992 resultados para Rotary system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to evaluate the distribution of microorganisms in the root canal system (RCS) and periapical lesions of dogs' teeth after rotary instrumentation and placement of different calcium hydroxide [Ca(OH)2]-based intracanal dressings. MATERIALS AND METHODS: Chronic periapical lesions were experimentally induced in 80 premolar roots of four dogs. Instrumentation was undertaken using the ProFile rotary system and irrigation with 5.25% sodium hypochlorite. The following Ca(OH) 2-based pastes were applied for 21 days: group 1 - Calen (n=18); group 2 - Calen+CPMC (n=20); group 3 - Ca(OH)2 p.a. + anaesthetic solution (n=16) and group 4 - Ca(OH)2 p.a.+ 2% chlorhexidine digluconate (n=18). Eight root canals without endodontic treatment constituted the control group. Histological sections were obtained and stained with Brown & Brenn staining technique to evaluate the presence of microorganisms in the main root canal, ramifications of the apical delta and secondary canals, apical cementoplasts, dentinal tubules, areas of cemental resorption and periapical lesions. The results were analyzed statistically by the Mann-Whitney U test (p<0.05). RESULTS: The control group showed the highest prevalence of microorganisms in all sites evaluated. Gram-positive cocci, bacilli and filaments were the most frequent morphotypes. Similar microbial distribution patterns in the RCS and areas of cementum resorption were observed in all groups (p>0.05). The percentage of RCS sites containing microorganisms in groups 1, 2, 3, 4 and control were: 67.6%, 62.5%, 78.2%, 62.0% and 87.6%, respectively. CONCLUSION: In conclusion, the histomicrobiological analysis showed that the rotary instrumentation and the different calcium hydroxide pastes employed did not effectively eliminate the infection from the RCS and periapical lesions. However, several bacteria seen in the histological sections were probably dead or were inactivated by the biomechanical preparation and calcium hydroxide-based intracanal dressing.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: The aim of the present study was to determine the disinfection of preparations carried out by using the Protaper or MTwo system in canals infected with Enterococcus faecalis. Methods: Twenty-eight distobuccal canals of upper molars were used, in which the canals were sterilized after being enlarged to #20 file and then contaminated with an inoculation of a culture of E. faecalis. After the incubation period, bacterial samples were collected and were seeded on plates for analysis of colony-forming units (CFU)/mL. The teeth were divided into 2 groups according to the rotary system used for instrumentation; 2 noninstrumented teeth served as the control group. Then bacterial samples were collected and were seeded on plates for analysis of CFU/mL again. The data obtained were evaluated by the Wilcoxon and Mann-Whitney U tests. Results: Bacterial reduction was 81.94% and 84.29%, respectively, in Pro Taper and Mtwo systems, and there was no statistically significant difference (P > .05). Conclusions: Both systems, Pro Taper and Mtwo, reduced the amount of bacteria in the mechanical disinfection of the root canal system, demonstrating that they are suitable for this purpose. (J Endod 2010;36:1238-1240)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To evaluate the efficacy of ProTaper Universal rotary retreatment system and the influence of sealer type on the presence of filling debris in the reinstrumented canals viewed in an operative clinical microscope. Forty-five palatal root canals of first molars were filled with gutta-percha and one of the following sealers: G1, EndoFill; G2, AH Plus; G3, Sealapex. The canals were then reinstrumented with ProTaper Universal rotary system. Roots were longitudinally sectioned and examined under an operative clinical microscope (10x), and the amount of filling debris on canal walls was analyzed using the AutoCAD 2004 software. A single operator used a specific software tool to outline the canal area and the filling debris area in each third (cervical, middle, and apical), as well as the total canal area. Data were analyzed by Kruskal-Wallis test and Tukey test at P < 0.05. Sealapex demonstrated significant differences in the average of filling debris area/canal among the 3 thirds. This group revealed that apical third showed more debris than the both cervical and middle third (P < 0.0001). Endofill presented significantly more filling debris than Sealapex in the cervical third (P < 0.05). In the middle (P = 0.12) and apical third (P = 0.10), there were no differences amongst groups. Debris was left in all canal thirds, regardless of the retreatment technique. The greatest differences between techniques and sealers were found in the cervical third. Microsc. Res. Tech. 75:12331236, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the biomechanical preparation of flattened root canals using the following systems: Endo-Eze AET stainless steel oscillatory instruments (Ultradent) and RaCe rotary NiTi instruments (FKG Dentaire). Materials and Methods: Twenty extracted human mandibular incisors were randomly assigned to two groups: Group I Instrumentation with oscillatory Endo-Eze AET files (oscillatory technique); Group 2 - Instrumentation with rotary NiTi RaCe files (rotary technique). The teeth were decoronated, had their apices and coronal openings sealed with sticky wax and were embedded in crystal-clear orthophtalic polyester resin. The roots were sectioned transversally with diamond discs at 10 mm (middle third) and 5 mm (apical third) from the apex and the segments were reassembled for instrumentation. The sections were photographed before and after root canal instrumentation and evaluated with respect to whether the original root canal shape was modified by instrumentation. To evaluate the differences in the root canal shape before and after biomechanical preparation, scores were given regarding the instruments touch on the intracanal walls. Results: In middle third of the root canals instrumented with the rotary system, there was a change in the original canal anatomy (p < 0.05), with formation of a protuberance in the mesiodistal direction. This protuberance did not occur when the oscillatory instrumentation was used. The oscillatory system had better results in the middle and apical thirds as evaluated by Dunn's multiple-comparison test (p > 0.05). Conclusion: Under the tested conditions, Endo-Eze oscillatory system yielded the instrumentation of all flattened oot canal walls, maintaining the canal original shape throughout the biomechanical preparation, and was more effective than RaCe rotary system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effectiveness of manual and rotary instrumentation techniques for removing root fillings after different storage times. Twenty-four canals from palatal roots of human maxillary molars were instrumented and filled with gutta-percha and zinc-oxide eugenol-based sealer (Endofill), and were stored in saline for 6 years. Non-aged control specimens were treated in the same manner and stored for 1 week. All canals were retreated using hand files or ProTaper Universal NiTi rotary system. Radiographs were taken to determine the amount of remaining material in the canals. The roots were vertically split, the halves were examined with a clinical microscope and the obtained images were digitized. The images were evaluated with AutoCAD software and the percentage of residual material was calculated. Data were analyzed with two-way ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) between the manual and rotary techniques for filling material removal regardless the ageing effect on endodontic sealers. When only the age of the filling material was analyzed microscopically, non-aged fillings that remained on the middle third of the canals presented a higher percentage of material remaining (p<0.05) compared to the aged sealers and to the other thirds of the roots. The apical third showed a higher percentage of residual filling material in both radiographic and microscopic analysis when compared to the other root thirds. In conclusion, all canals presented residual filling material after endodontic retreatment procedures. Microscopic analysis was more effective than radiographs for detection of residual filling material.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this study, curved maxillary molar root canals were instrumented with RaCe rotary system to evaluate: 1. the occurrence of canal transportation using a radiographic platform; 2. the action of the instruments on the dentin walls, centering ability and canal enlargement by analysis of digital images; and the percentage of regular dentin surfaces and debris within the canal by histological analysis. Ten mesiobuccal roots of extracted human maxillary molars were embedded in acrylic resin and sectioned at the middle and apical thirds. Root canal shaping was performed using the RaCe rotary system at 250 rpm and 1 Ncm torque. Each instrument set was used five times according to a crowndown technique in the following sequence: 40/0.10, 35/0.08, 25/0.06, 25/0.04, 25/0.02 (working length - WL), 30/0.02 (WL) and 35/0.02 (WL). Each instrument was inserted until resistance was felt and then pulled back, followed by brushing movements towards all canal walls. Each specimen was assessed by three study methods: radiographic platform, digitized image assessment and histological analysis. The radiographic platform showed lack of apical transportation. No statistically significant difference (Wilcoxon test, p>0.05) was found between the middle and apical thirds regarding instrument action on dentin walls, centering ability, area of root canal enlargement, percentage of regular dentin surfaces and debris within the root canal. It may be concluded that RaCe system is a suitable method for the preparation of curved root canals, regarding the maintenance of root canal original path, action on dentin walls, canal enlargement and removal of debris from the root canal lumen.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To evaluate the efficacy of ProTaper Universal rotary retreatment system and the influence of sealer type on the presence of filling debris in the reinstrumented canals viewed in an operative clinical microscope. Forty-five palatal root canals of first molars were filled with gutta-percha and one of the following sealers: G1, EndoFill; G2, AH Plus; G3, Sealapex. The canals were then reinstrumented with ProTaper Universal rotary system. Roots were longitudinally sectioned and examined under an operative clinical microscope (10x), and the amount of filling debris on canal walls was analyzed using the AutoCAD 2004 software. A single operator used a specific software tool to outline the canal area and the filling debris area in each third (cervical, middle, and apical), as well as the total canal area. Data were analyzed by Kruskal-Wallis test and Tukey test at P < 0.05. Sealapex demonstrated significant differences in the average of filling debris area/canal among the 3 thirds. This group revealed that apical third showed more debris than the both cervical and middle third (P < 0.0001). Endofill presented significantly more filling debris than Sealapex in the cervical third (P < 0.05). In the middle (P = 0.12) and apical third (P = 0.10), there were no differences amongst groups. Debris was left in all canal thirds, regardless of the retreatment technique. The greatest differences between techniques and sealers were found in the cervical third. Microsc. Res. Tech. 75:12331236, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar ex vivo a extrusão bacteriana apical após instrumentação mecanizada com sistemas reciprocantes de instrumento único e movimento reciprocante (WaveOne and Reciproc) comparados a um sistema multi-instrumentos (BioRaCe). Quarenta e cinco incisivos inferiores humanos unirradiculares, ovais e de anatomia semelhante foram utilizados. Os dentes foram acessados e seus canais radiculares foram contaminados com uma suspensão de Enterococcus faecalis e incubados por 30 dias possibilitando crescimento bacteriano em biofilme. Os dentes contaminados foram divididos em três grupos com 15 espécimes cada (RE - Reciproc, WO -WaveOne e BR - BioRaCe). Foram utilizados oito dentes para grupos controle de crescimento bacteriano positivo e negativo. As bactérias extruídas apicalmente durante a instrumentação foram coletadas em frascos de vidro contendo 0,9% de NaCl. As amostras microbiológicas foram retiradas dos frascos e incubadas em meio BHI ágar, durante 24 horas. O crescimento bacteriano foi contado e os resultados foram expressos em unidades formadoras de colônia (UFC). Os dados foram analisados pelos testes estatísticos de Wilcoxon e Kruskal-Wallis. Não houve diferença estatisticamente significante no número de UFC entre os dois sistemas reciprocantes (p>0,05). Em contrapartida, o sistema de instrumentos rotatórios mostrou uma quantidade de UFC significativamente maior do que os dois outros grupos (p <0,05). A partir da análise dos resultados e dentro das limitações deste estudo foi possível concluir que todos os sistemas de instrumentação testados extruem bactérias apicalmente. No entanto, ambos os sistemas de instrumento único e movimento reciprocante extruem menos bactérias apicalmente do que o sistema rotatório multi-instrumentos de referência.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The rotary dryer is one of the most used equipments in processing industries. Its automatic control mode of operation is important specially to keep the moisture content of the final product in the desired value. The classical control strategies, like PID (proportional integral derivative) control, are largely used in the industrial sector because of its robustness and because they are easy to be implemented. In this work, a data acquisition system was implemented for monitoring the most relevant process variables, like: both inlet and outlet drying air temperature, dryer rotation, outlet air speed and humidity, and mass of the final product. Openloop tests were realized to identify a mathematical model able to represent the drying process for the rotary system. From this model, a PID controller was tuned using a direct synthesis method, assuming a first order trajectory. The PID controller was implemented in the system in order to control the inlet drying air temperature. By the end, closedloop tests (operating in automatic mode) were realized to observe the controller performance, and, after setting the best tune, experiments were realized using passion fruit seeds as raw material. The experiments realized in closedloop showed a satisfactory performance by the implemented control strategy for the drying air temperature of the rotary system

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare the percentage of gutta-percha (PGP) in mesial root canals of mandibular molars obturated with LC (Lateral Compaction) or SC (Single Cone) ProTaper Universal System techniques at different levels of the root. Mesial root canals of 20 human permanent molars with similar anatomical characteristics were instrumented using the ProTaper Universal rotary system technique until the F2 instrument, with 20 canals filled by SC ProTaper Universal technique and 20 canals by the LC technique. The mesial roots were sectioned transversely to 3, 5, and 7 mm from the root apex. Digital images of specimens were obtained at MIC-D digital microscope in increases of 30 to 35X. The gutta-percha area was measured using ImageTool software. Data were analyzed using two-way ANOVA and Bonferroni test (a = 0.05). The SC technique provided greater PGP than the LC technique in the apical third (3 mm) (P < 0.001). In the other thirds (5 and 7 mm) there was no statistical difference between the two techniques regarding the PGP (P > 0.05). There was no statistically significant difference between thirds of the root canal for both techniques (P > 0.05). It was concluded that SC technique provided greater PGP than the LC technique in the apical third of mesial root canals of mandibular molars. There was no difference between the two techniques regarding the PGP in the cervical and middle thirds. Microsc. Res. Tech. 75:12291232, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cleaning capacity of hybrid and rotary instrumentation techniques in mesial flattened canals of mandibular first molars was evaluated by morphometrical analysis in this study. Twenty human mandibular first molars were randomly assigned into two groups, according to instrumentation technique, as follows: group 1, instrumentation with ProTaper Starter Kit (Dentsply/Maillefer) rotary system; group 2, manual instrumentation using K files (Dentsply/Maillefer) by crown-down technique in middle and apical thirds, cervical preparation with Gates-Glidden #1 and #2 (Dentsply/Maillefer) burs, and to finalise the preparation, ProTaper F2 and F3 rotary files. Serial transverse cross-sections (5 mu m) of the apical third, stained with hematoxylin and eosin, were analysed at 100 x original magnification. The images were submitted to morphometrical analysis with an integration grid to determine the percentage of root canal area with debris. Statiscal analysis (t-Student, P < 0.05) showed significant difference between the techniques (P < 0.05), although neither completely cleaned the root canal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study compared the remaining filling material and working time when removing gutta-percha/AH 26 and Resilon/Epiphany from root filled extracted teeth. The root fillings were removed using chloroform and two different rotary systems (K3 and Liberator files). The amount of residual filling material on the canal walls was imaged and measured using image analyzer software. The group filled with Resilon/Epiphany and retreated with K3 files demonstrated the least residual filling material on the walls (p < 0.05). There was no statistically significant difference between the guttapercha/AH26 and Resilon/Epiphany groups when the Liberator files were used (p > 0.05). In the groups filled with Resilon/Epiphany, the filling was removed faster than groups filled with gutta-percha/AH 26 (p < 0.05). K3 rotary system was faster than Liberator to remove both gutta-percha and Resilon (p < 0.05). Resilon/ Epiphany was effectively removed with K3 or Liberator rotary files.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the residual antibacterial activity of several calcium hydroxide [Ca(OH) 2]-based pastes, placed in root canals of dogs' teeth with induced chronic periapical lesions. Root canals were instrumented with the ProFile rotary system and filled with 4 pastes: G1 (n=16): Ca(OH) 2 paste + anesthetic solution; G2 (n=20): Calen® paste + camphorated pmonochlorophenol (CMCP); G3 (n=18): Calen®; and G4 (n=18): Ca(OH) 2 paste + 2% chlorhexidine digluconate. After 21 days, the pastes were removed with size 60 K-files and placed on Petri plates with agar inoculated with Micrococcus luteus ATCC 9341. Pastes that were not placed into root canals served as control. After pre-diffusion, incubation and optimization, the inhibition zones of bacterial growth were measured and analyzed by Mann-Whitney U test at 5% significance level. All pastes showed residual antibacterial activity. The control samples had larger halos (p<0.05). The mean residual antibacterial activity halos in G1, G2, G3 and G4 were 7.6; 10.4; 17.7 and 21.4 mm, respectively. The zones of bacterial growth of G4 were significantly larger than those of G1 and G2 (p<0.05). In conclusion, regardless of the vehicle and antiseptic, all Ca(OH) 2-based pastes showed different degrees of measurable residual antibacterial activity. Furthermore, unlike CMCP, chlorhexidine increased significantly the antibacterial activity of Ca(OH) 2.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study evaluated by cone-beam computed tomography (CBCT) the apical canal transportation and centralizing ability of different automated systems after root canal preparation. The mesiobuccal canals of maxillary first molars (n=10 per group) were prepared with: GI - reciprocating system with K-Flexofile; GII - reciprocating system with NiTiFlex files; GIII - rotary system with K3 instruments; GIV - rotary system with RaCe instruments. CBCT scans were taken before and after biomechanical preparation up to a #40.02 diameter. Canal transportation was determined by measuring the smallest distance between the inner canal walls and the mesial and distal sides of the root. The centralization ability corresponded to the difference between the measurements from transportation evaluation, using the linear voxel to voxel method of analysis. The mean transportation was 0.06 ± 0.14 mm, with a tendency to deviate to the mesial side of the root (n=22), with no statistically significant difference among the groups (p=0.4153). The mean centralization index was 0.15 ± 0.65 also without statistically significant difference among the groups (p=0.0881). It may be concluded that apical canal transportation and centralization ability were not influenced by the type of mechanical movement and instruments used.