183 resultados para SUPINE
Resumo:
Objective: To identify knowledge, attitudes and practices of child health nurses relating to infant wrapping as an effective settling/sleep strategy. Methods: A pre-test/post-test intervention design was used to explore knowledge, attitudes and practices relating to wrapping in a sample of child health nurses (n=182): a) pre-test survey; b) educational intervention incorporating evidence relating to infant wrapping; SIDS&KIDS endorsed infant wrapping pamphlet; Safe Sleeping recommendations. Emphasis was placed on infant wrapping as an effective settling strategy for parents to use as an alternative to prone positioning; c) post-test survey to evaluate intervention effectiveness. Results: Pretest results identified wide variation in nurses’ knowledge, attitudes and practices of infant wrapping as a settling/sleep strategy. The intervention increased awareness of wrapping guidelines and self-reported practices relating to parent advice. Significant positive changes in nurses’ awareness of wrapping guidelines (p<0.001); to wrap in supine position only (p<0.001); and parental advice to use wrapping as an alternative strategy to prone positioning to assist settling/sleep (p<0.01), were achieved post-test. Conclusions: Managing unsettled infants and promoting safe sleeping practices are issues routinely addressed by child health nurses working with parents of young infants. Queensland has a high incidence of prone sleeping. Infant wrapping is an evidence-based strategy to improve settling and promote supine sleep consistent with public health recommendations. Infant wrapping guidelines are now included in Queensland Health’s state policy and Australian SIDSandKids information relating to safe infant sleeping. In communicating complex health messages to parents, health professionals have a key role in reinforcing safe sleeping recommendations and offering safe, effective settling/sleep strategies to address the non-recommended use of prone positioning for unsettled infants.
Resumo:
Introduction Standing radiographs are the ‘gold standard’ for clinical assessment of adolescent idiopathic scoliosis (AIS), with the Cobb Angle used to measure the severity and progression of the scoliotic curve. Supine imaging modalities can provide valuable 3D information on scoliotic anatomy, however, due to changes in gravitational loading direction, the geometry of the spine alters between the supine and standing position which in turn affects the Cobb Angle measurement. Previous studies have consistently reported a 7-10° [1-3] Cobb Angle increase from supine to standing, however, none have reported the effect of endplate pre-selection and which (if any) curve parameters affect the supine to standing Cobb Angle difference. Methods Female AIS patients with right-sided thoracic major curves were included in the retrospective study. Clinically measured Cobb Angles from existing standing coronal radiographs and fulcrum bending radiographs [4] were compared to existing low-dose supine CT scans taken within 3 months of the reference radiograph. Reformatted coronal CT images were used to measure Cobb Angle variability with and without endplate pre-selection (end-plates selected on the radiographs used on the CT images). Inter and intra-observer measurement variability was assessed. Multi-linear regression was used to investigate whether there was a relationship between supine to standing Cobb Angle change and patient characteristics (SPSS, v.21, IBM, USA). Results Fifty-two patients were included, with mean age of 14.6 (SD 1.8) years; all curves were Lenke Type 1 with mean Cobb Angle on supine CT of 42° (SD 6.4°) and 52° (SD 6.7°) on standing radiographs. The mean fulcrum bending Cobb Angle for the group was 22.6° (SD 7.5°). The 10° increase from supine to standing is consistent with existing literature. Pre-selecting vertebral endplates was found to increase the Cobb Angle difference by a mean 2° (range 0-9°). Multi-linear regression revealed a statistically significant relationship between supine to standing Cobb Angle change with: fulcrum flexibility (p=0.001), age (p=0.027) and standing Cobb Angle (p<0.001). In patients with high fulcrum flexibility scores, the supine to standing Cobb Angle change was as great as 20°.The 95% confidence intervals for intra-observer and inter-observer measurement variability were 3.1° and 3.6°, respectively. Conclusion There is a statistically significant relationship between supine to standing Cobb Angle change and fulcrum flexibility. Therefore, this difference can be considered a measure of spinal flexibility. Pre-selecting vertebral endplates causes only minor changes.
