811 resultados para Recall interval
Resumo:
PURPOSE: To determine whether the treatment of dental caries with ozone was possible in apprehensive children and to ascertain whether ozone reverses caries in open single-surface lesions. Further, the influence of ozone on laser fluorescence was investigated. METHODS: 82 lesions in 28 children with at least two open single-surface lesions were assessed. The children were anxious and were judged by the referring dentist as non-treatable. For each test lesion, which was treated with ozone, a control lesion was left without ozone treatment. Hardness and laser fluorescence values were assessed and the changes for hardness and laser fluorescence values in the test lesion were compared with the values in the control lesion after 2, 4, 6, and 8 months. RESULTS: 94 percent of the children were treatable and 93% lost their dental anxiety. The hardness values improved significantly in the ozone-treated test lesions after 4, 6, and 8 months (P< 0.05) compared with baseline while the control lesions had no significant change in hardness at any recall interval. Comparing the differences between test and control teeth over time, the laser fluorescence values improved, however the improvement was not statistically significant (P> 0.05). The use of ozone resulted in an average reduction of 13% of the laser fluorescence values immediately after the ozone treatment.
Resumo:
BACKGROUND Sedentary behavior is continuing to emerge as an important target for health promotion. The purpose of this study was to determine the validity of a self-report use of time recall tool, the Multimedia Activity Recall for Children and Adults (MARCA) in estimating time spent sitting/lying, compared with a device-based measure. METHODS Fifty-eight participants (48% female, [mean±standard deviation] 28±7.4 years of age, 23.9±3.05 kg/m2) wore an activPAL device for 24-h and the following day completed the MARCA. Pearson correlation coefficients (r) were used to analyse convergent validity of the adult MARCA compared with activPAL estimates of total sitting/lying time. Agreement was examined using Bland-Altman plots. RESULTS According to activPAL estimates, participants spent 10.4 hr/day [standard deviation (SD)=2.06] sitting or lying down while awake. The correlation between MARCA and activPAL estimates of total sit/lie time was r=0.77 (95% confidence interval = 0.64-0.86; p<0.001). Bland-Altman analyses revealed a mean bias of +0.59 hr/day with moderately wide limits of agreement (-2.35 hours to +3.53 hr/day). CONCLUSIONS This study found a moderate to strong agreement between the adult MARCA and the activPAL, suggesting that the MARCA is an appropriate tool for the measurement of time spent sitting or lying down in an adult population.
Resumo:
Background Sedentary behaviour is associated with several deleterious health consequences. Although device-based measures of sedentary time are available, they are costly and do not provide a measure of domain specific sedentary time. High quality self-report measures are necessary to accurately capture domain specific sedentary time, and to provide an alternative to devices when cost is an issue. In this study, the Past-day Adults’ Sedentary Time (PAST) questionnaire, previously shown to have acceptable validity and reliability in a sample of breast cancer survivors, was modified for a university sample and validity of the modified questionnaire was examined compared with activPAL. Methods Participants (n = 58, age = 18–55 years, 48% female, 66% students) were recruited from the University of Queensland (students and staff). They answered the PAST questionnaire, which asked about time spent sitting or lying down for work, study, travel, television viewing, leisure-time computer use, reading, eating, socialising and other purposes, during the previous day. Time reported for these questions was summed to provide a measure of total sedentary time. Participants also wore an activPAL device for the full day prior to completing the questionnaire and recorded their wake and sleep times in an activity log. Total waking sedentary time derived from the activPAL was used as the criterion measure. Correlation (Pearson's r) and agreement (Bland–Altman plots) between PAST and activPAL sedentary time were examined. Results Participants were sedentary (activPAL-determined) for approximately 66% of waking hours. The correlation between PAST and activPAL sedentary time for the whole sample was r = 0.50 [95% confidence interval (CI) = 0.28–0.67]; and higher for non-students (r = 0.63, 95% CI = 0.26–0.84) than students (r = 0.46, 95% CI = 0.16–0.68). Bland–Altman plots revealed that the mean difference between the two measures was 19 min although limits of agreement were wide (95% limits of agreement −4.1 to 4.7 h). Discussion The PAST questionnaire provides an acceptable measure of sedentary time in this population, which included students and adults with high workplace sitting. These findings support earlier research that questionnaires employing past-day recall of sedentary time provide a viable alternative to existing sedentary behaviour questionnaires.
