995 resultados para Reactive sources


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper studies the feasibility of utilizing the reactive power of grid-connected variable-speed wind generators to enhance the steady-state voltage stability margin of the system. Allowing wind generators to work at maximum reactive power limit may cause the system to operate near the steady-state stability limit, which is undesirable. This necessitates proper coordination of reactive power output of wind generators with other reactive power controllers in the grid. This paper presents a trust region framework for coordinating reactive output of wind generators-with other reactive sources for voltage stability enhancement. Case studies on 418-bus equivalent system of Indian southern grid indicates the effectiveness of proposed methodology in enhancing the steady-state voltage stability margin.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An approach for solving reactive power planning problems is presented, which is based on binary search techniques and the use of a special heuristic to obtain a discrete solution. Two versions were developed, one to run on conventional (sequential) computers and the other to run on a distributed memory (hypercube) machine. This latter parallel processing version employs an asynchronous programming model. Once the set of candidate buses has been defined, the program gives the location and size of the reactive sources needed(if any) in keeping with operating and security constraints.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A metaheuristic technique for solving the short-term transmission network expansion and reactive power planning problems, at the same time, in regulated power systems using the AC model is presented. The problem is solved using a real genetic algorithm (RGA). For each topology proposed by RGA an indicator is employed to identify the weak buses for new reactive power sources allocation. The fitness function is calculated using the cost of each configuration as well as constraints deviation of an AC optimal power flow (OPF) in which the minimum reactive generation of new reactive sources and the active power losses are objectives. With allocation of reactive power sources at load buses, the circuit capacity increases and the cost of installation could be decreased. The method is tested in a well known test system, presenting good results when compared with other approaches. © 2011 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Deterministic Optimal Reactive Power Dispatch problem has been extensively studied, such that the demand power and the availability of shunt reactive power compensators are known and fixed. Give this background, a two-stage stochastic optimization model is first formulated under the presumption that the load demand can be modeled as specified random parameters. A second stochastic chance-constrained model is presented considering uncertainty on the demand and the equivalent availability of shunt reactive power compensators. Simulations on six-bus and 30-bus test systems are used to illustrate the validity and essential features of the proposed models. This simulations shows that the proposed models can prevent to the power system operator about of the deficit of reactive power in the power system and suggest that shunt reactive sourses must be dispatched against the unavailability of any reactive source. © 2012 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A combinatorial mathematical model in tandem with a metaheuristic technique for solving transmission network expansion planning (TNEP) using an AC model associated with reactive power planning (RPP) is presented in this paper. AC-TNEP is handled through a prior DC model while additional lines as well as VAr-plants are used as reinforcements to cope with real network requirements. The solution of the reinforcement stage can be obtained by assuming all reactive demands are supplied locally to achieve a solution for AC-TNEP and by neglecting the local reactive sources, a reactive power planning (RPP) will be managed to find the minimum required reactive power sources. Binary GA as well as a real genetic algorithm (RCA) are employed as metaheuristic optimization techniques for solving this combinatorial TNEP as well as the RPP problem. High quality results related with lower investment costs through case studies on test systems show the usefulness of the proposal when working directly with the AC model in transmission network expansion planning, instead of relaxed models. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A combined methodology consisting of successive linear programming (SLP) and a simple genetic algorithm (SGA) solves the reactive planning problem. The problem is divided into operating and planning subproblems; the operating subproblem, which is a nonlinear, ill-conditioned and nonconvex problem, consists of determining the voltage control and the adjustment of reactive sources. The planning subproblem consists of obtaining the optimal reactive source expansion considering operational, economical and physical characteristics of the system. SLP solves the optimal reactive dispatch problem related to real variables, while SGA is used to determine the necessary adjustments of both the binary and discrete variables existing in the modelling problem. Once the set of candidate busbars has been defined, the program implemented gives the location and size of the reactive sources needed, if any, to maintain the operating and security constraints.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The control paradigms of the distributed generation (DG) sources in the smart grid are realised by either utilising virtual power plant (VPP) or by employing MicroGrid structures. Both VPP and MicroGrid are presented with the problem of control of power flow between their comprising DG sources. This study depicts this issue for VPP and proposes a novel and improved universal active and reactive power flow controllers for three-phase pulse width modulated voltage source inverters (PWM-VSI) operating in the VPP environment. The proposed controller takes into account all cases of R-X relationship, thus allowing it to function in systems operating at high, medium (MV) and low-voltage (LV) levels. Also proposed control scheme for the first time in an inverter control takes into account the capacitance of the transmission line which is an important factor to accurately represent medium length transmission lines. This allows the proposed control scheme to be applied in VPP structures, where DG sources can operate at MV LV levels over a short/medium length transmission line. The authors also conducted small signal stability analysis of the proposed controller and compared it against the small signal study of the existing controllers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