Resumo:
Background Supine imaging modalities provide valuable 3D information on scoliotic anatomy, but the altered spine geometry between the supine and standing positions affects the Cobb angle measurement. Previous studies report a mean 7°-10° Cobb angle increase from supine to standing, but none have reported the effect of endplate pre-selection or whether other parameters affect this Cobb angle difference. Methods Cobb angles from existing coronal radiographs were compared to those on existing low-dose CT scans taken within three months of the reference radiograph for a group of females with adolescent idiopathic scoliosis. Reformatted coronal CT images were used to measure supine Cobb angles with and without endplate pre-selection (end-plates selected from the radiographs) by two observers on three separate occasions. Inter and intra-observer measurement variability were assessed. Multi-linear regression was used to investigate whether there was a relationship between supine to standing Cobb angle change and eight variables: patient age, mass, standing Cobb angle, Risser sign, ligament laxity, Lenke type, fulcrum flexibility and time delay between radiograph and CT scan. Results Fifty-two patients with right thoracic Lenke Type 1 curves and mean age 14.6 years (SD 1.8) were included. The mean Cobb angle on standing radiographs was 51.9° (SD 6.7). The mean Cobb angle on supine CT images without pre-selection of endplates was 41.1° (SD 6.4). The mean Cobb angle on supine CT images with endplate pre-selection was 40.5° (SD 6.6). Pre-selecting vertebral endplates increased the mean Cobb change by 0.6° (SD 2.3, range −9° to 6°). When free to do so, observers chose different levels for the end vertebrae in 39% of cases. Multi-linear regression revealed a statistically significant relationship between supine to standing Cobb change and fulcrum flexibility (p = 0.001), age (p = 0.027) and standing Cobb angle (p < 0.001). The 95% confidence intervals for intra-observer and inter-observer measurement variability were 3.1° and 3.6°, respectively. Conclusions Pre-selecting vertebral endplates causes minor changes to the mean supine to standing Cobb change. There is a statistically significant relationship between supine to standing Cobb change and fulcrum flexibility such that this difference can be considered a potential alternative measure of spinal flexibility.
Resumo:
The primary aim of this study was to determine whether endplate pre-selection makes a difference to the Cobb Angle change between supine and standing which is known to occur in idiopathic scoliosis. A secondary aim of this study was to identify which (if any) patient characteristics were correlated with supine versus standing Cobb change. The study found that pre-selecting vertebral endplates causes only has a minor effect on supine to standing Cobb change in scoliosis. There is a statistically significant relationship between supine to standing Cobb Angle change and fulcrum flexibility. Therefore, supine to standing Cobb Angle change can be considered as a measure of spinal flexibility when both standing and supine images are clinically available.
Resumo:
INTRODUCTION Standing radiographs are the ‘gold standard’ for clinical assessment of adolescent idiopathic scoliosis (AIS), with the Cobb Angle used to measure the severity and progression of the scoliotic curve. Supine imaging modalities can provide valuable 3D information on scoliotic anatomy, however, due to changes in gravitational loading direction, the geometry of the spine alters between the supine and standing position which in turn affects the Cobb Angle measurement. Previous studies have consistently reported a 7-10° [1-3] Cobb Angle increase from supine to standing, however, none have reported the effect of endplate pre-selection and which (if any) curve parameters affect the supine to standing Cobb Angle difference. CONCLUSION There is a statistically significant relationship between supine to standing Cobb Angle change and fulcrum flexibility. Therefore, this difference can be considered a measure of spinal flexibility. Pre-selecting vertebral endplates causes only minor changes.
Resumo:
The purpose of this study was to examine the influence of prone and supine position in preterm infants during acute pain of blood collection.
