969 resultados para S-phenyl-mercapturic acid determination
Resumo:
Increasing attention is being paid to the use of biomarkers for determining the exposure of humans to air toxics. Biomarkers include the nonreacted toxic substance, their metabolites, or the reaction products of these toxics with naturally substances in the body. Significant progress has been made in the measurement of biomarkers during the past several years. Much of this progress has been because of the development of advanced analytical techniques for identification and quantification of the chemical species in complex matrix, such as biological fluids. The assessment of the potential cancer risk associated with exposure to benzene at occupational and non-occupational ambient is necessary because of the toxicological implications of this air pollutant. Thus, in this review, the analytical methodologies used to determine the benzene metabolites, in special, urinary muconic acid and S-phenylmercapturic acid, are described and several problems affecting the precision of these procedures are discussed. Finally, in view of the difficulty pointed out for selecting the more adequate biomarker, further studies to evaluate the human exposure levels to benzene should be done.
Resumo:
An amperometric sensor was constructed, by using humic acids to immobilize Fe3+ ions on a carbon paste electrode (CPE-HA-Fe), and used for ascorbic acid (H2A) determination. The cyclic voltammogram of the electrode showed electrochemical response due to the Fe3+/Fe2+ couple at E1/2=+0.78 V vs SCE, using 0.5 mol L-1 KCl and 0.2 mol L-1 acetate/0.020 mol L-1 phosphate buffer, at pH = 5.4, as supporting electrolyte. When H2A is added to the electrolyte solution it is observed an oxidation process. The oxidation current, obtained by chronoamperommetry at +0.87 V vs SCE, is proportional to the concentration, represented by the equation I(µA) = 7.6286 [H2A] (mmol L-1) + 1.9583, r = 0.9996, for concentrations between 0.0 and 1.4 mmol L-1. The electrode showed high stability and was used for H2A determination in a natural orange juice.
Resumo:
This work aimed to test if milk preserved with bronopol can be reliably used for fatty acid determination. Dairy production and milk quality are often monitored regularly to assess performance and contribute to selection indices. With evidence that fat composition can be influenced by selective breeding, there might be an interest in using samples collected in routine testing to evaluate individual cow fatty acid profiles, contributing to breeding indices. However, most recording services use a preservative such as bronopol and there is no published record if this influences subsequent fatty acid analysis. This study used milk from an oil seed supplementation trial, generating a wide range of milk fatty acid profiles, to test if the concentration of 31 individual fatty acids determined by GC were influenced by bronopol. Provided preserved samples are subsequently frozen, milk treated with bronopol can reliably be used to evaluate fatty acid composition in most cases; however bronopol might influence a few long-chain fatty acids present in relatively low concentrations. This is one small step towards simplifying milk compositional analysis but it could ultimately streamline the inclusion of milk fat quality into breeding indices, either with a view to 'healthier' milk or potentially reducing methane output and the environmental impact of dairy production.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Glassy carbon electrodes were coated with films of poly( glutamic acid) ( PG), and the modified electrode proved to be very effective in the oxidation of caffeic acid. The performance of the film was also tested with ascorbic acid, coumaric acid, ferulic acid, sinapic acid and chlorogenic acid. At pH 5.6, all the hydroxycinnamic acids yield a higher peak current intensity when oxidized after incorporation in the PG-modified electrode, and only the oxidation of ascorbic acid exhibits overpotential reduction. At pH 3.5 only caffeic and chlorogenic acid are incorporated in the modified electrode and exhibit a well-defined oxidation wave at +0.51 V and +0.48 V, which is the base for their determination. Linear calibration graphs were obtained from 9 x 10(-6) mol L-1 to 4 x 10(-5) mol L-1 caffeic acid by linear voltammetric scan and from 4 x 10(-6) mol L-1 to 3 x 10(-5) mol L-1 by square wave voltammetric scan. The method was successfully applied to the determination of caffeic acid in red wine samples without interference from other hydroxycinnamic acids or ascorbic acid.
