966 resultados para Radiography dental digital


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Root resorption can cause damage in orthodontic patients. Digital subtraction radiography (DSR) is a useful resource for the detection of mineral losses. The purpose of this study was to compare the efficacy of digital radiography (DR) and DSR in detecting simulated external root resorption. Examiner agreement between the 2 techniques was also evaluated. Methods: Root resorptions of various sizes were simulated on the apical and lingual aspects of 49 teeth from 9 dry human mandibles. The teeth were radiographed in standardized conditions. The radiographs were registered with Regeemy Image Registration and Mosaicking (version 0.2.43-RCB, DPI-INPE, Sao Jose dos Campos, São Paulo, Brazil) and subtracted with Image Tool (University of Texas Health Science Center at San Antonio). The subtracted images and the digital radiographs were evaluated by 3 oral radiologists. Results: No statistically significant differences were found for the methods in the detection of apical root resorptions, independently from lesion size, and of lingual resorptions of 1.2 mm or greater. DSR was significantly better than DR for detection of lingual resorptions up to 1 mm. Resorptions less than 0.5 mm were not precisely detected by either method. DSR provided better intraexaminer and interexaminer agreement than did DR. Conclusions: Both methods are precise for detection of apical root resorptions as small as 0.5 mm and lingual resorptions of 1 mm or more. However, DSR frequently performed better than did DR. (Am J Orthod Dentofacial Orthop 2011;139:324-33)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Tissue reactions to 4 different implant surfaces were evaluated in regard to the development and progression of ligature-induced peri-implantitis. Materials and Methods: In 6 male mongrel dogs, a total of 36 dental implants with different surfaces (9 titanium plasma-sprayed, 9 hydroxyapatite-coated, 9 acid-etched, and 9 commercially pure titanium) were placed 3 months after mandibular premolar extraction. After 3 months with optimal plaque control, abutment connection was performed. Forty-five days later, cotton ligatures were placed around the implants to induce peri-implantitis. At baseline and 20, 40, and 60 days after placement, the presence of plaque, peri-implant mucosal redness, bleeding on probing, probing depth, clinical attachment loss, mobility, vertical bone loss, and horizontal bone loss were assessed. Results: The results did not show significant differences among the surfaces for any parameter during the study (P > .05). All surfaces were equally susceptible to ligature-induced peri-implantitis over time (P < .001). Correlation analysis revealed a statistically significant relationship between width of keratinized tissue and vertical bone loss (r 2 = 0.81; P = .014) and between mobility and vertical bone loss (r 2 = 0.66; P = .04), both for the titanium plasma-sprayed surface. Discussion and Conclusions: The present data suggest that all surfaces were equally susceptible to experimental peri-implantitis after a 60-day period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Biopatologia Bucal - ICT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of this study was to analyse the use of digital tools for image enhancement of mandibular radiolucent lesions and the effects of this manipulation on the percentage of correct radiographic diagnoses. Methods: 24 panoramic radiographs exhibiting radiolucent lesions were selected, digitized and evaluated by non-experts (undergraduate and newly graduated practitioners) and by professional experts in oral diagnosis. The percentages of correct and incorrect diagnoses, according to the use of brightness/contrast, sharpness, inversion, highlight and zoom tools, were compared. All dental professionals made their evaluations without (T-1) and with (T-2) a list of radiographic diagnostic parameters. Results: Digital tools were used with low frequency mainly in T-2. The most preferred tool was sharpness (45.2%). In the expert group, the percentage of correct diagnoses did not change when any of the digital tools were used. For the non-expert group, there was an increase in the frequency of correct diagnoses when brightness/contrast was used in T-2 (p = 0.008) and when brightness/contrast and sharpness were not used in T-1 (p = 0.027). The use or non-use of brightness/contrast, zoom and sharpness showed moderate agreement in the group of experts [kappa agreement coefficient (kappa) = 0.514, 0.425 and 0.335, respectively]. For the non-expert group there was slight agreement for all the tools used (kappa <= 0.237). Conclusions: Consulting the list of radiographic parameters before image manipulation reduced the frequency of tool use in both groups of examiners. Consulting the radiographic parameters with the use of some digital tools was important for improving correct diagnosis only in the group of non-expert examiners. Dentomaxillofacial Radiology (2012) 41, 203-210. doi: 10.1259/dmfr/78567773

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since bovine teeth have been used as substitutes for human teeth in in vitro dental studies, the aim of this study was to compare the radiographic density of bovine teeth with that of human teeth to evaluate their usability for radiographic studies. Thirty bovine and twenty human teeth were cut transversally in 1 millimeter-thick slices. The slices were X-rayed using a digital radiographic system and an intraoral X-ray machine at 65 kVp and 7 mA. The exposure time (0.08 s) and the target-sensor distance (40 cm) were standardized for all the radiographs. The radiographic densities of the enamel, coronal dentin and radicular dentin of each slice were obtained separately using the histogram tool of Adobe Photoshop 7.0 software. The mean radiographic densities of the enamel, coronal dentin and radicular dentin were calculated by the arithmetic mean of the slices of each tooth. One-way ANOVA demonstrated statistically significant differences for the densities of bovine and human enamel (p < 0.05) and for bovine and human coronal dentin (p < 0.05). No statistically significant differences were found for the bovine and human radicular dentin (p > 0.05). Based on the results, the authors concluded that: a) the radiographic density of bovine enamel is significantly higher than that of human enamel; b) the radiodensity of bovine coronal dentin is statistically lower than the radiodensity of human coronal dentin; bovine radicular dentin is also less radiodense than human radicular dentin, although this difference was not statistically significant; c) bovine teeth should be used with care in radiographic in vitro studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of radiotherapy on the radiopacity and flexural strength of composite resin. Forty Z250 composite resin specimens were polymerized using a halogen light-curing unit and divided into 5 groups, in accordance with the radiotherapy dose: G1- without irradiation, G2- 30 Gy, G3- 40 Gy, G4- 50 Gy and GS- 60 Gy Digital images were obtained using a GE 100 X-ray. Radiopacity values were obtained with the Digora digital imaging system and the flexural strength was evaluated with an EMIC universal testing machine. Data were submitted to ANOVA and Tukey 's test. G1 presented the highest radiopacity value, followed by G3, G5, G4 and G2. For flexural strength, G1 presented the lowest value, followed by G2, G5, G3 and G4. Differences were no significant (p>0.05). The commonly used dosage of radiotherapy treatment, did not cause alteration in the radiopacity and flexural strength of resin-based composites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several studies have shown that diabetics are more susceptible to the development of severe periodontal disease. Currently, the use of animal models can be considered a feasible alternative in radiographic assessments of these two pathologies. The purpose of this radiographic study was to evaluate the effect of induced diabetes mellitus on alveolar bone loss after 30 days of ligature-induced periodontal disease. Sixty-four Wistar rats were randomly distributed into four experimental groups. Diabetes was induced in Groups II and IV, while periodontal disease was induced in Groups III and IV; Group I was used as control. In order to perform the radiographic assessment of the specimens, the rats were killed on the 3rd and 30th days of the study. Radiographic measurements were assessed with ANOVA and Tukey's test to determine statistically significant differences (p < 0.05). It was observed that Groups III and IV featured greater bone loss when compared to Groups I and II. Only the diabetic group with periodontal disease (Group IV) featured statistically significant greater bone loss when compared to the other groups. These results suggested that the alveolar bone loss resulting from the periodontal disease installation is greater when associated to the diabetes mellitus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate whether digitized images obtained from occlusal radiographs taken with low or over dose of radiation could be improved with the aid of computer software for digital treatment. Thirteen occlusal radiographs of a dry skull were taken employing 13 different exposure times. The radiographs were digitized and then manipulated with the program for image editing. 143 evaluations were performed by specialists in dental radiology who classified radiographs as appropriate or not appropriate for interpretation. Test Z was used for statistical analysis of the data and the results showed that it is possible to manipulate digitized radiographic images taken with 75% of the ideal exposure time and to make them suitable for interpretation and diagnosis. Conversely, it was concluded that the over exposed images, 57.50% above the standard exposure time, were inadequate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim of this study was to compare cone beam CT (CBCT) in a small field of view (FOV) with a solid-state sensor and a photostimulable phosphor plate system for detection of cavitated approximal surfaces. Methods: 257 non-filled approximal surfaces from human permanent premolars and molars were recorded by two intraoral digital receptors, a storage phosphor plate (Digora Optime, Soredex) and a solid-state CMOS sensor (Digora Toto, Soredex), and scanned in a cone beam CT unit (3D Accuitomo FPD80, Morita) with a FOV of 4 cm and a voxel size of 0.08 mm. Image sections were carried out in the axial and mesiodistal tooth planes. Six observers recorded surface cavitation in all images. Validation of the true absence or presence of surface cavitation was performed by inspecting the surfaces under strong light with the naked eye. Differences in sensitivity, specificity and agreement were estimated by analysing the binary data in a generalized linear model using an identity link function. Results: A significantly higher sensitivity was obtained by all observers with CBCT (p,0.001), which was not compromised by a lower specificity. Therefore, a significantly higher overall agreement was obtained with CBCT (p,0.001). There were no significant differences between the Digora Optime phosphor plate system and the Digora Toto CMOS sensor for any parameter. Conclusions: CBCT was much more accurate in the detection of surface cavitation in approximal surfaces than intraoral receptors. The differences are interpreted as clinically significant. A CBCT examination performed for other reasons should also be assessed for approximal surface cavities in teeth without restorations. © 2013 The British Institute of Radiology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: This in vitro study evaluated the accuracy of primary incisor lengths determined by digital and conventional radiography compared to the actual tooth length. Methods: Twenty extracted primary maxillary incisors were mounted in acrylic blocks. Tooth length was estimated by using a straight-line measurement provided by the distance measurement tool of a digital dental imaging system (Computed Dental Radiography, Schick Technologies Inc.) and conventional E-speed film radiographs by using a digital caliper. Two operators familiar with both radiographic methods performed the estimates. The estimated tooth lengths were compared to the actual tooth lengths measured with the digital caliper. Data were statistically analyzed by Dahlberg's equation, paired t test, Pearson's correlation coefficient and ANOVA at 5% significance level. Results: There were no statistically significant differences (p = 0.85) between tooth length estimated on digital and conventional radiographs. Admitting as clinically acceptable a 0.5-mm discrepancy between the actual tooth lengths and the radiographically estimated lengths, 60% of the radiographic measurements were considered as accurate. When the acceptable difference range was 1.0 mm, the accuracy of the radiographic measurements increased to 100%. Conclusions: Digital and conventional radiography provided similar tooth length measurements and were equivalent to the actual tooth lengths.