921 resultados para Randomized controlled clinical trial


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to compare twice daily tooth-brushing using 0.304 percent fluoride toothpaste alone with: (1) twice daily tooth-brushing plus once daily 10% casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) paste; and (2) twice daily tooth-brushing plus once daily 0.12% chlorhexidine gel (CHX) for reducing early childhood caries (ECC) and mutans streptococci (MS) colonization. METHODS: Subjects (n=622) recruited at birth were randomized to receive either CPP-ACP or CHX or no product (study control [SC]). All children were examined at 6, 12, and 18 months old in their homes, and at 24 months old in a community dental clinic. RESULTS: At 24 months old, the caries incidence was 1% (2/163) in CPP-ACP, 2% (4/180) in CHX, and 2% (3/188) in SC groups. In children who were previously MS colonized at 12 and 18 months old, 0% (0/11) and 5% (3/63), respectively, of the CPP-ACP group remained MS-positive versus 22% (2/9) and 72% (18/25) in CHX and 16% (4/25) and 50% (7/14) in SC groups (P<.001). CONCLUSIONS: There is insufficient evidence to justify the daily use of casein phosphopeptide-amorphous calcium phosphate or chlorhexidine gel to control early childhood caries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: This study was undertaken to compare preprandial and postprandial capillary glucose monitoring in pregnant women with type 1 diabetes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To conduct a cost-effectiveness analysis comparing two different tooth replacement strategies for partially dentate older patients, namely partial removable dental prostheses (RDP) and functionally orientated treatment based on the shortened dental arch concept (SDA).

METHODS: Ninety-two partially dentate older patients completed a randomized controlled clinical trial. Patients were randomly allocated to two treatment groups: the RDP group and the SDA group. Treatment effect was measured using impact on oral health-related quality of life (OHrQOL), and the costs involved in providing and maintaining care were recorded for all patients. Patients were followed for 12 months after treatment intervention. All treatment was provided by a single operator.

RESULTS: The total cost of achieving the minimally important clinical difference (MID) in OHrQOL for an average patient in the RDP group was €464.64. For the SDA group, the cost of achieving the MID for an average patient was €252.00. The cost-effectiveness ratio was therefore 1:1.84 in favour of SDA treatment.

CONCLUSION: With an increasingly ageing population, many patients will continue to benefit from removable prostheses to replace their missing natural teeth. From a purely economic standpoint, the results from this analysis suggest that the treatment of partially dentate older adults should be focused on functionally orientated treatment because it is simply more cost-effective.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The aim of this clinical study is to evaluate the 2-year term results of gingival recession (GR) associated with non-carious cervical lesions (NCCLs) treated by connective tissue graft (CTG) alone or in combination with a resin-modified glass ionomer restoration (CTG+R). Methods: Thirty-six patients with Miller Class I buccal GR associated with NCCLs completed the follow-up. The defects were randomly assigned to receive either CTG or CTG+R. Bleeding on probing (BOP), probing depth (PD), relative GR, clinical attachment level (CAL), and cervical lesion height coverage were measured at baseline, 6 months, 1 year, and 2 years after treatment. Results: Both groups showed statistically significant gains in CAL and soft-tissue coverage. The differences between groups were not statistically significant in BOP, PD, relative GR, or CAL after 2 years. Cervical lesion height coverage was 79.31% ± 18.51% for CTG and 71.95% ± 13.25% for CTG+R (P >0.05). Estimated root coverage was 91.56% ± 11.74% for CTG and 93.29% ± 7.97% for CTG+R (P ≥0.05). Conclusions: Within the limits of the present study, it can be concluded that both procedures provide comparable soft tissue coverage after 2 years of follow-up.