1000 resultados para Radial Guide
Resumo:
A field matching method is described to analyze a recessed circular cavity radiating into a radial waveguide. Using the wall impedance approach, the analysis is divided into two separate problems of the cavity and its external environment. Based on this analysis, a computer algorithm is developed for determining wall admittances as seen at the edge of the patch in the cavity, the radial admittance matrix for the two-probe feed arrangement, and the input impedance as observed from the coaxial line feeding the cavity. This algorithm is tested against the general-purpose Hewlett-Packard finite-element High Frequency Structure Simulator as well as against measured results. Good agreement in all considered cases is noted.
Resumo:
The design of a switched-beam antenna formed by a circular array of monopoles housed inside a radial guide with a transition to free space is presented. Two alternative types of transitions to free space, one using a truncated conducting cone and the other created by a tapered dielectric material at the edge of the radial guide, are described. The use of the radial guide with transition increases the return-loss bandwidth of the array and enables shaping its beam in elevation. (C) 2004 Wiley Periodicals, Inc.
Resumo:
A radial guide field matching method (RGFMM) is used to analyze a circular array antenna consisting of one active monopole surrounded by a concentric array of passive monopoles terminated in arbarary loads. An equivalent admittance matrix for this antenna system is determined to study the input admittance of the active monopole when the peripheral elements are terminated in open or short circuits. RGFMM results are compared with free-space method of moments (FS-MoM) results for a small switched-beam array a seven monopoles. Good agreement is noted. (C) 2002 Wiley Periodicals, Inc.
Resumo:
This communications describes an electromagnetic model of a radial line planar antenna consisting of a radial guide with one central probe and many peripheral probes arranged in concentric circles feeding an array of antenna elements such as patches or wire curls. The model takes into account interactions between the coupling probes while assuming isolation of radiating elements. Based on this model, computer programs are developed to determine equivalent circuit parameters of the feed network and the radiation pattern of the radial line planar antenna. Comparisons are made between the present model and the two-probe model developed earlier by other researchers.
Resumo:
Using a Radial Guide Field Matching Method, an investigation is performed into reducing the height of an electronically steered circular array of monopole antennas composed of a central active element surrounded by passive elements being either short- or open-circuited. It is shown that a considerable height reduction can be achieved using top hats attached to monopoles ends and by applying dielectric coating underneath the top hats. The trade-off in achieving height reduction is narrower impedance bandwidth.
Resumo:
BACKGROUND: Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance without a guide sheath has not been reported. METHODS: We conducted a retrospective analysis of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy procedures for the investigation of PPL performed by experienced bronchoscopists with no specific previous training in this particular technique. Operator learning curves and radiological predictors were assessed for all consecutive patients examined during the first year of application of the technique. RESULTS: Fifty-one PPL were investigated. Diagnostic yield and visualization yield were 72.5 and 82.3% respectively. The diagnostic yield was 64.0% for PPL ≤20mm, and 80.8% for PPL>20mm. No false-positive results were recorded. The learning curve of all diagnostic tools showed a DY of 72.7% for the first sub-group of patients, 81.8% for the second, 72.7% for the third, and 81.8% for the last. CONCLUSION: Bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance is safe and simple to perform, even without specific prior training, and diagnostic yield is high for PPL>and ≤20mm. Based on these findings, this method could be introduced as a first-line procedure for the investigation of PPL, particularly in centers with limited resources.
Resumo:
Cover title: Qualitation and quantitation of immunoglobulins.
Resumo:
The goal of this paper is to present an optimal resource allocation model for the regional allocation of public service inputs. Theproposed solution leads to maximise the relative public service availability in regions located below the best availability frontier, subject to exogenous budget restrictions and equality ofaccess for equal need criteria (equity-based notion of regional needs). The construction of non-parametric deficit indicators is proposed for public service availability by a novel application of Data Envelopment Analysis (DEA) models, whose results offer advantages for the evaluation and improvement of decentralised public resource allocation systems. The method introduced in this paper has relevance as a resource allocation guide for the majority of services centrally funded by the public sector in a given country, such as health care, basic and higher education, citizen safety, justice, transportation, environmental protection, leisure, culture, housing and city planning, etc.
Resumo:
36
Resumo:
To evaluate the outcomes in patients treated for humerus distal third fractures with MIPO technique and visualization of the radial nerve by an accessory approach, in those without radial palsy before surgery. The patients were treated with MIPO technique. The visualization and isolation of the radial nerve was done by an approach between the brachialis and the brachiorradialis, with an oblique incision, in the lateral side of the arm. MEPS was used to evaluate the elbow function. Seven patients were evaluated with a mean age of 29.8 years old. The average follow up was 29.85 months. The radial neuropraxis after surgery occurred in three patients. The sensorial recovery occurred after 3.16 months on average and also of the motor function, after 5.33 months on average, in all patients. We achieved fracture consolidation in all patients (M=4.22 months). The averages for flexion-extension and prono-supination were 112.85° and 145°, respectively. The MEPS average score was 86.42. There was no case of infection. This approach allowed excluding a radial nerve interposition on site of the fracture and/or under the plate, showing a high level of consolidation of the fracture and a good evolution of the range of movement of the elbow. Level of Evidence IV, Case Series.
Resumo:
Nocardia is a rare opportunistic agent, which may affect immunocompromised individuals causing lung infections and exceptionally infective endocarditis (IE). There are few reports of IE caused by Nocardia sp., usually involving biological prostheses but rarely in natural valves. Its accurate microbiological identification may be hampered by the similarity with Rhodococcus equi and Corynebacterium spp. Here we report a case of native mitral valve IE caused by this agent in which the clinical absence of response to vancomycin and the suggestion of Nocardia sp. by histology pointed to the misdiagnosis of Corynebacterium spp. in blood cultures. The histological morphology can advise on the need for expansion of cultivation time and use of extra microbiological procedures that lead to the differential diagnosis with Corynebacterium spp. and other agents, which is essential to establish timely specific treatment, especially in immunocompromised patients.