1000 resultados para Receptores x Retinoide


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The human pregnane X receptor (hPXR) is an orphan nuclear receptor that induces transcription of response elements present in steroid-inducible cytochrome P-450 gene promoters. This activation requires the participation of retinoid X receptors (RXRs), needed partners of hPXR to form heterodimers. We have investigated the expression of hPXR and RXRs in normal, premalignant, and malignant breast tissues, in order to determine whether their expression profile in localized infiltrative breast cancer is associated with an increased risk of recurrent disease. METHODS Breast samples from 99 patients including benign breast diseases, in situ and infiltrative carcinomas were processed for immunohistochemistry and Western-blot analysis. RESULTS Cancer cells from patients that developed recurrent disease showed a high cytoplasmic location of both hPXR isoforms. Only the infiltrative carcinomas that relapsed before 48 months showed nuclear location of hPXR isoform 2. This location was associated with the nuclear immunoexpression of RXR-alpha. CONCLUSION Breast cancer cells can express both variants 1 and 2 of hPXR. Infiltrative carcinomas that recurred showed a nuclear location of both hPXR and RXR-alpha; therefore, the overexpression and the subcellular location changes of hPXR could be considered as a potential new prognostic indicator.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several epidemiological studies have related an increase of lipids in the postprandial state to an individual risk for the development of CVD, possibly due to the increased plasma levels of TAG and fatty acids (FA) through enzymes of FA metabolism. The interaction between nutrition and the human genome determines gene expression and metabolic response. The aim of the present study was to evaluate the influence of a fat overload on the gene mRNA levels of lipogenic regulators in peripheral blood mononuclear cells (PBMC) from patients with the metabolic syndrome. The study included twenty-one patients with criteria for the metabolic syndrome who underwent a fat overload. Measurements were made before and after the fat overload of anthropometric and biochemical variables and also the gene mRNA levels of lipogenic factors. The main results were that the fat overload led to an increased mRNA levels of sterol regulatory element binding protein-1 (SREBP1), retinoid X receptor α (RXRα) and liver X receptor α (LXRα) in PBMC, and this increase was associated with the FA synthase (FASN) mRNA levels. We also found that TAG levels correlated with FASN mRNA levels. In addition, there was a positive correlation of SREBP1 with RXRα and of LXRα with the plasma lipoperoxide concentration. The fat overload led to an increase in regulators of lipogenesis in PBMC from patients with the metabolic syndrome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aquest projecte es basa, en el disseny i construcció d’una aplicació directa de l’holografia de microones. Està compost per el disseny d’un sistema el qual és capaç de mesurar la potència que arriba a un sistema d’antenes receptores al travessar un obstacle i posteriorment, mitjançant una sèrie de passos que caracteritzen l’holografia, el que permet és, recuperar una imatge virtual de l’obstacle en qüestió el qual s’ha volgut holografiar. Aquest sistema s’ha elaborat mitjançant un motor rotatori i posteriorment lineal per fer l’escaneig de potència. Primerament el que s’ha dut a terme és una simulació de com el sistema es comportaria en un entorn ideal i posteriorment, s’ha dut a la realitat amb un sistema el qual ens ha permès fer una comparació amb els resultats obtinguts en la simulació. Finalment es mostren els resultats sobre la seva viabilitat.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os receptores de navegação do sistema de posicionamento global (GPS), comumente utilizados pelo setor agrícola, em geral, apresentam precisão posicional < 10,0 m. Em uma amostragem sistemática de solos, as subamostras deverão ser coletadas num raio não superior a 3 m do ponto central georreferenciado. A presente nota técnica visou confrontar a precisão e exatidão desse tipo de equipamento com a necessidade exigida em amostragem sistematizada de solo. Uma área com aproximadamente 17 ha, no campus I da Universidade de Passo Fundo, foi levantada com três receptores GPS de navegação e Estação Total-ET (controle). Pontos centrais de quadrículas de 2 ha, gerados pelo programa Campeiro®, foram locados no campo com os mesmos equipamentos. Sobre esses pontos, materializados no campo, foram novamente tomadas as suas coordenadas, com auxílio da estação total. Assim, as coordenadas X e Y foram submetidas à ANOVA, confrontando-se as médias obtidas pela ET com as dos receptores