999 resultados para SF6 technique


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ruminant husbandry is a major source of anthropogenic greenhouse gases (GHG). Filling knowledge gaps and providing expert recommendation are important for defining future research priorities, improving methodologies and establishing science-based GHG mitigation solutions to government and non-governmental organisations, advisory/extension networks, and the ruminant livestock sector. The objectives of this review is to summarize published literature to provide a detailed assessment of the methodologies currently in use for measuring enteric methane (CH4) emission from individual animals under specific conditions, and give recommendations regarding their application. The methods described include respiration chambers and enclosures, sulphur hexafluoride tracer (SF6) technique, and techniques based on short-term measurements of gas concentrations in samples of exhaled air. This includes automated head chambers (e.g. the GreenFeed system), the use of carbon dioxide (CO2) as a marker, and (handheld) laser CH4 detection. Each of the techniques are compared and assessed on their capability and limitations, followed by methodology recommendations. It is concluded that there is no ‘one size fits all’ method for measuring CH4 emission by individual animals. Ultimately, the decision as to which method to use should be based on the experimental objectives and resources available. However, the need for high throughput methodology e.g. for screening large numbers of animals for genomic studies, does not justify the use of methods that are inaccurate. All CH4 measurement techniques are subject to experimental variation and random errors. Many sources of variation must be considered when measuring CH4 concentration in exhaled air samples without a quantitative or at least regular collection rate, or use of a marker to indicate (or adjust) for the proportion of exhaled CH4 sampled. Consideration of the number and timing of measurements relative to diurnal patterns of CH4 emission and respiratory exchange are important, as well as consideration of feeding patterns and associated patterns of rumen fermentation rate and other aspects of animal behaviour. Regardless of the method chosen, appropriate calibrations and recovery tests are required for both method establishment and routine operation. Successful and correct use of methods requires careful attention to detail, rigour, and routine self-assessment of the quality of the data they provide.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study presents the first results from Brazil using SF6 tracer technique adapted from cattle to evaluate the capability of condensed tannin (CT) present in three tropical legume forages, Leucaena leucocephala (LEU), Styzolobium aterrimum (STA), and Mimosa caesalpiniaefolia Benth (MIM) to reduce enteric CH4 production in Santa Ins sheep. Twelve male lambs [27.88 +/- 2.85 kg body weight (BW)] were allocated in individual metabolic cages for 20-day adaptation followed by 6 days for measuring dry matter intake (DMI) and CH4 emission. All lambs received water, mineral supplement, and Cynodon dactylon v. coast-cross hay ad libitum. The treatments consisted of soybean meal (710 g/kg) and ground corn (290 g/kg) [control (CON)]; soybean meal (150 g/kg), ground corn (30 g/kg), and Leucaena hay (820 g/kg) (LEU); soybean meal (160 g/kg), ground corn (150 g/kg), and Mucuna hay (690 g/kg) (STA); and soybean meal (280 g/kg), ground corn (190 g/kg), and Mimosa hay (530 g/kg) (MIM); all calculated to provide 40 g/kg CT (except for CON). DMI (in grams of DMI per kilogram BW per day) was lower for LEU (22.0) than CON (29.3), STA (31.2), and MIM (31.6). The LEU group showed emission of 7.8 g CH4/day, significantly lower than CON (10.5 g CH4/day), STA (10.4 g CH4/day), and MIM (11.3 g CH4/day). However, when the CH4 emission per DMI was considered, there were no significant differences among treatments (0.37, 0.36, 0.33, and 0.35 g CH4/g DMI/kg BW/day, respectively, for CON, LEU, STA, and MIM). The sheep receiving STA had shown a tendency (p = 0.15) to reduce methane emission when compared to the CON group. Therefore, it is suggested that tropical tanniniferous legumes may have potential to reduce CH4 emission in sheep, but more research is warranted to confirm these results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A mathematical model has been developed for predicting the performance of rotating arcs in SF6 gas by considering the energy balance and force balance equations. The finite difference technique has been adopted for the computer simulation of the arc characteristics. This method helps in considering the spatial variation of the transport and radiative properties of the arc. All the three heat loss mechanisms-conduction, convection, and radiation-have been considered. Results obtained over a 10 ms (half cycle of 50 Hz wave) current flow period for 1.4 kA (peak) and 4.2 kA (peak), show that the proposed arc model gives the expected behavior of the arc over the range of currents studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetic resonance imaging of inhaled fluorinated inert gases ((19)F-MRI) such as sulfur hexafluoride (SF(6)) allows for analysis of ventilated air spaces. In this study, the possibility of using this technique to image lung function was assessed. For this, (19)F-MRI of inhaled SF(6) was compared with respiratory gas analysis, which is a global but reliable measure of alveolar gas fraction. Five anesthetized pigs underwent multiple-breath wash-in procedures with a gas mixture of 70% SF(6) and 30% oxygen. Two-dimensional (19)F-MRI and end-expiratory gas fraction analysis were performed after 4 to 24 inhaled breaths. Signal intensity of (19)F-MRI and end-expiratory SF(6) fraction were evaluated with respect to linear correlation and reproducibility. Time constants were estimated by both MRI and respiratory gas analysis data and compared for agreement. A good linear correlation between signal intensity and end-expiratory gas fraction was found (correlation coefficient 0.99+/-0.01). The data were reproducible (standard error of signal intensity 8% vs. that of gas fraction 5%) and the comparison of time constants yielded a sufficient agreement. According to the good linear correlation and the acceptable reproducibility, we suggest the (19)F-MRI to be a valuable tool for quantification of intrapulmonary SF(6) and hence lung function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.