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Chronic kidney disease (CKD) is one of the most serious public health problems. The increasing prevalence of CKD in developed and developing countries has led to a global epidemic. The hypothesis proposed is that patients undergoing dialysis would experience a marked negative influence on physiological variables of sleep and autonomic nervous system activity, compromising quality of life.Methods/Design: A prospective, consecutive, double blind, randomized controlled clinical trial is proposed to address the effect of dialysis on sleep, pulmonary function, respiratory mechanics, upper airway collapsibility, autonomic nervous activity, depression, anxiety, stress and quality of life in patients with CKD. The measurement protocol will include body weight (kg); height (cm); body mass index calculated as weight/height(2); circumferences (cm) of the neck, waist, and hip; heart and respiratory rates; blood pressures; Mallampati index; tonsil index; heart rate variability; maximum ventilatory pressures; negative expiratory pressure test, and polysomnography (sleep study), as well as the administration of specific questionnaires addressing sleep apnea, excessive daytime sleepiness, depression, anxiety, stress, and quality of life.Discussion: CKD is a major public health problem worldwide, and its incidence has increased in part by the increased life expectancy and increasing number of cases of diabetes mellitus and hypertension. Sleep disorders are common in patients with renal insufficiency. Our hypothesis is that the weather weight gain due to volume overload observed during interdialytic period will influence the degree of collapsibility of the upper airway due to narrowing and predispose to upper airway occlusion during sleep, and to investigate the negative influences of haemodialysis in the physiological variables of sleep, and autonomic nervous system, and respiratory mechanics and thereby compromise the quality of life of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Excessive gingival display (EGD) has a negative impact on a pleasant smile. Minimally invasive therapeutic modalities have become the standard treatment in many dentistry fields. Therefore, the aim of this study is to compare the clinical outcomes of open-flap (OF) and minimally invasive flapless (FL) esthetic crown lengthening (ECL) for the treatment of EGD.Methods: A split-mouth randomized controlled trial was conducted in 28 patients presenting with EGD. Contralateral quadrants received ECL using OF or FL techniques. Clinical parameters were evaluated at baseline and 3, 6, and 12 months post-surgery. The local levels of receptor activator of nuclear factor-kappa B ligand (RANKL) and osteoprotegerin (OPG) were assessed by enzyme-linked immunosorbent assay at baseline and 3 months. Patients' perceptions regarding morbidity and esthetic appearance were also evaluated. Periodontal tissue dimensions were obtained by computed tomography at baseline and correlated with the changes in the gingival margin (GM).Results: Patients reported low morbidity and high satisfaction with esthetic appearance for both procedures (P > 0.05). RANKL and OPG concentrations were increased in the OF group at 3 months (P < 0.05). Probing depths were reduced for both groups at all time points, compared with baseline (P < 0.05). There were no differences between groups for GM reduction at any time point (P > 0.05).Conclusions: FL and OF surgeries produced stable and similar clinical results up to 12 months. FL ECL may be a predictable alternative approach for the treatment of EGD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: To compare the effectiveness of adding cyclobenzaprine, tizanidine, or placebo to patient education and a self-care management program for patients with myofascial pain and specifically presenting with jaw pain upon awakening. Methods: Forty-five patients with a diagnosis of myofascial pain based on the guidelines of the American Academy of Orofacial Pain participated in this 3-week study. The subjects were randomly assigned into one of three groups: placebo group, TZA group (tizanidine 4 mg), or CYC group (cyclobenzaprine 10 mg). Patients were evaluated for changes in pain intensity, frequency, and duration by using the modified Severity Symptoms Index and changes in sleep quality with the use of the Pittsburgh Sleep Quality Index. Data were analyzed by ANOVA and post-hoc or nonparametric statistical tests as appropriate. Results: All three groups had a reduction in pain symptoms and improvement of sleep quality based on a comparison of pretreatment and treatment scores. However, no significant differences among the groups were observed at the posttreatment evaluation. Conclusion: The use of tizanidine or cyclobenzaprine in addition to self-care management and patient education was not more effective than placebo for the management of patients with myofascial jaw pain upon awakening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study is to compare the healing of deep, non-contained intrabony defects (i.e., with a ?80% 1-wall component and a residual 2- to 3-wall component in the most apical part) treated with either an enamel matrix derivative (EMD) or guided tissue regeneration (GTR) after 12 months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Chlorhexidine (CHX) rinsing after periodontal surgery is common. We assessed the clinical and microbiological effects of two CHX concentrations following periodontal surgery. MATERIALS AND METHODS: In a