365 resultados para Removable braces


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The increased interest in orthodontics by adults has led companies to develop new treatment alternatives that use less visible and more aesthetic orthodontic appliances. The aesthetic aligners stand out among the treatment options that attend these expectations. This paper presented some relevant aspects of these devices, as well as two cases treated with Essix MTM (Dentsply) system, in which all aesthetic and functional objectives proposed treatment have been achieved. The results of this study support the idea that, when properly indicated, aesthetic aligners are a viable treatment option within the clinical routine of the orthodontist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD. MATERIAL AND METHODS: Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5% significance level. RESULTS: Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI. CONCLUSIONS: It may be concluded that 0.05% NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Removable partial dentures (RPD) demand specific hygienic cleaning and the combination of brushing with immersion in chemical solutions has been the most recommended method for control of biofilm. However, the effect of the cleansers on metallic components has not been widely investigated. This study evaluated the effect of different cleansers on the surface of RPD. Five disc specimens (12 mm x 3 mm metallic disc centered in a 38 x 18 x 4 mm mould filled with resin) were obtained for each experimental situation: 6 solutions [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) control] and 2 Co-Cr alloys [DeguDent (DD) and VeraPDI (VPDI)] were used for each experimental situation. A 180-day immersion was simulated and the measurements of roughness (Ra, µm) of metal and resin were analyzed using 2-way ANOVA and Tukey’s test. The surface changes and tarnishes were examined with a scanning electronic microscopy (SEM). In addition, energy dispersive x-ray spectrometry (EDS) analysis was carried out at representative areas. Visually, NaOCl and MI specimens presented surface tarnishes. The roughness of materials was not affected by the solutions (p>0.05). SEM images showed that NaOCl and MI provided surface changes. EDS analysis revealed the presence of oxygen for specimens in contact with both MI and NaOCl solutions, which might suggest that the two solutions promoted the oxidation of the surfaces, thus leading to spot corrosion. Within the limitations of this study, it may be concluded that the NaOCl and MI may not be suitable for cleaning of RPD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports the case of a 55-year-old female patient who presented with unsatisfactory temporary crowns in the right mandibular premolars and molars, and a premolar-to-molar fixed partial denture in the left side. The clinical and radiographic examinations revealed a fracture of the left first premolar that was a retainer of the fixed partial denture and required extraction. Initially, the acrylic resin crowns were replaced by new ones, and a provisional RPD was made using acrylic resin and orthodontic wire clasps to resolve the problem arising from the loss of the fixed partial denture. Considering the patient's high esthetic demands, the treatment options for the definitive prosthetic treatment were discussed with her and rehabilitation with implant-supported dentures was proposed because the clinical conditions of the residual alveolar ridge were suitable for implant installation, and the patient's general health was excellent. However, the patient did not agree because she knew of a failed case of implant-retained denture in a diabetic individual and was concerned. The patient was fully informed that implant installation was the best indication for her case, but the arguments were not sufficient to change her decision. The treatment possibilities were presented and the patient opted for a clasp-retained removable partial denture (RPD) associated with the placement of crowns in the pillar teeth. The temporary RPD was replaced by the definitive RPD constructed subsequently. Although RPD was not the first choice, satisfactory esthetic and functional outcomes were achieved, overcaming the patient's expectations. This case report illustrates that the dentist must be prepared to deal with situations where, for reasons that cannot be managed, the patient does not accept the treatment considered as the most indicated for his/her case. Alternatives must be proposed and the functional and esthetic requirements must be fulfilled in the best possible manner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the retention force of T-bar clasps made from commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) alloy by the insertion/removal test simulating 5 years use. Thirty-six frameworks were cast from CP Ti (n=18) and Co-Cr alloy (n=18) with identical prefabricated patterns on refractory casts from a distal extension mandibular hemi-arch segment. The castings were made on a vacuum-pressure machine, under vacuum and argon atmosphere. Each group was subdivided