Resumo:
Caffeine users have been encouraged to consume caffeine regularly to maintain their caffeine tolerance and so avoid caffeine’s acute pressor effects. In controlled conditions complete caffeine tolerance to intervention doses of 250 mg develops rapidly following several days of caffeine ingestion, nevertheless, complete tolerance is not evident for lower intervention doses. Similarly complete caffeine tolerance to 250 mg intervention doses has been demonstrated in habitual coffee and tea drinkers’ but for lower intervention doses complete tolerance is not evident. This study investigated a group of habitual caffeine users following their self-determined consumption pattern involving two to six servings daily. Cardiovascular responses following the ingestion of low to moderate amounts caffeine (67, 133 and 200 mg) were compared with placebo in a double-blind, randomised design without caffeine abstinence. Pre-intervention and post-intervention (30 and 60 min) 90 s continuous cardiovascular recordings were obtained with the Finometer in both the supine and upright postures. Participants were 12 healthy habitual coffee and tea drinkers (10 female, mean age 36). Doses of 67 and 133 mg increased systolic pressure in both postures while in the upright posture diastolic pressure and aortic impedance increased while arterial compliance decreased. These vascular changes were larger upright than supine for 133 mg caffeine. Additionally 67 mg caffeine increased dp/dt and indexed peripheral resistance in the upright posture. For 200 mg caffeine there was complete caffeine tolerance. Cardiovascular responses to caffeine appear to be associated with the size of the intervention dose. Habitual tea and coffee drinking does not generate complete tolerance to caffeine as has been previously suggested. Both the type and the extent of caffeine induced cardiovascular changes were influenced by posture.
Resumo:
The muscles deltoid-anterior portion (DA) and pectoralis major-clavicular portion (PMC) were analysed to establish the muscular behavior and intensity patterns, as well to evaluate the connected participation of these muscles during supine and frontal elevation exercises. Twenty-four male volunteers were examined using a 2-channel TECA TE4 electromyograph and Hewlett Packard surface electrodes. Our results showed low levels of activity to PMC in frontal elevation exercises, whereas to DA the levels were very high. In the supine exercise, the action potential levels developed by the PMC were always lower than those presented by DA, however, with action simultaneity. Some suggestions to the use of the tested exercises are presented.
Resumo:
OBJECTIVE: Obstructive sleep apnea is frequent during the acute phase of stroke, and it is associated with poorer outcomes. A well-established relationship between supine sleep and obstructive sleep apnea severity exists in non-stroke patients. This study investigated the frequency of supine sleep and positional obstructive sleep apnea in patients with ischemic or hemorrhagic stroke. METHODS: Patients who suffered their first acute stroke, either ischemic or hemorrhagic, were subjected to a full polysomnography, including the continuous monitoring of sleep positions, during the first night after symptom onset. Obstructive sleep apnea severity was measured using the apnea-hypopnea index, and the NIHSS measured stroke severity. RESULTS: We prospectively studied 66 stroke patients. The mean age was 57.6+/-11.5 years, and the mean body mass index was 26.5+/-4.9. Obstructive sleep apnea (apnea-hypopnea index >= 5) was present in 78.8% of patients, and the mean apnea-hypopnea index was 29.7+/-26.6. The majority of subjects (66.7%) spent the entire sleep time in a supine position, and positional obstructive sleep apnea was clearly present in the other 23.1% of cases. A positive correlation was observed between the NIHSS and sleep time in the supine position (r(s) = 0.5; p<0.001). CONCLUSIONS: Prolonged supine positioning during sleep was highly frequent after stroke, and it was related to stroke severity. Positional sleep apnea was observed in one quarter of stroke patients, which was likely underestimated during the acute phase of stroke. The adequate positioning of patients during sleep during the acute phase of stroke may decrease obstructive respiratory events, regardless of the stroke subtype.
Resumo:
Background: Percutaneous nephrolithotomy (PCNL) can be performed in the prone or in the supine position. Comparisons between the two techniques in obese patients are rare in the current literature. Methods: The records of obese patients (body mass index >30) who underwent PCNL in the prone or complete supine positions were reviewed. All patients had a noncontrast CT before and after the procedure. Stones were graded according to the Guy stone score and complications according to the Clavien grading. The stone-free rates, operative time, surgical complications, and hospital stay were analyzed. Results: A total of 56 PCNL were performed in 42 patients. Twenty-four PCNL were performed in the prone and 32 in the total supine position. Stone-free rate on the first postoperative day was 50% in the prone and 46.9% in the supine position (P = 1.0). Final stone-free rates were 83.3% and 78.1%, respectively (P = 0.74). Mean operative time was 164.6 minutes in the prone and 120.3 minutes in the supine position (P = 0.0017), and hospital stay was 4.38 and 2.68 days (P = 0.014), respectively. The transfusion rate was 20.8% in the prone and zero in the supine position patients (P = 0.01). Excluding Guy IV stones, transfusion rate was 8.3% in the prone position (P = 0.1). Significant surgical complications rate was 12.5% in the prone and 3.1% in the supine position (P = 0.302). Conclusion: PCNL performed in the prone or in the complete supine position in obese patients presents similar outcomes. The supine decubitus position has the advantages of a significantly shorter operative time and hospital stay.