randomized, controlled clinical trial, 45 subjects were assigned to 4 weeks rinsing with a 0.05 CHX/herbal extract combination (test) or a 0.1% CHX solution. Clinical and staining effects were studied. Subgingival bacteria were assessed using the DNA-DNA checkerboard. Statistics included parametric and non-parametric tests (p<0001 to declare significance at 80% power). RESULTS: At weeks 4 and 12, more staining was found in the control group (p<0.05 and p<0.001, respectively). A higher risk for staining was found in the control group (crude OR: 2.3:1, 95% CI: 1.3 to 4.4, p<0.01). The absolute staining reduction in the test group was 21.1% (9 5% CI: 9.4-32.8%). Probing pocket depth (PPD) decreases were significant (p<0.001) in both groups and similar (p=0.92). No rinse group differences in changes of bacterial counts for any species were found between baseline and week 12. CONCLUSIONS: The test CHX rinse resulted in less tooth staining. At the study endpoint, similar and high counts of periodontal pathogens were found.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the soft and hard tissue healing and remodeling around tissue-level implants with different neck configurations after at least 1 year of functional loading. Material and methods: Eighteen patients with multiple missing teeth in the posterior area received two implants inserted in the same sextant. One test (T) implant with a 1.8 mm turned neck and one control (C) implant with a 2.8 mm turned neck were randomly assigned. All implants were placed transmucosally to the same sink depth of approximately 1.8 mm. Peri-apical radiographs were obtained using the paralleling technique and digitized. Two investigators blinded to the implant type-evaluated soft and hard tissue conditions at baseline, 6 months and 1 year after loading. Results: The mean crestal bone levels and soft tissue parameters were not significantly different between T and C implants at all time points. However, T implants displayed significantly less crestal bone loss than C implants after 1 year. Moreover, a frequency analysis revealed a higher percentage (50%) of T implants with crestal bone levels 1–2 mm below the implant shoulder compared with C implants (5.6%) 1 year after loading. Conclusion: Implants with a reduced height turned neck of 1.8 mm may, indeed, lower the crestal bone resorption and hence, may maintain higher crestal bone levels than do implants with a 2.8 mm turned neck, when sunk to the same depth. Moreover, several factors other than the vertical positioning of the moderately rough SLA surface may influence crestal bone levels after 1 year of function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The temporal pattern of bone-level alterations in conventionally restored implants is dependent upon healing mode (open or submerged). This study examined the influence of healing on marginal bone levels at implants with a medium-rough surface including the implant collar and a clearance-fit implant-abutment connection restored according to a platform-switching concept.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To test the survival rates, and the technical and biological complication rates of customized zirconia and titanium abutments 5 years after crown insertion. MATERIAL AND METHODS: Twenty-two patients with 40 single implants in maxillary and mandibular canine and posterior regions were included. The implant sites were randomly assigned to zirconia abutments supporting all-ceramic crowns or titanium abutments supporting metal-ceramic crowns. Clinical examinations were performed at baseline, and at 6, 12, 36 and 60 months of follow-up. The abutments and reconstructions were examined for technical and/or biological complications. Probing pocket depth (PPD), plaque control record (PCR) and Bleeding on Probing (BOP) were assessed at abutments (test) and analogous contralateral teeth (control). Radiographs of the implants revealed the bone level (BL) on mesial (mBL) and distal sides (dBL). Data were statistically analyzed with nonparametric mixed models provided by Brunner and Langer and STATA (P < 0.05). RESULTS: Eighteen patients with 18 zirconia and 10 titanium abutments were available at a mean follow-up of 5.6 years (range 4.5-6.3 years). No abutment fracture or loss of a reconstruction occurred. Hence, the survival rate was 100% for both. Survival of implants supporting zirconia abutments was 88.9% and 90% for implants supporting titanium abutments. Chipping of the veneering ceramic occurred at three metal-ceramic crowns supported by titanium abutments. No significant differences were found at the zirconia and titanium abutments for PPD (meanPPD(ZrO2) 3.3 ± 0.6 mm, mPPD(T) (i) 3.6 ± 1.1 mm), PCR (mPCR(Z) (rO) (2) 0.1 ± 0.3, mPCR(T) (i) 0.3 ± 0.2) and BOP (mBOP(Z) (rO) (2) 0.5 ± 0.3, mBOP(T) (i) 0.6 ± 0.3). Moreover, the BL was similar at implants supporting