de GPS pela diferença honesta significativa do teste de Tukey (p < 0,01). Quanto à exatidão, calcularam-se, por Pitágoras, as distâncias lineares entre os pontos gerados pelos GPS e pela ET, assumindo-se não exatas quando ultrapassaram os 3 m de raio preconizado pelo Manual de Adubação e Calagem do Rio Grande do Sul e de Santa Catariana para coleta de solo. A exatidão das coordenadas dos receptores GPS variou de -10 m a +3 m para X e de -4 m a +7 m para Y. Apenas um ponto central dos oito locados com os receptores de GPS de navegação no centro das quadrículas apresentou exatidão compatível com a exigida pela prática. Isso indica que esse tipo de equipamento, com baixa precisão e exatidão, não deve ser utilizado para amostragem sistematizada de solos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar cotas de vértices de uma poligonal, considerando dados coletados por três diferentes receptores GPS, usando como testemunha uma estação total. Os dados foram obtidos em uma poligonal fechada, sendo posteriormente tratados pelo software Topograph. As cotas obtidas pelos três receptores foram confrontadas com aquelas calculadas a partir do levantamento com a estação total, mediante a aplicação do teste "t", constatando-se que as mesmas foram satisfatórias para o equipamento GPS Trimble® 4600 LS. Para o equipamento GPS Trimble® modelo PRO XR, as cotas não foram totalmente satisfatórias, mas possíveis de serem consideradas em anteprojetos. Para o equipamento GPS Garmin® de navegação 12 XS, as cotas mostraram-se inaceitáveis para a finalidade estudada.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El trasplante de órganos y/o tejidos es considerado como una opción terapéutica viable para el tratamiento tanto de enfermedades crónicas o en estadios terminales, como de afectaciones no vitales, pero que generen una disminución en la calidad de vida percibida por el paciente. Este procedimiento, de carácter multidimensional, está compuesto por 3 actores principales: el donante, el órgano/tejido, y el receptor. Si bien un porcentaje significativo de investigaciones y planes de intervención han girado en torno a la dimensión biológica del trasplante, y a la promoción de la donación; el interés por la experiencia psicosocial y la calidad de vida de los receptores en este proceso ha aumentado durante la última década. En relación con esto, la presente monografía se plantea como objetivo general la exploración de la experiencia y los significados construidos por los pacientes trasplantados, a través de una revisión sistemática de la literatura sobre esta temática. Para ello, se plantearon unos objetivos específicos derivados del general, se seleccionaron términos o palabras claves por cada uno de estos, y se realizó una búsqueda en 5 bases de datos para revistas indexadas: Ebsco Host (Academic Search; y Psychology and Behavioral Sciences Collection); Proquest; Pubmed; y Science Direct. A partir de los resultados, se establece que si bien la vivencia de los receptores ha comenzado a ser investigada, aún es necesaria una mayor exploración sobre la experiencia de estos pacientes; exploración que carecería de objetivo si no se hiciera a través de las narrativas o testimonios de los mismos receptores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Metabolic syndrome (MS) is defined as a set of cardiovascular risk factors including obesity, systemic high blood pressure (SHBP), changes in glucose metabolism and dyslipidemia. The prevalence of MS in renal transplant recipients (RTR) ranges from 15% to 65%, increasing the risk of cardiovascular disease (CVD) and reducing renal allograft survival in the long term. The objectives of this study were to determine the prevalence and frequency of MS in renal transplant patients according to gender and time of transplantation and to evaluate renal function in patients with and without MS. Patients and Methods: Crosssectional study conducted from August 2012 to September 2013 involving 153 renal transplant recipients. MS was defined according to the National Cholesterol Education Program (NCEP) Adult Treatment Panel III (ATP III). The sample was divided into two groups: patients with metabolic syndrome (WMS patients) and patients without metabolic syndrome (WoMS patients) and according to gender. The WMS patients were stratified into quartiles according to the renal transplantation period (RTP), and variables related to MS were analyzed for both sexes. Results: MS was diagnosed in 58.1% of the studied population, specifically in MS was found 58.4% of men and 41.6% of women (P ˂ 0.05). The male and female with MS were 48.8 ± 11.6 years old vs. 47.1 ± 12.7 years old and the time of post transplantation was 76.1 ± 76.5 months vs. 84.7 ± 65.4 months, respectively (P >0,05). When we compared the sexes in the WMS group, systolic blood pressure (SBP) was higher in men (137.0 ± 18.1 vs. 128.9 ± 13.6 mmHg, P= 0.029), while the other components of MS did not exhibit significant differences. With respect to renal function, when we compared the sexes in the WMS group, the serum creatinine (sCr) was higher in men (1.73 ± 0.69 vs. 1.31 ± 0.47 mg/dL, P= 0.0012), while the urinary protein/creatinine ratio was higher in women (0.48 ± 0.69 vs. 0.37 ± 0.48 mg/dL, P=0.0150). We found no significant difference in the estimated glomerular filtration rate (eGFR) between WMS and WoMS patients for women and men (50.6 ± 19.1 vs. 50.1 ± 18.3 mL/min/1.73 m², P=0.909). We found a significant positive association between eGFR and HDL-c levels (r=0.3371; P=0.0145) for WMS men. The MS components showed no significant differences in RTP for different interquartile ranges, except for diastolic blood pressure (DBP) in women, where there was a significant variation among the quartiles evaluated (P=0.0009). Conclusion: the prevalence of MS was similar in the different quartiles in both sexes, in relation to time post TX. There was no significant difference in eGFR in patients WMS and WoMS, in both sexes. Concluding that the MS did not vary in relation to time post transplant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The raft hypothesis proposes that microdomains enriched in sphingolipids, cholesterol, and specific proteins are transiently formed to accomplish important cellular tasks. Equivocally, detergent-resistant membranes were initially assumed to be identical to membrane rafts, because of similarities between their compositions. In fact, the impact of detergents in membrane organization is still controversial. Here, we use phase contrast and fluorescence microscopy to observe giant unilamellar vesicles (GUVs) made of erythrocyte membrane lipids (erythro-GUVs) when exposed to the detergent Triton X-100 (TX-100). We clearly show that TX-100 has a restructuring action on biomembranes. Contact with TX-100 readily induces domain formation on the previously homogeneous membrane of erythro-GUVs at physiological and room temperatures. The shape and dynamics of the formed domains point to liquid-ordered/liquid-disordered (Lo/Ld) phase separation, typically found in raft-like ternary lipid mixtures. The Ld domains are then separated from the original vesicle and completely solubilized by TX-100. The insoluble vesicle left, in the Lo phase, represents around 2/3 of the original vesicle surface at room temperature and decreases to almost 1/2 at physiological temperature. This chain of events could be entirely reproduced with biomimetic GUVs of a simple ternary lipid mixture, 2:1:2 POPC/SM/chol (phosphatidylcholine/sphyngomyelin/cholesterol), showing that this behavior will arise because of fundamental physicochemical properties of simple lipid mixtures. This work provides direct visualization of TX-100-induced domain formation followed by selective (Ld phase) solubilization in a model system with a complex biological lipid composition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To verify whether fluorescence in situ hybridization (FISH) of cells from the buccal epithelium could be employed to detect cryptomosaicism with a 45,X lineage in 46,XY patients. Samples of nineteen 46,XY healthy young men and five patients with disorders of sex development (DSD), four 45,X/46,XY and one 46,XY were used. FISH analysis with X and Y specific probes on interphase nuclei from blood lymphocytes and buccal epithelium were analyzed to investigate the proportion of nuclei containing only the signal of the X chromosome. The frequency of nuclei containing only the X signal in the two tissues of healthy men did not differ (p = 0.69). In all patients with DSD this frequency was significantly higher, and there was no difference between the two tissues (p = 0.38), either. Investigation of mosaicism with a 45,X cell line in patients with 46,XY DSD or sterility can be done by FISH directly using cells from the buccal epithelium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the energy response functions of a CdTe detector were obtained by Monte Carlo (MC) simulation in the energy range from 5 to 160keV, using the PENELOPE code. In the response calculations the carrier transport features and the detector resolution were included. The computed energy response function was validated through comparison with experimental results obtained with (241)Am and (152)Eu sources. In order to investigate the influence of the correction by the detector response at diagnostic energy range, x-ray spectra were measured using a CdTe detector (model XR-100T, Amptek), and then corrected by the energy response of the detector using the stripping procedure. Results showed that the CdTe exhibits good energy response at low energies (below 40keV), showing only small