991 resultados para Resistance values


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the impact and fracture resistance of acrylic resins: a heat-polymerized resin, a high-impact resin and an experimental polymethyl methacrylate with elastomer in different proportions (10, 20, 40 and 60%). 120 specimens were fabricated and submitted to conventional heat-polymerization. For impact test, a Charpy-type impact tester was used. Fracture resistance was assessed with a 3-point bending test by using a mechanical testing machine. Ten specimens were used for each test. Fracture (MPa) and impact resistance values (J.m-1) were submitted to ANOVA - Bonferroni's test - 5% significance level. Materials with higher amount of elastomer had statistically significant differences regarding to impact resistance (p < 0.05). Fracture resistance was superior (p < 0.01) for high-resistance acrylic resin. The increase in elastomer concentration added to polymethyl methacrylate raised the impact resistance and decreased the fracture resistance. Processing the material by injection decreased its resistance to impact and fracture.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: This study evaluated the effect of ferrule preparation (Fp) on the fracture resistance of endodontically treated teeth, restored with composite resin cores with or without glass fiber posts. MATERIAL AND METHODS: Forty-four bovine teeth were sectioned 19 or 17 mm (2 mm ferrule) from the apex, endodontically treated and assigned to four groups (n = 11): Group 1: Fp and post; Group 2: Fp and without post; Group 3: without Fp and with post; Group 4: without Fp and without post. All specimens were restored with composite resin core and metal crown. Specimens were subjected to fracture resistance testing in a universal testing machine at a crosshead speed of 0.5 mm/min. The data were analyzed by two-way ANOVA and Tukey's tests (α=0.05). RESULTS: The mean fracture resistance values were as follows: Group 1: 573.3 N; Group 2: 552.5 N; Group 3: 275.3 N; Group 4: 258.6 N. Significantly higher fracture resistance was found for the groups with Fp (p<0.001). CONCLUSION: There was no statistically significant interaction between the "Fp" and "post" factors (p = 0.954). The ferrule preparation increased the fracture resistance of endodontically treated teeth. However, the use of glass fiber post showed no significant influence on the fracture resistance.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Rapid maxillary expansion (RME) may improve the nasal respiratory pattern This study was performed to evaluate the effect of RME on the nasal cavity by acoustic rhinometry and computed rhinomanometry and to determine nasal and maxillary width by posteroanterior cephalometric radiography, up to 30 months after the orthodontic procedure Methods: Twenty-seven children with oral breathing, ranging in age from 7 to 70 years, and with mixed dentition were selected The children had unior bilateral posterior crossbite involving deciduous canines and the first permanent molars All subjects were submitted to nasofibroscopy, acoustic rhinometry, and computed rhinomanometry and posteroanterior cephalometric radiography at four different tunes, i e, before expansion, immediately, 90 days and 30 months after expansion Results: The mean linear left-to-right nasal cavity lateral prominence and left-to-right jugal ponds cephalometric measures increased considerably after expansion and this increase was maintained throughout the period of evaluation There was an immediate significant decrease in nasal resistance, up to 90 days after RME, but the nasal resistance increased 30 months after the procedure The acoustic rhinometry results did not show any difference in values throughout time Conclusion: RME significantly increased nasal and maxillary width as measured by frontal cephalometry, but the nasal mucosal effects were more subtle Also, the influence of RME on nasal resistance was not stable, and nasal resistance values returned to close to the initial ones after 30 months (Am J Rhinol Allergy 24, 161-165, 2010, doi 10.2500/ajra.2010.24.3440)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: To investigate in vitro the effect of retentive grooves, GIC type and insertion method on the fracture resistance of Class II glass-ionomer cement (GIC) restorations. Methods: Premolars were divided into 12 groups (n=10) according to three variables: retentive grooves [presence (PR) or absence AR)], GICs type [Ketac-Molar (KM), Fuji VIII (F8) and RelyX Luting (RX)], and insertion method [syringe injector (SI) or spoon excavator (SE)]. The specimens were subjected to fracture resistance test. Data were submitted to three-way ANOVA and multiple comparisons were performed using a Tukey test (P < 0.05). Results: Mean fracture resistance values (Kgf) +/- standard deviations (SD) were: KM (PR+SI) 65.66 +/- 2.5; KM (PR+SE) = 62.58 +/- 2.1; KM (AR+SI) = 57.11 +/- 1.9; KM (AR+SE) = 51.94 +/- 2.3; F8 (PR+SI) = 63.05 +/- 2.1; F8 (PR+SE) = 60.12 +/- 2.3; F8 (AR+SI) = 55.11 +/- 1.9; F8(AR+SE)=49.20 +/- 1.6; RX (PR+SI)=50.99 +/- 2.4; RX (PR+SE)=48.81 +/- 2.5; RX (AR+SI)=45.53 +/- 2.6; RX (AR+SE)=41.88 +/- 3.0. Statistically significant differences were observed among all the groups tested (P=0.001). There was significant difference when pooled means for GIC type were compared with retentive grooves (P=0.01) and when pooled means for retentive grooves were compared with insertion method (P=0.01).