998 resultados para Release test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to evaluate possible cytotoxic effects of topical creams and lotions produced with Buriti oil and commercial surfactants on human keratinocytes HaCat and 3T3 embryonic mouse fibroblast cultures. We also aimed to assess the cytotoxicity of the surfactants used to produce the emulsions. The neutral red release (NRR) assay was performed as an in vitro method to evaluate the cytotoxicity of the emulsions in HaCat and 3T3 cell lines and predict potential skin irritation. The Buriti oil emulsions presented low cytotoxicity to the cells at high concentrations and the addition of Vitamin E increased cell viability. Among the surfactant tested, Unitol(R) CE 200F proved to be the most cytotoxic, presenting an IC50 significantly lower than the others. Emulsions formulated with Buriti oil and commercial surfactants could be non irritant to the skin due to their low cytotoxicity, especially when enhanced with vitamin E. When emulsified with Buriti oil, water and Brij 72, Unitol CE200F showed less cytotoxic effects than when tested alone. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Insect bite hypersensitivity (IBH) is an IgE-mediated allergic dermatitis caused by bites of Culicoides and Simulium species, and improved means of diagnosis are required. OBJECTIVES: The cellular antigen simulation test (CAST) with C. nubeculosus and S. vittatum extracts was assessed in a population of IBH-affected and healthy horses. Variations in test results over a one year period and possible cross-reactivity between different insect extracts was studied. METHODS: A total of 314 mature horses were studied using the CAST. Influence of severity of clinical signs, gender and age were evaluated, and 32 horses were tested repeatedly over one year. The kappa reliability test was used to assess agreement of the test results with different insect extracts. RESULTS: Horses with IBH had significantly higher sLT release than controls with C. nubeculosus and S. vittatum. The highest diagnostic sensitivity and specificity levels were attained when using adult C. nubeculosus extracts with the CAST (78% and 97%, respectively), suggesting that most horses with IBH are sensitised against Culicoides allergens. A proportion of IBH-affected horses was found to be sensitised to allergens of Simulium spp. in addition to those of C. nubeculosus. The CAST with C. nubeculosus had positive and negative predictive values > or = 80% for a true prevalence of IBH of 12-52%. In the follow-up study, the proportion of IBH-affected horses with a positive test result ranged from 90% in November to 68% in March. Severity of clinical signs or age did not influence test results significantly. However, IBH-affected males achieved significantly more positive test results than IBH-affected females. CONCLUSIONS: The CAST with adult C. nubeculosus has high specificity and good sensitivity for diagnosis of IBH. Horses with IBH are mainly sensitised to Culicoides allergens, and some horses are additionally also sensitised to allergens in Simulium spp. POTENTIAL RELEVANCE: The CAST is likely to be a useful test for diagnosis of IBH, even allowing the identification of IBH-affected but asymptomatic horses. This test may also help in further characterisation of allergens involved in this condition.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The delivery kinetics of growth factors has been suggested to play an important role in the regeneration of peripheral nerves following axotomy. In this context, we designed a nerve conduit (NC) with adjustable release kinetics of nerve growth factor (NGF). A multi-ply system was designed where NC consisting of a polyelectrolyte alginate/chitosan complex was coated with layers of poly(lactide-co-glycolide) (PLGA) to control the release of embedded NGF. Prior to assessing the in vitro NGF release from NC, various release test media, with and without stabilizers for NGF, were evaluated to ensure adequate quantification of NGF by ELISA. Citrate (pH 5.0) and acetate (pH 5.5) buffered saline solutions containing 0.05% Tween 20 yielded the most reliable results for ELISA active NGF. The in vitro release experiments revealed that the best results in terms of reproducibility and release control were achieved when the NGF was embedded between two PLGA layers and the ends of the NC tightly sealed by the PLGA coatings. The release kinetics could be efficiently adjusted by accommodating NGF at different radial locations within the NC. A sustained release of bioactive NGF in the low nanogram per day range was obtained for at least 15days. In conclusion, the developed multi-ply NGF loaded NC is considered a suitable candidate for future implantation studies to gain insight into the relationship between local growth factor availability and nerve regeneration.