High fat diets and accompanying hepatic steatosis are highly prevalent conditions. Previous work has shown that steatosis is accompanied by enhanced generation of reactive oxygen species (ROS), which may mediate further liver damage. Here we investigated mechanisms leading to enhanced ROS generation following high fat diets (HFD). We found that mitochondria from HFD livers present no differences in maximal respiratory rates and coupling, but generate more ROS specifically when fatty acids are used as substrates. Indeed, many acyl-CoA dehydrogenase isoforms were found to be more highly expressed in HFD livers, although only the very long chain acyl-CoA dehydrogenase (VLCAD) was more functionally active. Studies conducted with permeabilized mitochondria and different chain length acyl-CoA derivatives suggest that VLCAD is also a source of ROS production in mitochondria of HFD animals. This production is stimulated by the lack of NAD+. Overall, our studies uncover VLCAD as a novel, diet-sensitive, source of mitochondrial ROS.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Approximately 25% of acute myeloid leukemias (AMLs) carry internal tandem duplications (ITD) of various lengths within the gene encoding the FMS-like tyrosine kinase receptor 3 (FLT3). Although varying duplication sites exist, most of these length mutations affect the protein´s juxtamembrane domain. FLT3-ITDs support leukemic transformation by constitutive phosphorylation resulting in uncontrolled activation, and their presence is associated with worse prognosis. As known form previous work, they represent leukemia- and patient-specific neoantigens that can be recognized by autologous AML-reactive CD8+ T cells (Graf et al., 2007; Graf et al., unpublished). Herein, in patient FL, diagnosed with FLT3-ITD+ AML and in first complete remission after induction chemotherapy, T cells against her leukemia´s individual FLT3-ITD were detected at a frequency up to 1.7x10-3 among peripheral blood CD8+ T lymphocytes. This rather high frequency suggested, that FLT3-ITD-reactive T cells had been expanded in vivo due to the induction of an anti-leukemia response.rnrnCell material from AML patients is limited, and the patients´ anti-leukemia T-cell repertoire might be skewed, e.g. due to complex previous leukemia-host interactions and chemotherapy. Therefore, allogeneic sources, i.e. buffy coats (BCs) from health donors and umbilical cord blood (UCB) donations, were exploited for the presence and the expansion of FLT3-ITD-reactive T-cell populations. BC- and UCB-derived CD8+ T cells, were distributed at 105 cells per well on microtiter plates and, were stimulated with antigen-presenting cells (APCs) transfected with in vitro-transcribed mRNA (IVT-mRNA) encoding selected FTL3-ITDs. APCs were autologous CD8- blood mononuclear cells, monocytes or FastDCs.rnrnBuffy coat lymphocytes from 19 healthy individuals were analyzed for CD8+ T-cell reactivity against three immunogenic FLT3-ITDs previously identified in patients VE, IN and QQ and designated as VE_, IN_ and QQ_FLT3-ITD, respectively. These healthy donors carried at least one of the HLA I alleles known to present an ITD-derived peptide from one of these FLT3-ITDs. Reactivities against single ITDs were observed in 8/19 donors. In 4 donors the frequencies of ITD-reactive T cells were determined and were estimated to be in the range of 1.25x10-6 to 2.83x10-7 CD8+ T cells. These frequencies were 1,000- to 10,000-fold lower than the frequency of autologous FLT3-ITD-reactive T cells observed in patient FL. Restricting HLA I molecules were identified in two donors. In one of them, the recognition of VE_FLT3-ITD was found to be restricted by HLA-C*07:02, which is different from the HLA allele restricting the anti-ITD T cells of patient VE. In another donor, the recognition of IN_FLT3-ITD was restricted by HLA-B*35:01, which also had been observed in patient IN (Graf et al., unpublished). By gradual 3´-fragmentation of the IN_FLT3-ITD cDNA, the 10-mer peptide CPSDNEYFYV was identified as the target of allogeneic T cells against IN_FLT3-ITD. rnLymphocytes in umbilical cord blood predominantly exhibit a naïve phenotype. Seven UCB donations were analyzed for T-cell responses against the FLT3-ITDs of patients VE, IN, QQ, JC and FL irrespective of their HLA phenotype. ITD-reactive responses against all stimulatory FLT3-ITDs were observed in 5/7 UCB donations. The frequencies of T cells against single FLT3-ITDs in CD8+ lymphocytes were estimated to be in the range of 1.8x10-5 to 3.6x10-6, which is nearly 15-fold higher than the frequencies observed in BCs. Restricting HLA I molecules were identified in 4 of these 5 positive UCB donations. They were mostly different from those observed in the respective patients. But in one UCB donation T cells against the JC_FLT3-ITD had exactly the same peptide specificity and HLA restriction as seen before in patient JC (Graf et al., 2007). Analyses of UCB responder lymphocytes led to the identification of the 10-mer peptide YESDNEYFYV, encoded by FL_FLT3-ITD, that was recognized in association with the frequent allele HLA-A*02:01. This peptide was able to stimulate and enrich ITD-reactive T cells from UCB lymphocytes in vitro. Peptide responders not only recognized the peptide, but also COS-7 cells co-transfected with FL_FLT3-ITD and HLA-A*02:01.rnrnIn conclusion, T cells against AML- and individual-specific FLT3-ITDs were successfully generated not only from patient-derived blood, but also from allogeneic sources. Thereby, ITD-reactive T cells were detected more readily and at higher frequencies in umbilical cord blood than in buffy coat lymphocytes. It occurred that peptide specificity and HLA restriction of allogeneic, ITD-reactive T cells were identical to autologous patient-derived T cells. As shown herein, allogeneic, FLT3-ITD-reactive T cells can be used for the identification