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Influenced by taxonomic position. For example, bufonids are regarded as exhibiting a permeable skin that seems typical for terrestrial anurans. However, this assumption is supported by information on only four bufonid species; therefore, the enormous ecological diversity of the family remains poorly Investigated. To assess whether variation in R(s) within related bufonids correlates with environmental aridity, we measured area-specific rates of EWL of two Brazilian populations of Rhinella granulosa (previously Bufo granulosus), one from the Atlantic Forest and other from the semi-arid Caatinga, and compared both with the forest species R. ornato. Rhinella granulosa from the Atlantic Forest had higher cutaneous resistance than conspecifics from Caatinga and R. ornata. Rhinella ornato presented the lowest cutaneous resistance values. However, Rs were very close to zero In all three populations. We conclude that enhanced Rs is not part of the suite of traits allowing R. granulosa to exploit the Caatinga, and that variation in R(s) within bufonids may relate to traits other than water conservation. Some Information on microhabitat occupation and ventral skin morphology supports the idea that exceptional abilities for detecting and taking up water may be the key factors enhancing the survival of R. granulosa, and possibly other bufonids, in xeric environments.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

O experimento foi realizado no Departamento de Produção Vegetal da Escola Superior de Agricultura Luiz de Queiroz, ESALQ/USP, Piracicaba, São Paulo, Brasil, utilizando-se as culturas de guaranazeiro (Paullinia cupana Kunth), cafeeiro (Coffea arabica L.), cajueiro (Anacardium occidentale L.), goiabeira (Psidium guajava L.) e seringueira (Hevea brasiliensis Muell. - Arg.). No período de seca (setembro/94) e de chuvas (novembro/94), realizaram-se determinações de resistência estomática (RE) (s cm-1) e transpiração (T) (µg cm-1 s-1) nas diferentes espécies. O delineamento experimental foi em blocos casualizados com cinco repetições. A partir das análises dos dados pode-se concluir: 1. diferenças significativas entre espécies, em termos das variáveis avaliadas no período de deficiência hídrica, com valores decrescentes de resistência estomática e crescente de transpiração na seguinte ordem: guaranazeiro > cafeeiro > cajueiro > goiabeira > seringueira; 2. Nas águas as diferenças entre espécies, para ambas as variáveis, foram menos evidentes, continuando a cultura da seringueira a apresentar menor resistência estomática e maior transpiração dentre as espécies; 3. As culturas de guaraná e café apresentaram maior resistência à perda de água, em relação às demais culturas.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

It is well known that sound absorption and sound transmission properties of open porous materials are highly dependent on their airflow resistance values. Low values of airflow resistance indicate little resistance for air streaming through the porous material and high values are a sign that most of the pores inside the material are closed. The laboratory procedures for measuring airflow resistance have been stan- dardized by several organizations, including ISO and ASTM for both alternate flow and continuous flow. However, practical implementation of these standardized methods could be both complex and expensive. In this work, two indirect alternative measurement procedures were compared against the alternate flow standardized technique. The techniques were tested using three families of eco-friendly sound absorbent materials: recycled polyurethane foams, coconut natural fibres, and recycled polyester fibres. It is found that the values of airflow resistance measured using both alternative methods are very similar. There is also a good correlation between the values obtained through alternative and standardized methods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, an investigation of the electrical and electrochemical properties responsible for the energy storage capability of nanocomposites has been carried out. We demonstrate that, in the case of the V2O5 xerogel and the nanocomposites polypyrrole (Ppy)/V2O5 and polyaniline (PANI)/V2O5, the quadratic logistic equation (QLE) can be used to fit the inverse of the resistance values as a function of the injected charge in non-steady-state conditions. This contributes to a phenomenological understanding of the lithium ion and electron transport. The departure of the experimental curve from the fitting observed for the V2O5 xerogel can be attributed to the trapping sites formed during the lithium electroinsertion, which was observed by electrochemical impedance spectroscopy. The amount of trapping sites was obtained on the basis of the QLE. Similar values used to fit the inverse of the resistance