972 resultados para Reproducibility of serological tests


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the analysis of 10 batches of L.major-like and L.(V.) braziliensis antigens added or not of a proteases inhibitor evaluated by means of an IgG-ELISA on three consecutive days using positive standard sera from patients with diagnosis of American Leishmaniasis previously tested for the presence of IgG antibodies by means of ELISA. The statistical analysis showed that for L. (V.) braziliensis the PMSF-containing antigen did not show any difference among batches or days of testing; the L.(V.) braziliensis antigen without PMSF showed statistical significance for differences among batches and a two-way ANOVA showed significant differences between antigens. L.major-like antigen prepared with or without PMSF showed differences among batches; all 3 days of testing displayed differences for the PMSF antigen but only for days 1 and 2 for the antigen without inhibitor. A two-way ANOVA showed differences among batches of the antigens but not for antigens with and without the protein inhibitor. According to the statistical analysis the L.major-like antigen added or not of PMSF has shown that it is the choice antigen for mucocutaneous leishmaniasis serology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: An integrative literature review was conducted to synthesize available publications regarding the potential use of serological tests in leprosy programs. We searched the databases Literatura Latino-Americana e do Caribe em Ciências da Saúde, Índice Bibliográfico Espanhol em Ciências da Saúde, Acervo da Biblioteca da Organização Pan-Americana da Saúde, Medical Literature Analysis and Retrieval System Online, Hanseníase, National Library of Medicine, Scopus, Ovid, Cinahl, and Web of Science for articles investigating the use of serological tests for antibodies against phenolic glycolipid-I (PGL-I), ML0405, ML2331, leprosy IDRI diagnostic-1 (LID-1), and natural disaccharide octyl-leprosy IDRI diagnostic-1 (NDO-LID). From an initial pool of 3.514 articles, 40 full-length articles fulfilled our inclusion criteria. Based on these papers, we concluded that these antibodies can be used to assist in diagnosing leprosy, detecting neuritis, monitoring therapeutic efficacy, and monitoring household contacts or at-risk populations in leprosy-endemic areas. Thus, available data suggest that serological tests could contribute substantially to leprosy management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports on the standardization of four serological reactions currently used in human serodiagnosis for the detection of anti-Trypanosoma cruzi antibodies in naturally and experimentally infected dogs. Indirect immunofluorescence test (IFAT) and hemagglutination test (IHAT) were standardized, and complement fixation test (CFT) and direct agglutination test (DAT) were used for diagnostic confirmation. Four hundred and eighty one mongrel dogs that were studied by xenodiagnosis were used: (1) parasitemic dogs of two localities of endemic area (EA) of Santiago del Estero province in Argentina (n = 134); (2) non-parasitemic dogs of the same area (n = 285); (3) dogs experimentally infected with T. cruzi in the patent period (n = 6); (4) non-infected dogs (n = 56) which were born in the city of Buenos Aires (BA), one non-EA for Chagas' disease. For IFAT, parasitemic dogs EA showed 95% of reactive sera. Non parasitemic dogs EA showed 77% of non reactive sera. None sera from BA were reactive for dilutions higher than four. For IHAT, 84% of sera of parasitemic dogs EA showed serological reactivity and among non parasitemic dogs BA, 61% were non reactive, while the remainder showed at most titres of 1/16. The cut-off titres for IFAT and IHAT were 1/16 and 1/32 respectively, and for CFT and DAT 1/1 and 1/128 respectively. Sensitivity for IFAT, IHAT, CF and DAT were 95%, 84%, 97% and 95% respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diagnosis of Neospora caninum infection in dogs is based on serological assays such as the indirect fluorescent antibody test (IFAT) and enzyme-linked immunosorbent assays (ELISA). This study evaluated two serological tests (IFAT and ELISA) for the detection of IgG antibodies to N. caninum in 300 serum samples of dogs through the optimization of cut off titers by using the two-graph receiveroperating characteristic (TG-ROC) curve. In addition, the identification of major cross-reactive antigens with Toxoplasma gondii was investigated by inhibition ELISA and immunoblotting (IB) assays. IFAT and ELISA results showed 74% agreement, with a good negative concordance (P-neg=0.83), but a poor positive concordance (P-pos=0.42). The great majority (86%) of sera with positive concordant results (IFAT+/ELISA+) recognized at least two out of three N. caninum immunodominant antigens, particularly the 29-32 and 35-37 kDa bands. Optimization of cut off titers in IFAT and ELISA was performed considering the reactivity to at least two out of three N. caninum immunodominant antigens as infection markers, obtaining a titer of 50 for IFAT and 200 for ELISA. Seropositivity to N. caninuin was significantly associated with T gondii-seropositive samples, particularly in ELISA (55.4%). Inhibition ELISA curves for N. caninum showed a partial heterologous inhibition, indicating some degree of cross-reactivity between N. caninum and T gondii antigens. Inhibition IB assays showed a moderate heterologous inhibition for N. caninum antigens above 45-50 kDa. These results indicate that ELISA should be used critically when crude tachyzoite antigen preparations are employed, due to possible cross-reactivity with other related parasites as T gondii. Also, the cut off dilution of 1:50 in IFAT showed to be the most appropriated for N. caninum serology in dogs. Therefore, we suggest that N. caninum immunodominant antigens, specially the 17 and 29-32 kDa proteins, should be selected markers in serological assays for canine neosporosis. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Development of vaccines against canine visceral leishmaniasis (CVL) may provide a prophylactic barrier, but antibody response detected by standard diagnostic techniques may not separate vaccinated from naturally infected dogs. Moreover, anti-Leishmania antibody levels in vaccinated dogs may be detectable for months. Accordingly, the aim of the present study was to comparatively evaluate an in-house ELISA with three serological tests officially adopted by the Brazilian Ministry of Health for the diagnosis of CVL in dogs vaccinated with Leishmune®. A total of 18 mongrel dogs were submitted to a complete protocol of the vaccine, monitored and evaluated in 5 times (T0-T4) up to 180 days after T0. Twenty-one days after the first dose (T1), 50% of the dogs were seropositive by the in-house ELISA and 5.5% by IFAT, while by the official ELISA and DPP® CVL rapid test all dogs tested negative. At time T2, 42 days after of the first dose, 100%, 83.3%, 11.1%, and 5.5% of the dogs were seropositive by the in-house ELISA, IFAT, official ELISA kit and the DPP® CVL rapid test, respectively. Ninety days after the first dose (T3), 100%, 83.3%, 72.2% and 33.3% of the dogs were seropositive by the in-house ELISA, official ELISA kit, IFAT, and the DPP® CVL rapid test, respectively. Finally, at time T4, 88.8%, 33.3%, 11.1% and 5.5% of the dogs were seropositive by the in-house ELISA, official ELISA kit, DPP® CVL rapid test and IFAT, respectively. In conclusion, dogs vaccinated with Leishmune® cross-react by an in-house ELISA and by the three official Brazilian serological tests for the diagnosis of canine visceral leishmaniasis up to six months after the first vaccine dose, and may be mistakenly diagnosed and removed. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e.,a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO8.The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Testing problems in diagnosing human T-lymphotropic virus (HTLV) infection, mostly HTLV-II, have been documented in HIV/AIDS patients. Since December 1998, the Immunology Department of Instituto Adolfo Lutz (IAL) offers HTLV-I/II serology to Public Health Units that attend HTLV high-risk individuals. Two thousand, three hundred and twelve serum samples: 1,393 from AIDS Reference Centers (Group I), and 919 from HTLV out-patient clinics (Group II) were sent to IAL for HTLV-I/II antibodies detection. The majority of them were screened by two enzyme immunoassays (EIAs), and confirmed by Western Blot (WB 2.4, Genelabs). Seven different EIA kits were employed during the period, and according to WB results, the best performance was obtained by EIAs that contain HTLV-I and HTLV-II viral lysates and rgp21 as antigens. Neither 1st and 2nd, nor 3rd generation EIA kits were 100% sensitive in detecting truly HTLV-I/II reactive samples. HTLV-I and HTLV-II prevalence rates of 3.3% and 2.5% were detected in Group I, and of 9.6% and 3.6% in Group II, respectively. High percentages of HTLV-seroindeterminate WB sera were detected in both Groups. The algorithm testing to be employed in HTLV high-risk population from São Paulo, Brazil, needs the use of two EIA kits of different formats and compounds as screening, and because of high seroindeterminate WB, may be another confirmatory assay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

While testing 414 sera for the diagnosis of Chagas' disease, the conventional reactions of indirect hemagglutination, indirect immunofluorescence and the immunosorbent assay showed a sensitivity of 95.7%, 100% and 98.2% and a specificity of 98%, 98% and 96.4%, respectively, and an excellent association using Fisher's exact test. Chemiluminescence presented 100% sensitivity and 89.6% specificity, while PCR showed 100% specificity and 1.2% sensitivity. It is believed that the three conventional serological reactions are still adequate for diagnosing Chagas' disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The passive haemagglutination (PHA) test, enzyme-linked immunosorbent assay (ELISA) and the dot enzyme-immunosorbent assay (DOT-ELISA) were used to detect the levels of IgG antibodies against the Fraction 1 (F1) antigen of Yersinia pestis in sera of plague-infected patients from Northeast Brazil. Twenty three selected PHA-positive sera of subjects with bacteriological confirmation of plague were also positive in the DOT-ELISA but only 19 were detected by the conventional ELISA technique. Another group of 186 serum samples from subjects diagnosed as plague-infected by clinical and epidemiological parameters, but PHA-negative, were screened with DOT-ELISA and 11 gave positive results. The specificity of the assays on the serological detection of plague was confirmed in inhibition tests using purified F1 antigen. These results suggest that DOT-ELISA can be an useful, simple and more sensitive alternative for the serodiagnosis of plague in Northeast Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Screening for Chlamydia trachomatis-specific antibodies is valuable in investigating recurrent miscarriage, tubal infertility and extrauterine pregnancy. We compared here the performance of immunofluorescence (IF) to four other commercial tests in detecting IgG antibodies directed against C. trachomatis: two enzyme-linked immunosorbent assays (ELISAs) using the major outer membrane protein (MOMP) as the antigen, commercialised respectively by Medac and R-Biopharm (RB), one ELISA using the chlamydial heat shock protein 60 (cHSP60) as the antigen (Medac), as well as a new automated epifluorescence immunoassay (InoDiag). A total of 405 patients with (n = 251) and without (n = 154) miscarriages were tested by all five tests. The prevalence of C. trachomatis-specific IgG antibodies as determined by the IF, cHSP60-Medac, MOMP-Medac, MOMP-RB and InoDiag was 14.3, 23.2, 14.3, 11.9 and 26.2%, respectively. InoDiag exhibited the highest sensitivity, whereas MOMP-RB showed the best specificity. Cross-reactivity was observed with C. pneumoniae using IF, MOMP-RB and InoDiag, and Parachlamydia acanthamoebae using the cHSP60 ELISA test. No cross-reactivity was observed between C. trachomatis and the other Chlamydiales (Neochlamydia hartmannellae, Waddlia chondrophila and Simkania negevensis). Given its high sensitivity, the new automated epifluorescence immunoassay from InoDiag represents an interesting alternative. The MOMP-based ELISA of R-Biopharm should be preferred for large serological studies, given the high throughput of ELISA and its excellent specificity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective The present study aimed to examine the reproducibility of heart rate (HR) and rating of perceived exertion (RPE) values obtained during different incremental treadmill tests. Equipment and methods Twenty male, recreational, endurance-trained runners (10-km running pace: 10–15 km·h−1) performed, in a counterbalanced order, three continuous incremental exercise tests with different speed increments (0.5 km·h−1, 1 km·h−1 and 2 km·h−1). Thereafter, each participant performed the three tests again, maintaining the same order as before. The reproducibility of the HR and RPE values were analyzed for all protocols during submaximal intensities (8, 10, 12, and 14 km·h−1). In addition, it was examined the reproducibility of maximal HR (HRmax) and peak RPE (RPEpeak). Results The variability of both the HR and RPE values showed a tendency to decrease over the stages during the incremental test and was not or slightly influenced by the incremental test design. The HR at 14 km·h−1 and HRmax presented the highest reproducibility (CV < 2%). In contrast, the submaximal RPE values showed higher variability indices (i.e., CV > 5.0%). In conclusion, the HR values were highly reproducible during the stages of the incremental test, in contrast to the RPE values that presented limited reproducibility.