947 resultados para SURGICAL DIFFICULTY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Atraumatic teeth extractions protocols are highly encouraged in patients taking bisphosphonates (Bps) to reduce surgical trauma and, consequently, the risk of jaws osteonecrosis development. In this way, this paper aims to report the findings of increased surgical difficulty during simple exodontias in animals treated with bisphosphonates.Methods: Sixty male Holtzman rats were randomly distributed into three groups of 20 animals and received daily subcutaneous administration of 1 mg/kg (AL1) or 3 mg/kg (AL3) of alendronate or saline solution (CTL). After 60 days of drug therapy all animals were submitted to first lower molars extractions under general anesthesia. Operatory surgical time and the frequency of teeth fractures were measured as principal outcomes and indicators of surgical difficulty degree.Results: Animals treated with alendronate (AL1 and AL3) were associated to higher operatory times and increased frequency of teeth fractures compared to match controls.Conclusions: The bisphosphonate therapy may be associated with an increased surgical difficulty and trauma following simple exodontias protocols, which is considered a critical issue when it comes to osteonecrosis development.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives. This study recorded and evaluated the intra-and inter-group agreement degree by different examiners for the classification of lower third molars according to both the Winter's and Pell & Gregory's systems. Study Design. An observational and cross-sectional study was realized with forty lower third molars analyzed from twenty digital panoramic radiographs. Four examiner groups (undergraduates, maxillofacial surgeons, oral radiologists and clinical dentists) from Aracaju, Sergipe, Brazil, classified them in relation to angulation, class and position. The variance test (ANOVA) was applied in the examiner findings with significance level of p<0.05 and confidence intervals of 95%. Results. Intra- and inter-group agreement was observed in Winter's classification system among all examiners. Pell & Gregory's classification system showed an average intra-group agreement and a statistical significant difference to position variable in inter-group analysis with greater disagreement to the clinical dentists group (p<0.05). Conclusions. High reproducibility was associated to Winter's classification, whereas the system proposed by Pell & Gregory did not demonstrate appropriate levels of reliability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. Lower third molar removal provides a clinical model for studying analgesic drugs. The present study's aim was to compare the clinical efficacy of sublingual ketorolac and sublingual piroxicam in managing pain, trismus and swelling after lower third molar extraction in adult volunteers. Study Design. In this double-blinded, randomized, crossover investigation, 47 volunteers received for 4 days ketorolac sublingually (10 mg 4 times daily) and piroxicam sublingually (20 mg once daily) during 2 separate appointments after lower third molar extraction of symmetrically positioned lower third molars. A surgeon evaluated objective parameters (surgery duration, mouth opening, rescue analgesic medication, and facial swelling) and volunteers documented subjective parameters (postoperative pain and global evaluation), comparing postoperative results for a total of 7 days after surgery. The means of the objective and subjective parameters were compared for statistical significance (P < .05). Results. Volunteers reported low pain scores during the postoperative period when treated with either sublingual ketorolac or piroxicam. Also, volunteers ingested similar amounts of analgesic rescue medication (paracetamol) when they received either drug sublingually (P > .05). Additionally, values for mouth openings measured just before surgery and immediately after suture removal 7 days later were similar among volunteers (P > .05), and the type of nonsteroidal antiinflammatory drug (NSAID) used in this study showed no significant differences between swellings on the second or seventh days after surgery (P > .05). Conclusions. Pain, trismus, and swelling after lower third molar extraction, independent of surgical difficulty, were successfully controlled by sublingual ketorolac (10 mg 4 times daily) or sublingual piroxicam (20 mg once daily), and no significant differences were observed between the NSAIDs evaluated. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:27-34)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The perceived difficulty of steps of manual small incision cataract surgery among trainees in rural China was assessed. Design: Cohort study. Participants: Fifty-two trainees at the end of a manual small incision cataract surgery training programme. Methods: Participants rated the difficulty of 14 surgical steps using a 5-point scale, 1 (very easy) to 5 (very difficult). Demographic and professional information was recorded for trainees. Main Outcome Measure: Mean ratings for surgical steps. Results: Questionnaires were completed by 49 trainees (94.2%, median age 38 years, 8 [16.3%] women). Twenty six (53.1%) had performed ≤50 independent cataract surgeries prior to training. Trainees rated cortical aspiration (mean score±standard deviation=3.10±1.14) the most difficult step, followed by wound construction (2.76±1.08), nuclear prolapse into the anterior chamber (2.74±1.23) and lens delivery (2.51±1.08). Draping the surgical field (1.06±0.242), anaesthetic block administration (1.14±0.354) and thermal coagulation (1.18±0.441) were rated easiest. In regression models, the score for cortical aspiration was significantly inversely associated with performing >50 