in three, corresponding to 0.25 mm, 0.50 mm and 0.75 mm undercuts, respectively. No polishing procedures were performed to ensure uniformity. The specimens were subjected to an insertion/removal test and data was analyzed statistically to compare CP Ti and Co-Cr alloy in the same undercut (Student's t-test for independent samples) and each material in different undercuts (one-way ANOVA) (p=0.05). Comparisons between materials revealed significant differences (p=0.017) only for the 0.50-mm undercut. No significant differences (p>0.05) were found when comparing the same material for the undercuts. It may be concluded that for different undercuts, both Co-Cr alloy and CP Ti had no significant differences for T-bar clasps; CP Ti showed the lowest retention force values when compared to Co-Cr alloy in each undercut, but with significant difference only for the 0.50-mm undercut; and both materials maintained the retentive capacity during the simulation test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 41-year-old man with cleft palate presented with a wide dehiscence and missing teeth. Six implants had been placed for fabrication of an overdenture, which was unsatisfactory. A bar was waxed and cast for connection to the implants; precision attachments were placed laterally for retention. A fixed partial denture was fabricated, and milled crowns were fabricated at the molar region to provide a guiding plane for insertion of a removable palatal obturator. Good swallowing and speech outcomes were achieved. This technique provided functional and esthetic benefits, enhanced oral hygiene, and improved the psychological condition of the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The double system of support, in which the distal-extension removable partial denture adapts, causes inadequate stress around abutment teeth, increasing the possibility of unequal bone resorption. Several ways to reduce or more adequately distribute the stress between abutment teeth and residual ridges have been reported; however, there are no definitive answers to the problem. The purpose of this study was to analyze, by means of photoelasticity, the most favorable stress distribution using three retainers: T bar, rest, proximal plate, I bar (RPI), and circumferential with mesialized rest. Materials and Methods: Three photoelastic models were made simulating a Kennedy Class II inferior arch. Fifteen dentures with long saddles, five of each design, were adjusted to the photoelastic patterns and submitted first to uniformly distributed load, and then to a load localized on the last artificial tooth. The saddles were then shortened and the tests repeated. The quantitative and qualitative analyses of stress intensity were done manually and by photography, respectively. For intragroup analyses the Wilcoxon test for paired samples was used, while for intergroup analyses Friedman and Wilcoxon tests were used to better identify the differences (p < 0.05). Results: The RPI retainer, followed by the T bar, demonstrated the best distribution of load between teeth and residual ridge. The circumferential retainer caused greater concentration of stress between dental apexes. Stress distribution was influenced by the type of retainer, the length of the saddle, and the manner of load application. Conclusions: The long saddles and the uniformly distributed loads demonstrated better distribution of stress on support structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Resin-bonded extracoronal attachments may be indicated for the abutment teeth of removable partial dentures, especially for anterior teeth when a cingulum rest must be provided. This type of treatment has a series of advantages such as minimal tooth reduction, supragingival margins, favourable stress distribution, and improved aesthetic appearance. Objective: To report a clinical case of oral rehabilitation using a combination of resin-bonded extracoronal attachments joined by a Dolder bar with a removable partial denture. Case report: A 60-year-old male patient with only the canines in the maxillary arch was restored with a combination of resin-bonded extracoronal attachments joined by a Dolder bar and a removable partial denture. Conclusion: Dentures with resin-bonded extracoronal attachments can have a number of advantages over traditional clasp-retained removable partial dentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the association between oral candidiasis in elderly users and nonusers of prosthesis and its predisposing factors. To this end, we performed a cross-sectional study where saliva samples from 48 patients were collected they used prosthesis and 43 patients (control group) who did not use. Among the 91 patients, Candida spp were isolated in 40 (83.3%) who used prosthesis and in 23 (53.5%) in the control group. A statistically significant association was determined between the two groups, the isolation of yeasts and dental prosthesis (p < 0.05, OR = 4.3). The most common etiological agent was Candida albicans (37 isolates), with 23 (62.2%) in the denture group and 14 (37.8%) (control group). Among patients who