Resumo:
The instantaneous response of the collateral circulation to isometric physical exercise in patients with non-occlusive coronary artery disease (CAD) is not known.
Resumo:
The purpose of this retrospective study was to intra-individually compare the image quality of computed radiography (CR) and low-dose linear-slit digital radiography (LSDR) for supine chest radiographs. A total of 90 patients (28 female, 62 male; mean age, 55.1 years) imaged with CR and LSDR within a mean time interval of 2.8 days +/- 3.0 were included in this study. Two independent readers evaluated the image quality of CR and LSDR based on modified European Guidelines for Quality Criteria for chest X-ray. The Wilcoxon test was used to analyse differences between the techniques. The overall image quality of LSDR was significantly better than the quality of CR (9.75 vs 8.16 of a maximum score of 10; p < 0.001). LSDR performed significantly better than CR for delineation of anatomical structures in the mediastinum and the retrocardiac lung (p < 0.001). CR was superior to LSDR for visually sharp delineation of the lung vessels and the thin linear structures in the lungs. We conclude that LSDR yields better image quality and may be more suitable for excluding significant pathological features of the chest in areas with high attenuation compared with CR.
Resumo:
This study investigated the effect of sleep position on breathing patterns of normal full term infants during quiet and active behavioral sleep states. Tidal volume, percent contribution of rib cage to tidal volume, and respiration rate were measured via respiratory inductive plethysmography (RIP) and pneumotachograph (PNT) in ten infants sleeping in supine versus right side-lying. Data was collected immediately following two consecutive feedings. Paired t tests and ANOVA comparisons showed no significant differences between the two postures (p $<$.05) in mean tidal volume (supine, M = 19.16, right side, M = 22.45), percent contribution of rib cage to tidal volume (supine, M = 30.55, right side M = 33.20), or respiration rate (supine, M = 49.13, right side, M = 49.37) during quiet sleep. Comparisons also showed no significant differences between the two postures (p $<$.05) in mean tidal volume (supine, M = 18.89, right side, M = 20.12), percent contribution of rib cage to tidal volume (supine, M = 6.43, right side, M = 6.97) or respiration rate (supine, M = 62.18, right side, M = 61.04) during active sleep. Therefore, no differences were found in the three respiratory variables measured between the supine and right side-lying positions. These findings suggest that infants may be positioned in either sleep position without detriment to respiratory function. This information may benefit occupational therapists and other health professionals involved in the education of parents on infant positioning and their respective advantages. ^
Resumo:
Magnetic Resonance Imaging (MRI) offers a valuable research tool for the assessment of 3D spinal deformity in AIS, however the horizontal patient position imposed by conventional scanners removes the axial compressive loading on the spine which is an important determinant of deformity shape and magnitude in standing scoliosis patients. The objective of this study was to design, construct and test an MRI compatible compression device for research into the effect of axial loading on spinal deformity using supine MRI scans. The compression device was designed and constructed, consisting of a vest worn by the patient, which was attached via straps to a pneumatically actuated footplate. An applied load of 0.5 x bodyweight was remotely controlled by a unit in the scanner operator’s console. The entire device was constructed using non-metallic components for MRI compatibility. The device was evaluated by performing unloaded and loaded supine MRI scans on a series of 10 AIS patients. The study concluded that an MRI compatible compression device had been successfully designed and constructed, providing a research tool for studies into the effect of axial loading on 3D spinal deformity in scoliosis. The 3D axially loaded MR imaging capability developed in this study will allow future research investigations of the effect of axial loading on spinal rotation, and for imaging the response of scoliotic spinal tissues to axial loading.