853 resultados para SIGNAL INTENSITY
Resumo:
OBJECTIVE. The objective of our study was to describe the T1 and T2 signal intensity characteristics of papillary renal cell carcinoma (RCC) and clear cell RCC with pathologic correlation. MATERIALS AND METHODS. Of 539 RCCs, 49 tumors (21 papillary RCCs and 28 clear cell RCCs) in 45 patients were examined with MRI. Two radiologists retrospectively and independently assessed each tumor`s T1 and T2 signal intensity qualitatively and quantitatively (i.e., the signal intensity [SI] ratio [tumor SI/renal cortex SI]). Of the 49 tumors, 37 (76%) were assessed for pathology features including tumor architecture and the presence of hemosiderin, ferritin, necrosis, and fibrosis. MRI findings and pathology features were correlated. Statistical methods included summary statistics and Wilcoxon`s rank sum test for signal intensity, contingency tables for assessing reader agreement, concordance rate between the two readers with 95% CIs, and Fisher`s exact test for independence, all stratified by RCC type. RESULTS. Papillary RCCs and clear cell RCCs had a similar appearance and signal intensity ratio on T1-weighted images. On T2-weighted images, most papillary RCCs were hypointense (reader 1, 13/21; reader 2, 14/21), with an average mean signal intensity ratio for both readers of 0.67 +/- 0.2, and none was hyperintense, whereas most clear cell RCCs were hyperintense (reader 1, 21/28; reader 2, 17/28), with an average mean signal intensity ratio for both readers of 1.41 +/- 0.4 (p < 0.05). A tumor T2 signal intensity ratio of <= 0.66 had a specificity of 100% and sensitivity of 54% for papillary RCC. Most T2 hypointense tumors exhibited predominant papillary architecture; most T2 hyperintense tumors had a predominant nested architecture (p < 0.05). CONCLUSION. On T2-weighted images, most papillary RCCs are hypointense and clear cell RCCs, hyperintense. The T2 hypointense appearance of papillary RCCs correlated with a predominant papillary architecture at pathology.
Resumo:
Recently, the spin-echo full-intensity acquired localized (SPECIAL) spectroscopy technique was proposed to unite the advantages of short TEs on the order of milliseconds (ms) with full sensitivity and applied to in vivo rat brain. In the present study, SPECIAL was adapted and optimized for use on a clinical platform at 3T and 7T by combining interleaved water suppression (WS) and outer volume saturation (OVS), optimized sequence timing, and improved shimming using FASTMAP. High-quality single voxel spectra of human brain were acquired at TEs below or equal to 6 ms on a clinical 3T and 7T system for six volunteers. Narrow linewidths (6.6 +/- 0.6 Hz at 3T and 12.1 +/- 1.0 Hz at 7T for water) and the high signal-to-noise ratio (SNR) of the artifact-free spectra enabled the quantification of a neurochemical profile consisting of 18 metabolites with Cramér-Rao lower bounds (CRLBs) below 20% at both field strengths. The enhanced sensitivity and increased spectral resolution at 7T compared to 3T allowed a two-fold reduction in scan time, an increased precision of quantification for 12 metabolites, and the additional quantification of lactate with CRLB below 20%. Improved sensitivity at 7T was also demonstrated by a 1.7-fold increase in average SNR (= peak height/root mean square [RMS]-of-noise) per unit-time.
Resumo:
Purpose: Pulmonary hypoplasia is a determinant parameter for extra-uterine life. In the last years, MRI appears as a complement to US in order to evaluate the degree of pulmonary hypoplasia in foetuses with congenital anomalies, by using different methods - fetal lung volumetry (FLV), lung-to-liver signal intensity ratio (LLSIR)-. But until now, information about the correlation between the MRI prediction and the real postnatal outcome is limited. Methods and materials: We retrospectively reviewed the fetal MRI performed at our Institution in the last 8 years and selected the cases with suspicion of fetal pulmonary hypoplasia (n = 30). The pulmonary volumetry data of these foetuses were collected and the lung-to-liver signal intensity ratio (LLSIR) measures performed. These data were compared with those obtained from a control group of 25 foetuses considered as normal at MRI. The data of the study group were also correlated with the autopsy records or the post-natal clinical information of the patients. Results: As expected, the control group showed higher FLV and LLSIR values than the problem group at all gestational ages. Higher values of FLV and LLSIR were associated with a better post-natal outcome. Sensitivity, specificity, positive and negative predictive values and accuracy for the relative LLSIR and the relative FLV showed no significant differences. Conclusion: Our data show that not only the FLV but also the relative LLSIR inform about the degree of fetal lung development. This information may help to predict the fetal outcome and to evaluate the need for neonatal intensive care.
