901 resultados para Reembasamento de prótese dentária


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the biosecurity measures adopted in dental prosthesis laboratories of the city of João Pessoa, PB, Brazil with respect to prosthetic works sent by dentists. Method: Twenty-five dental prosthesis technicians (DPT) of the city of João Pessoa, PB, filled out a questionnaire referring to their knowledge of the biosecurity principles, disinfection of impressions and other prosthetic items, and the use of individual protection equipment (IPE). Results: Although 92% of the interviewees believed in the possible occurrence of cross-infection between dental prosthesis laboratories and dental offices, 64% declared that the prosthetic works received in their laboratories do not undergo any disinfection procedure. It was also observed that, for disinfection of impressions and stone casts, the chemical substances are not used as recommended by the manufacturers or are innocuous to microorganisms. Regarding the use of IPE, 60% of the DPT used mask, but only 4% used gowns. With respect to the measures taken regarding the impressions received from dental offices, 56% of the interviewees only wash them in running tap water, and 56% of the stone casts that arrive at the laboratory are not disinfected in any way. Conclusion: There is a need for more motivation and instructions to DPT regarding the prevention of cross-contamination during sending and receiving of prosthetic works between dental prosthesis laboratories and dental offices because the DPT evaluated in this study were found negligent with respect to disinfection procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alveolar bone resorption is continuous throughout the life of edentulous patients, the prosthesis mismatch can generate during speech and chewing. An alternative to this would be to destabilize the denture reline, a maneuver which aims to readjust the denture base to the rim by the addition of a plastic film to the inner surface of the prosthesis material. This procedure may be direct, when performed in the clinic, or indirect when made in prosthetic laboratory. The aim this study is to demonstrate the technical of two reline for denture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effectiveness during a twelve-month period, of resin-modified glass ionomer (Vitremer@) used as fissure sealants compared to supervised teeth brushing in the prevention of oclusal caries in permarient molars of pubIlc school children from 5 to 7 years of age. A total of 91 children participated in the study, being randomly divided up into three groups of investigation: group with sealant (n=31), group of supervised brushing (m=30), and control gorup (n=30). After 12 months, a total of 28.5% of tosses in the sample of 26 children was registered, and although there wasn t a significant diference between these losses and the groups studles (p = 0.6355), there was a considerable reduction in the sample. The results showed that none of the independentIy studied variables (present caries experience, biofilm, bleeding, sealant retention, position of the tooth in the arch, and sex) interfered in the final results, and that there was no significant difference between applying the sealant in question, perfornling supervised dental brushing, or not intervening at alI (p=0.542). These results could have been a consequence of the limitations found alI through the study, especially relating to the losses occurred because of school evasion, transfer, or because of the accident in the Marise Paiva Municipal School, Keeping students away for approximately one semester, so tht a new reseach had to be developed sos as to better clarify the effects among the treatments done there

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The maintenance of masticatory function is especially important for patients who wear complete dentures due to the limitations of this type of prosthesis. Thus, the bilateral balanced occlusion (BBO) is used to achieve, besides other advantages, greater masticatory efficiency. However, analyzing critically the literature, it is observed that there is not enough scientific evidence that support the BBO as the most appropriate occlusal concept in complete dentures. This way, the purpose of the present study was to verify if complete dentures wearers with BBO present better masticatory efficiency and capacity than those with canine guidance (CG). A double-blind controlled crossover clinical trial was conducted. The sample was made of 24 completely edentulous patients. The subjects wore sets of complete dentures with both occlusal concepts for equal periods of 3 months. Objective data were collected through the masticatory efficiency test, performed by the colorimetric method, in which capsules of a synthetic material enclosing fuchsine- containing granules were used. Subjective data were recorded by patient´s ratings of their chewing function, which is the masticatory ability. No significant statistical difference was found for masticatory efficiency (p=0,0952) and masticatory ability (x2=0,5711/ p=0,4498) between the two occlusal concepts studied, as well as there was no correlation between these two variables (p=0,2985). Based on these results, it seems reasonable to use CG for the setup of complete dentures, since it is an easier and quicker technical procedure, until that future researches can come to complement this question

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Even nowadays there is in Brasil a large number of edentulous and a precarious financial condition of most of the population. In addition, World Health Organization aims for oral health, which consists on the maintenance of a natural dentition, functional and aesthetic composed of at least 20 teeth, without need of prosthetic intervention throughout life. From this and considering the lack of researches about the permanence of edentulous spaces in the oral cavity, and also avoiding overtreatment, this research has been proposed. Thus, the aim was to evaluate the effect of different lengths of the shortened lower dental arch in the presence or absence of a removable partial denture (RPD) on masticatory function, quality of life and occurrence of temporomandibular dysfunction. To achieve this goal, we compared the masticatory efficiency (colorimetric test), the oral comfort through the analysis of the impact of oral health in quality of life (OHIP-14), the presence of temporomandibular dysfunction (RDC/TMD) and the general quality of life (WHOQOL) of patients with shortened dental arches (SDA) (n=60), which is an arch with a reduction of teeth starting posteriorly, and patients with complete dental arch (Complete DA) (n = 34). The group of patients whit SDA was divided among PPR wears (PPD + SDA) (n = 17) and non-wears (n = 43). The population of this study consisted on patients who received or looked for treatment at the clinics of the Department of Dentistry of UFRN, from clinical analysis and records. The sample was chosen by convenience. For statistical analysis, it was a database in SPSS 17.0, followed by descriptive analysis with frequencies, absolute values, tests of central tendency and variability. The statistical tests used were chi-squared and analysis of variance as well as Tukey s post test, when applicable, all with a 95% confidence level. The results shown a prevalence of TMD of 47,1% among patients using PRP and 69,8% among those who didn t, but this result wasn t statistically significant. The mean of the results of masticatory efficiency, WHOQOL and OHIP didn t show association to the presence or absence of PPR and to the lower number of occlusal units of the patients (0, 1, 2 or more occlusal). The association only occurred among the different groups of SDA and the patients with complete dental arch. Taking into account the results, it could be observed that studied patients with low posterior support using lower PRP didn t have better masticatory efficiency, general quality of life, less impacts of their oral conditions in quality of life or not even less temporomandibular dysfunction or better masticatory efficiency when compared to those who didn t use the prosthesis

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques