505 resultados para SUTURE
Resumo:
Surgical treatment for enterocutaneous fistulas (EF) frequently fails. Cell therapy may represent a new approach to treatment. Mesenchymal stromal cells (MSCs) have high proliferative and differentiation capacity. This study aimed to investigate whether MSCs could adhere to suture filament (SF), promoting better EF healing. MSCs, 1 × 10(6), from adipose tissue (ATMSCs) were adhered to a Polyvicryl SF by adding a specific fibrin glue formulation. Adhesion was confirmed by confocal and scanning electron microscopy (SEM). A cecal fistula was created in 22 Wistar rats by incising the cecum and suturing the opening to the surgical wound subcutaneously with four separate stitches. The animals were randomly allocated to three groups: control (CG)-five animals, EF performed; injection (IG)-eight animals 1 × 10(6) ATMSCs injected around EF borders; and suture filament (SG): nine animals, sutured with 1 × 10(6) ATMSCs attached to the filaments with fibrin glue. Fistulas were photographed on the operation day and every 3 days until the 21st day and analyzed by two observers using ImageJ Software. Confocal and SEM results demonstrated ATMSCs adhered to SF (ATMSCs-SF). The average reduction size of the fistula area at 21st day was greater for the SG group (90.34%, P < 0.05) than the IG (71.80%) and CG (46.54%) groups. ATMSCs adhered to SF maintain viability and proliferative capacity. EF submitted to ATMSCs-SF procedure showed greater recovery and healing. This approach might be a new and effective tool for EF treatment.
Resumo:
To describe a new suture technique for laryngeal microsurgery and to test its applicability in human cadaver larynges. The new technique was experimentally tested in freshly excised human larynges fixed to a larynx holder appropriate for the simulation of laryngeal microsurgery. A mucosal flap was created in the vocal fold for the fabrication of a pocket for subepithelial fat implantation, and the wound edges were then brought together and sutured using the proposed technique. The time necessary for suture was measured with a stopwatch for five successive sutures performed by one of the surgeons. The presence or absence of mucosal rupture was determined for five sutures performed by two surgeons, for a total of 10 sutures. The sutures were performed without the help of an assistant, with no laceration of the mucosa being observed in any of the attempts, and within a relatively short period of time even without previous training. The sutures performed permitted the implanted fat to remain stable under the mucosal flap. Conclusions: the new suture technique is an easy procedure, which can be performed by a single surgeon under microscopic vision, with a low risk of tissue rupture. The technique does not markedly prolong the duration of surgery and a single suture thread can be used for the fabrication of more than one stitch.
Resumo:
BACKGROUND: Restoration of nerve continuity and effective maintenance of coaptation are considered fundamental principles of end-to-end peripheral nerve repair. OBJECTIVE: To evaluate the influence of the number of stitches on axonal regeneration and collagen production after neurorrhaphy. METHODS: Thirty male Wistar rats were equally divided into 3 groups and were all operated on with the right sciatic nerve exposed. In 2 groups, the nerve was sectioned and repaired by means of 3 (group B) or 6 (group C) epineurium sutures with 100 monofilament nylon. One group (group A) was used as a control. Each animal from groups B and C underwent electrophysiological evaluation with motor action potential recordings before nerve section and again at an 8-week interval after neurorrhaphy. Nerve biopsy specimens were used for histomorphometric assessment of axonal regeneration and quantification of collagen at the repair site. RESULTS: Animals from group C had significantly lower motor action potential conduction velocities compared with control animals (P = .02), and no significant difference was seen between groups B and C. Parameters obtained from morphometric evaluation were not significantly different between these 2 groups. Type I collagen and III collagen in the epineurium were significantly higher in group C than in either the control group (P = .001 and P = .003) or group B (P = .01 and P = .02). No differences were identified for collagen I and III in the endoneurium. CONCLUSION: Using 6 sutures for nerve repair is associated with worse electrophysiological outcomes and higher amounts of type I and III collagen in the epineurium compared with control. Neurorraphy with 6 stitches is also related to a significant increase in epineurium collagen I and III compared with 3-stitch neurorraphy.
Resumo:
Background: Several studies have already reported the utilization of fibrin glue in microvascular anastomoses to minimize the number of sutures and to decrease the operative time. Despite the good results obtained in most of these experiments, its clinical application has not launched. The aim of this study was to clarify the controversies around the safeness of fibrin glue application in microvascular anastomoses, and also to demonstrate the potential benefits of fibrin glue application in a realistic free flap model. Methods: Twenty-seven rabbits were used in this study The experimental model consisted of a free groin flap transfer to the anterior cervical region. The flap`s circulation was restored by means of an end-to-side anastomosis between the femoral and carotid arteries, and an end-to-end anastomosis between the femoral and external jugular veins. The animals were divided into two groups (n = 10) according to the anastomosis technique: Group I (conventional suture) and group 11 (fibrin glue). Results: The number of sutures required to complete the arterial and venous anastomoses was reduced in 39 and 37% in group 11, respectively. Despite this reduction, the anastomoses maintained adequate patency rates and mechanical strength. Both arterial and venous anastomoses benefited from fibrin glue application, which made them easier and faster to perform. The flaps` ischemic time and the total operative time were also significantly shortened. Conclusions: In this study, the application of fibrin glue in microvascular anastomoses was safe and reliable. The risk-benefit ratio of fibrin glue application in microvascular anastomoses is favorable for its use. (c) 2008 Wiley-Liss, Inc.