Resumo:
Mesial temporal lobe epilepsy (MTLE) is associated with hippocampal atrophy and hippocampal signal abnormalities. In our series of familial MTLE (FMTLE), we found a high proportion of hippocampal abnormalities. To quantify signal abnormalities in patients with FMTLE we studied 152 individuals (46 of them asymptomatic) with FMTLE. We used NIH-Image® for volumetry and signal quantification in coronal T1 inversion recovery and T2 for all cross-sections of the hippocampus. Values diverging by 2 or more SD from the control mean were considered abnormal. T2 hippocampal signal abnormalities were found in 52% of all individuals: 54% of affected subjects and 48% of asymptomatic subjects. T1 hippocampal signal changes were found in 34% of all individuals: 42.5% of affected subjects and 15% of asymptomatic subjects. Analysis of the hippocampal head (first three slices) revealed T2 abnormalities in 73% of all individuals (74% of affected subjects and 72% of asymptomatic subjects) and T1 abnormalities in 59% (67% of affected subjects and 41% of asymptomatic subjects). Affected individuals had smaller volumes than controls (P < 0.0001). There was no difference in hippocampal volumes between asymptomatic subjects and controls, although 39% of asymptomatic patients had hippocampal atrophy. Patients with an abnormal hippocampal signal (133 individuals) had smaller ipsilateral volume, but no linear correlation could be determined. Hippocampal signal abnormalities in FMTLE were more frequently found in the hippocampal head in both affected and asymptomatic family members, including those with normal volumes. These results indicate that subtle abnormalities leading to an abnormal hippocampal signal in FMTLE are not necessarily related to seizures and may be determined by genetic factors.
Resumo:
PURPOSE We tested the hypothesis that whiplash trauma leads to changes of the signal intensity of cervical discs in T2-weighted images. METHODS AND MATERIALS 50 whiplash patients (18-65 years) were examined within 48h after motor vehicle accident, and again after 3 and 6 months and compared to 50 age- and sex-matched controls. Signal intensity in ROI's of the discs at the levels C2/3 to C7/T1 and the adjacent vertebral bodies were measured on sagittal T2 weighted MR images and normalized using the average of ROI's in fat tissue. The contrast between discs and both adjacent vertebrae was calculated and disc degeneration was graded by the Pfirrmann-grading system. RESULTS Whiplash trauma did not have a significant effect on the normalized signals from discs and vertebrae, on the contrast between discs and adjacent vertebrae, or on the Pfirrmann grading. However, the contrast between discs and adjacent vertebrae and the Pfirrmann grading showed a strong correlation. In healthy volunteers, the contrast between discs and adjacent vertebrae and Pfirrmann grading increased with age and was dependent on the disc level. CONCLUSION We could not find any trauma related changes of cervical disc signal intensities. Normalized signals of discs and Pfirrmann grading changed with age and varied between disc levels with the used MR sequence.
Resumo:
The aim of this study was to determine the capability of ceMRI based signal intensity (SI) mapping to predict appropriate ICD therapies after PVTSA.
Resumo:
We report results from the analysis of intact polar lipids (IPLs) in sediments from Ocean Drilling Program Sites 1257 and 1258. IPLs, constituting the cell membranes of living organisms, were detected in organic-lean sediments but not in underlying organic-rich black shales. Microbial activity in organic-lean sediments is likely due to sulfate-dependent oxidation of methane whereas difficulties detecting IPLs in black shales are interpreted to result from unfavorable signal-to-noise ratios due to low cell concentrations in combination with extremely high analytical noise created by uncharacterized organic matrix. IPLs found are consistent with a low-diversity community of archaea and bacteria. The concentrations of IPLs are more than one order of magnitude lower than those in Neogene deep subsurface sediments at the Peruvian margin, suggestive of significantly lower cell concentrations in Demerara Rise. This finding is consistent with inferred low rates of subsurface microbial activity.