presented clinical manifestations of oral candidiasis (n = 24), 83.3% (n = 20) belonged to the group that wore dentures, while only 16.7% (n = 4) belonged to the control group. Elderly patients with diabetes had 4.4 times higher estimated risk of developing oral candidiasis when compared with individuals without this condition. There was no statistically significant association between being user prostheses and have diabetes with the onset of candidiasis. No statistically significant association was determined between xerostomia, use of prosthesis and oral candidiasis. The use of prosthetics and poor oral hygiene in elderly patients predisposes to the development of oral candidiasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquesta tesi explora la possibilitat de fer servir enllaços inductius per a una aplicació de l’automòbil on el cablejat entre la centraleta (ECU) i els sensors o detectors és difícil o impossible. S’han proposat dos mètodes: 1) el monitoratge de sensors commutats (dos possibles estats) via acoblament inductiu i 2) la transmissió mitjançant el mateix principi físic de la potència necessària per alimentar els sensors autònoms remots. La detecció d'ocupació i del cinturó de seguretat per a seients desmuntables pot ser implementada amb sistemes sense fils passius basats en circuits ressonants de tipus LC on l'estat dels sensors determina el valor del condensador i, per tant, la freqüència de ressonància. Els canvis en la freqüència són detectats per una bobina situada en el terra del vehicle. S’ha conseguit provar el sistema en un marge entre 0.5 cm i 3 cm. Els experiments s’han dut a terme fent servir un analitzador d’impedàncies connectat a una bobina primària i sensors comercials connectats a un circuit remot. La segona proposta consisteix en transmetre remotament la potència des d’una bobina situada en el terra del vehicle cap a un dispositiu autònom situat en el seient. Aquest dispositiu monitorarà l'estat dels detectors (d'ocupació i de cinturó) i transmetrà les dades mitjançant un transceptor comercial de radiofreqüència o pel mateix enllaç inductiu. S’han avaluat les bobines necessàries per a una freqüència de treball inferior a 150 kHz i s’ha estudiat quin és el regulador de tensió més apropiat per tal d’aconseguir una eficiència global màxima. Quatre tipus de reguladors de tensió s’han analitzat i comparat des del punt de vista de l’eficiència de potència. Els reguladors de tensió de tipus lineal shunt proporcionen una eficiència de potència millor que les altres alternatives, els lineals sèrie i els commutats buck o boost. Les eficiències aconseguides han estat al voltant del 40%, 25% i 10% per les bobines a distàncies 1cm, 1.5cm, i 2cm. Les proves experimentals han mostrat que els sensors autònoms han estat correctament alimentats fins a distàncies de 2.5cm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to determine whether there is any relationship between the presence of removable dentures and squamous cell carcinoma of the anterior two thirds of the tongue in a Portuguese population. A retrospective cross-sectional study was conducted on patients with a biopsy-proven diagnosis of squamous cell carcinoma of the tongue, who were seen and treated at the Department of Head and Neck Surgery of the Portuguese Institute of Oncology 'Francisco Gentil', Lisbon, Portugal, during a 3-year period. Several factors were examined: gender, use of removable dentures, age, location of the lesion, and alcohol and tobacco consumption. One hundred and six cases were selected from the initial 151 cases, with a male:female ratio of 3:1 and the lateral borders being the most commonly affected site. The prevalence in both genders was between the sixth and seventh decade of life. Men were more likely to consume alcohol and tobacco than women, and no relationship was observed between denture use and presence of carcinoma of the tongue. In light of the data obtained, it may be considered that female use of a denture plays an important role, but it cannot be identified as a remarkable etiologic factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antiviral nucleosides are compounds that are used against viruses, such as human immunodeficiency virus (HIV) and hepatitis C virus (HCV). To act as therapeutic agent, the antiviral nucleoside needs to be phosphorylated to nucleotide in the body in three consecutive phosphorylation steps by cellular or viral enzymes. The first phosphorylation to the nucleoside monophosphate is often inefficient and leads to poor antiviral activity. The antiviral efficacy can be improved by applying a prodrug strategy and delivering the antiviral nucleoside directly as its monophosphate. In prodrug strategies of antiviral nucleotides, the negative charges on the phosphate moiety are temporarily masked with protecting groups. Once inside the cell, the protecting groups are removed by enzymatic or chemical processes. Many prodrug strategies apply biodegradable protecting groups, the removal of which is triggered by esterase enzymes. Several studies have, however, demonstrated that the removal rate of the second and subsequent