Resumo:
The enzyme oxalate oxidase, E.C. 1.2.3.4 from Sorghum vulgare seeds (variety BR303) was used to develop a new sensor for oxalate determination without any purification. The sorghum seeds were conditioned in a 0.10 mol I-1 KCl solution. Then, these seeds were put in a stirring bar type enzymic reactor and coupled with an electrode for CO2. This device was introduced into a cell containing 10.0 ml of a 0.10 mol I-1 KCl solution saturated with oxygen. This sensor showed a linear response between 1.0 and 4.0 × 10-3 mol I-1 with a slope of 30 mV per decade of oxalate concentration at 25.0°C. The sensor was stable for one month or 200 determinations. The response time was about 60 s. The Michaelis-Menten constant determined for this enzyme was 1.5 × 10-3 mol I-1.
Resumo:
Introducción. Los pintores de vehículos automotores están expuestos a solventes puros o mezclas de estos, los cuales se han asociado con efectos neurológicos y mutacarcinogénicos. Materiales y Métodos. Se realizó un estudio descriptivo de corte transversal para caracterizar las condiciones de salud y trabajo de individuos expuestos a solventes orgánicos en talleres de lámina y pintura en Bogotá. Se comparó un grupo de expuestos a solventes orgánicos con un grupo no expuestos. Se determinaron concentraciones de benceno, tolueno y xileno (BTX) en aire, se aplicó una encuesta individual y se midieron en orina, los ácidos fenil mercaptúrico, hipúrico, orto-para metilhipúrico como metabolitos de benceno, tolueno y xileno. Los resultados de las mediciones y de la encuesta se correlacionaron para establecer el panorama de exposición. Resultados: hubo diferencias estadísticamente significativas entre la población expuesta y la población no expuesta a solventes (p = 0,00) para los tres metabolitos de BTX. Se encontraron correlaciones positivas entre el tolueno en aire y ácido hipúrico en orina de los expuestos, (Spearman de 0,82) y entre el xileno en aire y el ácido o-metilhipúrico (Spearman de 0,76). Se encontraron valores de ácido hipúrico por encima de los límites permisibles en 11 2 trabajadores y de ácido p-metilhipúrico en 8 de ellos. No hubo valores para ácido fenilmercapturico fuera de límite. Discusión: los pintores de carros se encuentran expuestos a niveles altos de solventes orgánicos en sus sitios de trabajo y no cuentan con condiciones adecuadas de higiene y seguridad industrial para realizar sus labores.
Resumo:
It was found that cinnamic acid can react with potassium permanganate in the acidic medium and produce chemiluminescence, which was greatly enhanced by glyoxal. Under the optimum conditions, the linear range for the determination of cinnamic acid was 1.0×10-8 to 1.0×10-4 mol L-1 with a detection limit of 8.0×10-9 mol L-1, the relative standard deviation was 1.7% for 2.0×10-6 mol L-1 cinnamic acid solution in nine repeated measurements. This method was found to be novel0simple0fast and sensitive, it was successfully applied to the determination of cinnamic acid in human urine. Furthermore, the possible reaction mechanism was also discussed.
Resumo:
A cathodically pretreated boron-doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry Linear calibration curves (r = 0 999) were obtained from 1 9 x 10(-5) to 2 I x 10(-4) mol L(-1) for AA and from 9 7 x 10(-6) to 1 1 x 10-4 mol L(-1) for CAF. with detection limits of 19 wool L(-1) and 7 0 mu nol L(-1). respectively This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations. with results equal to those obtained using a HPLC reference method
Resumo:
The malate dehydrogenase (MDH) and ascorbate oxidase were immobilized independently, onto silanized controlled porous silica and packed in a tygon tube. The reactors were inserted in the flow system, and the malic acid was determined by measurement of NADH produced by enzymatic reaction. The NADH was reoxidized in a wall jet cell that consisted of spectrographic graphite, Ag/AgCl, KCl(sat), and steel needle as work, reference, and counter electrodes, respectively. The current intensities were measured at 390 mV. The malate calibration curve shows a linear range from 5.0 x 10(-6) to 1.0 x 10(-4) molL(-1), the lifetime was 40 analyses, after that a decrease of 20% on the response is observed. Three different citric juices were analyzed and a good correlation between the proposed method and spectrophotometric commercial kit were obtained.