were also used to fit the absorbance changes, which is also associated with the small polaron hopping from the V(IV) to the V(V) sites. On the other hand, there was good agreement between the experimental and the theoretical data when the profile of the inverse of the resistance as a function of the amount of inserted lithium ions of the nanocomposites Ppy/V2O5 and PANI/ V2O5 was concerned. We suggest that the presence of the conducting polymers is responsible for the different electrical profile of the V2O5 xerogel compared with those of the nanocomposites. In the latter case, interactions between the lithium ions and oxygen atoms from V2O5 are shielded, thus decreasing the trapping effect of lithium ions in the V2O5 sites. The different values of the lithium ion diffusion coefficient into these intercalation materials are in agreement with this hypothesis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ambient particles have been consistently associated with adverse health effects, yielding mainly high cardiorespiratory morbidity and mortality. Diesel engines represent a major source of particles in the urban scenario. We aimed to modify the composition of diesel particles, by means of different extraction procedures, to relate changes in chemical profile to corresponding indicators of respiratory toxicity. Male BALB/c mice were nasally instilled with saline, or with diesel particles, treated or not, and assigned to five groups: saline ( SHAM), intact diesel particles (DEP), and diesel particles previously treated with methanol ( METH), hexane ( HEX), or nitric acid (NA). Elemental composition and organic compounds were analyzed. Twenty-four hours after nasal instillation, respiratory parameters were measured and lung tissue was collected for histological analysis. Static elastance was significantly increased in groups DEP and MET in relation to the other groups. HEX and NA were different from DEP but not significantly different from SHAM and METH groups. The difference between dynamic and static elastance was increased in DEP, METH, and NA treatments; HEX was not statistically different from SHAM. DEP and METH groups presented significantly increased upper airways resistance, while DEP, METH, and NA showed higher peripheral airways resistance values. All groups had a higher total resistance than SHAM. DEP, METH, and NA showed significant increased infiltration of polymorphonuclear cells. In conclusion, diesel particles treated with hexane ( HEX) resulted in a respiratory-system profile very similar to that in SHAM group, indicating that hexane treatment attenuates pulmonary inflammation elicited by diesel particles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In standard cylindrical gradient coils consisting of a single layer of wires, a limiting factor in achieving very large magnetic field gradients is the rapid increase in coil resistance with efficiency. This is a particular problem in small-bore scanners, such as those used for MR microscopy. By adopting a multi-layer design in which the coil wires are allowed to spread out into multiple layers wound at increasing radii, a more favourable scaling of resistance with efficiency is achieved, thus allowing the design of more powerful gradient coils with acceptable resistance values. Previously this approach has been applied to the design of unshielded, longitudinal, and transverse gradient coils. Here, the multi-layer approach has been extended to allow the design of actively shielded multi-layer gradient coils, and also to produce coils exhibiting enhanced cooling characteristics. An iterative approach to modelling the steady-state temperature distribution within the coil has also been developed. Results indicate that a good level of screening can be achieved in multi-layer coils, that small versions of such coils can yield higher efficiencies at fixed resistance than conventional two-layer (primary and screen) coils, and that performance improves as the number of layers of increases. Simulations show that by optimising multi-layer coils for cooling it is possible to achieve significantly higher gradient strengths at a fixed maximum operating temperature. A four-layer coil of 8 mm inner diameter has been constructed and used to test the steady-state temperature model. (C) 2003 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In small, cylindrical gradient coils consisting of a single layer of wires, the limiting factor in achieving large magnetic field gradients is the rapid increase in coil resistance with efficiency. This behavior results from the decrease in the maximum usable wire diameter as the number of turns is increased. By adopting a multilayer design in which the coil wires are allowed to spread out into multiple layers wound at increasing radii, a more favorable scaling of resistance with efficiency is achieved, thus allowing the design of more powerful gradient coils with acceptable resistance values. By extending the theory used to design standard cylindrical gradient coils, mathematical expressions have been developed that allow the design of multilayer coils. These expressions have previously been applied to the design