independent manual small incision cataract surgery surgeries during training (P=0.01), but not with age, gender, years of experience in an eye department or total number of cataract surgeries performed prior to training. Conclusions: Cortical aspiration, wound construction and nuclear prolapse pose the greatest challenge for trainees learning manual small incision cataract surgery, and should receive emphasis during training. Number of cases performed is the strongest predictor of perceived difficulty of key steps. © 2013 Royal Australian and New Zealand College of Ophthalmologists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eagle syndrome is symptomatic elongation of the styloid process, or calcification of the stylomandibular ligament. Difficulty with deglutition. phonation. cervical movement. and the sensation of a foreign body in the oropharynx are all symptoms of this syndrome. Its treatment consists of partial removal of the styloid process. leaving it within the range of normality. We describe the technique, report it case, and point Out Sortie of the advantages. such as the simplicity of the procedure, reduced operating time, and lack risks of operative complications. (C) 2008 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

STUDY OBJECTIVE: To develop a new preoperative classification of submucous myomas for evaluating the viability and the degree of difficulty of hysteroscopic myomectomy.DESIGN: Retrospective study (Canadian Task Force classification II-3)SETTING: University teaching hospitals.PATIENTS: Fifty-five patients who underwent hysteroscopic resection of submucous myomas.INTERVENTION: the possibility of total resection of the myoma, the operating time, the fluid deficit, and the frequency of any complications were considered. The myomas were classified according to the Classification of the European Society for Gynaecological Endoscopy (ESGE) and by our group's new classification (NC), which considers not only the degree of penetration of the myoma into the myometrium, but also adds in such parameters as the distance of the base of the myoma from the uterine wall, the size of the nodule (cm), and the topography of the uterine cavity. The Fisher's exact test, the Student's t test, and the analysis of variance test were used in the statistical analysis. A p value less than .05 in the two-tailed test was considered significant.MEASUREMENTS AND MAIN RESULTS: In 57 myomas, hysteroscopic surgery was considered complete. There was no significant difference among the three ESGE levels (0, 1, and 2). Using the NC, the difference between the numbers of complete surgeries was significant (p < .001) for the two levels (groups I and H). The difference between the operating times was significant for the two classifications. With respect to the fluid deficit, only the NC showed significant differences between the levels (p = .02).CONCLUSIONS: We believe that the NC gives more clues as to the difficulties of a hysteroscopic myomectomy than the standard ESGE classification. It should be stressed that the number of hysteroscopic myomectomies used in this analysis was low, and it would be interesting to evaluate the performance of the classification in a larger number of patients. (c) 2005 AAGL. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Autogenous iliac crest has long served as the gold standard for anterior lumbar arthrodesis although added morbidity results from the bone graft harvest. Therefore, femoral ring allograft, or cages, have been used to decrease the morbidity of iliac crest bone harvesting. More recently, an experimental study in the animal showed that harvesting local bone from the anterior vertebral body and replacing the void by a radio-opaque beta-tricalcium phosphate plug was a valid concept. However, such a concept precludes theoretically the use of posterior pedicle screw fixation. At one institution a consecutive series of 21 patients underwent single- or multiple-level circumferential lumbar fusion with anterior cages and posterior pedicle screws. All cages were filled with cancellous bone harvested from the adjacent vertebral body, and the vertebral body defect was filled with a beta-tricalcium phosphate plug. The indications for surgery were failed conservative treatment of a lumbar degenerative disc disease or spondylolisthesis. The purpose of this study, therefore, was to report on the surgical technique, operative feasibility, safety, benefits, and drawbacks of this technique with our primary clinical experience. An independent researcher reviewed all data that had been collected prospectively from the onset of the study. The average age of the patients was 39.9 (26-57) years. Bone grafts were successfully harvested from 28 vertebral bodies in all but one patient whose anterior procedure was aborted due to difficulty in freeing the left common iliac vein. This case was converted to a transforaminal interbody fusion (TLIF). There was no major vascular injury. Blood loss of the anterior procedure averaged 250 ml (50-350 ml). One tricalcium phosphate bone plug was broken during its insertion, and one endplate was broken because of wrong surgical technique, which did not affect the final outcome. One patient had a right lumbar plexopathy that was not related to this special technique. There was no retrograde ejaculation, infection or pseudoarthrosis. One patient experienced a deep venous thrombosis. At the last follow up (mean 28 months) all patients had a solid lumbar spine fusion. At the 6-month follow up, the pain as assessed on the visual analog scale (VAS) decreased from 6.9 to 4.5 (33% decrease), and the Oswestry disability index (ODI) reduced from 48.0 to 31.7 with a 34% reduction. However, at 2 years follow up there was a trend for increase in the ODI (35) and VAS (5). The data in this study suggest that harvesting a cylinder of autograft from the adjacent vertebral body is safe and efficient. Filling of the void defect with a beta-tricalcium phosphate plug does not preclude the use of posterior pedicle screw stabilization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Residents learning nontechnical skills in Europe face two problems: (1) the difficulty to fit learning time in their overloaded schedules; and (2) the lack of standard pedagogical models for all countries. Online video-based repositories such as WeBSurg or WebOP provide ubiquitous access to surgical contents. However, their pedagogical facets have not been fully exploited and they are often seen as quick-reference repositories rather than full e-learning alternatives. We present a new pedagogically-supported Technology Enhanced Learning (TEL) solution, MISTELA, designed by surgeons, pedagogical experts and engineers. MISTELA aims at building a common European pedagogical model supported by ICT technologies and elearning. The solution proposes a pedagogical model based on a framework for pedagogically-informed design of e-learning platforms. It is composed of (1) an authoring tool for editing and augmenting videos; (2) a media asset management system; and (3) a virtual learning environment. Support of the European Association for Endoscopic Surgery (EAES) and validation of the solution, will help to determine its full potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hospital acquired infections (HAI) are costly but many are avoidable. Evaluating prevention programmes requires data on their costs and benefits. Estimating the actual costs of HAI (a measure of the cost savings due to prevention) is difficult as HAI changes cost by extending patient length of stay, yet, length of stay is a major risk factor for HAI. This endogeneity bias can confound attempts to measure accurately the cost of HAI. We propose a two-stage instrumental variables estimation strategy that explicitly controls for the endogeneity between risk of HAI and length of stay. We find that a 10% reduction in ex ante risk of HAI results in an expected savings of £693 ($US 984).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently the National Patient Safety Agency in the United Kingdom published a report entitled "Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur". A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: As the population ages, more people will be wearing presbyopic vision corrections when driving. However, little is known about the impact of these vision corrections on driving performance. This study aimed to determine the subjective driving difficulties experienced when wearing a range of common presbyopic contact lens and spectacle corrections.----- Methods: A questionnaire was developed and piloted that included a series of items regarding difficulties experienced while driving under daytime and night-time conditions (rated on five-point and seven-point Likert scales). Participants included 255 presbyopic patients recruited through local optometry practices. Participants were categorized into five age-matched groups; including those wearing no vision correction for driving (n = 50), bifocal spectacles (n = 54), progressive spectacles (n = 50), monovision contact lenses (n = 53), and multifocal contact lenses (n = 48).----- Results: Overall, ratings of satisfaction during daytime driving were relatively high for all correction types. However, multifocal contact lens wearers were significantly less satisfied with aspects of their vision during night-time than daytime driving, particularly regarding disturbances from glare and haloes. Progressive spectacle lens wearers noticed more distortion of peripheral vision, whereas bifocal spectacle wearers reported more difficulties with tasks requiring changes of focus and those who wore no optical correction for driving reported problems with intermediate and near tasks. Overall, satisfaction was significantly higher for progressive spectacles than bifocal spectacles for driving.----- Conclusions: Subjective visual experiences of different presbyopic vision corrections when driving vary depending on the vision tasks and lighting level. Eye-care practitioners should be aware of the driving-related difficulties experienced with each vision correction type and the need to select corrective types that match the driving needs of their patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporosis is a disease characterized by low bone mass and micro-architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture. Osteoporosis affects over 200 million people worldwide, with an estimated 1.5 million fractures annually in the United States alone, and with attendant costs exceeding $10 billion dollars per annum. Osteoporosis reduces bone density through a series of structural changes to the honeycomb-like trabecular bone structure (micro-structure). The reduced bone density, coupled with the microstructural changes, results in significant loss of bone strength and increased fracture risk. Vertebral compression fractures are the most common type of osteoporotic fracture and are associated with pain, increased thoracic curvature, reduced mobility, and difficulty with self care. Surgical interventions, such as kyphoplasty or vertebroplasty, are used to treat osteoporotic vertebral fractures by restoring vertebral stability and alleviating pain. These minimally invasive procedures involve injecting bone cement into the fractured vertebrae. The techniques are still relatively new and while initial results are promising, with the procedures relieving pain in 70-95% of cases, medium-term investigations are now indicating an increased risk of adjacent level fracture following the