Resumo:
A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 mi of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the S-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
Styrene is used in a variety of chemical industries. Environmental and occupational exposures to styrene occur predominantly through inhalation. The major metabolite of styrene is present in two enantiomeric forms, chiral R- and S- hydroxy-1-phenyl-acetic acid (R-and S-mandelic acid, MA). Thus, the concentration of MA, particularly of its enantiomers, has been used in urine tests to determine whether workers have been exposed to styrene. This study describes a method of analyzing mandelic acid using molecular imprinting techniques and HPLC detection to perform the separation of diastereoisomers of mandelic acid. The molecularly imprinted polymer (MIP) was prepared by non-covalent molecular imprinting using (+) MA, (-) MA or (+) phenylalanine, (-) phenylalanine as templates. Methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) were copolymerized in the presence of the template molecules. The bulk polymerization was carried out at 4ºC under UV radiation. The resulting MIP was grounded into 25~44¼m particles, which were slurry packed into analytical columns. After the template molecules were removed, the MIP-packed columns were found to be effective for the chromatographic resolution of (±)-mandelic acid. This method is simpler and more convenient than other chromatographic methods.
Resumo:
An alternative method for determination of total trans fatty acids expressed as elaidic acid by capillary zone electrophoresis (CZE) under indirect UV detection at 224 nm within an analysis time of 7.5 min was developed. The optimized running electrolyte includes 15.0 mmol L(-1) KH(2)PO(4)/Na(2)HPO(4) buffer (pH similar to 7.0), 4.0 mmol L(-1) SDBS, 8.0 mmol L(-1) Brij35, 45%v/v ACN, 8% methanol, and 1.5% v/v n-octanol. Baseline separation of the critical pair C18-9cis/C18:1-9t: with a resolution higher than 1.5 was achieved using C15:0 as the internal standard. The optimum capillary electrophoresis (CE) conditions for the background electrolyte were established with the aid of Raman spectroscopy and experiments of a 3(2) factorial design. After response factor (R(F)) calculations, the CE method was applied to total trans fatty acid (TTFA) analysis in a hydrogenated vegetable fat (HVF) sample, and compared with the American Oil Chemists` Society (AOCS) official method by gas chromatography (GC). The methods were compared with an independent sample t test, and no significant difference was found between CE and GC methods within the 95% confidence interval for six genuine replicates of TTFA analysis (p-value > 0.05). The CE method was applied to TTFA analysis in a spreadable cheese sample. Satisfactory results were obtained, indicating that the optimized methodology can be used for trans fatty acid determination for these samples.
Resumo:
The content of ascorbic acid was assayed in acerolas harvested in three phases of maturation: green-yellow fruits (I); light red (II) and wine-coloured (III). Phase I and Phase II fruit were packed in aluminium sheets and stoppered flasks and stored in freezer (-10o.C) and in refrigerator (8o.C). Samples of 8 fruits from each experimental condiction were analysed for ascorbic acid determination by 2-chlorophenol indophenol discolouration method. The averages of 1.393,5 mg./100g. for Phase I sample, 1024,9 for Phase II and 756,5 for Phase III fruits, showed a statistically significative linear decreasing of the ascorbic acid content related with the maturation extent Phase I samples stored in freezing showed statitically significative decreasing of that vitamin at 408 hours of storage in both: aluminium sheet and stoppered flask package; in chilling temperature there was significative reduction of ascorbic acid content after 240 and 312 hours, respectively, for fruits packed in aluminium sheet and stopped flasks. Phase Il samples showed significative lost at 72 hours of storage when maintained in freezing temperature either, in aluminium sheet or in stoppered flasks: When stored in chilling temperature showed progressive lost of ascorbic acid in all measuring periods in every package. After 144 hours suffered deterioration suggested by colour changes.