of a four-layer z-gradient coil. As a further development, the equations have now been modified to allow the design of multilayer transverse gradient coils. The variation in coil performance with the number of layers employed has been investigated for coils of a size suitable for use in NMR microscopy, and the effect of constructing the coil using wires or cuts in a continuous conducting surface has also been assessed. We find that at fixed resistance a small wire-wound two-layer coil offers an increase in efficiency of a factor of about 1.5 compared with a single-layer coil. In addition, a two-layer coil of 10-mm inner diameter has been designed and built. This coil had an efficiency of 0.41 Tm-1 A(-1), a resistance of 0.96 +/- 0.01 Omega, and an inductance of 22.3 +/- 0.2 muH. The coil produces a gradient that deviates from linearity by less than 5% over a central cylindrical region of interest of height and length 6.2 mm. (C) 2003 Wiley Periodicals, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: When performing the Valsalva maneuver (VM), adults and preadolescents produce the same expiratory resistance values. Objective: To analyze heart rate (HR) in preadolescents performing VM, and propose a new method for selecting expiratory resistance. Method: The maximal expiratory pressure (MEP) was measured in 45 sedentary children aged 9-12 years who subsequently performed VM for 20 s using an expiratory pressure of 60%, 70%, or 80% of MEP. HR was measured before, during, and after VM. These procedures were repeated 30 days later, and the data collected in the sessions (E1, E2) were analyzed and compared in periods before, during (0-10 and 10-20 s), and after VM using nonparametric tests. Results: All 45 participants adequately performed VM in E1 and E2 at 60% of MEP. However, only 38 (84.4%) and 25 (55.5%) of the participants performed the maneuver at 70% and 80% of MEP, respectively. The HR delta measured during 0-10 s and 10-20 s significantly increased as the expiratory effort increased, indicating an effective cardiac autonomic response during VM. However, our findings suggest the VM should not be performed at these intensities. Conclusion: HR increased with all effort intensities tested during VM. However, 60% of MEP was the only level of expiratory resistance that all participants could use to perform VM. Therefore, 60% of MEP may be the optimal expiratory resistance that should be used in clinical practice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Soil compaction is one of the main degradation causes, provoked by inappropriate agricultural practices that override the limitations of the soil physical properties. Preconsolidation pressure and penetration resistance have proved effective as alternative to assess and identify soil compaction. Based on the interpretation of these physico-mechanical parameters, compaction can be prevented with a better adjusted soil management. This study was performed to generate preconsolidation pressure and penetration resistance models for Latososlo Vermelho-Amarelo distrófico (Oxisol) under various managements and uses; and evaluate which of these would lead to degradation or degradation susceptibility. The study was carried out in Curvelo, MG. Two managements and one land use were evaluated: no-tillage, sheep grazing and natural forest. Undisturbed soil samples collected from the 0-5 cm layer were subjected to uniaxial compression and penetration resistance tests. Preconsolidation pressure models for forest and no-tillage soils were not statistically different, demonstrating a low degradation potential in no-tillage systems. Preconsolidation pressure was higher in soil under sheep grazing at all water retention tensions and penetration resistance values were higher than under native forest indicating animal trampling as a potential degradation factor. Neither management presented penetration resistance values above 2 MPa at field capacity moisture. Only under sheep grazing the soil penetrability was near 2 MPa at field capacity and values greater than 2 MPa at 0.2 kg kg-1.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main goal of this paper is to obtain a granular material formulated with Municipal Solid Waste Incinerarion (MSWI) bottom ash (BA) and air pollution control (APC) ash to be used as secondary building material. Previously, an optimum concrete mixture using both MSWI residues as aggregates was formulated. A compromise between the environmental behaviour and the economy of the process was considered. Unconfined compressive strength and abrasion resistance values were measured in order to evaluate the mechanical properties. From these results, the granular mixture was not suited for certain applications owing to the high BA/APC content and low cement percentages used to reduce the costs of the final product. Nevertheless, the leaching test performed showed that the concentrations of all heavy metals were below the limits established by the current Catalan legislation for their reutilization. Therefore, the material studied might be mainly used in embankments, where high mechanical properties are not needed and environmental safety is assured.