310 resultados para Radiant heats
Resumo:
The aim of this paper is to verify the correlation between environmental indicators and behaviors expressed by laying hens kept in cages. The birds react to a severe environment through their behaviors, end the behaviors can be monitored to identify the birds' welfare conditions. The behaviors birds display ere the result of stress caused by the combination of environmental temperature, relative humidity, radiant heat, and air speed (environmental temperature being the most important). In order to check the influence of the environment, an experiment was carried out on a commercial poultry farm, located in the city of Bastos. The study was initiated in March 2007, during four non-consecutive weeks. The birds' behaviors were recorded using video, by cameras installed in the cages. The birds behaviors were identified and noted for the frequency of occurrence for each bird, and the average duration of each behavior (in seconds), using video samples of 15 minutes recorded from 1 PM to 4 PM. The environmental variables collected were: air temperature, concentration of ammonia, relative air humidity, velocity of the air, noise, roof temperature, and light intensity. The observed behaviors were: opening wings, stretching, threatening, ruffling feathers, drinking water, aggressive pecking, eating, running, lying down, stretching head out of the cage, preening, mounting and prostrating. Principal Components Analysis was used to determine associations between the behavior variables and environmental variables described above. In this experiment, there were no significant correlations between behavioral variables and environmental variables.
Resumo:
This paper argues that young people need to be given the opportunity to recognise the interaction between their own understandings of the world as it is now and the vision of what it might become. To support this argument, we discuss an urban planning project, known as the Lower Mill Site Project, which involved active participation of high school students from the local community. The outcomes of this project demonstrate the positive contributions young people can make to the process of urban redevelopment, the advantages of using a participatory design approach, and the utopian possibilities that can emerge when young people are invited to be part of an intergenerational community project.
Resumo:
The enthalpies of reaction between aniline and HCHO at various molar proportions under neutral conditions were determined by solution calorimetry. These measurements are new in the field of aniline and HCHO condensation polymers. The specific heats of the products formed were determined by differential scanning calorimetry and were used in the enthalpy calculations. Plots of enthalpy of reaction calculated with respect to aniline and HCHO vs. different A/F molar ratios were made. From the enthalpy data it appears that the reactions between different A/F molar ratios yield different products.
Resumo:
The standard heats of combustion of the disubstituted ureas, N, N′-diheptyl urea, N, N′-dioctyl urea and N, N′-didecyl urea and the carbamates,n-heptyl ammoniumn-heptyl carbamate,n-octylammoniumn-octyl carbamate andn-decyl ammoniumn-decyl carbamate have been determined. The values found are 2353±1·3, 2658·4±1·1, 3268·5±1·7, 2349·8±1·6, 2654·4±1·2, 3264·6±1·8, K.cals. mole−1 respectively. The heats of formation of these compounds have been calculated.
Resumo:
A great deal of data on the heats of formation of various hydrates has been compiled i n the J.A.N.A.F. and other tables such as the National Bureau of Standards circulars. Comparison of the heat of f ormation of a hydrate with that of the corresponding anhydrate exposes anomalies i n a surprising number of cases. Some of the results are so discordant that i t is apparent that one or the other value is seriously mistaken. No attempt has been made i n this work to determine which value may be correct, but measurements have been made of the difference between these two values. The procedure adopted has been to dissolve the hydrate and the anhydrate, to achieve the same final concentration of the compound in solution, and so to measure the difference in heats of solution .. Measurements were made at OOC in a modified Bunsen ice calorimeter, well insulated and surrounded by an icewater mixture . The observed differences in heats of solut ion were corrected t o 25°0 by using appropriate heat capacity data. These differences offer a direct measure of the enthalpy involved in binding a mole of water into the crystal structure and so should shed light on the nature of binding involved. The following hydrates were studied : MgS04.nH20 (n = 1,4,7), MnC12.nH20 (n = 1, 2), LiI. nH20 (n = 1,3), MnS04. nH20 (n = 1,4), CaC12. nH20 (n = 2,6) , K2C03.1~H20, LiCl.H20, LiBr.2H20, CdC12.2t H2o, and N2H4eH20.
Resumo:
This paper discusses the results of a study to determine the differences between hearing aids and radiant beamforming technology.
Resumo:
Vegetation and building morphology characteristics are investigated at 19 sites on a north-south LiDAR transect across the megacity of London. Local maxima of mean building height and building plan area density at the city centre are evident. Surprisingly, the mean vegetation height (zv3) is also found to be highest in the city centre. From the LiDAR data various morphological parameters are derived as well as shadow patterns. Continuous images of the effects of buildings and of buildings plus vegetationon sky view factor (Ψ) are derived. A general reduction of Ψ is found, indicating the importance of including vegetation when deriving Ψ in urban areas. The contribution of vegetation to the shadowing at ground level is higher during summer than in autumn. Using these 3D data the influence on urban climate and mean radiant temperature (T mrt ) is calculated with SOLWEIG. The results from these simulations highlight that vegetation can be most effective at reducing heat stress within dense urban environments in summer. The daytime average T mrt is found to be lowest in the densest urban environments due to shadowing; foremost from buildings but also from trees. It is clearly shown that this method could be used to quantify the influence of vegetation on T mrt within the urban environment. The results presented in this paper highlight a number of possible climate sensitive planning practices for urban areas at the local scale (i.e. 102- 5 × 103 m).