Resumo:
Objective: To present the clinical and radiographic results of a case series of patients with acute acromioclavicular dislocation (MD) treated by arthroscopic coracoclavicular fixation with suture anchors. Method: Twenty patients with AAD with less than 30 days since the injury were submitted to a coracoclavicular stabilization procedure using 2 suture anchors placed at the base of the coracoid process. Each suture anchor was connected to 2 strands of No.2 nonabsorbable-braided sutures, which were passed through the holes drilled in the clavicle and tied to the upper surface of the clavicle. The coracoclavicular distance was measured and compared to the opposite side using radiographic evaluation. Constant and UCLA scores were used to determine clinical and functional evaluation after 6 months. Results: Of the initial twenty cases, six were submitted to a new surgical procedure and were excluded from the study. Of the fourteen patients remaining, only two maintained the initial reduction, while the remainder presented some degree of reduction loss. The Constant and UCLA score averages were 94.79 (82-100) and 32.64 (26-35) respectively. Conclusion: The technique had a high incidence of reduction loss after 6 months of follow up. The clinical and functional evaluation was satisfactory, with a high average score. Level of Evidence: Level III, retrospective study.
Resumo:
Background: Through an experimental biomechanical study on rabbits, tendon reinsertion by means of trans-osseous suture on a spongy bone bed and suture anchor were evaluated comparatively at different phases of healing. Methods: Twenty-four New Zealand White rabbits were used: 2 as pilots, 4 as the control group, and 18 as the experimental group. These 18 animals underwent sectioning and reinsertion of the Achilles tendon bilaterally, using the technique of trans-osseous suture on 1 side and suture anchor on the other. All the pelvic limbs that underwent the procedure were then immobilized for 3 weeks. The experimental group was divided into 3 groups that were sacrificed, respectively, 3, 6, and 12 weeks later. The tendon-bone complex was subjected to biomechanical tests to evaluate the parameters of maximum strength, stiffness, and yield strength. Results: There was no statistically significant difference between the suture anchor group and the trans-osseous suture group, in relation to yield strength (3 weeks, P = .222; 6 weeks, P = .465; and 12 weeks, P = .200) or maximum strength (3 weeks, P = .222; 6 weeks, P = .076; and 12 weeks, P = .078). In relation to stiffness, the suture anchor group showed a statistically significant difference only at 3 weeks of healing ( P = .032) over the trans-osseous suture group. Conclusion: The technique of suturing with an anchor was shown to be similar to the technique of trans-osseous suture for the studied parameters. Level of evidence: Basic Science Study, In-Vitro Biomechanics Study. (C) 2010 Journal of Shoulder and Elbow Surgery Board of Trustees.
Resumo:
For esophageal reconstruction in newborns with esophageal atresia, esophageal reunion with an end-to-end anastomosis is the ideal procedure, although it may result in leaks and strictures due to tension on the suture line, mainly in cases with a wide gap between the ends. Circular myotomy (Livaditis' procedure) is the best method to elongate the proximal esophageal pouch and reduce anastomotic tension. This experimental investigation in dogs was undertaken to attempt to verify that circular myotomy decreases the anastomotic leak rate in newborns with wide gap esophageal atresia, and to analyze whether the technique promotes morphologic changes in the anastomotic scar. A pilot study demonstrated that it is necessary to resect more than 8 cm (40% of the total esophageal length) in order to obtain high leak rates. In the experimental project, such resection was performed in dogs divided into two groups (control group, anastomosis only, and experimental group, anastomosis plus circular myotomy in the proximal esophageal segment). The animals were killed in the 14th postoperative day, submitted to autopsy, and were evaluated as to the presence of leaks and strictures, as well as to the features (macroscopic and microscopic aspects) of the anastomosis. Leak rates were the same in both groups. Morphometric analysis revealed that in animals in the experimental group, the anastomotic scar was thinner than the control animals, and the isolated muscular manchette distal to the site of myotomy was replaced by fibrous tissue. Correspondingly, a decreased number of newly formed small vessels were noted in the experimental animals, compared to control animals. We concluded that circular myotomy does not decrease the incidence of anastomotic leaks, and it also promotes deleterious changes in anastomotic healing.
Resumo:
BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.
