11 resultados para Reheat


Relevância:

20.00% 20.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new automatic generation controller (AGC) design approach, adopting reinforcement learning (RL) techniques, was recently pro- posed [1]. In this paper we demonstrate the design and performance of controllers based on this RL approach for automatic generation control of systems consisting of units having complex dynamics—the reheat type of thermal units. For such systems, we also assess the capabilities of RL approach in handling realistic system features such as network changes, parameter variations, generation rate constraint (GRC), and governor deadband.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The spallation resistance of an air plasma sprayed (APS) thermal barrier coating (TBC) to cool-down/reheat is evaluated for a pre-existing delamination crack. The delamination emanates from a vertical crack through the coating and resides at the interface between coating and underlying thermally grown oxide layer (TGO). The coating progressively sinters during engine operation, and this leads to a depth-dependent increase in modulus. Following high temperature exposure, the coating is subjected to a cooling/reheating cycle representative of engine shut-down and start-up. The interfacial stress intensity factors are calculated for the delamination crack over this thermal cycle and are compared with the mode-dependent fracture toughness of the interface between sintered APS and TGO. The study reveals the role played by microstructural evolution during sintering in dictating the spallation life of the thermal barrier coating, and also describes a test method for the measurement of delamination toughness of a thin coating. © 2014 Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper firstly expounds that the reheat-regenerative Rankine power cycle is a suitable cycle for the parabolic trough collector, a popular kind of collector in the power industry. In a thermal power cycle, the higher the temperature at which heat is supplied, the higher the efficiency of the cycle. On the other hand, for a given kind of collector at the same exiting temperature, the higher the temperature of the fluid entering the collector, the lower the efficiency of the collector. With the same exiting temperature of the solar field and the same temperature differences at the hottest end of the superheater/reheater and at the pinch points in the heat exchangers (e.g., the boiler) in the cycle, the efficiencies of the system are subject to the temperature of the fluid entering the collector or the saturation temperature at the boiler. This paper also investigates the optimal thermal and exergetic efficiencies for the combined system of the power cycle and collector. To make most advantage of the collector, the exiting fluid is supposed to be at the maximum temperature the collector can harvest. Hence, the thermal and exergetic efficiencies of the system are related to the saturation temperature at the boiler here.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This letter presents a novel approach to the load-frequency control (LFC) of interconnected power systems. Based on functional observers theory, quasi-decentralized functional observers (QDFOs) are designed to implement any given global PI state feedback controller. The designed functional observers are decoupled from each other and also of low-order; thus, they are cost effective and easy to implement. Although the proposed approach is applicable to N- area power systems, an example of a two-area interconnected power system with reheat thermal turbines is considered for simplicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports a new result on the fault detection of dynamical systems by employing only first-order functional observers. Indeed, we show that fault detection can be achieved by utilizing first-order functional observers. The advantages for having such simple structured observers are obvious from the economical and practical points of view as significant cost saving can be achieved. We derive existence conditions and an algorithm for the generation of residual signals to detect faults using firstorder functional observers. Two numerical examples are given to illustrate the proposed fault detection scheme. In one of the examples, a two-area interconnected power system with reheat thermal turbines is considered where only a first-order functional observer is designed to detect faults in the power system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A mathematical model is developed for an irreversible Brayton cycle with regeneration, inter-cooling and reheating. The irreversibility are from the thermal resistance in the heat exchangers, the pressure drops in pipes, the non-isentropic behavior in the adiabatic expansions and compressions and the heat leakage to the cold source. The cycle is optimized by maximizing the ecological function, which is achieved by the search for optimal values for the temperatures of the cycle and for the pressure ratios of the first stage compression and the first stage expansion. The advantages of using the regenerator, intercooler and reheater are presented by comparison with cycles that do not incorporate one or more of these processes. Optimization results are compared with those obtained by maximizing the power output and it is concluded that the point of maximum ecological function has major advantages with respect to the entropy generation rate and the thermal efficiency, at the cost of a small loss in power.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The supercritical Rankine power cycle offers a net improvement in plant efficiency compared with a subcritical Rankine cycle. For fossil power plants the minimum supercritical steam turbine size is about 450MW. A recent study between Sandia National Laboratories and Siemens Energy, Inc., published on March 2013, confirmed the feasibility of adapting the Siemens turbine SST-900 for supercritical steam in concentrated solar power plants, with a live steam conditions 230-260 bar and output range between 140-200 MWe. In this context, this analysis is focused on integrating a line-focus solar field with a supercritical Rankine power cycle. For this purpose two heat transfer fluids were assessed: direct steam generation and molten salt Hitec XL. To isolate solar field from high pressure supercritical water power cycle, an intermediate heat exchanger was installed between linear solar collectors and balance of plant. Due to receiver selective coating temperature limitations, turbine inlet temperature was fixed 550ºC. The design-point conditions were 550ºC and 260 bar at turbine inlet, and 165 MWe Gross power output. Plant performance was assessed at design-point in the supercritical power plant (between 43-45% net plant efficiency depending on balance of plantconfiguration), and in the subcritical plant configuration (~40% net plant efficiency). Regarding the balance of plant configuration, direct reheating was adopted as the optimum solution to avoid any intermediate heat exchanger. One direct reheating stage between high pressure turbine and intermediate pressure turbine is the common practice; however, General Electric ultrasupercritical(350 bar) fossil power plants also considered doubled-reheat applications. In this study were analyzed heat balances with single-reheat, double-reheat and even three reheating stages. In all cases were adopted the proper reheating solar field configurations to limit solar collectors pressure drops. As main conclusion, it was confirmed net plant efficiency improvements in supercritical Rankine line-focus (parabolic or linear Fresnel) solar plant configurations are mainly due to the following two reasons: higher number of feed-water preheaters (up to seven)delivering hotter water at solar field inlet, and two or even three direct reheating stages (550ºC reheating temperature) in high or intermediate pressure turbines. However, the turbine manufacturer should confirm the equipment constrains regarding reheating stages and number of steam extractions to feed-water heaters.