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hypothèse: L’impression sur textile d’une formulation de microparticules lipidiques avec un principe actif (éconazole nitrate) permet de conserver ou d’améliorer son activité pharmaceutique ex vivo et in vitro. Méthode: Une formulation de microparticules d’éconazole nitrate (ECN) a été formulée par homogénéisation à haut cisaillement, puis imprimée sur un textile LayaTM par une méthode de sérigraphie. La taille des microparticules, la température de fusion des microparticules sur textile et la teneur en éconazole du tissu ont été déterminées. La stabilité de la formulation a été suivie pendant 4 mois à 25°C avec 65% humidité résiduelle (RH). L’activité in vitro des textiles pharmaceutiques a été mesurée et comparée à la formulation commerciale 1% éconazole nitrate (w/w) sur plusieurs espèces de champignons dont le C. albicans, C. glabrata, C. kefyr, C. luminisitae, T. mentagrophytes et T. rubrum. La thermosensibilité des formulations a été étudiée par des tests de diffusion in vitro en cellules de Franz. L’absorption cutanée de l’éconazole a été évaluée ex vivo sur la peau de cochon. Résultats: Les microparticules d’éconazole avaient des tailles de 3.5±0.1 μm. La température de fusion était de 34.8°C. La thermosensibilité a été déterminée par un relargage deux fois supérieur à 32°C comparés à 22°C sur 6 heures. Les textiles ont présenté une teneur stable pendant 4 mois. Les textiles d’ECN in vitro ont démontré une activité similaire à la formulation commerciale sur toutes ii espèces de Candida testées, ainsi qu’une bonne activité contre les dermatophytes. La diffusion sur peau de cochon a démontré une accumulation supérieure dans le stratum corneum de la formulation textile par rapport à la formulation Pevaryl® à 1% ECN. La thermo-sensibilité de la formulation a permis un relargage sélectif au contact de la peau, tout en assurant une bonne conservation à température ambiante.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract: INTRODUCTION: The treatment of individuals with active tuberculosis (TB) and the identification and treatment of latent tuberculosis infection (LTBI) contacts are the two most important strategies for the control of TB. The objective of this study was compare the performance of tuberculin skin testing (TST) with QuantiFERON-TB Gold In TUBE(r) in the diagnosis of LTBI in contacts of patients with active TB. METHODS: Cross-sectional analytical study with 60 contacts of patients with active pulmonary TB. A blood sample of each contact was taken for interferon-gamma release assay (IGRA) and subsequently performed the TST. A receiver operating characteristic curve was generated to assess the cutoff points and the sensitivity, predictive values, and accuracy were calculated. The agreement between IGRA and TST results was evaluated by Kappa coefficient. RESULTS: Here, 67.9% sensitivity, 84.4% specificity, 79.1% PPV, 75% NPV, and 76.7% accuracy were observed for the 5mm cutoff point. The prevalence of LTBI determined by TST and IGRA was 40% and 46.7%, respectively. CONCLUSIONS: Both QuantiFERON-TB Gold In TUBE(r) and TST showed good performance in LTBI diagnosis. The creation of specific diagnostic methods is necessary for the diagnosis of LTBI with higher sensitivity and specificity, preferably with low cost and not require a return visit for reading because with early treatment of latent forms can prevent active TB.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