Resumo:
This study examined the effect of schemas on consistency and accuracy of memory across interviews, providing theoretical hypotheses explaining why inconsistencies may occur. The design manipulated schema-typicality of items (schema-typical and atypical), question format (free-recall, cued-recall and recognition) and retention interval (immediate/2 week and 2 week/4 week). Consistency, accuracy and experiential quality of memory were measured. ^ All independent variables affected accuracy and experiential quality of memory while question format was the only variable affecting consistency. These results challenge the commonly held notion in the legal arena that consistency is a proxy for accuracy. The study also demonstrates that other variables, such as item-typicality and retention interval have different effects on consistency and accuracy in memory. ^
Resumo:
This paper investigates the effectiveness of virtual product placement as a marketing tool by examining the relationship between brand recall and recognition and virtual product placement. It also aims to address a gap in the existing academic literature by focusing on the impact of product placement on recall and recognition of new brands. The growing importance of product placement is discussed and a review of previous research on product placement and virtual product placement is provided. The research methodology used to study the recall and recognition effects of virtual product placement are described and key findings presented. Finally, implications are discussed and recommendations for future research provided.
Resumo:
Despite its growth and prominence, product placement is generally under-researched and this is even more apparent in the area of placement in video gaming. This paper presents exploratory focus group research into this practice. Findings indicate that the introductory footage to a game provides placement opportunities with the highest level of recall, while peripheral non-action is the worst. Interestingly, recall also appears to be higher for individual brands as opposed to manufacturer brands.
Resumo:
One of the key issues in today’s competitive business environment advertising effectiveness. An important component to any advertising campaign or commercial is, whether or not it will be remembered. If a consumer cannot remember one’s brand name, how can one persuade them to buy it? Over the years, various techniques have been designed to measure the impact and effectiveness of advertisements, as well as how well they are remembered.
Resumo:
This paper investigates the robust H∞ control for Takagi-Sugeno (T-S) fuzzy systems with interval time-varying delay. By employing a new and tighter integral inequality and constructing an appropriate type of Lyapunov functional, delay-dependent stability criteria are derived for the control problem. Because neither any model transformation nor free weighting matrices are employed in our theoretical derivation, the developed stability criteria significantly improve and simplify the existing stability conditions. Also, the maximum allowable upper delay bound and controller feedback gains can be obtained simultaneously from the developed approach by solving a constrained convex optimization problem. Numerical examples are given to demonstrate the effectiveness of the proposed methods.
Resumo:
Background: Assessments of change in subjective patient reported outcomes such as health-related quality of life (HRQoL) are a key component of many clinical and research evaluations. However, conventional longitudinal evaluation of change may not agree with patient perceived change if patients' understanding of the subjective construct under evaluation changes over time (response shift) or if patients' have inaccurate recollection (recall bias). This study examined whether older adults' perception of change is in agreement with conventional longitudinal evaluation of change in their HRQoL over the duration of their hospital stay. It also investigated this level of agreement after adjusting patient perceived change for recall bias that patients may have experienced. Methods: A prospective longitudinal cohort design nested within a larger randomised controlled trial was implemented. 103 hospitalised older adults participated in this investigation at a tertiary hospital facility. The EQ-5D utility and Visual Analogue Scale (VAS) scores were used to evaluate HRQoL. Participants completed EQ-5D reports as soon as they were medically stable (within three days of admission) then again immediately prior to discharge. Three methods of change score calculation were used (conventional change, patient perceived change and patient perceived change adjusted for recall bias). Agreement was primarily investigated using intraclass correlation coefficients (ICC) and limits of agreement. Results: Overall 101 (98%) participants completed both admission and discharge assessments. The mean (SD) age was 73.3 (11.2). The median (IQR) length of stay was 38 (20-60) days. For agreement between conventional longitudinal change and patient perceived change: ICCs were 0.34 and 0.40 for EQ-5D utility and VAS respectively. For agreement between conventional longitudinal change and patient perceived change adjusted for recall bias: ICCs were 0.98 and 0.90 respectively. Discrepancy between conventional longitudinal change and patient perceived change was considered clinically meaningful for 84 (83.2%) of participants, after adjusting for recall bias this reduced to 8 (7.9%). Conclusions: Agreement between conventional change and patient perceived change was not strong. A large proportion of this disagreement could be attributed to recall bias. To overcome the invalidating effect of response shift (on conventional change) and recall bias (on patient perceived change) a method of adjusting patient perceived change for recall bias has been described.
Resumo:
When an organisation becomes aware that one of its products may pose a safety risk to customers, it must take appropriate action as soon as possible or it can be held liable. The ability to automatically trace potentially dangerous goods through the supply chain would thus help organisations fulfill their legal obligations in a timely and effective manner. Furthermore, product recall legislation requires manufacturers to separately notify various government agencies, the health department and the public about recall incidents. This duplication of effort and paperwork can introduce errors and data inconsistencies. In this paper, we examine traceability and notification requirements in the product recall domain from two perspectives: the activities carried out during the manufacturing and recall processes and the data collected during the enactment of these processes. We then propose a workflow-based coordination framework to support these data and process requirements.