banking of viable human SV with only minor loss in contractility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Conventional harvesting of saphenous vein used for coronary artery bypass surgery induces a vasospasm that is overcome by high-pressure distension. Saphenous vein harvested with its cushion of perivascular tissue by a "no touch" technique does not undergo vasospasm and distension is not required, leading to an improved graft patency. The aim of this study is to investigate the effect of surgical damage and high-pressure distension on endothelial integrity and endothelial nitric oxide synthase expression and activity in saphenous vein harvested with and without perivascular tissue. METHODS: Saphenous veins from patients (n = 26) undergoing coronary artery bypass surgery were prepared with and without perivascular tissue. We analyzed the effect of 300 mm Hg distension on morphology and endothelial nitric oxide synthase/nitric oxide synthase activity using a combination of immunohistochemistry, Western blot analysis, reverse transcriptase polymerase chain reaction, and enzyme assay in distended (with and without perivascular tissue) compared with nondistended (with and without perivascular tissue) segments. RESULTS: Distension induced substantial damage to the luminal endothelium (assessed by CD31 staining) and vessel wall. Endothelial nitric oxide synthase expression and activity were significantly reduced by high-pressure distension and removal of, or damage to, perivascular tissue. The effect of distension was significantly less for those with perivascular tissue than for those without perivascular tissue in most cases. CONCLUSION: The success of the saphenous vein used as a bypass graft is affected by surgical trauma and distension. Veins removed with minimal damage exhibit increased patency rates. We show that retention of perivascular tissue on saphenous vein prepared for coronary artery bypass surgery by the "no touch" technique protects against distension-induced damage, preserves vessel morphology, and maintains endothelial nitric oxide synthase/nitric oxide synthase activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study was undertaken to look for the effect of chloroethylclonidine (CEC) on prejunctional alpha-2 autoreceptors of the canine saphenous vein. The effect was tested on tritium overflow evoked by electrical stimulation from tissues preloaded with 0.2 μM 3H- norepinephrine. Yohimbine (3-300 nM) and CEC (1-125 μM) increased and UK- 14,304 reduced the overflow of tritium evoked by 300 pulses (1 Hz). The maximal increase of tritium overflow caused by yohimbine was much higher than that caused by CEC: 3.82 and 1.74 times, respectively. CEC (5 μM) abolished both the inhibition caused by UK-14,304 and the enhancement of tritium overflow caused by yohimbine. However, when CEC was added after yohimbine, it reduced the electrically evoked overflow of tritium, the maximal effect being a reduction of tritium overflow by 35%. Prazosin (1-100 nM) did not change either the inhibitory effect of UK-14,304 or the facilitatory effect of CEC. These results suggest that CEC acts on two different subtypes of prejunctional alpha-2 autoreceptors; on one of them it acts as an antagonist and increases the electrically evoked overflow of tritium (and inhibits both the effect of UK-14,304 and yohimbine); on the other it acts as an agonist and reduces the electrically evoked overflow of tritium. Alternatively, one can admit that CEC is able to inhibit alpha-2 autoreceptors, which causes an increase of the transmitter release, and to activate a nonadrenergic inhibitory receptor thus causing a reduction of the transmitter release.