It has been reported that patients with progressive tuberculosis (TB) express abundant amounts of the antimicrobial peptides (AMPs) cathelicidin (LL-37) and human neutrophil peptide-1 (HNP-1) in circulating cells, whereas latent TB infected donors showed no differences when compared with purified protein derivative (PPD) and QuantiFERON®-TB Gold (QFT)-healthy individuals. The aim of this study was to determine whether LL-37 and HNP-1 production correlates with higher tuberculin skin test (TST) and QFT values in TB household contacts. Twenty-six TB household contact individuals between 26-58 years old TST and QFT positive with at last two years of latent TB infection were recruited. AMPs production by polymorphonuclear cells was determined by flow cytometry and correlation between TST and QFT values was analysed. Our results showed that there is a positive correlation between levels of HNP-1 and LL-37 production with reactivity to TST and/or QFT levels. This preliminary study suggests the potential use of the expression levels of these peptides as biomarkers for progression in latent infected individuals.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: Reactivation of latent tuberculosis (TB) in inflammatory bowel disease (IBD) patients treated with antitumor necrosis factor-alpha medication is a serious problem. Currently, TB screening includes chest x-rays and a tuberculin skin test (TST). The interferon-gamma release assay (IGRA) QuantiFERON-TB Gold In-Tube (QFT-G-IT) shows better specificity for diagnosing TB than the skin test. This study evaluates the two test methods among IBD patients. METHODS: Both TST and IGRA were performed on 212 subjects (114 Crohn's disease, 44 ulcerative colitis, 10 indeterminate colitis, 44 controls). RESULTS: Eighty-one percent of IBD patients were under immunosuppressive therapy; 71% of all subjects were vaccinated with Bacille Calmette Guérin; 18% of IBD patients and 43% of controls tested positive with the skin test (P < 0.0001). Vaccinated controls tested positive more often with the skin test (52%) than did vaccinated IBD patients (23%) (P = 0.011). Significantly fewer immunosuppressed patients tested positive with the skin test than did patients not receiving therapy (P = 0.007); 8% of patients tested positive with the QFT-G-IT test (14/168) compared to 9% (4/44) of controls. Test agreement was significantly higher in the controls (P = 0.044) compared to the IBD group. CONCLUSIONS: Agreement between the two test methods is poor in IBD patients. In contrast to the QFT-G-IT test, the TST is negatively influenced by immunosuppressive medication and vaccination status, and should thus be replaced by the IGRA for TB screening in immunosuppressed patients having IBD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Antitumour necrosis factor (anti-TNF) treatments may reactivate latent tuberculosis infection (LTBI). For detecting LTBI, the tuberculin skin test (TST) has low sensitivity and specificity. Interferon-gamma release assays (IGRA) have been shown to be more sensitive and specific than TST. OBJECTIVE: To compare the TST and the T-SPOT.TB IGRA for identifying LTBI in patients with psoriasis before anti-TNF treatment. METHODS: A retrospective study was carried out over a 4-year period on patients with psoriasis requiring anti-TNF treatment. All were subjected to the TST, T-SPOT.TB and chest X-ray. Risk factors for LTBI and history of bacillus Calmette-Guérin (BCG) vaccination were recorded. The association of T-SPOT.TB and TST results with risk factors for LTBI was tested through univariate logistic regression models. Agreement between tests was quantified using kappa statistics. Treatment for LTBI was started 1 month before anti-TNF therapy when indicated. RESULTS: Fifty patients were included; 90% had prior BCG vaccination. A positive T-SPOT.TB was strongly associated with a presumptive diagnosis of LTBI (odds ratio 7.43; 95% confidence interval 1.38-39.9), which was not the case for the TST. Agreement between the T-SPOT.TB and TST was poor, kappa = 0.33 (SD 0.13). LTBI was detected and treated in 20% of the patients. In 20% of the cases, LTBI was not retained in spite of a positive TST but a negative T-SPOT.TB. All patients received an anti-TNF agent for a median of 56 weeks (range 20-188); among patients with a positive TST/negative T-SPOT.TB, no tuberculosis was detected with a median follow-up of 64 weeks (44-188). One case of disseminated tuberculosis occurred after 28 weeks of adalimumab treatment in a patient with LTBI in spite of treatment with rifampicin. CONCLUSION: This study is the first to underline the frequency of LTBI in patients with psoriasis (20%), and to support the use of IGRA instead of the TST for its detection. Nevertheless, there is still a risk of tuberculosis under anti-TNF therapy, even if LTBI is correctly diagnosed and treated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)