zirconia and titanium abutments (mBL(Z) (rO) (2) 1.8 ± 0.5, dBL(Z) (rO) (2) 2.0 ± 0.8; mBL(T) (i) 2.0 ± 0.8, dBL(T) (i) 1.9 ± 0.8). CONCLUSIONS: There were no statistically or clinically relevant differences between the 5-year survival rates, and the technical and biological complication rates of zirconia and titanium abutments in posterior regions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To compare the effects of an experimental mouth rinse containing 0.07% cetylpyridinium chloride (CPC) (Crest Pro-Health) with those provided by a commercially available mouth rinse containing essential oils (EOs) (Listerine) on dental plaque accumulation and prevention of gingivitis in an unsupervised 6-month randomized clinical trial. MATERIAL AND METHODS: This double-blind, 6-month, parallel group, positively controlled study involved 151 subjects balanced and randomly assigned to either positive control (EO) or experimental (CPC) mouth rinse treatment groups. At baseline, subjects received a dental prophylaxis procedure and began unsupervised rinsing twice a day with 20 ml of their assigned mouthwash for 30 s after brushing their teeth for 1 min. Subjects were assessed for gingivitis and gingival bleeding by the Gingival index (GI) of Löe ; Silness (1963) and plaque by the Silness ; Löe (1964) Plaque index at baseline and after 3 and 6 months of rinsing. At 3 and 6 months, oral soft tissue health was assessed. Microbiological samples were also taken for community profiling by the DNA checkerboard method. RESULTS: Results show that after 3 and 6 months of rinsing, there were no significant differences (p=0.05) between the experimental (CPC) and the positive control mouth rinse treatment groups for overall gingivitis status, gingival bleeding, and plaque accumulation. At 6 months, the covariant (baseline) adjusted mean GI and bleeding sites percentages for the CPC and the EO rinses were 0.52 and 0.53 and 8.7 and 9.3, respectively. Both mouth rinses were well tolerated by the subjects. Microbiological community profiles were similar for the two treatment groups. Statistically, a significant greater reduction in bleeding sites was observed for the CPC rinse versus the EO rinse. CONCLUSION: The essential findings of this study indicated that there was no statistically significant difference in the anti-plaque and anti-gingivitis benefits between the experimental CPC mouth rinse and the positive control EO mouth rinse over a 6-month period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To compare the clinical outcomes of standard, cylindrical, screw-shaped to novel tapered, transmucosal (Straumann Dental implants immediately placed into extraction sockets. Material and methods: In this randomized-controlled clinical trial, outcomes were evaluated over a 3-year observation period. This report deals with the need for bone augmentation, healing events, implant stability and patient-centred outcomes up to 3 months only. Nine centres contributed a total of 208 immediate implant placements. All surgical and post-surgical procedures and the evaluation parameters were discussed with representatives of all centres during a calibration meeting. Following careful luxation of the designated tooth, allocation of the devices was randomly performed by a central study registrar. The allocated SLA titanium implant was installed at the bottom or in the palatal wall of the extraction socket until primary stability was reached. If the extraction socket was >or=1 mm larger than the implant, guided bone regeneration was performed simultaneously (Bio Oss and BioGide. The flaps were then sutured. During non-submerged transmucosal healing, everything was done to prevent infection. At surgery, the need for augmentation and the degree of wound closure was verified. Implant stability was assessed clinically and by means of resonance frequency analysis (RFA) at surgery and after 3 months. Wound healing was evaluated after 1, 2, 6 and 12 weeks post-operatively. RESULTS: The demographic data did not show any differences between the patients receiving either standard cylindrical or tapered implants. All implants yielded uneventful healing with 15% wound dehiscences after 1 week. After 2 weeks, 93%, after 6 weeks 96%, and after 12 weeks 100% of the flaps were closed. Ninety percent of both implant designs required bone augmentation. Immediately after implantation, RFA values were 55.8 and 56.7 and at 3 months 59.4 and 61.1 for cylindrical and tapered implants, respectively. Patient-centred outcomes did not differ between the two implant designs. However, a clear preference of the surgeon's perception for the appropriateness of the novel-tapered implant was evident. CONCLUSIONS: This RCT has demonstrated that tapered or standard cylindrical implants yielded clinically equivalent short-term outcomes after immediate implant placement into the extraction socket.