Resumo:
The solar and longwave environmental irradiance geometry (SOLWEIG) model simulates spatial variations of 3-D radiation fluxes and mean radiant temperature (T mrt) as well as shadow patterns in complex urban settings. In this paper, a new vegetation scheme is included in SOLWEIG and evaluated. The new shadow casting algorithm for complex vegetation structures makes it possible to obtain continuous images of shadow patterns and sky view factors taking both buildings and vegetation into account. For the calculation of 3-D radiation fluxes and T mrt, SOLWEIG only requires a limited number of inputs, such as global shortwave radiation, air temperature, relative humidity, geographical information (latitude, longitude and elevation) and urban geometry represented by high-resolution ground and building digital elevation models (DEM). Trees and bushes are represented by separate DEMs. The model is evaluated using 5 days of integral radiation measurements at two sites within a square surrounded by low-rise buildings and vegetation in Göteborg, Sweden (57°N). There is good agreement between modelled and observed values of T mrt, with an overall correspondence of R 2 = 0.91 (p < 0.01, RMSE = 3.1 K). A small overestimation of T mrt is found at locations shadowed by vegetation. Given this good performance a number of suggestions for future development are identified for applications which include for human comfort, building design, planning and evaluation of instrument exposure.
Resumo:
The effect of variations in land cover on mean radiant surface temperature (Tmrt) is explored through a simple scheme developed within the radiation model SOLWEIG. Outgoing longwave radiation is parameterised using surface temperature observations on a grass and an asphalt surface, whereas outgoing shortwave radiation is modelled through variations in albedo for the different surfaces. The influence of surface materials on Tmrt is small compared to the effects of shadowing. Nevertheless, altering ground surface materials could contribute to a reduction on Tmrt to reduce the radiant load during heat-wave episodes in locations where shadowing is not an option. Evaluation of the new scheme suggests that despite its simplicity it can simulate the outgoing fluxes well, especially during sunny conditions. However, it underestimates at night and in shadowed locations. One grass surface used to develop the parameterisation, with very different characteristics compared to an evaluation grass site, caused Tmrt to be underestimated. The implications of using high resolution (e.g. 15 minutes) temporal forcing data under partly cloudy conditions are demonstrated even for fairly proximal sites.
Resumo:
Structural, energetic, and vibrational properties of new molecular species, HSeF and HFSe, the associated transition state, and dissociation fragments are investigated using a state-of-the-art theoretical approach, CCSD(T)/CBS. HSeF is a normal covalently bonded molecule 38.98 kcal mol (1) more stable than the complex HF-Se, which shows an unusual structure with a central fluorine atom and a bond angle of 101.8 degrees.A barrier (Delta G(#)) of 49.01 kcal mol (1) separates the two species. Vibrational frequencies are also quite distinct. Heats of formation are evaluated for the diatomic fragments and HSeF. Final Delta(f)H values depend on the experimental accuracy of those of Se(g) and H(2)Se. (c) 2009 Elsevier B.V. All rights reserved.
Resumo:
Monitoring non-ionizing radiant energy is increasingly demanded for many applications such as automobile, biomedical and security system. Thermal type infrared (IR) sensors can operate at room temperature and pyroelectric materials have high sensitivity and accuracy for that application. Working as thermal transducer pyroelectric sensor converts the non-quantified thermal flux into the output measurable quantity of electrical charge, voltage or current. In the present study the composite made of poly(vinylidene fluoride) -PVDF and lead zirconate titanate (PZT) partially recovered with polyaniline (PAni) conductor polymer has been used as sensor element. The pyroelectric coefficient p(T) was obtained by measuring the pyroelectric reversible current, i.e., measuring the thermally stimulated depolarization current (TSDC) after removing all irreversible contribution to the current such as injected charge during polarization of the sample. To analyze the sensing property of the pyroelectric material, the sensor is irradiated by a high power light source (halogen lamp of 250 W) that is chopped providing a modulated radiation. A device assembled in the laboratory is used to change the light intensity sensor, an aluminum strip having openings with diameters ranging from 1 to 10 mm incremented by one millimeter. The sensor element is assembled between two electrodes while its frontal surface is painted black ink to maximize the light absorption. The signal from the sensor is measured by a Lock-In amplifier model SR530 -Stanford Research Systems. The behavior of the output voltage for an input power at several frequencies for PZT-PAni/PVDF (30/ 70 vol%) composite follows the inverse power law (1/ f) and the linearity can be observed in the frequency range used.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)