of FLT3-ITD-encoded peptides, e.g. for future therapeutic vaccination studies. In addition, these T cells or their receptors can be applied to adoptive transfer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Wind energy installations are increasing in power systems worldwide and wind generation capacity tends to be located some distance from load centers. A conflict may arise at times of high wind generation when it becomes necessary to curtail wind energy in order to maintain conventional generators on-line for the provision of voltage control support at load centers. Using the island of Ireland as a case study and presenting commercially available reactive power support devices as possible solutions to the voltage control problems in urban areas, this paper explores the reduction in total generation costs resulting from the relaxation of the operational constraints requiring conventional generators to be kept on-line near load centers for reactive power support. The paper shows that by 2020 there will be possible savings of 87€m per annum and a reduction in wind curtailment of more than a percentage point if measures are taken to relax these constraints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a new power sharing control method for a microgrid with several distributed generation units is proposed. The presence of both inertial and noninertial sources with different power ratings, maximum power point tracking, and various types of loads pose a great challenge for the power sharing and system stability. The conventional droop control method is modified to achieve the desired power sharing ensuring system stability in a highly resistive network. A transformation matrix is formed to derive equivalent real and reactive power output of the converter and equivalent feedback gain matrix for the modified droop equation. The proposed control strategy, aimed for the prototype microgrid planned at Queensland University of Technology, is validated through extensive simulation results using PSCAD/EMTDC software.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes protection and control of a microgrid with converter interfaced micro sources. The proposed protection and control scheme consider both grid connected and autonomous operation of the microgrid. A protection scheme, capable of detecting faults effectively in both grid connected and islanded operations is proposed. The main challenge of the protection, due to current limiting state of the converters is overcome by using admittance relays. The relays operate according to the inverse time characteristic based on measured admittance of the line. The proposed scheme isolates the fault from both sides, while downstream side of the microgrid operates in islanding condition. Moreover faults can be detected in autonomous operation. In grid connected mode distributed generators (DG) supply the rated power while in absence of the grid, DGs share the entire power requirement proportional to rating based on output voltage angle droop control. The protection scheme ensures minimum load shedding with isolating the faulted network and DG control provides a smooth islanding and resynchronization operation. The efficacy of coordinated control and protection scheme has been validated through simulation for various operating conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes new droop control methods for load sharing in a rural area with distributed generation. Highly resistive lines, typical of rural low voltage networks, always create a big challenge for conventional droop control. To overcome the conflict between higher feedback gain for better power sharing and system stability in angle droop, two control methods have been proposed. The first method considers no communication among the distributed generators (DGs) and regulates the converter output voltage and angle ensuring proper sharing of load in a system having strong coupling between real and reactive power due to high line resistance. The second method, based on a smattering of communication, modifies the reference output volt-age angle of the DGs depending on the active and reactive power flow in the lines connected to point of common coupling (PCC). It is shown that with the second proposed control method, an economical and minimum communication system can achieve significant improvement in load sharing. The difference in error margin between proposed control schemes and a more costly high bandwidth communication system is small and the later may not be justified considering the increase in cost. The proposed control shows stable operation of the system for a range of operating conditions while ensuring satisfactory load sharing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reactive oxygen species (ROS) and related free radicals are considered to be key factors underpinning the various adverse health effects associated with exposure to ambient particulate matter. Therefore, measurement of ROS is a crucial factor for assessing the potential toxicity of particles. In this work, a novel profluorescent nitroxide, BPEAnit, was investigated as a probe for detecting particle-derived ROS. BPEAnit has a very low fluorescence emission due to inherent quenching by the nitroxide group, but upon radical trapping or redox activity, a strong fluorescence is observed. BPEAnit was tested for detection of ROS present in mainstream and sidestream cigarette smoke. In the case of mainstream cigarette smoke, there was a linear increase in fluorescence intensity with an increasing number of cigarette puffs, equivalent to an average of 101 nmol ROS per cigarette based on the number of moles of the probe reacted. Sidestream cigarette smoke sampled from an environmental chamber exposed BPEAnit to much lower concentrations of particles, but still resulted in a clearly detectible increase in fluorescence intensity with sampling time. It was calculated that the amount of ROS was equivalent to 50 ± 2 nmol per mg of particulate matter; however, this value decreased with ageing of the particles in the chamber. Overall, BPEAnit was shown to provide a sensitive response related to the oxidative capacity of the particulate matter. These findings present a good basis for employing the new BPEAnit probe for the investigation of particle-related ROS generated from cigarette smoke as well as from other combustion sources.