Resumo:
This paper presents the results of the in-depth study of the Barkhausen effect signal properties for the plastically deformed Fe-2%Si samples. The investigated samples have been deformed by cold rolling up to plastic strain epsilon(p) = 8%. The first approach consisted of time-domain-resolved pulse and frequency analysis of the Barkhausen noise signals whereas the complementary study consisted of the time-resolved pulse count analysis as well as a total pulse count. The latter included determination of time distribution of pulses for different threshold voltage levels as well as the total pulse count as a function of both the amplitude and the duration time of the pulses. The obtained results suggest that the observed increase in the Barkhausen noise signal intensity as a function of deformation level is mainly due to the increase in the number of bigger pulses.
Resumo:
Directional cell growth requires that cells read and interpret shallow chemical gradients, but how the gradient directional information is identified remains elusive. We use single-cell analysis and mathematical modeling to define the cellular gradient decoding network in yeast. Our results demonstrate that the spatial information of the gradient signal is read locally within the polarity site complex using double-positive feedback between the GTPase Cdc42 and trafficking of the receptor Ste2. Spatial decoding critically depends on low Cdc42 activity, which is maintained by the MAPK Fus3 through sequestration of the Cdc42 activator Cdc24. Deregulated Cdc42 or Ste2 trafficking prevents gradient decoding and leads to mis-oriented growth. Our work discovers how a conserved set of components assembles a network integrating signal intensity and directionality to decode the spatial information contained in chemical gradients.
Resumo:
Objective:To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality.Materials and Methods:Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration.Results:As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions.Conclusion:Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.
Resumo:
Using a first-principles theoretical model the adsorption of a methyl radical on different sized silver nanoparticles is compared to the adsorption of the same radical on model surfaces. Calculations of our structural, dynamical and electronic properties indicated that small changes in the local environment will lead to small changes in infrared (IR) wavenumbers, but in dramatic changes in the IR signal. Our calculations indicate the lower the adsorption site coordination, the higher is the signal strength, suggesting that small changes in the electronic charge distribution will result in bigger changes in the polarizability and hence in the spectroscopic signal intensity. This effect explains, among others, the signal magnification observed for nanoparticles in surface enhanced Raman spectroscopic (SERS) experiments.
Resumo:
Changes in metabolism and local circulation occur in the spinal cord during peripheral noxious stimulation. Evidence is presented that this stimulation also causes signal intensity alterations in functional magnetic resonance images of the spinal cord during formalin-induced pain. These results indicate the potential of functional magnetic resonance imaging in assessing noninvasively the extent and intensity of spinal cord excitation in this well characterized pain model. Therefore, the aim of this study was to establish functional magnetic resonance imaging as a noninvasive method to characterize temporal changes in the spinal cord after a single injection of 50 μl of formalin subcutaneously into the hindpaw of the anesthetized rat. This challenge produced a biphasic licking activity in the freely moving conscious animal. Images of the spinal cord were acquired within 2 min, enabling monitoring of the site and the temporal evolution of the signal changes during the development of formalin-induced hyperalgesia without the need of any surgical procedure. The time course of changes in the spinal cord functional image in the isoflurane-anesthetized animal was similar to that obtained from behavioral experiments. Also, comparable physiological data, control experiments, and the inhibition of a response through application of the local anesthetic agent lidocaine indicate that the signal changes observed after formalin injection were specifically related to excitability changes in the relevant segments of the lumbar spinal cord. This approach could be useful to characterize different models of pain and hyperalgesia and, more importantly, to evaluate effects of analgesic drugs.
Resumo:
In magnetic resonance imaging (MRI), the MR signal intensity can vary spatially and this spatial variation is usually referred to as MR intensity nonuniformity. Although the main source of intensity nonuniformity arises from B, inhomogeneity of the coil acting as a receiver and/or transmitter, geometric distortion also alters the MR signal intensity. It is useful on some occasions to have these two different sources be separately measured and analyzed. In this paper, we present a practical method for a detailed measurement of the MR intensity nonuniformity. This method is based on the same three-dimensional geometric phantom that was recently developed for a complete measurement of the geometric distortion in MR systems. In this paper, the contribution to the intensity nonuniformity from the geometric distortion can be estimated and thus, it provides a mechanism for estimation of the intensity nonuniformity that reflects solely the spatial characteristics arising from B-1. Additionally, a comprehensive scheme for characterization of the intensity nonuniformity based on the new measurement method is proposed. To demonstrate the method, the intensity nonuniformity in a 1.5 T Sonata MR system was measured and is used to illustrate the main features of the method. (c) 2005 American Association of Physicists in Medicine.