993 resultados para SPECTROPHOTOMETRIC DETERMINATION


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A flow-injection system is proposed for the spectrophotometric determination of sulphite in white wines. The method involves analyte conversion to SO2, gas diffusion through a Teflon® semi-permeable membrane, collection into an alkaline stream (pH 8), reaction with Malachite green (MG) and monitoring at 620 nm. With a concentric tubular membrane, the system design was simplified. Influence of reagent concentrations, pH of donor and acceptor streams, temperature, timing, surfactant addition and presence of potential interfering species of the wine matrix were investigated. A pronounced (ca. 100%) enhancement in sensitivity was noted by adding cetylpyridinium chloride (CPC). The proposed system is robust and baseline drift is not observed during 4 h operating periods. Only 400 μL of sample and 0.32 mg MG are required per determination. The system handles 30 samples per hour, yielding precise results (r.s.d. < 0.015 for 1.0 - 20.0 mg L-1 SO2) in agreement with those obtained by an alternative procedure.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The concept of sequential injection chromatography (SIC) was exploited to automate the fluorimetric determination of amino acids after pre-column derivatization with ophthaldialdehyde (OPA) in presence of 2-mercaptoethanol (2MCE) using a reverse phase monolithic C(18) stationary phase. The method is low-priced and based on five steps of isocratic elutions. The first step employs the mixture methanol: tetrahydrofuran: 10 mmol L(-1) phosphate buffer (pH 7.2) at the volumetric ratio of 8:1:91; the other steps use methanol: 10 mmol L-1 phosphate buffer (pH 7.2) at volumetric ratios of 20:80, 35:65, SO:SO and 65:35. At a flow rate of 10 mu L s(-1) a 25 mm long-column was able to separate aspartic acid (Asp), glutamic acid (Glu), asparagine (Asn), serine (Ser), glutamine (Gln), glycine (Gly), threonine (Thr), citruline (Ctr), arginine (Arg), alanine (Ala), tyrosine (Tyr), phenylalanine (Phe), ornithine (Orn) and lysine (Lys) with resolution >1.2 as well as methionine (Met) and valine (Val) with resolution of 0.6. Under these conditions isoleucine (Ile) and leucine (Leu) co-eluted. The entire cycle of amino acids derivatization, chromatographic separation and column conditioning at the end of separation lasted 25 min. At a flow rate of 40 mu L s(-1) such time was reduced to 10 min at the cost of resolution worsening for the pairs Ctr/Arg and Orn/Lys. The detection limits varied from 0.092 mu mol L(-1) for Tyr to 0.51 mu mol L(-1) for Orn. The method was successfully applied to the determination of intracellular free amino acids in the green alga Tetraselmis gracilis during a period of seven days of cultivation. Samples spiked with known amounts of amino acids resulted in recoveries between 94 and 112%. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A flow system designed with solenoid valves is proposed for determination of weak acid dissociable cyanide, based on the reaction with o-phthalaldehyde (OPA) and glycine yielding a highly fluorescent isoindole derivative. The proposed procedure minimizes the main drawbacks related to the reference batch procedure, based on reaction with barbituric acid and pyridine followed by spectrophotometric detection, i.e., use of toxic reagents, high reagent consumption and waste generation, low sampling rate, and poor sensitivity. Retention of the sample zone was exploited to increase the conversion rate of the analyte with minimized sample dispersion. Linear response (r=0.999) was observed for cyanide concentrations in the range 1-200 mu g L(-1), with a detection limit (99.7% confidence level) of 0.5 mu g L(-1)(19 nmol L(-1)). The sampling rate and coefficient of variation (n=10) were estimated as 22 measurements per hour and 1.4%, respectively. The results of determination of weak acid dissociable cyanide in natural water samples were in agreement with those achieved by the batch reference procedure at the 95% confidence level. Additionally to the improvement in the analytical features in comparison with those of the flow system with continuous reagent addition (sensitivity and sampling rate 90 and 83% higher, respectively), the consumption of OPA was 230-fold lower.