procedure. With the aging population, understanding and treatment of osteoporosis is an increasingly important public health issue in developed Western countries. The aim of this study was to investigate the biomechanics of spinal osteoporosis and osteoporotic vertebral compression fractures by developing multi-scale computational, Finite Element (FE) models of both healthy and osteoporotic vertebral bodies. The multi-scale approach included the overall vertebral body anatomy, as well as a detailed representation of the internal trabecular microstructure. This novel, multi-scale approach overcame limitations of previous investigations by allowing simultaneous investigation of the mechanics of the trabecular micro-structure as well as overall vertebral body mechanics. The models were used to simulate the progression of osteoporosis, the effect of different loading conditions on vertebral strength and stiffness, and the effects of vertebroplasty on vertebral and trabecular mechanics. The model development process began with the development of an individual trabecular strut model using 3D beam elements, which was used as the building block for lattice-type, structural trabecular bone models, which were in turn incorporated into the vertebral body models. At each stage of model development, model predictions were compared to analytical solutions and in-vitro data from existing literature. The incremental process provided confidence in the predictions of each model before incorporation into the overall vertebral body model. The trabecular bone model, vertebral body model and vertebroplasty models were validated against in-vitro data from a series of compression tests performed using human cadaveric vertebral bodies. Firstly, trabecular bone samples were acquired and morphological parameters for each sample were measured using high resolution micro-computed tomography (CT). Apparent mechanical properties for each sample were then determined using uni-axial compression tests. Bone tissue properties were inversely determined using voxel-based FE models based on the micro-CT data. Specimen specific trabecular bone models were developed and the predicted apparent stiffness and strength were compared to the experimentally measured apparent stiffness and strength of the corresponding specimen. Following the trabecular specimen tests, a series of 12 whole cadaveric vertebrae were then divided into treated and non-treated groups and vertebroplasty performed on the specimens of the treated group. The vertebrae in both groups underwent clinical-CT scanning and destructive uniaxial compression testing. Specimen specific FE vertebral body models were developed and the predicted mechanical response compared to the experimentally measured responses. The validation process demonstrated that the multi-scale FE models comprising a lattice network of beam elements were able to accurately capture the failure mechanics of trabecular bone; and a trabecular core represented with beam elements enclosed in a layer of shell elements to represent the cortical shell was able to adequately represent the failure mechanics of intact vertebral bodies with varying degrees of osteoporosis. Following model development and validation, the models were used to investigate the effects of progressive osteoporosis on vertebral body mechanics and trabecular bone mechanics. These simulations showed that overall failure of the osteoporotic vertebral body is initiated by failure of the trabecular core, and the failure mechanism of the trabeculae varies with the progression of osteoporosis; from tissue yield in healthy trabecular bone, to failure due to instability (buckling) in osteoporotic bone with its thinner trabecular struts. The mechanical response of the vertebral body under load is highly dependent on the ability of the endplates to deform to transmit the load to the underlying trabecular bone. The ability of the endplate to evenly transfer the load through the core diminishes with osteoporosis. Investigation into the effect of different loading conditions on the vertebral body found that, because the trabecular bone structural changes which occur in osteoporosis result in a structure that is highly aligned with the loading direction, the vertebral body is consequently less able to withstand non-uniform loading states such as occurs in forward flexion. Changes in vertebral body loading due to disc degeneration were simulated, but proved to have little effect on osteoporotic vertebra mechanics. Conversely, differences in vertebral body loading between simulated invivo (uniform endplate pressure) and in-vitro conditions (where the vertebral endplates are rigidly cemented) had a dramatic effect on the predicted vertebral mechanics. This investigation suggested that in-vitro loading using bone cement potting of both endplates has major limitations in its ability to represent vertebral body mechanics in-vivo. And lastly, FE investigation into the biomechanical effect of vertebroplasty was performed. The results of this investigation demonstrated that the effect of vertebroplasty on overall vertebra mechanics is strongly governed by the cement distribution achieved within the trabecular core. In agreement with a recent study, the models predicted that vertebroplasty cement distributions which do not form one continuous mass which contacts both endplates have little effect on vertebral body stiffness or strength. In summary, this work presents the development of a novel, multi-scale Finite Element model of the osteoporotic vertebral body, which provides a powerful new tool for investigating the mechanics of osteoporotic vertebral compression fractures at the trabecular bone micro-structural level, and at the vertebral body level.

Relevância:

20.00% 20.00%

Publicador: