812 resultados para Retest Reliability
Resumo:
The objective was to determine the reliability of isokinetic strength and endurance testing in the ankle joints of patients with intermittent claudication. Twenty-three patients with peripheral artery disease (PAD) and symptoms of intermittent claudication participated in the study. Isokinetic strength and endurance testing of the ankle joint were performed in symptomatic and asymptomatic legs on 3 separate days. Intraclass coefficient correlation of peak torque (PT) and total work (TW) ranged from 0.77 to 0.92 and 0.89 to 0.96, respectively. PT and TW increased significantly and similarly in both legs from day 1 to day 2 (PT: +42 +/- 84% in the symptomatic leg and +33 +/- 51% in the asymptomatic leg, p < 0.05;TW: +38 +/- 26% in the symptomatic leg and +26 +/- 50% in the asymptomatic leg, p < 0.05). In conclusion, isokinetic strength and endurance testing in the ankle joints of patients with PAD presents reliability coefficients ranging from 0.77 to 0.96. However, strength and endurance increased between the first and the other test sessions performed on separate days, suggesting that two test sessions are necessary for the accurate evaluation of strength and endurance in patients with PAD.
Resumo:
The National Institute of Mental Health developed the semi-structured Diagnostic Interview for Genetic Studies (DIGS) for the assessment of major mood and psychotic disorders and their spectrum conditions. The DIGS was translated into French in a collaborative effort of investigators from sites in France and Switzerland. Inter-rater and test-retest reliability of the French version have been established in a clinical sample in Lausanne. Excellent inter-rater reliability was found for schizophrenia, bipolar disorder, major depression, and unipolar schizoaffective disorder while fair inter-rater reliability was demonstrated for bipolar schizoaffective disorder. Using a six-week test-retest interval, reliability for all diagnoses was found to be fair to good with the exception of bipolar schizoaffective disorder. The lower test-retest reliability was the result of a relatively long test-retest interval that favored incomplete symptom recall. In order to increase reliability for lifetime diagnoses in persons not currently affected, best-estimate procedures using additional sources of diagnostic information such as medical records and reports from relatives should supplement DIGS information in family-genetic studies. Within such a procedure, the DIGS appears to be a useful part of data collection for genetic studies on major mood disorders and schizophrenia in French-speaking populations.
Resumo:
BACKGROUND Some controversy remains about the potential applicability of cognitive potentials for evaluating the cerebral activity associated with cognitive capacity. A fundamental requirement is that these neurophysiological parameters show a high level of stability over time. Previous studies have shown that the reliability of diverse parameters of the P3 component (latency and amplitude) ranges between moderate and high. However, few studies have paid attention to the retest reliability of the P3 topography in groups or individuals. Considering that changes in P3 topography have been related to different pathologies and healthy aging, the main objective of this article was to evaluate in a longitudinal study (two sessions) the reliability of P3 topography in a group and at the individual level. RESULTS The correlation between sessions for P3 topography in the grand average of groups was high (r = 0.977, p<0.001). The within-subject correlation values ranged from 0.626 to 0.981 (mean: 0.888). In the between-subjects topography comparisons, the correlation was always lower for comparisons between different subjects than for within-subjects correlations in the first session but not in the second session. CONCLUSIONS The present study shows that P3 topography is highly reliable for group analysis (comprising the same subjects) in different sessions. The results also confirmed that retest reliability for individual P3 maps is suitable for follow-up studies for a particular subject. Moreover, P3 topography appears to be a specific marker considering that the between-subjects correlations were lower than the within-subject correlations. However, P3 topography appears more similar between subjects in the second session, demonstrating that is modulated by experience. Possible clinical applications of all these results are discussed.
Resumo:
Aims and objectives This study aimed to determine the discriminant validity and the test-retest reliability of a questionnaire testing the impact of evidence-based medicine (EBM) training on doctors' knowledge and skills. Methods Questionnaires were sent electronically to all doctors working as residents and chief residents in two French speaking hospital networks in Switzerland. Participants completed the questionnaire twice, within a 4-week interval. The discriminant validity was examined in comparing doctors' performance according to their reported EBM previous training. Proportion of agreement between both sessions of the questionnaire, Cohen's kappa and 'uniform kappa' determined its test-retest reliability. Results The participation rate was 9.8%/7.1% to first/second session. Performance increased according to the level of doctors' previous training in EBM. The observed proportion of agreement between both sessions was over 70% for 14/19 questions, and the 'uniform kappa' was superior to 0.60 for 15/19 questions. Conclusion The discriminant validity and test-retest reliability of the questionnaire were satisfying. The low participation rate did not prevent the study from achieving its aims.
Resumo:
INTRODUCTION: Quantitative sensory testing (QST) is widely used in human research to investigate the integrity of the sensory function in patients with pain of neuropathic origin, or other causes such as low back pain. Reliability of QST has been evaluated on both sides of the face, hands and feet as well as on the trunk (Th3-L3). In order to apply these tests on other body-parts such as the lower lumbar spine, it is important first to establish reliability on healthy individuals. The aim of this study was to investigate intra-rater reliability of thermal QST in healthy adults, on two sites within the L5 dermatome of the lumbar spine and lower extremity. METHODS: Test-retest reliability of thermal QST was determined at the L5-level of the lumbar spine and in the same dermatome on the lower extremity in 30 healthy persons under 40 years of age. Results were analyzed using descriptive statistics and intraclass correlation coefficient (ICC). Values were compared to normative data, using Z-transformation. RESULTS: Mean intraindividual differences were small for cold and warm detection thresholds but larger for pain thresholds. ICC values showed excellent reliability for warm detection and heat pain threshold, good-to-excellent reliability for cold pain threshold and fair-to-excellent reliability for cold detection threshold. ICC had large ranges of confidence interval (95%). CONCLUSION: In healthy adults, thermal QST on the lumbar spine and lower extremity demonstrated fair-to-excellent test-retest reliability.
Resumo:
The semi-structured diagnostic interview for genetic studies (DIGS) was developed to assess major mood and psychotic disorders and their spectrum manifestations in genetic studies. Our research group developed a French version of the DIGS and tested its inter-rater and test-retest reliability in psychiatric patients. In this article, we present estimates of the reliability of substance use and antisocial personality disorders. High kappa coefficients for inter-rater reliability were found for drug and alcohol as well as antisocial personality diagnoses and slightly lower kappas for test-retest reliability. Combined with evidence of the reliability of major mood and psychotic disorders, these findings support the suitability of the DIGS for studies of familial aggregation and comorbidity of psychiatric disorders including substance use and antisocial personality disorders.
Resumo:
In a cross-sectional study conducted four years ago to assess the validity of the Brazilian version of the Eating Attitudes Test-26 (EAT-26) for the identification of abnormal eating behaviors in a population of young females in Southern Brazil, 56 women presented abnormal eating behavior as indicated by the EAT-26 and the Edinburgh Bulimic Investigation Test. They were each matched for age and neighborhood to two normal controls (N = 112) and were re-assessed four years later with the two screening questionnaires plus the Composite International Diagnostic Interview (CIDI). The EAT results were then compared to diagnoses originating from the CIDI. To evaluate the temporal stability of the two screening questionnaires, a test-retest design was applied to estimate kappa coefficients for individual items. Given the prevalence of eating disorders of 6.2%, the CIDI psychiatry interview was applied to 161 women. Of these, 0.6% exhibited anorexia nervosa and 5.6%, bulimia nervosa (10 positive cases). The validity coefficients of the EAT were: 40% sensitivity, 84% specificity, and 14% positive predictive value. Cronbach's coefficient was 0.75. For each EAT item, the kappa index was not higher than 0.344 and the correlation coefficient was lower than 0.488. We conclude that the EAT-26 exhibited low validity coefficients for sensitivity and positive predictive value, and showed a poor temporal stability. It is reasonable to assume that these results were not influenced by the low prevalence of eating disorders in the community. Thus, the results cast doubts on the ability of the EAT-26 test to identify cases of abnormal eating behaviors in this population.
Resumo:
This paper studies the test-retest reliability of distortion product otoacoustic emissions (DPOAE) in newborns in a neonatal intensive care unit.
Resumo:
This paper is a review of a study to measure acoustic impedance of the ear using a Madsen ZO70 bridge model.
Resumo:
The primary objective of this research study is to determine which form of testing, the PEST algorithm or an operator-controlled condition is most accurate and time efficient for administration of the gaze stabilization test
Resumo:
Objectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Recent studies have shown that the nociceptive withdrawal reflex threshold (NWR-T) and the electrical pain threshold (EP-T) are reliable measures in pain-free populations. However, it is necessary to investigate the reliability of these measures in patients with chronic pain in order to translate these techniques from laboratory to clinic. The aims of this study were to determine the test-retest reliability of the NWR-T and EP-T after single and repeated (temporal summation) electrical stimulation in a group of patients with chronic low back pain, and to investigate the association between the NWR-T and the EP-T. To this end, 25 patients with chronic pain participated in three identical sessions, separated by 1 week in average, in which the NWR-T and the EP-T to single and repeated stimulation were measured. Test-retest reliability was assessed using intra-class correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman analysis. The association between the thresholds was assessed using the coefficient of determination (r (2)). The results showed good-to-excellent reliability for both NWR-T and EP-T in all cases, with average ICC values ranging 0.76-0.90 and average CV values ranging 12.0-17.7%. The association between thresholds was better after repeated stimulation than after single stimulation, with average r (2) values of 0.83 and 0.56, respectively. In conclusion, the NWR-T and the EP-T are reliable assessment tools for assessing the sensitivity of spinal nociceptive pathways in patients with chronic pain.
Resumo:
INTRODUCTION AND HYPOTHESIS The prevalence of female stress urinary incontinence is high, and young adults are also affected, including athletes, especially those involved in "high-impact" sports. To date there have been almost no studies testing pelvic floor muscle (PFM) activity during dynamic functional whole body movements. The aim of this study was the description and reliability test of PFM activity and time variables during running. METHODS A prospective cross-sectional study including ten healthy female subjects was designed with the focus on the intra-session test-retest reliability of PFM activity and time variables during running derived from electromyography (EMG) and accelerometry. RESULTS Thirteen variables were identified based on ten steps of each subject: Six EMG variables showed good reliability (ICC 0.906-0.942) and seven time variables did not show good reliability (ICC 0.113-0.731). Time variables (e.g. time difference between heel strike and maximal acceleration of vaginal accelerator) showed low reliability. However, relevant PFM EMG variables during running (e.g., pre-activation, minimal and maximal activity) could be identified and showed good reliability. CONCLUSION Further adaptations regarding measurement methods should be tested to gain better control of the kinetics and kinematics of the EMG probe and accelerometers. To our knowledge this is the first study to test the reliability of PFM activity and time variables during dynamic functional whole body movements. More knowledge of PFM activity and time variables may help to provide a deeper insight into physical strain with high force impacts and important functional reflexive contraction patterns of PFM to maintain or to restore continence.