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A new method is presented for spectrophotometric determination of total polyphenols content in wine. The procedure is a modified CUPRAC method based on the reduction of Cu(II), in hydroethanolic medium (pH 7.0) in the presence of neocuproine (2,9-dimethyl-1,10-phenanthroline), by polyphenols, yielding a Cu(I) complexes with maximum absorption peak at 450 nm. The absorbance values are linear (r = 0.998, n = 6) with tannic acid concentrations from 0.4 to 3.6 mu mol L(-1). The limit of detection obtained was 0.41 mu mol L(-1) and relative standard deviation 1.2% (1 mu mol L(-1); n = 8). Recoveries between 80% and 110% (mean value of 95%) were calculated for total polyphenols determination in 14 commercials and 2 synthetic wine samples (with and without sulphite). The proposed procedure is about 1.5 more sensitive than the official Folin-Ciocalteu method. The sensitivities of both methods were compared by the analytical responses of several polyphenols tested in each method. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This work reports the utilization of two methodologies for carbaryl determination in tomatoes. The measurements were carried out using an amperometric biosensor technique based on the inhibition of acetylcholinesterase activity due to carbaryl adsorption and a HPLC procedure. The electrochemical experiments were performed in 0.1 mol L-1 phosphate buffer solutions at pH 7.4 with an incubation time of 8 min. The analytical curve obtained in pure solutions showed excellent linearity in the 5.0 x 10(-5) to 75 x 10(-5) mol L-1 range, with the limit of detection at 0.4 x 10(-3) gL(-1). The application of such a methodology in tomato samples involved solely liquidising the samples, which were spiked with 6.0 x 10(-6) and 5.0 x 10(-5) mol L-1 carbaryl. Recovery in such samples presented values of 99.0 and 92.4%, respectively. In order to obtain a comparison, HPLC experiments were also conducted under similar conditions. However, the tomato samples have to be manipulated by an extraction procedure (MSPD), which yielded much lower recovery values (78.3 and 84.8%, respectively). On the other hand, the detection limit obtained was much lower than that for the biosensor, i.e., 3.2 x 10(-6) g L-1. Finally, the biosensor methodology was employed to analyze carbaryl directly inside the tomato, without any previous manipulation. In this case, the biosensor was immersed in the tomato pulp, which had previously been spiked with the pesticide for 8 min, removed and inserted in the electrochemical cell. A recovery of 83.4% was obtained, showing very low interference of the matrix constituents. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A cathodically pretreated boron-doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry Linear calibration curves (r = 0 999) were obtained from 1 9 x 10(-5) to 2 I x 10(-4) mol L(-1) for AA and from 9 7 x 10(-6) to 1 1 x 10-4 mol L(-1) for CAF. with detection limits of 19 wool L(-1) and 7 0 mu nol L(-1). respectively This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations. with results equal to those obtained using a HPLC reference method

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential Pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials Of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 x 10(-7) mol L(-1) to 8.3 x 10(-7) mol L(-1) for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 x 10(-7) mol L-1 and 3.5 x 10(-8) mol L(-1), respectively. The proposed method Was Successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level). (C) 2008 Elsevier BY. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Although the dominant methods for the determination of urea in clinical applications incorporate selective enzymatic hydrolysis of urea, the determination of urea in soil extracts is complicated by the presence of urease inhibitors. The spectrophotometric determination of urea with an acidic solution diacetyl monoxime and semicarbazide is a viable option but traditional manual procedures are time-consuming. New variations on these procedures, based on microplates or flow-injection analysis methodologies, allow a far greater number of samples to be analysed with high precision and sensitivity.