Resumo:
PURPOSE: The objective of this study was to investigate the additional burdens in terms of pain, prolongation of surgery and morbidity which is added to elective caesarean section if umbilical hernia suture repair is performed simultaneously. Secondly, patient's satisfaction and hernia recurrence rate were assessed. METHODS: Consecutive women with symptomatic umbilical hernia undergoing internal or external suture repair during elective caesarean were included in this retrospective cohort-control study. Data on post-operative pain, duration of surgery and morbidity of a combined procedure were collected. These patients were matched 1:10 to women undergoing caesarean section only. Additionally, two subgroups were assessed separately: external and internal suture hernia repair. These subgroups were compared for patient's satisfaction, cosmesis, body image and recurrence rate. RESULTS: Fourteen patients with a mean age of 37 years were analysed. Internal suture repair (n = 7) prolonged caesarean section by 20 min (p = 0.001) and external suture repair (n = 7) by 34 min (p < 0.0001). Suture repair did not increase morphine use (0.38 ± 0.2 vs. 0.4 ± 02 mg/kg body weight), had no procedure-related morbidity and prolonged hospitalization by 0.5 days (p = 0.01). At a median follow-up of 37 (5-125) months, two recurrences in each surgical technique, internal and external suture repair, occurred (28 %). Body image and cosmesis score showed a higher level of functioning in internal suture repair (p = 0.02; p = 0.04). DISCUSSION: Despite a high recurrence rate, internal suture repair of a symptomatic umbilical hernia during elective caesarean section should be offered to women if requested. No additional morbidity or scar is added to caesarean section. Internal repair is faster, and cosmetic results are better, additional skin or fascia dissection is avoided, and it seems to be as effective as an external approach. Yet, women must be informed on the high recurrence rate.
Resumo:
OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.
Resumo:
Purpose: Aqueous flow through trabeculectomy blebs has been suggested to influence filtration bleb survival. We investigated the relationship between the requirement to increase aqueous flow via adjustable suture removal and surgical outcomes following "safe trabeculectomy" with mitomycin C (MMC). Methods: 62 consecutive eyes of 53 patients underwent fornix based trabeculectomy with adjustable sutures, intraoperative MMC and intensive postoperative steroids. Subconjunctival antimetabolite injections and bleb needlings were administered according to bleb vascularity and IOP trends. Main outcome measures were: success rates (definition: IOP≤21mmHg and 20% IOP reduction); number of antimetabolite injections; bleb needlings; number of of eyes recommencing glaucoma medications and complications. Results: Mean age was 70.4±16.0 years (mean± SD); mean preoperative IOP was 24.5±9.1 mmHg and decreased to 12.3±8.9mmHg postoperatively. Mean number of sutures was 2.6 ± 0.7. Eyes were divided into 2 groups in relation to the number of sutures removed. The number of subconjunctival MMC injections required for those requiring 2 suture removals was significantly greater than those requiring 1 suture removal (p<0.05) The number of needlings and 5FU injections also increased but did not reach significance (p=0.09 and p=0.34 respectively). Least-squared linear regression analysis showed the number of needlings required had a statistically significant (p=0.05) trend with respect to time elapsed between surgery and first suture removal. No other interventions had significant trends. Mean time between surgery and suture removal was: 4.2±9.2 weeks (suture #1) and 5.7±9.7 weeks (suture#2). Antiglaucoma medication was restarted in only 5 eyes. Postoperative complications were infrequent: Seidel (3.2%), peripheral choroidal effusions at any time (3.2%), and shallow anterior chamber (1.6%). Conclusion: Eyes requiring a greater number of suture removals required a significantly greater number of antifibrosis interventions. The time elapsed before suture removal was inversely related to the number of postoperative needlings, suggesting these eyes may have decreased aqueous production and therefore require aggressive post-operative management to prevent bleb failure.
Resumo:
Abstract: Background Stoma closure has been associated with a high rate of surgical site infection (SSI) and the ideal stoma-site skin closure technique is still debated. The aim of this study was to compare the rate of SSI following primary skin closure (PC) versus a skin-approximating, subcuticular purse-string closure (APS). Methods All consecutive patients undergoing stoma closure between 2002 and 2007 by two surgeons at a single tertiary-care institution were retrospectively assessed. Patients who had a new stoma created at the same site or those without wound closure were excluded. The end point was SSI, determined according to current CDC guidelines, at the stoma closure site and/or the midline laparotomy incision. Results There were 61 patients in the PC group (surgeon A: 58 of 61) and 17 in the APS group (surgeon B: 16 of 17). The two groups were similar in baseline and intraoperative characteristics, except that patients in the PC group were more often diagnosed with benign disease (p = 0.0156) and more often had a stapled anastomosis (p = 0.002). The overall SSI rate was 14 of 78 (18%). All SSIs occurred in the PC group (14 of 61 vs. 0 of 17, p = 0.03). Conclusions Our study suggests that a skin-approximating closure with a subcuticular purse-string of the stoma site leads to less SSI than a primary closure. Randomized studies are needed to confirm our findings and assess additional end points such as healing time, cost, and patient satisfaction.