distortions on the measured spectra. For energies below about 80keV, the contribution of the escape of Cd- and Te-K x-rays produce significant distortions on the measured x-ray spectra. For higher energies, the most important correction is the detector efficiency and the carrier trapping effects. The results showed that, after correction by the energy response, the measured spectra are in good agreement with those provided by a theoretical model of the literature. Finally, our results showed that the detailed knowledge of the response function and a proper correction procedure are fundamental for achieving more accurate spectra from which quality parameters (i.e., half-value layer and homogeneity coefficient) can be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray fluorescence (XRF) is a fast, low-cost, nondestructive, and truly multielement analytical technique. The objectives of this study are to quantify the amount of Na(+) and K(+) in samples of table salt (refined, marine, and light) and to compare three different methodologies of quantification using XRF. A fundamental parameter method revealed difficulties in quantifying accurately lighter elements (Z < 22). A univariate methodology based on peak area calibration is an attractive alternative, even though additional steps of data manipulation might consume some time. Quantifications were performed with good correlations for both Na (r = 0.974) and K (r = 0.992). A partial least-squares (PLS) regression method with five latent variables was very fast. Na(+) quantifications provided calibration errors lower than 16% and a correlation of 0.995. Of great concern was the observation of high Na(+) levels in low-sodium salts. The presented application may be performed in a fast and multielement fashion, in accordance with Green Chemistry specifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic imaging techniques play an important role in assessing the exact location, cause, and extent of a nerve lesion, thus allowing clinicians to diagnose and manage more effectively a variety of pathological conditions, such as entrapment syndromes, traumatic injuries, and space-occupying lesions. Ultrasound and nuclear magnetic resonance imaging are becoming useful methods for this purpose, but they still lack spatial resolution. In this regard, recent phase contrast x-ray imaging experiments of peripheral nerve allowed the visualization of each nerve fiber surrounded by its myelin sheath as clearly as optical microscopy. In the present study, we attempted to produce high-resolution x-ray phase contrast images of a human sciatic nerve by using synchrotron radiation propagation-based imaging. The images showed high contrast and high spatial resolution, allowing clear identification of each fascicle structure and surrounding connective tissue. The outstanding result is the detection of such structures by phase contrast x-ray tomography of a thick human sciatic nerve section. This may further enable the identification of diverse pathological patterns, such as Wallerian degeneration, hypertrophic neuropathy, inflammatory infiltration, leprosy neuropathy and amyloid deposits. To the best of our knowledge, this is the first successful phase contrast x-ray imaging experiment of a human peripheral nerve sample. Our long-term goal is to develop peripheral nerve imaging methods that could supersede biopsy procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dendrochemistry is based on the determination of elements retained in tree rings, which can be useful to characterize environmental occurrences. This work shows elemental mappings obtained by EDXRF of the cross section of a tree stem. The tree is originated from a polluted area in Campinas, São Paulo. Some profiles, as the sulfur one, show variations that can be attributed to external contributions, whereas the silicon one can be inferred to a protection defense natural mechanism. Besides being simultaneous and multielementar, the main advantages here are its performance through a non-destructive sample treatment and the ease of operation of XRF equipments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antimony is a common catalyst in the synthesis of polyethylene terephthalate used for food-grade bottles manufacturing. However, antimony residues in final products are transferred to juices, soft drinks or water. The literature reports mentions of toxicity associated to antimony. In this work, a green, fast and direct method to quantify antimony, sulfur, iron and copper, in PET bottles by X-ray fluorescence spectrometry is presented. 2.4 to 11 mg Sb kg-1 were found in 20 samples analyzed. The coupling of the multielemental technique to chemometric treatment provided also the possibility to classify PET samples between bottle-grade PET/recycled PET blends by Fe content.