esterase labile protecting groups significantly slows down after the first protecting group is removed due to the negative charge on the phosphodiester intermediate, which disturbs the catalytic site of the enzyme. In this thesis, esterase labile protecting group strategies where the issue of retardation could be avoided were studied. Prodrug candidates of antiviral nucleotides were synthesized and kinetic studies on the chemical and enzymatic stability were carried out. In the synthesized compounds, the second protecting group is cleaved from the monophosphate some other mechanism than esterase triggered activation or the structure of prodrug requires only one protecting group. In addition, esterase labile protecting group which is additionally thermally removable was studied. This protecting group was cleaved from oligomeric phosphodiesters both enzymatically and thermally and seems most attractive of the studied phosphate protecting groups. However, the rate of the thermal removal still is too slow to allow efficient protection of longer oligonucleotides and needs optimization. Key words: antiviral, nucleotide, prodrug, protecting group, biodegradable

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the pattern of maxillary complete denture movement during chewing for free-end removable partial dentures (RPD) wearers, compared to maxillary and mandibular complete denture wearers. Eighteen edentulous participants (group I) and 10 volunteers with bilateral posterior edentulous mandibles (group II) comprised the sample. Measures of mean denture movement and its variability were obtained by a kinesiographic instrument K6-I Diagnostic System, during the mastication of bread and a polysulphide block. Data were analysed using two-way anova (alpha = 0.05). Upper movement during chewing was significantly lower for group II, regardless of the test food. The test food did not influence the vertical or lateral position of the denture bases, but more anterior dislocation was found when polysulphide blocks were chewed. Group II presented lower intra-individual variability for the vertical axis. Vertical displacement was also more precise with bread as a test food. It can be concluded that mandibular free-end RPD wearers show smaller and more precise movements than mandibular complete denture wearers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some studies have evaluated the salivary levels of mutans streptococci (MS) in removable partial denture (RPD) users. Saliva samples (2.0 mL) were obtained from 31 patients in six periods: (T0): immediately before installation of RPD; (T8): 8 days after T0; (T48): 48 days after T0; (T92): 92 days after T0; (T140): 140 days after T0 and (T189): 189 days after T0. The samples were vortexed and serially diluted from 10(-1) to 10(-6) in 0.05 m phosphate buffer (pH 7.4). From each dilution, 0.025 mL was plated on Mitis Salivarius Bacitracin (MSB). The plates were incubated in 5% CO2 at 37 degreesC for 72 h. There was an increase (t -test, P < 0.05) in the number of MS between periods T0 and T48 (mean/s.d., CFU mL(-1) of saliva): T0: 2.26/4.43 x 10(6) and T48: 0.47/1.48 x 10(8) . After this, intensive treatment with CHX was accomplished in 29 patients. Saliva samples were obtained after treatment in four periods: (T24 h): 24 h after T0; (T14): 14 days after T24 h; (T28): 28 days after T24 h, and (T63): 63 days after T24 h. The number of MS in saliva did not decrease (t -test, P > 0.05). A new CHX formulation was applied in 15 patients. Saliva samples were obtained in periods: (T0): before new CHX application; (T24 h): 24 h after T0 and (T82): 82 days after T0. The new CHX reduced MS levels in saliva: (mean/s.d., CFU mL(-1) of saliva): T0: 6.64/8.47 x 10(6) and T24 h: 3.2/4.27 x 10(5) (sign rank, P < 0.05). In conclusion, there was a significant increase in the number of MS in saliva after the installation of RPD. The intensive treatment with a properly formulated CHX was effective in the reduction of MS, between 24 h and 82 days after its application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interim restorations are frequently used in prosthodontic treatments. Many complex situations require the combination of fixed and removable partial prostheses. An appropriate interim restoration design that accurately implements the treatment plan is necessary to prepare the oral cavity for the prostheses, and to contribute to the preservation and health of remaining natural teeth, bone support, and gingival tissues. This report describes a modified technique for construction of interim restorations with a combination of fixed and removable partial prostheses. The technique consists of the construction of a milled fixed prosthesis and removable partial denture with metallic framework for use during extensive treatment, improving masticatory function and esthetics and preserving the periodontal health of supporting structures. This interim restoration can also serve as a template for the definitive restoration, allowing patient and dentist to evaluate appearance and function and helping to ensure the success of the definitive restoration.