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A portable or field test method for simultaneous spectrophotometric determination of calcium and magnesium in water using multivariate partial least squares (PLS) calibration methods is proposed. The method is based on the reaction between the analytes and methylthymol blue at pH 11. The spectral information was used as the X-block, and the Ca(II) and Mg(II) concentrations obtained by a reference technique (ICP-AES) were used as the Y-block. Two series of analyses were performed, with a month's difference between them. The first series was used as the calibration set and the second one as the validation set. Multivariate statistical process control (MSPC) techniques, based on statistics from principal component models, were used to study the features and evolution with time of the spectral signals. Signal standardization was used to correct the deviations between series. Method validation was performed by comparing the predictions of the PLS model with the reference Ca(II) and Mg(II) concentrations determined by ICP-AES using the joint interval test for the slope and intercept of the regression line with errors in both axes. (C) 1998 John Wiley & Sons, Ltd.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A simple, rapid, and sensitive spectrophotometric method for routine analysis of saccharin in commercial noncaloric sweeteners is proposed. This method is based on the reaction of saccharin with tetrachloro-p-benzoquinone (p-chloranil) accelerated by hydrogen peroxide and conducted in an ethanol:acetone (4:1) medium, producing a violet-red compound (γ max = 550 nm). Beer's law is obeyed in a concentration range of 2.05 × 10 -4 to 3.00 × 10 -3 M with an excellent correlation coefficient (r = 0.9998). The detection limit was 1.55 × 10 -5 M, and the effect of interferences on the spectrophotometric measurements was evaluated. The proposed procedure was applied successfully to the determination of saccharin in noncaloric sweeteners. Recoveries were within 99.2-104.3% with standard deviations ranging from to 0.5-1.6%. Results of the proposed method compare very favorably with those given by the high-performance liquid chromatography method recommended by the Food and Drug Administration.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Este artigo apresenta uma aplicação do método para determinação espectrofotométrica simultânea dos íons divalentes de cobre, manganês e zinco à análise de medicamento polivitamínico/polimineral. O método usa 4-(2-piridilazo) resorcinol (PAR), calibração multivariada e técnicas de seleção de variáveis e foi otimizado o empregando-se o algoritmo das projeções sucessivas (APS) e o algoritmo genético (AG), para escolha dos comprimentos de onda mais informativos para a análise. Com essas técnicas, foi possível construir modelos de calibração por regressão linear múltipla (RLM-APS e RLM-AG). Os resultados obtidos foram comparados com modelos de regressão em componentes principais (PCR) e nos mínimos quadrados parciais (PLS). Demonstra-se a partir do erro médio quadrático de previsão (RMSEP) que os modelos apresentam desempenhos semelhantes ao prever as concentrações dos três analitos no medicamento. Todavia os modelos RLM são mais simples pois requerem um número muito menor de comprimentos de onda e são mais fáceis de interpretar que os baseados em variáveis latentes.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cu(II)/neocuproine (2,9-dimethyl-1,10-phenanthroline) complexes were utilized for spectrophotometric determination of total polyphenol content in beers. This procedure is based on the reduction of Cu(II) by polyphenols in hydroethanolic medium (pH 7.0) in the presence of neocuproine, yielding Cu(I)/complexes with maximum absorption at 454 nm. The sensitivity of the proposed method was compared with the AOAC method using tannic and gallic acid as standards. The average apparent molar absorptivity, in L cm(-1) mol(-1), of tannic acid (3.50 +/- 0.20) x 10(5) and gallic acid (5.12 +/- 0.21) x 10(4), was twice as high for the proposed method. A lower limit of detection (LOD) (2.9 x 10(-1) mg L-1) was found when tannic acid was used in the proposed method. Additionally, less interference from the most common additives in beers was noticed. Total content of polyphenols was analyzed in 17 Brazilian samples. Results ranged from 35.5 to 556 mg L-1 of tannic acid, with higher values for recovery rates (45.4-118%, mean 85.0%) than for gallic acid. Although tannic acid is a mixture of polygalloyl glucoses, the total polyphenol content found in the samples suggests that tannic acid should be used as a standard. This is the first attempt to use this particular copper complex to quantify total polyphenol content in beer samples. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C-18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 mu g L-1 Zn (3 sigma criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 mu g per determination, respectively.